Automatic Annotation of Seismocardiogram With High-Frequency Precordial Accelerations
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Seismocardiogram (SCG) is the low-frequency vibrations signal recorded from the chest using accelerometers. Peaks on dorsoventral and sternal SCG correspond to specific cardiac events. Prior research work has shown the potential of extracting such peaks for various types of monitoring and diagnosis applications. However, annotation of these peaks is not a trivial task and complicated in some subjects. In this paper, an automated method is proposed to annotate these peaks. The high-frequency accelerations obtained from the same accelerometer, used to record SCG with, were used to facilitate the annotation of the SCG. Algorithms were developed for detection of isovolumic moment (IM) and aortic valve closure (AC) points of SCG. Four different envelope calculation methods were used: cardiac sound characteristic waveform (CSCW), Shannon, absolute, and Hilbert. The algorithms were evaluated based on a dataset including 18 subjects undergoing lower body negative pressure and were further tested with another dataset, which included 67 subjects. These datasets had been previously manually annotated. The algorithm based on CSCW envelope calculation produced the highest detection accuracy for both IM and AC. The overall CSCW algorithm detection accuracy for the test dataset was 98.7% and 99.1% for the IM and AC points, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855
Systolic Time Intervals in Heart Failure in Man
WEISSLER, A. M., HARRIS, W. S., & SCHOENFELD, C. D. (1968) · Circulation · doi:10.1161/01.cir.37.2.149 · Cited by 1,217
Relationship between Seismocardiogram and Echocardiogram for Events in the Cardiac Cycle
Crow, R. S., Hannan, P., Jacobs, D., Hedquist, L., & Salerno, D. M. (2017) · American Journal of Noninvasive Cardiology · doi:10.1159/000470156 · Cited by 186 · cited 1×
“1) [2].”
Cited by
Wu, H., Yang, G., Zhu, K., Liu, S., Guo, W., Jiang, Z., & Li, Z. (2021) · Advanced Science · doi:10.1002/advs.202001938 · Cited by 395
Definition of Fiducial Points in the Normal Seismocardiogram
Sørensen, K., Schmidt, S. E., Jensen, A. S., Søgaard, P., & Struijk, J. J. (2018) · Scientific Reports · doi:10.1038/s41598-018-33675-6 · Cited by 111
Non-Invasive Wearable Patch Utilizing Seismocardiography for Peri-Operative Use in Surgical Patients
Semiz, B., Carek, A. M., Johnson, J. C., Ahmad, S., Heller, J. A., Vicente, F. G., Caron, S., Hogue, C. W., Etemadi, M., & Inan, O. T. (2021) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.3032938 · Cited by 35
Metadata
- Authors
- Khosrow-khavar, F., Tavakolian, K., Blaber, A. P., Zanetti, J. M., Fazel-Rezai, R., & Menon, C.
- Venue
- IEEE Journal of Biomedical and Health Informatics
- Published
- 2015-07
- Volume
- 19
- Issue
- 4
- Pages
- 1428-1434
- ISSN
- 2168-2194 (ISSN-L)
- 2168-2208
- OpenAlex
- W1990956587
- Cited by
- 90
- References
- 3
- FWCI
- 5.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automatic Annotation of Seismocardiogram With High-Frequency Precordial Accelerations. https://app.cochat.ai/papers/10.1109/jbhi.2014.2360156
- The paper
- Khosrow-khavar, F., Tavakolian, K., Blaber, A. P., Zanetti, J. M., Fazel-Rezai, R., & Menon, C. (2015). Automatic Annotation of Seismocardiogram With High-Frequency Precordial Accelerations. IEEE Journal of Biomedical and Health Informatics. https://doi.org/10.1109/jbhi.2014.2360156
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.