The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Real-Time Signal Quality-Aware ECG Telemetry System for IoT-Based Health Care Monitoring
Abstract
In this paper, we propose a novel signal quality-aware Internet of Things (IoT)-enabled electrocardiogram (ECG) telemetry system for continuous cardiac health monitoring applications. The proposed quality-aware ECG monitoring system consists of three modules: 1) ECG signal sensing module; 2) automated signal quality assessment (SQA) module; and 3) signal-quality aware (SQAw) ECG analysis and transmission module. The main objectives of this paper are: design and development of a light-weight ECG SQA method for automatically classifying the acquired ECG signal into acceptable or unacceptable class and real-time implementation of proposed IoT-enabled ECG monitoring framework using ECG sensors, Arduino, Android phone, Bluetooth, and cloud server. The proposed framework is tested and validated using the ECG signals taken from the MIT-BIH arrhythmia and Physionet challenge databases and the real-time recorded ECG signals under different physical activities. Experimental results show that the proposed SQA method achieves promising results in identifying the unacceptable quality of ECG signals and outperforms existing methods based on the morphological and RR interval features and machine learning approaches. This paper further shows that the transmission of acceptable quality of ECG signals can significantly improve the battery lifetime of IoT-enabled devices. The proposed quality-aware IoT paradigm has great potential for assessing clinical acceptability of ECG signals in improvement of accuracy and reliability of unsupervised diagnosis system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The impact of the MIT-BIH Arrhythmia Database
Moody, G. B., & Mark, R. G. (2001) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.932724 · Cited by 4,812
An IoT-Aware Architecture for Smart Healthcare Systems
Catarinucci, L., de Donno, D., Mainetti, L., Palano, L., Patrono, L., Stefanizzi, M. L., & Tarricone, L. (2015) · IEEE Internet of Things Journal · doi:10.1109/jiot.2015.2417684 · Cited by 1,167
RFID Technology for IoT-Based Personal Healthcare in Smart Spaces
Amendola, S., Lodato, R., Manzari, S., Occhiuzzi, C., & Marrocco, G. (2014) · IEEE Internet of Things Journal · doi:10.1109/jiot.2014.2313981 · Cited by 608
Rangayyan, R. M. (2001) · Institute of Electrical and Electronics Engineers eBooks · doi:10.1109/9780470544204 · Cited by 422
A novel method for detecting R-peaks in electrocardiogram (ECG) signal
Manikandan, M. S., & Soman, K. P. (2012) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2011.03.004 · Cited by 393
Orphanidou, C., Bonnici, T., Charlton, P., Clifton, D., Vallance, D., & Tarassenko, L. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2338351 · Cited by 368
He, D., & Zeadally, S. (2015) · IEEE Internet of Things Journal · doi:10.1109/jiot.2014.2360121 · Cited by 327
Energy Efficient Medium Access Protocol for Wireless Medical Body Area Sensor Networks
Omeni, O., Wong, A. C. W., Burdett, A. J., & Toumazou, C. (2008) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2008.2003431 · Cited by 322
ECG Signal Quality During Arrhythmia and Its Application to False Alarm Reduction
Behar, J., Oster, J., Li, Q., & Clifford, G. D. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2240452 · Cited by 293
Signal quality indices and data fusion for determining clinical acceptability of electrocardiograms
Clifford, G. D., Behar, J., Li, Q., & Rezek, I. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/9/1419 · Cited by 292
Toward Automatic Activity Classification and Movement Assessment During a Sports Training Session
Ahmadi, A., Mitchell, E., Richter, C., Destelle, F., Gowing, M., O'Connor, N. E., & Moran, K. (2014) · IEEE Internet of Things Journal · doi:10.1109/jiot.2014.2377238 · Cited by 134
QRS detection based ECG quality assessment
Hayn, D., Jammerbund, B., & Schreier, G. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/9/1449 · Cited by 106
Multicolumn bidirectional long short-term memory for mobile devices-based human activity recognition
Tao, D., Wen, Y., & Hong, R. (2016) · IEEE Internet of Things Journal · doi:10.1109/jiot.2016.2561962 · Cited by 83
MS-QI: A Modulation Spectrum-Based ECG Quality Index for Telehealth Applications
Tobón, D. P., Falk, T. H., & Maier, M. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2355135 · Cited by 81
Automatic ECG quality scoring methodology: mimicking human annotators
Johannesen, L., & Galeotti, L. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/9/1479 · Cited by 71
Data-driven event triggering for IoT applications
Kolios, P., Panayiotou, C., Ellinas, G., & Polycarpou, M. (2016) · IEEE Internet of Things Journal · doi:10.1109/jiot.2016.2564428 · Cited by 60
Computer algorithms for evaluating the quality of ECGs in real time
Xia, H., García, G., McBride, J. C., Sullivan, A., Bock, T. D., Bains, J., Wortham, D. C., & Zhao, X. (2011) · Computing in cardiology · Cited by 54
Satija, U., Ramkumar, B., & Manikandan, M. S. (2016) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2016.7471781 · Cited by 48
Self-citationRule-based methods for ECG quality control
Moody, B. (2011) · Cited by 45
Quality estimation of the electrocardiogram using cross-correlation among leads
Morgado, E., Alonso‐Atienza, F., Mozos, R. S., Barquero‐Pérez, Ó., Silva, I., Ramos, J., & Mark, R. G. (2015) · BioMedical Engineering OnLine · doi:10.1186/s12938-015-0053-1 · Cited by 39
Tsirmpas, C., Αναστασίου, Α., Bountris, P., & Koutsouris, D. (2015) · IEEE Internet of Things Journal · doi:10.1109/jiot.2015.2428307 · Cited by 39
ECG quality assessment for patient empowerment in mHealth applicationsPreprint
Hayn, Jammerbund, & Schreier, G. (2011) · Cited by 39
RadioSense: Exploiting Wireless Communication Patterns for Body Sensor Network Activity Recognition
Qi, X., Zhou, G., Li, Y., & Ge, P. (2012) · IEEE Real-Time Systems Symposium (RTSS) · doi:10.1109/rtss.2012.62 · Cited by 38
Electrocardiogram signal quality assessment using an artificially reconstructed target lead
Naseri, H., & Homaeinezhad, M. R. (2014) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2013.875163 · Cited by 36
Assisting Physical (Hydro)Therapy With Wireless Sensors Networks
Alves, R. C. A., Gabriel, L. B., de Oliveira, B. T., Margi, C. B., & dos Santos, F. C. L. (2015) · IEEE Internet of Things Journal · doi:10.1109/jiot.2015.2394493 · Cited by 35
A simple method for detection and classification of ECG noises for wearable ECG monitoring devices
Satija, U., Ramkumar, B., & Manikandan, M. S. (2015) · 2015 2nd International Conference on Signal Processing and Integrated Networks (SPIN) · doi:10.1109/spin.2015.7095425 · Cited by 34
Self-citationSignal quality and false myocardial ischemia alarms in ambulatory electrocardiograms
Quesnel, P. X., Chan, A. D. C., & Yang, H. (2014) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2014.6860078 · Cited by 26
A robust sparse signal decomposition framework for baseline wander removal from ECG signal
Satija, U., Ramkumar, B., & Manikandan, M. S. (2016) · IEEE Region 10 Conference (TENCON) · doi:10.1109/tencon.2016.7848477 · Cited by 24
Self-citationImprovement of ECG signal quality measurement using correlation and diversity-based approaches
Martinez-Tabares, F. J., Espinosa-Oviedo, J., & Castellanos-Dominguez, G. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346916 · Cited by 22
Electrocardiogram quality classification based on robust best subsets linear prediction error
Noponen, K., Karsikas, M., Tiinanen, S., Kortelainen, J., Huikuri, H. V., & Seppänen, T. (2011) · Computing in cardiology · Cited by 22
Robust cardiac event change detection method for long‐term healthcare monitoring applications
Satija, U., Ramkumar, B., & Manikandan, M. S. (2016) · Healthcare Technology Letters · doi:10.1049/htl.2015.0062 · Cited by 21
Self-citationLight-Weight Online Unsupervised Posture Detection by Smartphone Accelerometer
Yurur, O., Liu, C. H., & Moreno, W. A. (2015) · IEEE Internet of Things Journal · doi:10.1109/jiot.2015.2404929 · Cited by 20
Mortazavi, B. J., Pourhomayoun, M., Ghasemzadeh, H. G., Jafari, R., Roberts, C. K., & Sarrafzadeh, M. (2014) · IEEE Internet of Things Journal · doi:10.1109/jiot.2014.2364407 · Cited by 20
The Rebirth of One-Time Pads—Secure Data Transmission from BAN to Sink
Büsching, F., & Wolf, L. C. (2014) · IEEE Internet of Things Journal · doi:10.1109/jiot.2014.2378783 · Cited by 15
Transfer Learning in Body Sensor Networks Using Ensembles of Randomized Trees
Casale, P., Altini, M., & Amft, O. (2015) · IEEE Internet of Things Journal · doi:10.1109/jiot.2015.2389335 · Cited by 13
Cited by
The Future of Healthcare Internet of Things: A Survey of Emerging Technologies
Qadri, Y. A., Nauman, A., Zikria, Y. B., Vasilakos, A. V., & Kim, S. W. (2020) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2020.2973314 · Cited by 840
A Survey on Internet of Things and Cloud Computing for Healthcare
Dang, L. M., Piran, M. J., Han, D., Min, K., & Moon, H. (2019) · Electronics · doi:10.3390/electronics8070768 · Cited by 640
Internet of Things: A survey of enabling technologies in healthcare and its applications
Dhanvijay, M. M., & Patil, S. C. (2019) · Computer Networks · doi:10.1016/j.comnet.2019.03.006 · Cited by 374
ECG Monitoring Systems: Review, Architecture, Processes, and Key Challenges
Serhani, M. A., T. El Kassabi, H., Ismail, H., & Nujum Navaz, A. (2020) · Sensors · doi:10.3390/s20061796 · Cited by 357
Popli, S., Jha, R. K., & Jain, S. (2019) · IEEE Access · doi:10.1109/access.2018.2881533 · Cited by 325
Metadata
- Authors
- Satija, U., Ramkumar, B., & Sabarimalai Manikandan, M.
- Venue
- IEEE Internet of Things Journal
- Published
- 2017-06
- Volume
- 4
- Issue
- 3
- Pages
- 815-823
- ISSN
- 2327-4662 (ISSN-L)
- OpenAlex
- W2587967768
- Cited by
- 370
- References
- 35
- FWCI
- 23.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.