99% Efficient 10 kV SiC-Based 7 kV/400 V DC Transformer for Future Data Centers
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
The power supply chain of data centers from the medium voltage (MV) utility grid down to the chip-level voltage consists of many series connected power conversion stages and accordingly shows a relatively low efficiency. Solid-state transformers (SSTs) could improve the efficiency by substantially reducing the number of power conversion stages and/or directly interfacing the MV ac grid to a 400 V dc bus, from where server racks with a power consumption of several tens of kilowatts could be supplied by individual SSTs. The recent development of SiC MOSFETs with a blocking voltage of 10 kV enables the realization of a simple and, hence, highly reliable two-stage SST topology, consisting of an ac/dc power factor correction rectifier and a subsequent isolated dc/dc converter. In this context, an isolated 25 kW, 48 kHz, 7 kV to 400 V series resonant dc/dc converter based on 10 kV SiC MOSFETs is realized and tested in this paper. To achieve zero voltage switching of all MOSFETs, a special modulation scheme to actively control the amount of the switched magnetizing current on the MV- and low voltage-sides is implemented. Furthermore, the design of all main components and, especially, the electrical insulation of the employed medium-frequency transformer are discussed in detail. Calorimetric efficiency measurements show that a full-load efficiency of 99.0% is achieved, while the power density reaches 3.8 kW/L (63 W/in3).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Venkatachalam, K., Sullivan, C. R., Abdallah, T., & Tacca, H. (2003) · 2002 IEEE Workshop on Computers in Power Electronics, 2002. Proceedings. · doi:10.1109/cipe.2002.1196712 · Cited by 1,145 · cited 1×
“The simulations include high-frequency effects in the litz wire [32]–[34], the fringing field of the air gap [35], and the effects of the nonsinusoidal magnetic flux by calculating the core losses via iGSE [36].”
MethodOptimal choice for number of strands in a litz-wire transformer winding
Sullivan, C. R. (1999) · IEEE Transactions on Power Electronics · doi:10.1109/63.750181 · Cited by 558
Leibl, M., Ortiz, G., & Kolar, J. W. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2016.2623679 · Cited by 306
Self-citationSolid-State-Transformers: Key Components of Future Traction and Smart Grid Systems
Kolar, J. W., & Ortiz, G. (2014) · International Power Electronics Conference (IPEC) · Cited by 242
Self-citationHigh-Frequency Transformer Design for Modular Power Conversion From Medium-Voltage AC to 400 VDC
Zhao, S., Li, Q., Lee, F. C., & Li, B. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2774440 · Cited by 231
Optimum Number of Cascaded Cells for High-Power Medium-Voltage AC–DC Converters
Huber, J. E., & Kolar, J. W. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2016.2605702 · Cited by 191
Self-citation99.1% Efficient 10 kV SiC-Based Medium-Voltage ZVS Bidirectional Single-Phase PFC AC/DC Stage
Rothmund, D., Guillod, T., Bortis, D., & Kolar, J. W. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2886140 · Cited by 140
Self-citationData Center Challenges and Their Power Electronics
Krein, P. T. (2017) · CPSS Transactions on Power Electronics and Applications · doi:10.24295/cpsstpea.2017.00005 · Cited by 132
Calorimetric Power Loss Measurement for Highly Efficient Converters
Christen, D., Badstuebner, U., Biela, J., & Kolar, J. W. (2010) · International Power Electronics Conference (IPEC) · doi:10.1109/ipec.2010.5544503 · Cited by 126
Self-citationHighly Compact Isolated Gate Driver With Ultrafast Overcurrent Protection for 10 kV SiC MOSFETs
Rothmund, D., Bortis, D., & Kolar, J. W. (2018) · CPSS Transactions on Power Electronics and Applications · doi:10.24295/cpsstpea.2018.00028 · Cited by 123
Self-citation
Cited by
Extreme Fast Charging of Electric Vehicles: A Technology Overview
Tu, H., Feng, H., Srdic, S., & Lukic, S. (2019) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2019.2958709 · Cited by 898
Li, Z., Hsieh, E., Li, Q., & Lee, F. C. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3279030 · Cited by 111
Soft-Switching Solid-State Transformer With Reduced Conduction Loss
Zheng, L., Kandula, R. P., & Divan, D. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3030795 · Cited by 105
“In [5], the semiconductor conduction loss accounts for more than 50% of the total loss of the dc–dc SST at full power.”
BackgroundZheng, L., Han, X., An, Z., Kandula, R. P., Kandasamy, K., Saeedifard, M., & Divan, D. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3066908 · Cited by 84
Zheng, L., Kandula, R. P., & Divan, D. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3101482 · Cited by 85
Li, Z., Hsieh, Y.-H., Li, Q., Lee, F. C., & Ahmed, M. H. (2020) · 2020 IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce44975.2020.9236384 · Cited by 71
A Three-Phase Isolated Building Block for High-Power Medium-Voltage Grid Applications
Gomez, R. A., Porras, D. A., Oggier, G. G., Balda, J. C., & Zhao, Y. (2024) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2023.3311775 · Cited by 16
“…made in higher blocking voltage SiC MOSFETs, where research has shown the potential of 10 and 15 kV SiC devices in applications like data centers [7], [8], [9], solid-state transformers (SSTs) [10], [11], [12], [13], and fast chargers [14], [15] avoiding the need for highly complex multilevel…”
Background
Metadata
- Authors
- Rothmund, D., Guillod, T., Bortis, D., & Kolar, J. W.
- Venue
- IEEE Journal of Emerging and Selected Topics in Power Electronics
- Published
- 2019-06
- Volume
- 7
- Issue
- 2
- Pages
- 753-767
- ISSN
- 2168-6777 (ISSN-L)
- 2168-6785
- OpenAlex
- W2904921824
- Cited by
- 315
- References
- 32
- FWCI
- 8.84
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.