sEMG-Based Joint Force Control for an Upper-Limb Power-Assist Exoskeleton Robot
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
This paper investigates two surface electromyogram (sEMG)-based control strategies developed for a power-assist exoskeleton arm. Different from most of the existing position control approaches, this paper develops force control methods to make the exoskeleton robot behave like humans in order to provide better assistance. The exoskeleton robot is directly attached to a user's body and activated by the sEMG signals of the user's muscles, which reflect the user's motion intention. In the first proposed control method, the forces of agonist and antagonist muscles pair are estimated, and their difference is used to produce the torque of the corresponding joints. In the second method, linear discriminant analysis-based classifiers are introduced as the indicator of the motion type of the joints. Then, the classifier's outputs together with the estimated force of corresponding active muscle determine the torque control signals. Different from the conventional approaches, one classifier is assigned to each joint, which decreases the training time and largely simplifies the recognition process. Finally, the extensive experiments are conducted to illustrate the effectiveness of the proposed approaches.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149 · cited 1×
“and corresponding motion in device [29].”
A robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743 · cited 5×
“As for the classifier selection, it is well known that LDA in classifying sEMG is with better performance than some other classifiers (e.g., SVM) [24], [25], and there exist few parameters necessary to be selected.”
MethodInfluentialMyoelectric control systems—A survey
Asghari Oskoei, M., & Hu, H. (2007) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.07.009 · Cited by 1,244 · cited 1×
“In [9], the rehabilitation devices or assistive robots could incorporate the information extracted from sEMG and recognize the signal patterns.”
BackgroundAn EMG-driven musculoskeletal model to estimate muscle forces and knee joint moments in vivo
Lloyd, D. G., & Besier, T. F. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00010-1 · Cited by 1,199 · cited 1×
“The common method on estimating muscle forces from the sEMG signals is to approximate the active state for a Hilltype muscle model [21], [22].”
MethodTargeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089
Support Vector Machine-Based Classification Scheme for Myoelectric Control Applied to Upper Limb
Oskoei, M. A., & Hu, H. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.919734 · Cited by 829 · cited 1×
“Using offline approaches, the accuracy of sEMG pattern recognition can be more than 90% through employing various classifiers, such as linear discriminant analysis (LDA) [13], time-delayed artificial neural networks [14], and support vector machines (SVMs) [15].”
MethodStudy of stability of time-domain features for electromyographic pattern recognition
Tkach, D., Huang, H., & Kuiken, T. A. (2010) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-7-21 · Cited by 582 · cited 1×
“[30] conducted a study of many time-domain features.”
BackgroundAn EMG-Based Control for an Upper-Limb Power-Assist Exoskeleton Robot
Kiguchi, K., & Hayashi, Y. (2012) · IEEE Transactions on Systems, Man, and Cybernetics, Part B (Cybernetics) · doi:10.1109/tsmcb.2012.2185843 · Cited by 531 · cited 1×
“joints’ force from the sEMG signal, [6], [17]–[20].”
BackgroundQuantifying Pattern Recognition—Based Myoelectric Control of Multifunctional Transradial Prostheses
Li, G., Schultz, A. E., & Kuiken, T. A. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039619 · Cited by 443
Comparison of algorithms for estimation of EMG variables during voluntary isometric contractions
Farina, D., & Merletti, R. (2000) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(00)00025-0 · Cited by 367
On the mechanical design of the Berkeley Lower Extremity Exoskeleton (BLEEX)
Zoss, A., Kazerooni, H., & Chu, A. (2005) · 2005 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2005.1545453 · Cited by 305
Online Electromyographic Control of a Robotic Prosthesis
Shenoy, P., Miller, K. J., Crawford, B., & Rao, R. P. N. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.909536 · Cited by 285
Potvin, J. R., & Brown, S. H. M. (2004) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2003.10.005 · Cited by 227
An EMG-Based Robot Control Scheme Robust to Time-Varying EMG Signal Features
Artemiadis, P. K., & Kyriakopoulos, K. J. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2010.2040832 · Cited by 224
Decoding a New Neural–Machine Interface for Control of Artificial Limbs
Zhou, P., Lowery, M. M., Englehart, K. B., Huang, H., Li, G., Hargrove, L., Dewald, J. P. A., & Kuiken, T. A. (2007) · Journal of Neurophysiology · doi:10.1152/jn.00178.2007 · Cited by 215
Hargrove, L. J., Li, G., Englehart, K. B., & Hudgins, B. S. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2008171 · Cited by 211
EMG to force processing I: An electrical analogue of the hill muscle model
Hof, A. L., & Van den Berg, J. (1981) · Journal of Biomechanics · doi:10.1016/0021-9290(81)90031-2 · Cited by 207
Potvin, J. R., Norman, R. W., & McGill, S. M. (1996) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00376504 · Cited by 202
Huang, H., Zhou, P., Li, G., & Kuiken, T. A. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.910282 · Cited by 187
Using uncorrelated discriminant analysis for tissue classification with gene expression data
Ye, J., Li, T., Xiong, T., & Janardan, R. (2004) · IEEE/ACM Transactions on Computational Biology and Bioinformatics · doi:10.1109/tcbb.2004.45 · Cited by 183 · cited 2×
“As a dimensionality reduction method, ULDA can reduce class-pair specific decision boundaries to a simple one-dimensional (1-”
MethodAu, A. T. C., & Kirsch, R. F. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.895950 · Cited by 182 · cited 1×
“Using offline approaches, the accuracy of sEMG pattern recognition can be more than 90% through employing various classifiers, such as linear discriminant analysis (LDA) [13], time-delayed artificial neural networks [14], and support vector machines (SVMs) [15].”
MethodSelective Classification for Improved Robustness of Myoelectric Control Under Nonideal Conditions
Scheme, E. J., Englehart, K. B., & Hudgins, B. S. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2113182 · Cited by 172 · cited 2×
“In [25], through 1-versus-1 technology and majority votes, it can be used in the multiclass classification problem.”
BackgroundMethodLorrain, T., Jiang, N., & Farina, D. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-25 · Cited by 165 · cited 1×
“As for the classifier selection, it is well known that LDA in classifying sEMG is with better performance than some other classifiers (e.g., SVM) [24], [25], and there exist few parameters necessary to be selected.”
MethodNg, G. Y. F., Zhang, A. Q., & Li, C. K. (2006) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2006.08.010 · Cited by 147
Li, G., Li, Y., Yu, L., & Geng, Y. (2011) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0265-x · Cited by 109 · cited 1×
“The raw signals were digitally sampled at 1024 Hz, bandpass filtered from 10 to 500 Hz using a digital, four-order Butterworth filter, and a notch filter was used to remove the unwanted line-frequency (50 Hz) [27].”
MethodMechanical suppression of essential tremor
Rocon, E., Manto, M., Pons, J., Camut, S., & Belda, J. M. (2007) · The Cerebellum · doi:10.1080/14734220601103037 · Cited by 68
Estimating arm motion and force using EMG signals: On the control of exoskeletons
Artemiadis, P., & Kyriakopoulos, K. J. (2008) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2008.4650949 · Cited by 21
Cited by
Bi, L., Feleke, A. >., & Guan, C. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.02.011 · Cited by 418
A review of the key technologies for sEMG-based human-robot interaction systems
Li, K., Zhang, J., Wang, L., Zhang, M., Li, J., & Bao, S. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2020.102074 · Cited by 233
Wang, X., Li, X., Wang, J., Fang, X., & Zhu, X. (2016) · Information Sciences · doi:10.1016/j.ins.2015.08.025 · Cited by 183
“A data driven adaptive predictive control [17] has been proposed for the 51 biped robots.”
MethodLearning-Based Motion-Intention Prediction for End-Point Control of Upper-Limb-Assistive Robots
Yang, S., Garg, N. P., Gao, R., Yuan, M., Noronha, B., Ang, W. T., & Accoto, D. (2023) · Sensors · doi:10.3390/s23062998 · Cited by 20
“Physiological signals are widely used as control interfaces for assistive and rehabilitation robots, which can detect the potential intention of motion [11,12].”
Background
Metadata
- Authors
- Li, Z., Wang, B., Sun, F., Yang, C., Xie, Q., & Zhang, W.
- Venue
- IEEE Journal of Biomedical and Health Informatics
- Published
- 2014-05
- Volume
- 18
- Issue
- 3
- Pages
- 1043-1050
- ISSN
- 2168-2194 (ISSN-L)
- 2168-2208
- OpenAlex
- W2115123877
- Cited by
- 197
- References
- 27
- FWCI
- 8.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.