There is a need among scientists and clinicians for low-noise, low-power biosignal amplifiers capable of amplifying signals in the mHz to kHz range while rejecting large dc offsets generated at the electrode-tissue interface. The advent of fully-implantable multielectrode arrays has created the need for fully-integrated micropower amplifiers. We designed and tested a novel bioamplifier that uses a MOS-bipolar pseudo-resistor to amplify signals down to the mHz range while rejecting large dc offsets. We derive the theoretical noise-power tradeoff limit - the noise efficiency factor - for this amplifier and demonstrate that our VLSI implementation approaches that limit. The resulting amplifier, built in a standard 1.5/spl mu/m CMOS process, passes signals from 0.1mHz to 7.2kHz with an input-referred noise of 2.2/spl mu/Vrms and a power dissipation of 80/spl mu/W while consuming 0.16mm/sup 2/ of chip area.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695
Self-citationA micropower low-noise monolithic instrumentation amplifier for medical purposes
Steyaert, M. S. J., & Sansen, W. M. C. (1987) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1987.1052869 · Cited by 577
An implantable multielectrode array with on-chip signal processing
Najafi, K., & Wise, K. D. (1986) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1986.1052646 · Cited by 310
Cited by
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695
Self-citationOlssonIII, R. H., Buhl, D. L., Sirota, A. M., Buzsaki, G., & Wise, K. D. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.847540 · Cited by 181
“1 mHz [21] that were highly variable with transistor threshold voltage.”
BackgroundMethodNoncontact Wearable Wireless ECG Systems for Long-Term Monitoring
Majumder, S., Chen, L., Marinov, O., Chen, C.-H., Mondal, T., & Deen, M. J. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2018.2840336 · Cited by 165
“[71], [73], [81], [89], or DSLs [75], [90].”
BackgroundNeuroBus - Architecture for an Ultra-Flexible Neural Interface
Sporer, M., Vasilaş, I.-G., Adžemović, A., Graber, N., Reich, S., Gueli, C., Eickenscheidt, M., Diester, I., Stieglitz, T., & Ortmanns, M. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3354785 · Cited by 13
Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review
Habibollahi, M., Jiang, D., Lancashire, H. T., & Demosthenous, A. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3430038 · Cited by 11
Metadata
- Authors
- Harrison, R. R.
- Venue
- 2002 IEEE International Symposium on Circuits and Systems. Proceedings (Cat. No.02CH37353)
- Publisher
- IEEE
- Published
- 2003-06-25
- Volume
- 5
- Pages
- V-197-V-200
- ISSN
- 0271-4302 (ISSN-L)
- OpenAlex
- W2098477238
- Cited by
- 155
- References
- 3
- FWCI
- 7.55
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.