Current Sensing Techniques: A Review
The DOI matches its Crossref record; 62 of the 63 references it cites were found in a registry or an index.
Abstract
This paper provides a thorough review of state-of-the-art current sensing techniques. It catalogues the current sensors according to the underlying physical principle in order to point out their strengths and weaknesses.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The measurement range is limited by the accuracy of the voltage measurement [10,31].”
From Battery Management System Hardware Concepts: An Overview (2018) · cites this paper as [10]
In the citing paper
“However, solely relying on coulomb counting for precise SOC determination appears risky because current sensors are also non-ideal systems that underlie a certain drift-, offset-and temperature-error (see e.g., [10]).”
From Battery Management System Hardware Concepts: An Overview (2018) · cites this paper as [10]
In the citing paper
“Furthermore, high load current bypassing the low-side monitor-for instance caused by accidental short-circuit-cannot be detected [10].”
From Battery Management System Hardware Concepts: An Overview (2018) · cites this paper as [10]
In the citing paper
“A further drawback of this measuring method is that the output signal of a Hall effect sensor has a large temperature drift [10] that needs to be compensated in the sensor module or the signal processing chain.”
From Battery Management System Hardware Concepts: An Overview (2018) · cites this paper as [10]
Citations
Cites
Giant Magnetoresistance of (001)Fe/(001)Cr Magnetic Superlattices
Baibich, M. N., Broto, J. M., Fert, A., Van Dau, F. N., Petroff, F., Etienne, P., Creuzet, G., Friederich, A., & Chazelas, J. (1988) · Physical Review Letters · doi:10.1103/physrevlett.61.2472 · Cited by 9,415 · cited 1×
“The discoverers Gruenberg and Fert received the 2007 Physics Nobel Prize for this work [48], [49].”
BackgroundEnhanced magnetoresistance in layered magnetic structures with antiferromagnetic interlayer exchange
Binasch, G., Grünberg, P., Saurenbach, F., & Zinn, W. (1989) · Physical Review B · doi:10.1103/physrevb.39.4828 · Cited by 4,347 · cited 1×
“The discoverers Gruenberg and Fert received the 2007 Physics Nobel Prize for this work [48], [49].”
BackgroundGiant magnetic tunneling effect in Fe/Al2O3/Fe junction
Miyazaki, T., & Tezuka, N. (1995) · Journal of Magnetism and Magnetic Materials · doi:10.1016/0304-8853(95)90001-2 · Cited by 1,917 · cited 1×
“Using the TMR effect, resistance changes up to 230% at room temperature have been reported [59], [60].”
BackgroundReview of the present status of optical fiber sensors
Lee, B. (2003) · Optical Fiber Technology · doi:10.1016/s1068-5200(02)00527-8 · Cited by 1,736 · cited 4×
“35, that allows it to generate a linear output from the detected signal by building the ratio of the first and second harmonic amplitude level [62], [70].”
BackgroundMethodInfluentialMagnetic sensors and their applications
Lenz, J., & Edelstein, S. (2006) · IEEE Sensors Journal · doi:10.1109/jsen.2006.874493 · Cited by 1,312 · cited 5×
“It has to be noted that this is just one example of a structure that exhibits the GMR effect [33], [50].”
BackgroundInfluentialInductance Calculations Working Formulas and Tables
Snyder, J. N., & Grover, F. C. (1964) · Mathematics of Computation · doi:10.2307/2003443 · Cited by 1,309 · cited 1×
“In reality, the parasitic inductance is determined by the mutual inductance between loop built by the sense wires and the loop built by the main current [1].”
Background230% room-temperature magnetoresistance in CoFeB∕MgO∕CoFeB magnetic tunnel junctions
Djayaprawira, D. D., Tsunekawa, K., Nagai, M., Maehara, H., Yamagata, S., Watanabe, N., Yuasa, S., Suzuki, Y., & Ando, K. (2005) · Applied Physics Letters · doi:10.1063/1.1871344 · Cited by 967 · cited 1×
“Using the TMR effect, resistance changes up to 230% at room temperature have been reported [59], [60].”
BackgroundFiber Optic Sensors: An Introduction for Engineers and Scientists
(2011) · Wiley eBooks · doi:10.1002/9781118014103 · Cited by 783 · cited 1×
“Linear birefringent material behaves vice versa [61].”
Giant magnetic field dependent impedance of amorphous FeCoSiB wire
Beach, R. S., & Berkowitz, A. E. (1994) · Applied Physics Letters · doi:10.1063/1.111170 · Cited by 650
Primdahl, F. (1979) · Journal of Physics E: Scientific Instruments · doi:10.1088/0022-3735/12/4/001 · Cited by 499
Research works printed but not linked: 15
- ziegler, 2008, An isolated current to voltage voltage to voltage converter
- tipler, 2005, Understanding Hall effect devices
- tipler, 2005, An introduction to the Hall effect
- udd, 1991, Fiber Optic SensorsAn Introduction for Engineers and Scientists
- tipler, 1991, Physics for Scientists and Engineers
- ma, 2004, Isolated Current and Voltage Transducers
- baibich, 1997, The giant magnetoresistive head A giant leap for IBM research
- kowina, 2005, high dynamic magnetic beam current measurement by means of optimized magnet-resistance (mr) sensor engineering, Proc 7th Eur Workshop on Beam Diagnostics and Instrumentation for Particle Accelerators DIPAC 2005, 102
- beltran, 2005, AA and AB-series analog sensors datasheet
- mammano, 2005, High-side current-sense measurement
- spaziani, 1997, Using copper PCB etch for low value resistance
- spaziani, 2005, Cu-ETP copper specification
- ray, 2005, RCTrms Rogowski coil datasheet
- mammano, 1997, current sensing solutions for power supply designer, Power Design Seminar SEM 1200
- dezuari, 2003, Basic introduction to the use of magnetoresistive sensors
Cited by
Items 101–200 of 775
Wu, Y., & Zhang, P. (2020) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2020.3014995 · Cited by 30
“Traditional current measurement in power grid is realized by current transformers (CTs) or shunt resistors physically connected to transmission buses [10], which leads to low accuracy in CM current measurement due to accompanied load current disturbance.”
BackgroundFeng, Y., Shao, S., Du, J., Chen, Q., Zhang, J., & Wu, X. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3121572 · Cited by 30
Balouji, E., Salor, Ö., & McKelvey, T. (2022) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2022.3160135 · Cited by 34
“For hardware improvement, researchers have tried to adapt faster data acquisition units [22]–[24], more accurate and faster measurement sensors [25]–[27], to increase the switching frequency of power electronics switches [28]–[30] and to optimize LC filter parameters [31]–[35].”
MethodA Novel Contactless Current Sensor for HVDC Overhead Transmission Lines
Xiang, Y., Chen, K., Xu, Q., Jiang, Z., & Hong, Z. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2828807 · Cited by 30
PCB Rogowski Coils for 300 kA Current Measurement on a Multi-Split Conductor
Gu, P.-Y., Chen, Q., Li, H., Hu, C., Gong, H., & Jiao, Y. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2914730 · Cited by 29
“Due to the absence of a magnetic core, the transducer can measure high currents without saturation, thus improving the measurement accuracy and bandwidth range [5]–[8].”
BackgroundImportant Technical Considerations in Design of Battery Chargers of Electric Vehicles
Bayati, M., Abedi, M., Farahmandrad, M., Gharehpetian, G. B., & Tehrani, K. (2021) · Energies · doi:10.3390/en14185878 · Cited by 36
Current Sensor Integration Issues with Wide-Bandgap Power Converters
Sirat, A. P., & Parkhideh, B. (2023) · Sensors · doi:10.3390/s23146481 · Cited by 32
“For instance, an HE device must be compensated for temperature through closed-loop sensing and complex signal-conditioning circuitry [9,10].”
BackgroundMethodInfluentialUsing Current Surface Probe to Measure the Current of the Fast Power Semiconductors
Li, K., Videt, A., & Idir, N. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2373400 · Cited by 32
“sented by authors in [12] and [13], at present, there are hall effect current probe (HECP), Rogowski coil (RC), and current shunt (CS) that are mainly used to measure power devices switching”
BackgroundCurrent-Sensorless Power Factor Correction With Predictive Controllers
Lopez, F., Lopez-Martin, V. M., Azcondo, F. J., Corradini, L., & Pigazo, A. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2896768 · Cited by 29
“conditioning circuitry, lead to high cost [22] and complexity; resistive sensors may cause high local power losses (hot spot)”
BackgroundHuang, T., Du, M.-J., Kang, Y.-C., Peng, R.-H., Chen, K., Lin, Y.-H., Tsai, T.-Y., Lee, C.-C., Chen, L.-D., & Chen, J.-L. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2330868 · Cited by 28
Design and realization of an open‐source and modular smart meter
Sayed, S. S., Hussain, T., Gastli, A., & Benammar, M. A. (2019) · Energy Science & Engineering · doi:10.1002/ese3.361 · Cited by 35
“50,56 On the other hand, a voltage trans-former is used as a voltage measurement method.”
MethodHow to auto-configure your smart home?
Englert, F., Schmitt, T., Kößler, S., Reinhardt, A., & Steinmetz, R. (2013) · ACM International Conference on Future Energy Systems (e-Energy) · doi:10.1145/2487166.2487191 · Cited by 27
“[25] S. Ziegler, R. Woodward, H. Iu, and L. Borle.”
BackgroundXian, W., & Wang, D. F. (2017) · Applied Physics Letters · doi:10.1063/1.4979787 · Cited by 27
Zhang, W., Zhang, Z., & Wang, F. (2019) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2019.8912750 · Cited by 27
“Therefore, the ‘real’ current can be obtained by Fourier transform [17], (a) (b)”
BackgroundAn integrated fluxgate magnetometer for use in closed-loop/open-loop isolated current sensing
Snoeij, M. F., Schäffer, V., Udayashankar, S., & Ivanov, M. V. (2015) · European Solid-State Circuits Conference (ESSCIRC) · doi:10.1109/esscirc.2015.7313877 · Cited by 26
Mechanically Flexible Sensor Array for Current Measurement
Zapf, F., Weiss, R. J., Itzke, A., Gordon, R., & Weigel, R. (2020) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2020.2993119 · Cited by 26
“Those sensors typically use a ring core to guide the magnetic flux density [1]–[3].”
Lei, M., Peng, T., Zhou, F., Yu, J., Liang, S., Liu, J., & Li, L. (2022) · Energy Reports · doi:10.1016/j.egyr.2022.08.062 · Cited by 26
Chen, Y., Hsu, W.-H., Cheng, S.-H., & Cheng, Y. T. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2266089 · Cited by 26
Berba, F., Atkinson, D., & Armstrong, M. (2012) · International Symposium on Environment-Friendly Energies and Applications (EFEA) · doi:10.1109/efea.2012.6294058 · Cited by 26
Bandwidth Limits in Hall Effect-based Current Sensors
Crescentini, M., Marchesi, M., Romani, A., Tartagni, M., & Traverso, P. A. (2017) · ACTA IMEKO · doi:10.21014/acta_imeko.v6i4.478 · Cited by 26
Morales, R., Badesa, F. J., García-Aracil, N., Pérez-Vidal, C., & Sabater-Navarro, J. M. (2012) · Sensors · doi:10.3390/s120505212 · Cited by 25
“A good and recent review about current sensing techniques can be consulted in [12].”
BackgroundShahzad, D., Farooq, M., Pervaiz, S., & Afridi, K. K. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3151910 · Cited by 29
Ultrafast Protection of Discrete SiC MOSFETs With PCB Coil-Based Current Sensors
Rafiq, A., & Pramanick, S. K. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3207594 · Cited by 25
“Among several current sensing techniques [5], printed circuit”
BackgroundA Versatile ±25-A Shunt-Based Current Sensor With ±0.25% Gain Error From −40 °C to 85 °C
Tang, Z., Zamparette, R., Furuta, Y., Nezuka, T., & Makinwa, K. A. A. (2022) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2022.3204520 · Cited by 27
“BATTERY management plays an important role in applications ranging from the Internet of Things (IoT) gadgets to electric vehicles [1].”
BackgroundZhang, J., Li, P., Wen, Y., He, W., Yang, A., & Lu, C. (2014) · Smart Materials and Structures · doi:10.1088/0964-1726/23/9/095028 · Cited by 25
Compressed Sensing-Based Robust Phase Retrieval via Deep Generative Priors
Shamshad, F., & Ahmed, A. M. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3018751 · Cited by 25
“IMAGING sensors have recently drawn significant attention from the scientific community due to their numerous applications in various fields including image processing, computer vision, and optics [1], [2].”
BackgroundHigh-Current Sensing Technology for Transparent Power Grids: A Review
Sun, H., Huang, S., & Peng, L. (2024) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2024.3387432 · Cited by 24
“Compared to AMR and GMR magnetic sensors, TMRs have higher sensitivity, lower power consumption and a satisfactory linear range, and they can achieve resistance changes of more than 230% [137].”
BackgroundIntegrator Design of the Rogowski Current Sensor for Detecting Fast Switch Current of SiC Devices
Ming, L., Xin, Z., Yin, C., Chen, M., & Loh, P. C. (2019) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2019.8911874 · Cited by 24
“The same applies to an active current transformer [1, 11].”
BackgroundMethodAn Adaptive Sensorless Control Technique for a Flyback-Type Solar Tile Microinverter
Falconar, N., Beyragh, D. S., & Pahlevani, M. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2992779 · Cited by 24
“Three types of current measurement are commonly used in power electronic converters: Hall effect sensors, in-line resistors, and current transformers [13].”
BackgroundOpportunities of Electronic and Optical Sensors in Autonomous Medical Plasma Technologies
Sabrin, S., Karmokar, D. K., Karmakar, N. C., Hong, S., Habibullah, H., & Szili, E. J. (2023) · ACS Sensors · doi:10.1021/acssensors.2c02579 · Cited by 24
Lee, S., Kim, E.-M., & Lim, Y.-T. (2019) · Scientific Reports · doi:10.1038/s41598-019-44182-7 · Cited by 23
A Leakage-Inductor Parameter Compensation Method for Paralleled Current-Fed Isolated DC/DC System
Zhang, Y., Wang, Z., Li, Y., Hou, N., & Cheng, M. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2930330 · Cited by 23
“Hence, additional high-precision current sensors are required for online leakage-inductance estimation [14].”
BackgroundCrosstalk analysis and Current Measurement Correction in Circular 3D Magnetic Sensors Arrays
Guo, C., Zhang, H., Guo, H., Chen, L., Chen, W.-H., & Yu, N. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3028149 · Cited by 23
“CONTACTLESS galvanically isolated magnetic field-based current sensors transform the measurement of current into the measurement of the magnetic field by detecting the magnetic flux density generated by a conductor [1]–[4].”
BackgroundHigh-Bandwidth High-CMRR Current Measurement for a 4.8 MHz Multi-Level GaN Inverter AC Power Source
Niklaus, P. S., Bortis, D., & Kolar, J. W. (2021) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec42165.2021.9487044 · Cited by 23
Sun, K., Wang, J., Burgos, R. P., Boroyevich, D., Kang, Y., & Choi, E. (2018) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2018.8341415 · Cited by 23
“which can be used for current sensing [2].”
BackgroundFang, C., Chen, H., Torkaman, H., Anuchin, A., & Li, X. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3128487 · Cited by 22
Battery Management System for Unmanned Electric Vehicles with CAN BUS and Internet of Things
Pham, N. N., Leuchter, J., Pham, K. L., & Dong, Q. H. (2022) · Vehicles · doi:10.3390/vehicles4030037 · Cited by 26
Characterization of Inductance Gradient and Current Distribution in Electromagnetic Launchers
Ferrero, R., Marracci, M., & Tellini, B. (2010) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2010.2091186 · Cited by 22
“In many cases, current measurements are performed by means of Rogowski coils, shunts, or Hall probes [8]–[10].”
MethodMuñoz, J. V., Nofuentes, G., Fuentes, M., de la Casa, J., & Aguilera, J. (2016) · Energy · doi:10.1016/j.energy.2016.07.064 · Cited by 22
Guo, W., Xiao, G., & Wang, L. (2024) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2023.3342316 · Cited by 21
High-accuracy current measurement with low-cost shunts by means of dynamic error correction
Weßkamp, P., & Melbert, J. G. (2016) · Journal of sensors and sensor systems · doi:10.5194/jsss-5-389-2016 · Cited by 21
“Direct compensation methods are an alternative approach and are known to improve the measurement accuracy: a temperature sensor measures the temperature of the shunt material and corrects the current measurement based on the known material characteristics (Ziegler et al., 2009b).”
BackgroundLi, J., Yang, X., Xu, M., Ding, Y., Wang, L., & Wang, J. (2022) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2022.3213180 · Cited by 23
“circuit is very similar to a current transformer with one turn primary and multiple turns secondary [31], [32], [33], the inductance L1 that is directly coupled to the damping circuit corresponds to a coil of 1 turn and the value of L1 in (9) and (16) is approximately equal to the inductance factor AL .”
BackgroundA Wideband and Low-Noise CMOS-Integrated X-Hall Current Sensor Operating in Current Mode
Syeda, S. F., Crescentini, M., Marchesi, M., Traverso, P. A., & Romani, A. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3284055 · Cited by 21
“coil (RC) [3] and the current transformers (CTs) [4], [5] are competent in terms of realizable bandwidth (up to GHz) [6], but the resulting sensor is bulky, difficult to integrate, and loses the dc signal component.”
BackgroundHu, X., Duan, X., Zhang, W., Fu, Y., Li, Y., Zhao, P., Deng, X., Yu, C., & Wang, J. (2023) · Sensors · doi:10.3390/s23104749 · Cited by 21
“The conventional current transformer is extensively used in the actual operation of power systems; however, it can only measure AC signals and has the disadvantages of a large size, a complex installation structure, a high price, and a narrow bandwidth [7].”
BackgroundTong, Q., Chen, C., Zhang, Q., & Zou, X. (2015) · Sensors · doi:10.3390/s150509986 · Cited by 21
“State-of-art current sensing technologies are reviewed in [11].”
BackgroundA Flexible Inductive Coil Tag for Household Two-Wire Current Sensing Applications
Chen, Y., Yu, S.-C., Cheng, S.-H., & Cheng, Y. (2012) · IEEE Sensors Journal · doi:10.1109/jsen.2012.2183587 · Cited by 20
Compound ferroresonance overvoltage and fault current limiter for power system protection
Heidary, A., Radmanesh, H. R., Bakhshi, A., Samandarpour, S., Rouzbehi, K., & Shariati, N. (2020) · IET Energy Systems Integration · doi:10.1049/iet-esi.2019.0106 · Cited by 20
Design of Smart Socket for Monitoring of IoT-Based Intelligent Smart Energy Management System
Rao, C. K., Sahoo, S. K., Balamurugan, M., & Yanine, F. F. (2021) · Lecture notes in electrical engineering · doi:10.1007/978-981-15-8439-8_41 · Cited by 20
Li, W., Zhang, G., Zhong, H., & Geng, Y. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3105239 · Cited by 20
Liu, X., He, W., Zhao, Y., Guo, Y., & Xu, Z. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3111982 · Cited by 20
Crosstalk in Elliptical Sensor Arrays for Current Measurement
Zapf, F., Weiss, R. J., & Weigel, R. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3162625 · Cited by 20
Open-Core Optical Current Transducer:<?Pub _newline ?>Modeling and Experiment
Samimi, M. H., Akmal, A. A. S., Mohseni, H., & Jadidian, J. (2015) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2015.2490720 · Cited by 20
“O CTs have great benefits [1]–[4] and have been developed vastly in recent decades [5]–[9].”
BackgroundFeng, W., Deng, D., Yang, X., Liu, W., Wang, M., Yuan, M., Peng, J. L., & Chen, R. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2868297 · Cited by 20
“These interesting structures include Michelson interferometer [11]–[13], Fabry-Perot interferometer [14]–[16], Sagnac fiber loop interferometer [17]–[19], and Mach-Zehnder interferometer [20]–[23].”
BackgroundMocevic, S., Wang, J., Burgos, R. P., Boroyevich, D., Jaksic, M., Teimor, M., & Peaslee, B. (2019) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2019.8722167 · Cited by 19
“Even with being non-intrusive, due to its bulkiness, lower accuracy, and inability to measure DC currents, this type of measurement is not popular in inverter applications [7].”
BackgroundInfluentialA GaN-based Current Sense Amplifier for GaN HEMTs with Integrated Current Shunts
Basler, M., Mönch, S., Reiner, R. S., Waltereit, P., Quay, R., Kallfass, I., & Ambacher, O. (2020) · IEEE International Symposium on Power Semiconductor Devices and ICs/Proceedings of the International Symposium on Power Semiconductor Devices & ICs/Proceedings of the ... International Symposium on Power Semiconductor Devices & ICs/Proceedings of the ... International Symposium on Power Semiconductor Devices and ICs · doi:10.1109/ispsd46842.2020.9170047 · Cited by 19
“The thermal drift is thus about a factor 10 above coaxial and SMD shunts [17].”
BackgroundA Continuous, Impedimetric Parylene Flow Sensor
Hudson, T. Q., & Meng, E. F. (2021) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2021.3067573 · Cited by 19
“Experimental sensitivity values in μL−1 min can be converted to μV μL−1 min for comparison with existing flow sensors in the literature assuming a low-side current sensing circuit [81].”
Induced Voltage Estimation From Class EF Switching Harmonics in HF-IPT Systems
Pucci, N., Arteaga, J. M., Kwan, C. H., Yates, D. C., & Mitcheson, P. D. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3127749 · Cited by 19
Current sensor based on diamond nitrogen-vacancy color center
Shi, Z., Gao, W., Wang, Q., Guo, H., Tang, J., Li, Z., Wen, H., Ma, Z., & Liu, J. (2023) · Chinese Physics B · doi:10.1088/1674-1056/acc3fe · Cited by 20
Analytical Study of Impulse Current Measuring Shunts With Cage Configuration
Ferrero, R., Marracci, M., & Tellini, B. (2011) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2011.2175823 · Cited by 19
“Focusing on the shunt resistors, these transducers can provide very accurate current measurements over a wide frequency range and a wide range of current amplitudes [6]–[9].”
BackgroundWang, Y., Li, J., & Viehland, D. D. (2015) · Journal of Applied Physics · doi:10.1063/1.4936263 · Cited by 19
Event-Based Non-Intrusive Home Current Measurement Using Sensor Array
Wang, J., Geng, G., Chen, K., Liang, H., & Xu, W. (2017) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2698035 · Cited by 19
“Current sensing technologies featured by low-cost widerange current sensors are applied to various industrial applications [6].”
BackgroundSong, P., Cui, C., & Bai, Y. (2018) · IEEE Access · doi:10.1109/access.2018.2794458 · Cited by 19
“Although Hall-effect sensors have been used widely because of satisfactory accuracy and galvanic isolation, the shortcomings of high price and residual magnetism cannot be neglected [23], [24].”
BackgroundBlock-Wise Compressive Sensing Based Multiple Line Outage Detection for Smart Grid
Yang, F. C., Tan, J., Song, J., & Han, Z. (2018) · IEEE Access · doi:10.1109/access.2018.2869088 · Cited by 19
Liu, X., Huang, H., Cui, Y., Dai, Y., & Liu, X. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2896443 · Cited by 19
“Influence of positions of the straight primary conductor with infinite-length on mutual inductance of Rogowski coil is studied in several papers [28]–[31].”
BackgroundMichelarakis, M., Widger, P., Béroual, A., & Haddad, A. M. (2019) · Energies · doi:10.3390/en12152970 · Cited by 19
High-Fidelity Low-Cost Electronic Current Sensor for Utility Power Metering
McNeill, N., Dymond, H. C. P., & Mellor, P. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2011.2159998 · Cited by 19
“Various methods may be used to sense currents and a review is given in [4].”
MethodScreen-Returned PCB Rogowski Coil for the Switch Current Measurement of SiC Devices
Ming, L., Xin, Z., Yin, C., Loh, P. C., & Liu, Y. (2019) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2019.8721915 · Cited by 19
Chen, H., Lin, W., Shao, S., Wu, X., & Zhang, J. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3289537 · Cited by 18
“The Bx – f curve is flat when h ∈ [1, 2], even in the worst case (h = 1 mm), the degree of change of Bx is only 4%.”
BackgroundElkalashy, N. I., Kawady, T. A., Esmail, E. M., & Taalab, A. I. (2016) · IET Science Measurement & Technology · doi:10.1049/iet-smt.2015.0160 · Cited by 18
A Fully Isolated Amplifier Based on Charge-Balanced SAR Converters
Ma, S., Feng, J., Zhao, T., & Chen, B. (2017) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2017.2767678 · Cited by 18
“applications where DC current needs to be measured [3], [4].”
BackgroundStudy of Current Measurement Method Based on Circular Magnetic Field Sensing Array
Li, Z., Zhang, S., Wu, Z., Abu‐Siada, A., & Tao, Y. (2018) · Sensors · doi:10.3390/s18051439 · Cited by 18
Parkhideh, B., & Nibir, S. J. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2691262 · Cited by 18
“magnetic field induction-based transducers are among the most popular technologies and we have seen significant performance improvement over the years [8], [9].”
BackgroundGradient-Type Magnetoelectric Current Sensor with Strong Multisource Noise Suppression
Zhang, M., & Or, S. W. (2018) · Sensors · doi:10.3390/s18020588 · Cited by 18
“However, the need of a large core size and a high winding ratio gives rise to a bulky and heavy device with a limited frequency range of <5 kHz and a low CMRR of <10 dB [7,13,14].”
BackgroundA Study on Shunt Resistor-based Current Measurements for Fast Switching GaN Devices
Wickramasinghe, T., Azzopardi, S., Allard, B., Buttay, C., Joubert, C., Martín, C., Mogniotte, J. F., Morel, H., Bevilacqua, P., & Le, T.-L. (2019) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2019.8927490 · Cited by 18
“There are many current measuring concepts based on some basic physical principles [1], [2].”
BackgroundReview of Cryogenic Power Electronics for All-Electric Aircraft
Elwakeel, A., Liao, Y., Xiao, Y., Alzola, R. P., Zhang, M., & Yuan, W. (2025) · IEEE Access · doi:10.1109/access.2025.3539572 · Cited by 18
Yang, C., Pei, Y., Wang, L., Yu, L., Zhao, C., Zhu, M., & Liu, X. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2993033 · Cited by 21
“high-integration, while providing reasonable accuracy [1] comparedwith other current sensingmethod, such as Rogowski coils [2]–[5] and active current transformers [6].”
BackgroundMethodInfluentialShang, X., Wang, D. F., Itoh, T., & Maeda, R. (2021) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2021.3078386 · Cited by 17
“W ITH the rapid development of the energy industry and information industry, energy consumption has gradually increased so that current sensors with high accuracy have drawn more and more attention [1], [2].”
BackgroundIntegrated Current Sensing in GaN Power ICs
Mönch, S., Reiner, R. S., Waltereit, P., Quay, R., Ambacher, O., & Kallfass, I. (2019) · IEEE International Symposium on Power Semiconductor Devices and ICs/Proceedings of the International Symposium on Power Semiconductor Devices & ICs/Proceedings of the ... International Symposium on Power Semiconductor Devices & ICs/Proceedings of the ... International Symposium on Power Semiconductor Devices and ICs · doi:10.1109/ispsd.2019.8757678 · Cited by 17
“External current sensor approaches are well known [11], and might be also integrated or added to GaN ICs (AMR [12], TMR [13],”
BackgroundRafiq, A., Pramanick, S. K., & Maheshwari, R. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.3045956 · Cited by 17
“HBW current sensing has been a challenge, and over the years many different types of sensing methods based on several technologies have been reported [4], [5].”
BackgroundQian, S., Guo, J., Huang, H., Chen, C., Wang, H., & Li, Y. (2022) · IEEE Sensors Letters · doi:10.1109/lsens.2022.3185486 · Cited by 17
“However, they are mainly used for measuring large-magnitude currents [3].”
BackgroundInfluentialSamimi, M. H., Bahrami, S., Akmal, A. A. S., & Mohseni, H. (2014) · IEEE Sensors Journal · doi:10.1109/jsen.2014.2328873 · Cited by 17
“formers [1], and therefore this technology is of great interest nowadays [2]–[4].”
BackgroundWireless current sensing by near field induction from a spin transfer torque nano-oscillator
Ramaswamy, B., Algarín, J. M., Weinberg, I. N., Chen, Y.-J., Krivorotov, I. N., Katine, J. A., Shapiro, B., & Edo Waks, A. (2016) · Applied Physics Letters · doi:10.1063/1.4953621 · Cited by 17
Research on the simplified direct-current fluxgate sensor and its demodulation
Cao, J., Juan, Z., & Cheng, S. (2019) · Measurement Science and Technology · doi:10.1088/1361-6501/ab09bf · Cited by 17
Yu, J., Long, Z., Liang, S., Yue, C., Yin, X., & Zhou, F. (2023) · Scientific Reports · doi:10.1038/s41598-022-26971-9 · Cited by 16
Liu, J., Guan, M., Xu, Y., Zhao, S., Su, W., Zhang, C., Wang, Z., Zhang, X., Hu, Z., Jiang, Z., et al. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3322494 · Cited by 16
“For noninvasive methods, current transformers (CT) and Hall sensors have been commonly used [5], [16], [17].”
MethodA Wideband Closed-Loop Residual Current Sensor Based on Self-Oscillating Fluxgate
Ding, Z., Wang, J., Li, C., Wang, K., & Shao, H. (2023) · IEEE Access · doi:10.1109/access.2023.3335653 · Cited by 16
Huh, S., Koo, J.-I., Jeong, O., & Ahn, S. (2023) · IEEE Access · doi:10.1109/access.2023.3346037 · Cited by 16
Uncertainty Analysis of Local and Integral Methods for Current Distribution Measurements
Ferrero, R., Marracci, M., & Tellini, B. (2012) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2012.2212503 · Cited by 16
“2212503 Several methods are known and widely employed for these measurements, based for example on Hall probes, pick-up coils, or B-dot probes [10]–[12].”
MethodNon-invasive voltage measurement in a three-phase autonomous meter
Brunelli, D., Villani, C., Balsamo, D., & Luca Benini, C. (2016) · Microsystem Technologies · doi:10.1007/s00542-016-2890-7 · Cited by 16
Tunneling magnetoresistance sensors for high fidelity current waveforms monitoring
Dąbek, M., Wiśniowski, P., Kalabiński, P., Wrona, J., Moskaltsova, A., Cardoso, S., & Freitas, P. P. (2016) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2016.10.001 · Cited by 16
Nibir, S. J., Hauer, S., Biglarbegian, M., & Parkhideh, B. (2018) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2018.8341121 · Cited by 16
High Accuracy Open-Type Current Sensor with a Differential Planar Hall Resistive Sensor
Lee, S., Hong, S., Park, W., Kim, W.-H., Lee, J., Shin, K., Kim, C., & Lee, D. (2018) · Sensors · doi:10.3390/s18072231 · Cited by 16
Borole, U. P., Khan, J., Barshilia, H. C., & Chowdhury, P. (2021) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2021.113103 · Cited by 16
Frequency-Shifted Interferometry — A Versatile Fiber-Optic Sensing Technique
Ye, F., Zhang, Y., Qi, B., & Qian, L. (2014) · Sensors · doi:10.3390/s140610977 · Cited by 16
“They can be employed in electric power distribution systems where traditional electrical sensors require laborious insulation due to the high voltage involved [5].”
BackgroundWireless sensor network based flood/drought forecasting system
Khanzada, F. K., Memon, S., Jokhio, I. A., & Jokhio, S. H. (2015) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2015.7370354 · Cited by 16
“bility in a variety of fields [4]–[6].”
Roberts, D. P., Quacinella, J., & Kim, J. H. (2016) · Robotica · doi:10.1017/s0263574715000983 · Cited by 16
Calais, T., & y Alvarado, P. V. (2019) · Multifunctional Materials · doi:10.1088/2399-7532/ab4f9d · Cited by 18
Analysis and design of a self-oscillating bidirectionally saturated fluxgate current sensor
Yang, X., Wen, J., Chen, M., Gao, Z., Xi, L., & Li, Y. (2020) · Measurement · doi:10.1016/j.measurement.2020.107687 · Cited by 15
Experimental Evaluation of the Birefringence Effect on Faraday-Based Fiber-Optic Current Sensors
Madaschi, A., Brunero, M., Ferrario, M., Martelli, P., Boffi, P., & Martinelli, M. (2022) · IEEE Sensors Letters · doi:10.1109/lsens.2022.3174079 · Cited by 15
Compact Design of a Wide Bandwidth High Current Sensor Using Tilted Magnetic Field Sensors
Ziegler, P., Zhao, Y., Haarer, J., Ruthardt, J., Fischer, M., & Roth‐Stielow, J. (2023) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2023.3305979 · Cited by 15
Metadata
- Authors
- Ziegler, S., Woodward, R. C., Iu, H. H.-C., & Borle, L. J.
- Affiliations
- The University of Western Australia (AU)
- Venue
- IEEE Sensors Journal
- Published
- 2009-04
- Volume
- 9
- Issue
- 4
- Pages
- 354-376
- ISSN
- 1530-437X (ISSN-L)
- OpenAlex
- W2127394451
- Cited by
- 774
- References
- 63
- Citations by year
- 2026: 37 · 2025: 65 · 2024: 63 · 2023: 70 · 2022: 66 · 2021: 66 · 2020: 63 · 2019: 65 · 2018: 65 · 2017: 46 · 2016: 38 · 2015: 34 · 2014: 33 · 2013: 19 · 2012: 24
- FWCI
- 11.38
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Sensors Journal (publishedVersion)
- UWA Profiles and Research Repository (UWA) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Physical Sciences › Physics and Astronomy › Instrumentation › Sensor Technology and Measurement Systems
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- current sensing, current sensor, sensor principles, sensor characteristics, current measurement
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.