Modeling, Fabrication, and Characterization of Piezoelectric Micromachined Ultrasonic Transducer Arrays Based on Cavity SOI Wafers
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
This paper presents high fill-factor piezoelectric micromachined ultrasonic transducer (PMUT) arrays fabricated via a novel process using cavity SOI wafers. The simple three-mask fabrication process enables smaller diameter PMUTs (25 μm) and finer pitch than previous processes requiring through-wafer etching. PMUTs were fabricated with diameters from 25 to 50 μm, resulting in center frequencies from 13 to 55 MHz in air. Two types of devices, having different piezoelectric layers, lead zirconium titanate (PZT), and aluminum nitride (AlN), were fabricated and characterized. Comparing 50-μm diameter devices, the PZT PMUTs show large dynamic displacement sensitivity of 316 nm/V at 11 MHz in air, which is ~20x higher than that of the AlN PMUTs. Electrical impedance measurements of the PZT PMUTs show high electromechanical coupling k2t= 12.5% and 50-Ω electrical impedance that is well-matched to typical interface circuits. Immersion tests were conducted on PZT PMUT arrays. The fluid-immersed acoustic pressure generated by an unfocused 9 × 9 array of 40-μm diameter, 10-MHz PZT PMUTs, measured with a needle hydrophone 1.2 mm away from the array, was 58 kPa with a 25 Vpp input. Beam forming based on electronic phase control produced a narrow, 150-μm diameter, focused beam over a depth of focus >0.2 mm and increased the pressure to 450 kPa with 18 Vpp input.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kinsler, L. E., Frey, A. R., & Bennett, G. S. (1951) · American Journal of Physics · doi:10.1119/1.1932798 · Cited by 3,375
Thin Film Piezoelectrics for MEMS
Trolier-McKinstry, S., & Muralt, P. (2004) · Journal of Electroceramics · doi:10.1023/b:jecr.0000033998.72845.51 · Cited by 1,023
Thin Plates and Shells: Theory, Analysis, and Applications
Ventsel, Krauthammer, & Carrera (2002) · Applied Mechanics Reviews · doi:10.1115/1.1483356 · Cited by 1,011 · cited 1×
“The out of plane deflection of an edge-clamped circular plate with uniform pressure load, p, is [21]:”
BackgroundFundamentals of Physical Acoustics
Blackstock, D. T., & Atchley, A. A. (2001) · The Journal of the Acoustical Society of America · doi:10.1121/1.1354982 · Cited by 761
Surface micromachined capacitive ultrasonic transducers
Ladabaum, I., Jin, X., Soh, H. T., Atalar, A., & Khuri-Yakub, B. T. (1998) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.677612 · Cited by 581 · cited 1×
“two-dimensional (2D) transducer arrays needed for 3D imaging [6], [7].”
BackgroundPiezoelectric micromachined ultrasonic transducers based on PZT thin films
Muralt, P., Ledermann, N., Paborowski, J., Barzegar, A., Gentil, S., Belgacem, B., Petitgrand, S., Bosseboeuf, A., & Setter, N. (2005) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2005.1563270 · Cited by 332
Capacitive micromachined ultrasonic transducers for medical imaging and therapy
Khuri-Yakub, B. T., & Oralkan, Ö. (2011) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/21/5/054004 · Cited by 332 · cited 1×
“bandwidth, low cost, easy fabrication of large arrays with compact designs, and easy integration with supporting electronics [11]–[14].”
BackgroundLong, M. (2014) · Architectural Acoustics · doi:10.1016/b978-0-12-398258-2.00002-7 · Cited by 272
Micromachined high frequency ferroelectric sonar transducers
Bernstein, J. J., Finberg, S. L., Houston, K., Niles, L. C., Chen, H. D., Cross, L. E., Li, K. K., & Udayakumar, K. (1997) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.655620 · Cited by 261
Development of piezoelectric micromachined ultrasonic transducers
Akasheh, F., Myers, T., Fraser, J. D., Bose, S., & Bandyopadhyay, A. (2004) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2003.11.022 · Cited by 253 · cited 2×
“two-dimensional (2D) transducer arrays needed for 3D imaging [6], [7].”
Background
Cited by
Ingestible electronics for diagnostics and therapy
Steiger, C., Abramson, A., Nadeau, P., Chandrakasan, A. P., Langer, R., & Traverso, G. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0070-3 · Cited by 274
Micromachined Resonators: A Review
Abdolvand, R., Bahreyni, B., Lee, J., & Nabki, F. (2016) · Micromachines · doi:10.3390/mi7090160 · Cited by 230
“Membrane resonators are commonly used to implement micromachined ultrasonic transducers (MUTs) [53,54].”
Thin-film PMUTs: a review of over 40 years of research
Roy, K., Lee, J. E.-Y., & Lee, C. (2023) · Microsystems & Nanoengineering · doi:10.1038/s41378-023-00555-7 · Cited by 180
Birjis, Y., Swaminathan, S., Nazemi, H., Raj, G. C. A., Munirathinam, P., Abu-Libdeh, A., & Emadi, A. (2022) · Sensors · doi:10.3390/s22239151 · Cited by 84
“Hence, to increase acoustic efficiency of PMUT, the fill factor of the array needs to be maximized [60].”
BackgroundMethodInfluential
Metadata
- Authors
- Lu, Y., & Horsley, D. A.
- Venue
- Journal of Microelectromechanical Systems
- Published
- 2015-08
- Volume
- 24
- Issue
- 4
- Pages
- 1142-1149
- ISSN
- 1057-7157 (ISSN-L)
- 1941-0158
- OpenAlex
- W2019123650
- Cited by
- 194
- References
- 22
- FWCI
- 14.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).