CoChat

Learning-Based Motion-Intention Prediction for End-Point Control of Upper-Limb-Assistive Robots

Open access

The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.

Abstract

The lack of intuitive and active human–robot interaction makes it difficult to use upper-limb-assistive devices. In this paper, we propose a novel learning-based controller that intuitively uses onset motion to predict the desired end-point position for an assistive robot. A multi-modal sensing system comprising inertial measurement units (IMUs), electromyographic (EMG) sensors, and mechanomyography (MMG) sensors was implemented. This system was used to acquire kinematic and physiological signals during reaching and placing tasks performed by five healthy subjects. The onset motion data of each motion trial were extracted to input into traditional regression models and deep learning models for training and testing. The models can predict the position of the hand in planar space, which is the reference position for low-level position controllers. The results show that using IMU sensor with the proposed prediction model is sufficient for motion intention detection, which can provide almost the same prediction performance compared with adding EMG or MMG. Additionally, recurrent neural network (RNN)-based models can predict target positions over a short onset time window for reaching motions and are suitable for predicting targets over a longer horizon for placing tasks. This study’s detailed analysis can improve the usability of the assistive/rehabilitation robots.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/s23062998

Cites

44 of 44 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Overview of the proposed learning-based controller. The onset motion data are acquired from different sensory interfaces. The input features are then computed for four onset time windows of motion. Then, the processed motion samples are given as input to multiple learning-based intention prediction models for end-point prediction. Finally, the target end-point positions will be given as a reference point to the low-level controller for the robot to move.
Figure 1 Overview of the proposed learning-based controller. The onset motion data are acquired from different sensory interfaces. The input features are then computed for four onset time windows of motion. Then, the processed motion samples are given as input to multiple learning-based intention prediction models for end-point prediction. Finally, the target end-point positions will be given as a reference point to the low-level controller for the robot to move.CC BY · PubMed Central
Figure 2 Experimental setup: The subject sat in front of the experimental table. Then, he moved the cup according to the number of the positions indicated on the screen of a laptop.
Figure 2 Experimental setup: The subject sat in front of the experimental table. Then, he moved the cup according to the number of the positions indicated on the screen of a laptop.CC BY · PubMed Central
Figure 3 Schematic of the experimental table: Each red position is made up of a 4 cm radius circular. Twelve magnetic stickers are placed in different locations.
Figure 3 Schematic of the experimental table: Each red position is made up of a 4 cm radius circular. Twelve magnetic stickers are placed in different locations.CC BY · PubMed Central
Figure 4 Data acquisition flow: The IMUs and the EMG and MMG sensors were placed on the upper limb of the participant. The EMG and IMU data were transmitted wirelessly, and the MMG data were captured via a wired connection. A DAQ acquires the data (Quanser PIDe) connected to a PC.
Figure 4 Data acquisition flow: The IMUs and the EMG and MMG sensors were placed on the upper limb of the participant. The EMG and IMU data were transmitted wirelessly, and the MMG data were captured via a wired connection. A DAQ acquires the data (Quanser PIDe) connected to a PC.CC BY · PubMed Central
Figure 5 The input features are calculated within the whole time window of onset movement. The motion data of each subject can be reformed as a single vector.
Figure 5 The input features are calculated within the whole time window of onset movement. The motion data of each subject can be reformed as a single vector.CC BY · PubMed Central
Figure 6 The settled margin of radius error for object’s location. The largest range was chosen to be coincident with the palm-to-wrist length of the 99% of adults, corresponding to 8 cm [42].
Figure 6 The settled margin of radius error for object’s location. The largest range was chosen to be coincident with the palm-to-wrist length of the 99% of adults, corresponding to 8 cm [42].CC BY · PubMed Central
Figure 7 Prediction accuracy of the “reaching” task for different combinations of input features considering all subjects. The performance of the analysis mainly targets the LSTM model. The blue bars represent the results that only use kinematic input features labeled as IMU. The orange bars refer to the physiological features input only, labeled as EMG + MMG. Results with the combinations of input features are shown in green (labeled as all).
Figure 7 Prediction accuracy of the “reaching” task for different combinations of input features considering all subjects. The performance of the analysis mainly targets the LSTM model. The blue bars represent the results that only use kinematic input features labeled as IMU. The orange bars refer to the physiological features input only, labeled as EMG + MMG. Results with the combinations of input features are shown in green (labeled as all).CC BY · PubMed Central
Figure 8 Prediction accuracy of the “placing task” for different combinations of input features for all participants subjects. The LSTM model is the main model to be analyzed in this section. The blue bars represent the results that only use kinematic input features labeled as IMU. The orange bars refer to the physiological features input only, labeled as EMG + MMG. Results with the combinations of input features are shown in green (labeled as all).
Figure 8 Prediction accuracy of the “placing task” for different combinations of input features for all participants subjects. The LSTM model is the main model to be analyzed in this section. The blue bars represent the results that only use kinematic input features labeled as IMU. The orange bars refer to the physiological features input only, labeled as EMG + MMG. Results with the combinations of input features are shown in green (labeled as all).CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 44 references

Research works printed but not linked: 2

  1. Johannes M.S. Bigelow J.D. Burck J.M. Harshbarger S.D. Kozlowski M.V. Van Doren T. An overview of the developmental process for the modular prosthetic limb Johns Hopkins APL Tech. Dig. 2011 30 207 216
  2. Tilley A.R. Henry Dreyfuss Associates. The Measure of Man and Woman: Human Factors in Design John Wiley & Sons Hoboken, NJ, USA 2001

Cited by

See all 20

Metadata

Authors
Yang, S., Garg, N. P., Gao, R., Yuan, M., Noronha, B., Ang, W. T., & Accoto, D.
Affiliations
  • Nanyang Technological University (SG)
  • KU Leuven (BE)
Corresponding author
Yang, Sibo
Venue
Sensors
Publisher
MDPI AG
Published
2023-03-10
Volume
23
Issue
6
Pages
2998
ISSN
1424-8220 (ISSN-L)
OpenAlex
W4323851676
Cited by
20
References
44
Citations by year
2026: 5 · 2025: 3 · 2024: 5 · 2023: 7
FWCI
1.58
Type
journal article
Language
en
Open access
Locations
  • Sensors (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Lirias (submittedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • DR-NTU (Nanyang Technological University) (submittedVersion, cc-by)
Funders
“Intelligent Human–robot interface for upper limb wearable robots” (SERC1922500046)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
Keywords
endpoint control, inertial measurement unit, electromyography, mechanomyography, multimodal sensing, recurrent neural networks, human-robot interaction, rehabilitation robots
MeSH terms
Electromyography, Humans, Motion, Robotics, Intention, Upper Extremity

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Learning-Based Motion-Intention Prediction for End-Point Control of Upper-Limb-Assistive Robots. https://app.cochat.ai/papers/10.3390/s23062998
The paper
Yang, S., Garg, N. P., Gao, R., Yuan, M., Noronha, B., Ang, W. T., & Accoto, D. (2023). Learning-Based Motion-Intention Prediction for End-Point Control of Upper-Limb-Assistive Robots. Sensors. https://doi.org/10.3390/s23062998

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.