Validation of an Accelerometer to Quantify a Comprehensive Battery of Gait Characteristics in Healthy Older Adults and Parkinson's Disease: Toward Clinical and at Home Use
Open accessThe DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
Abstract
Measurement of gait is becoming important as a tool to identify disease and disease progression, yet to date its application is limited largely to specialist centers. Wearable devices enables gait to be measured in naturalistic environments, however questions remain regarding validity. Previous research suggests that when compared with a laboratory reference, measurement accuracy is acceptable for mean but not variability or asymmetry gait characteristics. Some fundamental reasons for this have been presented, (e.g., synchronization, different sampling frequencies) but to date this has not been systematically examined. The aims of this study were to: 1) quantify a comprehensive range of gait characteristics measured using a single triaxial accelerometer-based monitor; 2) examine outcomes and monitor performance in measuring gait in older adults and those with Parkinson's disease (PD); and 3) carry out a detailed comparison with those derived from an instrumented walkway to account for any discrepancies. Fourteen gait characteristics were quantified in 30 people with incident PD and 30 healthy age-matched controls. Of the 14 gait characteristics compared, agreement between instruments was excellent for four (ICCs 0.913-0.983); moderate for four (ICCs 0.508-0.766); and poor for six characteristics (ICCs 0.637-0.370). Further analysis revealed that differences reflect an increased sensitivity of accelerometry to detect motion, rather than measurement error. This is most likely because accelerometry measures gait as a continuous activity rather than discrete footfall events, per instrumented tools. The increased sensitivity shown for these characteristics will be of particular interest to researchers keen to interpret "real-world" gait data. In conclusion, use of a body-worn monitor is recommended for the measurement of gait but is likely to yield more sensitive data for asymmetry and variability features.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Montreal Cognitive Assessment, MoCA: a brief screening tool for mild cognitive impairment
Nasreddine, Z. S., Phillips, N. A., Bédirian, V., Charbonneau, S., Whitehead, V., Collin, I., Cummings, J. L., & Chertkow, H. (2005) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.2005.53221.x · Cited by 25,553
Parkinsonism: onset, progression, and mortality
Hoehn, M. M., & Yahr, M. D. (1967) · Neurology · doi:10.1212/wnl.17.5.427 · Cited by 12,107
Biomechanics and motor control of human movement
(1990) · Choice Reviews Online · doi:10.5860/choice.28-2135 · Cited by 8,451
Goetz, C. G., Tilley, B. C., Shaftman, S. R., Stebbins, G. T., Fahn, S., Martinez‐Martin, P., Poewe, W., Sampaio, C., Stern, M. B., Dodel, R., et al. (2008) · Movement Disorders · doi:10.1002/mds.22340 · Cited by 7,536
Systematic review of levodopa dose equivalency reporting in Parkinson's disease
Tomlinson, C. L., Stowe, R., Patel, S., Rick, C., Gray, R., & Clarke, C. E. (2010) · Movement Disorders · doi:10.1002/mds.23429 · Cited by 4,219
The Activities-specific Balance Confidence (ABC) Scale
Powell, L. E., & Myers, A. M. (1995) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/50a.1.m28 · Cited by 2,869
The global positioning system and inertial navigation
Farrell, J. A., & Barth, M. (1999) · Virtual Defense Library (Ministerio de Defensa) · Cited by 1,048
Stebbins, G. T., Goetz, C. G., Burn, D. J., Jankovic, J., Khoo, T. K., & Tilley, B. C. (2013) · Movement Disorders · doi:10.1002/mds.25383 · Cited by 932
Assessment of spatio-temporal gait parameters from trunk accelerations during human walking
Zijlstra, W., & Hof, A. L. (2003) · Gait & Posture · doi:10.1016/s0966-6362(02)00190-x · Cited by 870
Normative spatiotemporal gait parameters in older adults
Hollman, J. H., McDade, E. M., & Petersen, R. C. (2011) · Gait & Posture · doi:10.1016/j.gaitpost.2011.03.024 · Cited by 807
Cited by
Technology in Parkinson’s disease: challenges and opportunities
Espay, A. J., Bonato, P., Nahab, F. B., Maetzler, W., Dean, J. M., Klucken, J., Eskofier, B. M., Merola, A., Horak, F., Lang, A. E., et al. (2016) · Movement Disorders · doi:10.1002/mds.26642 · Cited by 654
“TOMs can capture meaningful aspects of function that improve personalized patient care through an intuitive, interconnected, and energy-efficient interface.(56,57)”
BackgroundHow Wearable Sensors Can Support Parkinson's Disease Diagnosis and Treatment: A Systematic Review
Rovini, E., Maremmani, C., & Cavallo, F. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00555 · Cited by 426
Free‐living monitoring of Parkinson's disease: Lessons from the field
Del Din, S., Godfrey, A., Mazzà, C., Lord, S., & Rochester, L. (2016) · Movement Disorders · doi:10.1002/mds.26718 · Cited by 370
Self-citationDel Din, S., Godfrey, A., Galna, B., Lord, S., & Rochester, L. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0154-5 · Cited by 349
Self-citationKobsar, D., Charlton, J. M., Tse, C. T. F., Esculier, J.-F., Graffos, A., Krowchuk, N. M., Thatcher, D., & Hunt, M. A. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00685-3 · Cited by 305
Human Gait Analysis in Neurodegenerative Diseases: A Review
Cicirelli, G., Impedovo, D., Dentamaro, V., Marani, R., Pirlo, G., & D'Orazio, T. R. (2022) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2021.3092875 · Cited by 231
Hillel, I., Gazit, E., Nieuwboer, A., Avanzino, L., Rochester, L., Cereatti, A., Croce, U. D., Rikkert, M. O., Bloem, B. R., Pelosin, E., et al. (2019) · European Review of Aging and Physical Activity · doi:10.1186/s11556-019-0214-5 · Cited by 228
“The data analysis of the daily-living recordings included two stages: 1) Detection of all 30-s walking bouts [58]; and 2) Determination of the gait features in each bout, using the same algorithms as those used for in-lab testing.”
MethodSelf-citationGodinho, C., Domingos, J., Cunha, G., Santos, A. T., Fernandes, R. M., Abreu, D., Gonçalves, N., Matthews, H., Isaacs, T., Duffen, J., et al. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0136-7 · Cited by 226
From A to Z: Wearable technology explained
Godfrey, A., Hetherington, V., Shum, H., Bonato, P., Lovell, N. H., & Stuart, S. (2018) · Maturitas · doi:10.1016/j.maturitas.2018.04.012 · Cited by 223
Self-citationGait analysis with wearables predicts conversion to Parkinson disease
Del Din, S., Elshehabi, M., Galna, B., Hobert, M. A., Warmerdam, E., Suenkel, U., Brockmann, K., Metzger, F., Hansen, C., Berg, D., et al. (2019) · Annals of Neurology · doi:10.1002/ana.25548 · Cited by 208
“To estimate a value for step velocity, we utilized the simple ratio between step distance (length) and step time.(34) To calculate variability characteristics (eg, step time variability), the standard deviation (SD) from all steps (left and right combined) was calculated.”
MethodInfluentialSelf-citationMeasuring Parkinson's disease over time: The real‐world within‐subject reliability of the MDS‐UPDRS
Evers, L. J. W., Krijthe, J. H., Meinders, M. J., Bloem, B. R., & Heskes, T. M. (2019) · Movement Disorders · doi:10.1002/mds.27790 · Cited by 199
Del Din, S., Galna, B., Godfrey, A., Bekkers, E. M. J., Pelosin, E., Nieuwhof, F., Mirelman, A., Hausdorff, J. M., & Rochester, L. (2019) · The Journals of Gerontology: Series A · doi:10.1093/gerona/glx254 · Cited by 194
“Due to their brief, subjective and sporadic nature, these approaches may not fully capture everyday falls risk and therefore may be suboptimal (1, 6).”
Self-citationAssessing Gait in Parkinson’s Disease Using Wearable Motion Sensors: A Systematic Review
Brognara, L., Palumbo, P., Grimm, B., & Palmerini, L. (2019) · Diseases · doi:10.3390/diseases7010018 · Cited by 189
“[32] 30 1–3: 1 (8), 2(20), 3 (2) x 1 x x x x x x x”
Storm, F. A., Buckley, C. J., & Mazzà, C. (2016) · Gait & Posture · doi:10.1016/j.gaitpost.2016.08.012 · Cited by 182
“Among activities of daily living, gait is a major marker of disease progression [1], and the step-by-step determination of gait parameters is required for the analysis and characterization of quasi-periodic motions [2], both in terms of absolute values and of their variability [3].”
BackgroundClinical and methodological challenges for assessing freezing of gait: Future perspectives
Mancini, M., Bloem, B. R., Horak, F. B., Lewis, S. J. G., Nieuwboer, A., & Nonnekes, J. (2019) · Movement Disorders · doi:10.1002/mds.27709 · Cited by 173
Gait analysis in neurological populations: Progression in the use of wearables
Celik, Y., Stuart, S., Woo, W. L., & Godfrey, A. (2021) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2020.11.005 · Cited by 167
“PD [121, 141], stroke [126, 135], AD [145, 146], MS [154, 249], CA [158, 159], HD [167, 168]).”
BackgroundResultSelf-citationWearable sensor-based objective assessment of motor symptoms in Parkinson’s disease
Ossig, C., Antonini, A., Buhmann, C., Classen, J., Csoti, I., Falkenburger, B., Schwarz, M., Winkler, J., & Storch, A. (2016) · Journal of Neural Transmission · doi:10.1007/s00702-015-1439-8 · Cited by 164
Use of wearable sensor technology in gait, balance, and range of motion analysis
Díaz, S., Stephenson, J. B., & Labrador, M. A. (2019) · Applied Sciences · doi:10.3390/app10010234 · Cited by 132
“[48] 2015 Quantify a comprehensive range of gait parameters using a single tri-axial accelerometer.”
BackgroundMethodInfluentialHsu, W.-C., Sugiarto, T., Lin, Y.-J., Yang, F.-C., Lin, Z.-Y., Sun, C.-T., Hsu, C.-L., & Chou, K.-N. (2018) · Sensors · doi:10.3390/s18103397 · Cited by 101
“in 2016 [1] applied wearable sensors for Parkinson Disease’s (PD) subjects and healthy older adults.”
BackgroundFit‐for‐Purpose Biometric Monitoring Technologies: Leveraging the Laboratory Biomarker Experience
Godfrey, A., Vandendriessche, B., Bakker, J. P., Fitzer‐Attas, C., Gujar, N., Hobbs, M., Liu, Q., Northcott, C. A., Parks, V., Wood, W. A., et al. (2021) · Clinical and Translational Science · doi:10.1111/cts.12865 · Cited by 60
Self-citationPalmerini, L., Reggi, L., Bonci, T., Del Din, S., Micó-Amigo, M. E., Salis, F., Bertuletti, S., Caruso, M., Cereatti, A., Gazit, E., et al. (2023) · Scientific Data · doi:10.1038/s41597-023-01930-9 · Cited by 52
Self-citationRoussos, G., Herrero, T. R., Hill, D. L., Dowling, A. V., L. T. M. Müller, M., Evers, L. J. W., Burton, J., Derungs, A., Fisher, K., Kilambi, K. P., et al. (2022) · npj Digital Medicine · doi:10.1038/s41746-022-00643-4 · Cited by 28
“31 .”
Taylor, L. M., Parsons, J., Moyes, S. A., Binns, E., Cavadino, A., Taylor, D., Lord, S., Del Din, S., Klenk, J., Rochester, L., et al. (2024) · Journal of the American Medical Directors Association · doi:10.1016/j.jamda.2023.10.022 · Cited by 21
Self-citation
Metadata
- Authors
- Del Din, S., Godfrey, A., & Rochester, L.
- Venue
- IEEE Journal of Biomedical and Health Informatics
- Published
- 2016-05
- Volume
- 20
- Issue
- 3
- Pages
- 838-847
- ISSN
- 2168-2194 (ISSN-L)
- 2168-2208
- OpenAlex
- W1992762558
- Cited by
- 363
- References
- 47
- FWCI
- 62.50
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.