A 0.1mm/sup 2/, Digitally Programmable Nerve Stimulation Pad Cell with High-Voltage Capability for a Retinal Implant
The DOI matches its Crossref record.
Abstract
A 0.1mm2autonomous and digitally programmable nerve stimulation pad cell in 0.35μm HVCMOS is used in a 232-electrode retinal implant. It provides greater than plusmn15V swing at the electrode in order to supply suitable stimulation currents into large electrode impedances. Customized ESD protection is used on all electrodes. Charge balancing is applied to prevent electrolysis
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A 232-Channel Epiretinal Stimulator ASIC
Ortmanns, M., Rocke, A., Gehrke, M., & Tiedtke, H.-J. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2007.908693 · Cited by 225
“For the stimulation of retinal tissue, this led to the usage of switched current pulses with maximum pulse length of several milliseconds and maximum stimulation amplitudes of up to 1 mA [8], [17], [20], [23], [ 24 ].”
BackgroundMethodResultSelf-citationSit, J.-J., & Sarpeshkar, R. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.911631 · Cited by 155
“Finally, a feedback strategy to monitor any residual voltage on the electrode capacitance after each biphasic pulse and then apply stimulation currents until the residual voltage falls within a safe window ( 100 mV) was proposed in [ 10 ].”
MethodRetinal Neurostimulator for a Multifocal Vision Prosthesis
Wong, Y. T., Dommel, N., Preston, P., Hallum, L. E., Lehmann, T., Lovell, N. H., & Suaning, G. J. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903958 · Cited by 79
Bionic eye review - An update.
Nowik, K., Langwińska-Wośko, E., Skopiński, P., Nowik, K. E., & Szaflik, J. P. (2020) · Journal of Clinical Neuroscience · doi:10.1016/j.jocn.2020.05.041 · Cited by 49
Recent advances in charge balancing for functional electrical stimulation
Sooksood, K., Stieglitz, T., & Ortmanns, M. (2009) · 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2009.5333181 · Cited by 20
Self-citationActive Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review
Habibollahi, M., Jiang, D., Lancashire, H. T., & Demosthenous, A. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3430038 · Cited by 11
Metadata
- Authors
- Ortmanns, M., Unger, N., Rocke, A., Gehrke, M., & Tietdke, H. J.
- Venue
- 2006 IEEE International Solid State Circuits Conference - Digest of Technical Papers
- Publisher
- IEEE
- Published
- 2006
- Pages
- 89-98
- ISSN
- 0193-6530 (ISSN-L)
- OpenAlex
- W2053715347
- Cited by
- 48
- References
- 0
- FWCI
- 28.48
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.