CoChat

A 0.1mm/sup 2/, Digitally Programmable Nerve Stimulation Pad Cell with High-Voltage Capability for a Retinal Implant

Ortmanns, M., Unger, N., Rocke, A., Gehrke, M., Tietdke, H.J. · 2006 · 2006 IEEE International Solid State Circuits Conference - Digest of Technical Papers
Cited by 48

The DOI matches its Crossref record.

Abstract

A 0.1mm2autonomous and digitally programmable nerve stimulation pad cell in 0.35μm HVCMOS is used in a 232-electrode retinal implant. It provides greater than plusmn15V swing at the electrode in order to supply suitable stimulation currents into large electrode impedances. Customized ESD protection is used on all electrodes. Charge balancing is applied to prevent electrolysis

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/isscc.2006.1696037

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 48

Metadata

Authors
Ortmanns, M., Unger, N., Rocke, A., Gehrke, M., & Tietdke, H. J.
Venue
2006 IEEE International Solid State Circuits Conference - Digest of Technical Papers
Publisher
IEEE
Published
2006
Pages
89-98
ISSN
0193-6530 (ISSN-L)
OpenAlex
W2053715347
Cited by
48
References
0
FWCI
28.48
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A 0.1mm/sup 2/, Digitally Programmable Nerve Stimulation Pad Cell with High-Voltage Capability for a Retinal Implant. https://app.cochat.ai/papers/10.1109/isscc.2006.1696037
The paper
Ortmanns, M., Unger, N., Rocke, A., Gehrke, M., & Tietdke, H. J. (2006). A 0.1mm/sup 2/, Digitally Programmable Nerve Stimulation Pad Cell with High-Voltage Capability for a Retinal Implant. 2006 IEEE International Solid State Circuits Conference - Digest of Technical Papers. https://doi.org/10.1109/isscc.2006.1696037

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.