Isolated and Nonisolated DC-to-DC Converters for Medium-Voltage DC Networks: A Review
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Medium-voltage dc (MVdc) technology is a promising solution to avoid the installation of new ac networks. MVdc can provide optimum integration of large-scale renewable energy sources, the interconnection of different voltage levels of dc and ac grids with the ancillary services. The development in MVdc depends significantly on the dc–dc converters. Such converters support the modern trends of utilizing medium-frequency transformers in power networks. Research on isolated converters technology is in its infancy and limited by the conversion ratio and component ratings. Besides, there is no standards exist covering specific aspects of isolated converter product. Thus, a review of such converters is needed. This work presents, for the first time, a review of the dc–dc power converter families in MVdc grids, including the leading families that are isolated and nonisolated converters, as well as other subfamilies comparing the specifications and characteristics. Also, the applications of these converters are provided by focusing on the essential requirements for each application.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zhao, B., Song, Q., Liu, W., & Sun, Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2289913 · Cited by 1,886
Review of the Impact of Vehicle-to-Grid Technologies on Distribution Systems and Utility Interfaces
Yilmaz, M., & Krein, P. T. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2227500 · Cited by 1,024
Zhao, B., Yu, Q., & Sun, W. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2180928 · Cited by 932
Efficiency-Optimized High-Current Dual Active Bridge Converter for Automotive Applications
Krismer, F., & Kolar, J. W. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2112312 · Cited by 747
Dong, D., Agamy, M., Bebic, J. Z., Chen, Q., & Mandrusiak, G. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2896046 · Cited by 154
A Zero-Current-Switching High Conversion Ratio Modular Multilevel DC–DC Converter
Li, Y., Lyu, X., & Cao, D. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2016.2623794 · Cited by 56
Yang, H., Saeedifard, M., & Yazdani, A. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2850035 · Cited by 52 · cited 9×
“Furthermore, it is possible to combine both types of SMs in the configuration of the converter to take their advantages [80].”
BackgroundMethodInfluential
Cited by
Acharige, S. S. G., Haque, M. E., Arif, M. T., Hosseinzadeh, N., Hasan, K. N., & Oo, A. M. T. (2023) · IEEE Access · doi:10.1109/access.2023.3267164 · Cited by 590
Zheng, L., Kandula, R. P., & Divan, D. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3101482 · Cited by 85
Assessment of industrial-scale green hydrogen production using renewable energy
Hassan, Q., Algburi, S., Sameen, A. Z., & Salman, H. M. (2024) · Proceedings of the Institution of Mechanical Engineers Part A Journal of Power and Energy · doi:10.1177/09576509231219339 · Cited by 22
“The performance or ef fi ciency of this converter can be determined using the methods described in references 34,35.”
Method
Metadata
- Authors
- Alhurayyis, I., Elkhateb, A., & Morrow, J.
- Venue
- IEEE Journal of Emerging and Selected Topics in Power Electronics
- Published
- 2021-12
- Volume
- 9
- Issue
- 6
- Pages
- 7486-7500
- ISSN
- 2168-6777 (ISSN-L)
- 2168-6785
- OpenAlex
- W3091602847
- Cited by
- 224
- References
- 7
- FWCI
- 8.02
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.