Current Sensing Techniques: A Review
The DOI matches its Crossref record; 62 of the 63 references it cites were found in a registry or an index.
Abstract
This paper provides a thorough review of state-of-the-art current sensing techniques. It catalogues the current sensors according to the underlying physical principle in order to point out their strengths and weaknesses.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The measurement range is limited by the accuracy of the voltage measurement [10,31].”
From Battery Management System Hardware Concepts: An Overview (2018) · cites this paper as [10]
In the citing paper
“However, solely relying on coulomb counting for precise SOC determination appears risky because current sensors are also non-ideal systems that underlie a certain drift-, offset-and temperature-error (see e.g., [10]).”
From Battery Management System Hardware Concepts: An Overview (2018) · cites this paper as [10]
In the citing paper
“Furthermore, high load current bypassing the low-side monitor-for instance caused by accidental short-circuit-cannot be detected [10].”
From Battery Management System Hardware Concepts: An Overview (2018) · cites this paper as [10]
In the citing paper
“A further drawback of this measuring method is that the output signal of a Hall effect sensor has a large temperature drift [10] that needs to be compensated in the sensor module or the signal processing chain.”
From Battery Management System Hardware Concepts: An Overview (2018) · cites this paper as [10]
Citations
Cites
Giant Magnetoresistance of (001)Fe/(001)Cr Magnetic Superlattices
Baibich, M. N., Broto, J. M., Fert, A., Van Dau, F. N., Petroff, F., Etienne, P., Creuzet, G., Friederich, A., & Chazelas, J. (1988) · Physical Review Letters · doi:10.1103/physrevlett.61.2472 · Cited by 9,415 · cited 1×
“The discoverers Gruenberg and Fert received the 2007 Physics Nobel Prize for this work [48], [49].”
BackgroundEnhanced magnetoresistance in layered magnetic structures with antiferromagnetic interlayer exchange
Binasch, G., Grünberg, P., Saurenbach, F., & Zinn, W. (1989) · Physical Review B · doi:10.1103/physrevb.39.4828 · Cited by 4,347 · cited 1×
“The discoverers Gruenberg and Fert received the 2007 Physics Nobel Prize for this work [48], [49].”
BackgroundGiant magnetic tunneling effect in Fe/Al2O3/Fe junction
Miyazaki, T., & Tezuka, N. (1995) · Journal of Magnetism and Magnetic Materials · doi:10.1016/0304-8853(95)90001-2 · Cited by 1,917 · cited 1×
“Using the TMR effect, resistance changes up to 230% at room temperature have been reported [59], [60].”
BackgroundReview of the present status of optical fiber sensors
Lee, B. (2003) · Optical Fiber Technology · doi:10.1016/s1068-5200(02)00527-8 · Cited by 1,736 · cited 4×
“35, that allows it to generate a linear output from the detected signal by building the ratio of the first and second harmonic amplitude level [62], [70].”
BackgroundMethodInfluentialMagnetic sensors and their applications
Lenz, J., & Edelstein, S. (2006) · IEEE Sensors Journal · doi:10.1109/jsen.2006.874493 · Cited by 1,312 · cited 5×
“It has to be noted that this is just one example of a structure that exhibits the GMR effect [33], [50].”
BackgroundInfluentialInductance Calculations Working Formulas and Tables
Snyder, J. N., & Grover, F. C. (1964) · Mathematics of Computation · doi:10.2307/2003443 · Cited by 1,309 · cited 1×
“In reality, the parasitic inductance is determined by the mutual inductance between loop built by the sense wires and the loop built by the main current [1].”
Background230% room-temperature magnetoresistance in CoFeB∕MgO∕CoFeB magnetic tunnel junctions
Djayaprawira, D. D., Tsunekawa, K., Nagai, M., Maehara, H., Yamagata, S., Watanabe, N., Yuasa, S., Suzuki, Y., & Ando, K. (2005) · Applied Physics Letters · doi:10.1063/1.1871344 · Cited by 967 · cited 1×
“Using the TMR effect, resistance changes up to 230% at room temperature have been reported [59], [60].”
BackgroundFiber Optic Sensors: An Introduction for Engineers and Scientists
(2011) · Wiley eBooks · doi:10.1002/9781118014103 · Cited by 783 · cited 1×
“Linear birefringent material behaves vice versa [61].”
Giant magnetic field dependent impedance of amorphous FeCoSiB wire
Beach, R. S., & Berkowitz, A. E. (1994) · Applied Physics Letters · doi:10.1063/1.111170 · Cited by 650
Primdahl, F. (1979) · Journal of Physics E: Scientific Instruments · doi:10.1088/0022-3735/12/4/001 · Cited by 499
Research works printed but not linked: 15
- ziegler, 2008, An isolated current to voltage voltage to voltage converter
- tipler, 2005, Understanding Hall effect devices
- tipler, 2005, An introduction to the Hall effect
- udd, 1991, Fiber Optic SensorsAn Introduction for Engineers and Scientists
- tipler, 1991, Physics for Scientists and Engineers
- ma, 2004, Isolated Current and Voltage Transducers
- baibich, 1997, The giant magnetoresistive head A giant leap for IBM research
- kowina, 2005, high dynamic magnetic beam current measurement by means of optimized magnet-resistance (mr) sensor engineering, Proc 7th Eur Workshop on Beam Diagnostics and Instrumentation for Particle Accelerators DIPAC 2005, 102
- beltran, 2005, AA and AB-series analog sensors datasheet
- mammano, 2005, High-side current-sense measurement
- spaziani, 1997, Using copper PCB etch for low value resistance
- spaziani, 2005, Cu-ETP copper specification
- ray, 2005, RCTrms Rogowski coil datasheet
- mammano, 1997, current sensing solutions for power supply designer, Power Design Seminar SEM 1200
- dezuari, 2003, Basic introduction to the use of magnetoresistive sensors
Cited by
Items 201–300 of 775
Nabias, J., Asfour, A., & Yonnet, J.-P. (2017) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2017.2703981 · Cited by 15
“The flexible current transformers are also not suited for measuring dc current in their standard configuration [4].”
BackgroundPractical Use of the GMI Effect to Make a Current Sensor
Asfour, A., Nabias, J., Traoré, P. S., & Yonnet, J.-P. (2018) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2018.2872622 · Cited by 15
“They can only measure ac or transit currents in their standard configurations [14].”
BackgroundRothan, F., Lhermet, H., Zongo, B., Condemine, C., Sibuet, H., Mas, P., & Debarnot, M. (2011) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2011.5746242 · Cited by 15
The Analysis of Magnetic Flux Density Inside Rogowski Coil Based on Full Current Theory
Han, S., Han, X., & Sun, W. (2020) · IEEE Sensors Letters · doi:10.1109/lsens.2020.2987707 · Cited by 14
“The theory of the Rogowski coil is mainly based on Ampere’s law and Faraday’s law at present [2], [3].”
MethodBusbar Current Measurement With Elliptical Sensor Arrays Without Conductor Specific Calibration
Weiss, R. J., Zapf, F., Skelly, A., & Weigel, R. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3077677 · Cited by 14
“3077677 and mechanical flexibility [2], [3].”
Recommendations and Typical Errors in Design of Power Converter PCBs With Shunt Sensors
Dianov, A. (2022) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2022.3179705 · Cited by 14
Chen, Y. C., Hsu, W. H., Cheng, S. H., & Cheng, Y. (2012) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2012.6170264 · Cited by 14
“Current sensors like Rogowski coil, current transformer, Hall effect-based, fluxgate, and have been widely utilized for industrial appliance monitoring applications [2-5].”
Leakage current sensing techniques
Shede, P., & Mane, S. (2017) · International Conference on Sensing, Signal Processing and Security (ICSSS) · doi:10.1109/ssps.2017.8071588 · Cited by 14
Dewangga, B. R., Herdjunanto, S., & Cahyadi, A. I. (2018) · doi:10.1109/icstc.2018.8528694 · Cited by 14
“On the other hand, hall-effect-based current sensor which is isolated from a battery pack is expensive [2].”
BackgroundFlexible-substrate Fluxgate Current Sensor Based on MEMS Technology
Yang, S., & Rong, F. (2020) · Sensors and Materials · doi:10.18494/sam.2020.2737 · Cited by 14
A Nonintrusive Digital Current Sensing Method for DC–DC Converters With Wide Load Range
Biswas, K., & Ray, O. (2023) · IEEE Sensors Letters · doi:10.1109/lsens.2023.3276777 · Cited by 15
“, sense resistor, hall-effect sensors) that need physical connection either in series or around the current path [3], [4].”
BackgroundA Redundancy Mechanism Design for Hall-Based Electronic Current Transformers
Chen, K.-L., Wan, R.-S., Guo, Y., Chen, N., & Lee, W. (2017) · Energies · doi:10.3390/en10030312 · Cited by 14
Wang, M., Wang, X., Fan, Z., Chen, F., Zhang, S., & Chen, P. (2018) · Journal of Visual Communication and Image Representation · doi:10.1016/j.jvcir.2018.12.017 · Cited by 14
Design of a Low-Cost Residual Current Sensor for LVDC Power Distribution Application
de Oliveira, T. R. (2018) · IEEE International Conference on Industry Applications · doi:10.1109/induscon.2018.8627238 · Cited by 14
“Isolated DC current sensors are mainly based on Halleffect or fluxgate technology, with fluxgate transducers presenting higher linearity, accuracy and precision, but slightly higher power consumption and size [18], [19].”
BackgroundQiu, Y., Chen, X., Zhong, C., & Qi, C. (2014) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2014.2310632 · Cited by 14
“In order for the steady-state condition to be realized at the end of transient, the algorithm determines and resets the output of the linear PI compensator according to the actual steady-state duty ratio shown in (21).”
MethodLossless Inductor Current Sensing Method With Improved Frequency Response
Ziegler, S., Woodward, R. C., Iu, H. H., & Borle, L. J. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2013954 · Cited by 14
“determine the measurement bandwidth by using the 3-dB corner frequency that is given by [8]”
MethodSelf-citationIn-Situ Ultrafast Sensing Techniques for Prognostics and Protection of SiC Devices
Sirat, A. P., Roy, C., Evans, D., Gafford, J. R., & Parkhideh, B. (2022) · IEEE Workshop on Wide Bandgap Power Devices and Applications · doi:10.1109/wipda56483.2022.9955254 · Cited by 13
“In-situ Rogowski-based current sensor and their combination are among the best techniques to have a bandwidth over 10 MHz [9-12].”
BackgroundZhao, J., Yan, M., Xu, S., & Sun, X. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3218698 · Cited by 13
“Optical fiber sensor uses fiber as insulation-sensitive material and low-loss remote signal transmission medium [20], [21], where the fiber optic current sensors (FOCSs) are becoming more common in ac/dc current measurements in power systems [22], [23], [24].”
BackgroundTeler, K., & Orłowska-Kowalska, T. (2023) · Power Electronics and Drives · doi:10.2478/pead-2023-0003 · Cited by 13
Wu, Y., Wei, Z., Yang, Y., & Zhang, P. (2023) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2023.3285920 · Cited by 13
Qu, T., Dong, T., Qin, W., Pan, Y., Sheng, Y., Hong, Z., Zeng, X., & Xu, J. (2024) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2024.3468955 · Cited by 13
“M AGNETOMETER-BASED contactless current sensors, featuring great galvanic isolation, maintainability, and power efficiency, facilitate safe and reliable monitoring of electrical currents [1], [2].”
Efficiency and cost trade-offs for designing module integrated converter photovoltaic systems
Kim, K. A., Lertburapa, S., Xu, C., & Krein, P. T. (2012) · IEEE Power and Energy Conference at Illinois (PECI) · doi:10.1109/peci.2012.6184585 · Cited by 13
“high side current sensing in boost converters [11].”
BackgroundGakopoulos, S., Nica, I. G., Bekteshi, S., Aerts, J., Monbaliu, E., & Hallez, H. (2019) · Sensors · doi:10.3390/s19245404 · Cited by 15
“The method is based on measuring voltage drop across the current shunt resistor that ranges between tens and hundreds mΩ with a tolerance no higher than 1% [31,32].”
MethodNovel Principle for Flux Sensing in the Application of a DC + AC Current Sensor
Schrittwieser, L., Mauerer, M., Bortis, D., Ortiz, G., & Kolar, J. W. (2015) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2015.2434875 · Cited by 13
“If no galvanic isolation between the input current and the sensing circuit is required, the current can be directly measured with a shunt resistor [1].”
BackgroundUltra-Low-Power Current Sensor Utilizing Magnetoelectric Nanowires
Bauer, M. J., Thomas, A., Isenberg, B., Varela, J., Faria, A., Arnold, D. P., & Andrew, J. S. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2968224 · Cited by 13
“In a magnetic-field-based current sensor, either a magnetic core can be incorporated or a core-less design can be used [1].”
BackgroundPCB-Based Current Sensor Design for Sensing Switch Current of a Nonmodular GaN Power Semiconductor
Kim, U.-J., Song, M.-S., & Kim, R.-Y. (2020) · Energies · doi:10.3390/en13195161 · Cited by 13
“The CT is a widely researched and commercialized sensor method; however, owing to the characteristics of the ferromagnetic core constituting the coil, it has a nonlinear characteristic that is saturated in a high-frequency and overcurrent-type environment and demonstrates the disadvantages of large core loss and limit…”
BackgroundA Low-Noise Instrumentation Amplifier With Built-in Anti-Aliasing for Hall Sensors
Riem, R., Raman, J., Borgmans, J., & Rombouts, P. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3090251 · Cited by 15
Luo, C., Zhang, Y., Shao, W., Wang, L., Fang, W., Chen, Y., & Fernández, R. (2024) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2024.3389021 · Cited by 12
“…including a non-contact scattering parameter measurement system for planar two-port devices [40], a noncontact scattering parameter measurement device for printed coupling structures [41], a tunable directional coupler [42], and the characterization of embedded devices using noncontact probes [9].”
BackgroundChen, S.-H., Chou, P.-C., & Cheng, S. (2015) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2015.12.110 · Cited by 12
Lee, J.-A., Ann, S., Sim, D. H., & Lee, B. (2022) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec43599.2022.9773781 · Cited by 12
“Conversely, to increase Cu, the f0dB should be increased while keeping A0 constant, because the DC gain of RCS C0 is generally designed 0 [dB] or lower to prevent from saturation of the integrator due to the input offset voltage [16], [17].”
BackgroundGao, J., Wang, L., Wu, S., Xie, C., Song, B., & Fang, Y. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3228826 · Cited by 12
“For discharge current data, common sensors in HV tests are using coils [30], [31] and shunts [32].”
BackgroundPCB Rogowski Coils for Capacitors Current Measurement in System Stability Enhancement
Yue, X., Zhu, G., Wang, J. V., Deng, X., & Wang, Q. (2023) · Electronics · doi:10.3390/electronics12051099 · Cited by 12
Current Distribution Measurements in Rail Launcher Multibrush Armatures During Launch
Ferrero, R., Marracci, M., & Tellini, B. (2013) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2012.2220038 · Cited by 12
“In the last years several methods have been proposed to measure the current distribution among the brushes, based on Rogowski coils, B-dot sensors and measurements of the voltage at the launcher muzzle or along the rails [4]–[10].”
MethodLow‐power design for DC current transformer using class‐D compensating amplifier
Veinović, S., Ponjavic, M. M., Milić, S., & Djurić, R. (2017) · IET Circuits Devices & Systems · doi:10.1049/iet-cds.2017.0324 · Cited by 12
Yu, J., Zhang, C., Li, C., Wang, X., Li, Y., & Feng, X. (2013) · Optical Engineering · doi:10.1117/1.oe.52.11.117101 · Cited by 12
Class H Power Amplifier for Power Saving in Fluxgate Current Transducers
Quesada, G. V., Lumbreras, M. R., Delgado, R. P., & Conesa-Roca, A. (2016) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2516399 · Cited by 12
“Furthermore, in references [7]–[9] some reviews devoted to the description of electric current sensors technologies can be found.”
BackgroundDesign of Fluxgate Current Sensor Based on Magnetization Residence Times and Neural Networks
Li, J., Ren, W., Luo, Y., Zhang, X., Liu, X., & Zhang, X. (2024) · Sensors · doi:10.3390/s24123752 · Cited by 11
Huangfu, Y., Faifer, M., Ottoboni, R., & Toscani, S. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3432142 · Cited by 11
“Specifically, the RC type LPCT is an air-core current transducer working on the fundamental principles of Ampere’s and Faraday’s law [22], [23], [24].”
MethodNoninvasive current sensor for household appliances and compensation for installation variation
Cheng, S. H., & Lin, S. (2013) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2013.01.022 · Cited by 11
“[6] S.”
Development of a Fiber-Optic Current Sensor With Range-Changing Facility Using Shunt Configuration
Ghosh, A., Gupta, P. B. D., & Mandal, A. K. (2012) · IEEE Sensors Journal · doi:10.1109/jsen.2012.2235752 · Cited by 11
Wide bandwidth current probe for power electronics using tunneling magnetoresistance sensors
Tröster, N., Dominkovic, B., Wölfle, J., Fischer, M., & Roth‐Stielow, J. (2017) · IEEE International Conference on Power Electronics and Drive Systems (PEDS) · doi:10.1109/peds.2017.8289128 · Cited by 11
“There exist several concepts [1] [2] to build a contact-free current probe, e.”
BackgroundNovel High-Frequency Electrical Characterization Technique for Magnetic Passive Devices
Fernández, C., Pavlović, Z. T., Kulkarni, S., McCloskey, P., & O’Mathúna, C. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2798919 · Cited by 11
“2) Current Probes: The Pearson Current Monitor model 2877 is selected for the current measurements due to its bandwidth (200 MHz) and low delay [16], [17], in contrast to the use of resistors, as is often reported in the literature [12], [13], [18], [19].”
ResultWu, X. D., Huang, H., Peng, L., Huang, Y., & Wang, Y. (2022) · IEEE Transactions on Plasma Science · doi:10.1109/tps.2022.3173286 · Cited by 11
AC power meter design for home electrical appliances
Tamkittikhun, N., Tantidham, T., & Intakot, P. (2015) · International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology (ECTI-CON) · doi:10.1109/ecticon.2015.7207005 · Cited by 11
“There are many types of voltage and current sensors based on different working principles [7], [8], [9].”
BackgroundRogowski current sensor design and analysis based on printed circuit boards (PCB)
Wang, R., Prabhakaran, S., Burdick, W. E., & Nicholas, R. (2014) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2014.6953836 · Cited by 11
“Rogowski coils are popular for sensing alternating currents ([1-3]).”
BackgroundImplementation and performance of a current sensor for a laminated bus bar
Kuwabara, Y., Wãda, K., Guichon, J., Schanen, J., & Roudet, J. (2016) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2016.7855187 · Cited by 14
“Power converter circuits for motor drives and utility applications[3] have to be connected to voltage and current sensors[4] in order to control the output voltage and the current of the circuit.”
BackgroundGarrigues, S., Esteve-Turrillas, F. A., & de la Guárdia, M. (2019) · Current Opinion in Green and Sustainable Chemistry · doi:10.1016/j.cogsc.2019.04.002 · Cited by 11
Electromagnetic Compatibility Analysis of an Induction Motor Drive With Integrated Power Converter
Chen, T., Caicedo-Narvaez, C., Wang, H., Moallem, M., Fahimi, B., & Kiani, M. (2019) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2019.2949518 · Cited by 11
“Both of these sensors use the open-loop measurement [9], that is, to measure the current amplitude from its resulting magnetic field.”
BackgroundGarcı́a, R., Blanco, E., & Domínguez, M. (2016) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2016.08.010 · Cited by 11
Open-source wideband (DC to MHz range) isolated current sensor
Ulrich, B. (2019) · HardwareX · doi:10.1016/j.ohx.2019.e00057 · Cited by 11
Li, K. (2014) · theses.fr (ABES) · doi:10.70675/7a0e101fza89dz4d38z8f5fzb54e70bd63c7 · Cited by 17
“Among all the current measurement techniques presented by authors in [110, 111], at present, there are Hall Effect Current Probe (HECP), Rogowski Coil (RC) and Current Shunt (CS) used to measure power devices switching current in power converters.”
A non-contact broad bandwidth current sensor
Zhang, R., Zhang, Q., Geng, J., & Liu, F. (2022) · Measurement Science and Technology · doi:10.1088/1361-6501/ac7a92 · Cited by 10
“…applied in the above-mentioned fields mainly include current transformers and Rogowski ∗ Author to whom any correspondence should be addressed. coils; current transformers are widely used in power systems, while Rogowski coils are widely used in the field of pulsed high-current measurements [2–5].”
Xu, P., An, N., Yang, Z., Wang, Y., Zhou, Q., Deng, S., & Sun, X. (2024) · Measurement · doi:10.1016/j.measurement.2024.114741 · Cited by 10
Review on Short-Circuit Protection Methods for SiC MOSFETs
Lyu, G., Ali, H., Tan, H., Peng, L., & Ding, X. (2024) · Energies · doi:10.3390/en17174523 · Cited by 14
“As shown in Figure 14, by monitoring the V GS and comparing the total gate charge to a reference threshold ( Q ref ), the system can accurately detect short-circuit events.”
BackgroundKe, X., Pang, L., Dong, X. Y., & Li, Z. (2019) · IEEE Access · doi:10.1109/access.2019.2951577 · Cited by 10
“3) due to the theoretical errors [25], [26].”
BackgroundNonintrusive Installation of the TMR Busbar DC Current Sensor
Xu, X. P., Liu, T., Zhu, M., & Wang, J. G. (2021) · Journal of Sensors · doi:10.1155/2021/8827131 · Cited by 10
“Due to its noncontact isolation measurement, high precision, and low cost [1, 2], current sensors are widely used in power electronic systems, such as photovoltaics, wind power, and electric vehicles, and the use of current sensors has increased year by year.”
BackgroundA Switched-Capacitor Power Side-Channel Attack Detection Circuit in 65-nm CMOS
Kaushik, N., & Hu, J. R. (2021) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas51556.2021.9401474 · Cited by 10
An Optimal Current Observer for Predictive Current Controlled Buck DC-DC Converters
Min, R., Chen, C., Zhang, X., Zou, X., Tong, Q., & Zhang, Q. (2014) · Sensors · doi:10.3390/s140508851 · Cited by 10
High-Frequency Voltage and Current Sense Circuits for Inductive Power Transfer Systems
Zhu, G., & Gao, D. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2989922 · Cited by 10
“In current sensors, two principles are commonly used: Faraday’s law of induction and magnetic field sensing [29].”
BackgroundMethodKim, D.-K., Jang, D.-H., & Yoon, D.-Y. (2020) · Journal of Electrical Engineering and Technology · doi:10.1007/s42835-020-00583-7 · Cited by 10
A Galvanic Isolated Amplifier Based on CMOS Integrated Hall-Effect Sensors
Mirfakhraei, S. S., Audet, Y., Hassan, A., & Sawan, M. (2021) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2021.3052476 · Cited by 10
“the output of open-loop magnetic sensor and a CT to achieve wide bandwidth current measurement [13].”
Current Sensorless MPPT Control for PV Systems Based on Robust Observer
Cortés-Vega, D., Alazki, H., & Rullan-Lara, J. L. (2022) · Applied Sciences · doi:10.3390/app12094360 · Cited by 10
“Hence, a heat power dissipation exists across this type of sensor because of Joule’s effect which affects the measurement, so it requires low tolerance, high precision and low temperature drift resistance [6,7].”
BackgroundNielsen, M. R., Kirkeby, M., Zhao, H., Dalal, D. N., Bech, M. M., & Munk‐Nielsen, S. (2022) · IEEE Workshop on Wide Bandgap Power Devices and Applications · doi:10.1109/wipda56483.2022.9955291 · Cited by 10
“fore, each application has specific requirements for the current sensor regarding size, cost, accuracy, range, bandwidth, and insulation [15].”
BackgroundResearch on the Factors Influencing the Measurement Errors of the Discrete Rogowski Coil
Xu, M., Yan, J., Geng, Y., Zhang, K., & Sun, C. (2018) · Sensors · doi:10.3390/s18030847 · Cited by 10
“The Rogowski coil (RC) has been very well known in laboratories for decades [1,2], especially for the measurement of high-frequency current pulses.”
BackgroundDecker, S., Liske, A., Schweiker, D., Kolb, J., & Braun, M. (2018) · International Power Electronics Conference (IPEC) · doi:10.23919/ipec.2018.8507431 · Cited by 10
Seyedzadeh, S., Christodoulou, V., Turner, A., & Lotfian, S. (2025) · Journal of Manufacturing and Materials Processing · doi:10.3390/jmmp9070210 · Cited by 27
Nibir, S. J., Biglarbegian, M., & Parkhideh, B. (2016) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2016.7808725 · Cited by 9
“Researchers have also demonstrated the potential to combine hall-effect and Rogowski coil-based detection methods to achieve a bandwidth of tens of MHz [7].”
BackgroundSotirov, S., & Tokmakov, D. (2019) · National Conference with International Participation (ELECTRONICA) · doi:10.1109/electronica.2019.8825613 · Cited by 9
“Integrated magnetic sensors have a broad range of applications, such as position sensing, compasses, smart sensor parking systems and isolated current sensing [3].”
BackgroundHigh-Frequency Non-Invasive Magnetic Field-Based Condition Monitoring of SiC Power MOSFET Modules
Naghibi, J., Mehran, K., & Foster, M. P. (2021) · Energies · doi:10.3390/en14206720 · Cited by 11
Rogowski Coil Sensors for Measuring Lightning Strike Currents on Mechanical Aircraft Joints
Solé-Lloveras, J., Azpúrua, M. A., Quílez, M., & Silva, F. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3232160 · Cited by 9
“After reviewing the state of the art [5], [6], [7], [8], it was decided that the Rogowski coil type of sensors were suitable to measure the current that circulates through the mechanical joints that attach fuselage panels.”
BackgroundA Current Monitoring and Over-Current Detection Circuit for Safe Electrical Stimulation
Huang, Y.-K., Rusu, A., & Rodriguez, S. (2023) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2023.3252804 · Cited by 9
“The current-shunt monitor architecture [10] shown in Fig.”
MethodA low power 16-channel fully integrated GMR-based current sensor
Rothan, F., Condemine, C., Delaet, B., Redon, O., & Giraud, A. (2012) · European Solid-State Circuits Conference (ESSCIRC) · doi:10.1109/esscirc.2012.6341304 · Cited by 9
“However, they present a moderate sensitivity, so their use is limited to high current applications [1].”
BackgroundGMR Based Sensors for IC Current Monitoring
Reig, C., & Cubells‐Beltrán, M. (2013) · Smart sensors, measurement and instrumentation · doi:10.1007/978-3-642-37172-1_5 · Cited by 9
Magnetic Fiber Integrator and its Application in Precision Noninvasive DC Current Sensor
Grno, L. (2017) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2017.2674339 · Cited by 9
“Comprehensive reviews of the state-of-the-art principles and realizations can be found in [1] and [2].”
BackgroundAnalysis of Ultra-Thin and Flexible Current Transformer Based on JA Hysteresis Model
Narampanawe, N. B., See, K. Y., Zhang, J., Chua, E. K., & Goh, W. P. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2705197 · Cited by 9
“A thorough review on various current sensing methods is presented in [3].”
BackgroundMin, R., Tong, Q., Zhang, Q., Chen, C., Zou, X., & Lv, D. (2017) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2017.09.025 · Cited by 9
Development of GaN Transducer and On-Chip Concentrator for Galvanic Current Sensing
Faramehr, S., Poluri, N., Igić, P., Janković, N., & Souza, M. M. D. (2019) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2019.2936687 · Cited by 9
“Shunt resistorbased sensing comes with power loss, frequency-dependent parasitics, and no galvanic isolation [2].”
BackgroundDanesh, S., Holland, W., Spalding, G. R., Guidry, M., & Hurwitz, J. (2019) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2019.2943109 · Cited by 9
“The accuracy of the measurement over the lifetime of the meter is dependent on the stability of the measurement frontend and sensors, which can drift with time and/or environmental influence [4].”
BackgroundHigh Temperature Graphene Sensors for Harsh Environment Current Sensing
Peters, A., Turvey, S., & Horsfall, A. B. (2019) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/sensors43011.2019.8956693 · Cited by 9
“InSb is one of the most commonly used semiconductors for room temperature Hall sensing due to its high sensitivity [10] however it suffers from large thermal drift due bandgap narrowing with increasing temperature causing a large shift in”
BackgroundAlGaN/GaN 2-D Electron Gas for Highly Sensitive and High-Temperature Current Sensing
Nguyen, H.-Q., Dinh, T., Moghadam, H. A., Nguyen, T., Nguyen, T., Han, J., Dimitrijev, S., Zhu, Y., Nguyen, N., & Dao, D. V. (2021) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2021.3054360 · Cited by 9
“Other current sensing techniques utilize current transformers and Rogowski coils that are only applicable for alternating current (ac) sensing [4], [5].”
MethodCompact Design of a Wide Bandwidth High Current Sensor Using Tilted Magnetic Field Sensors
Ziegler, P., Zhao, Y., Haarer, J., Ruthardt, J., Fischer, M., & Roth‐Stielow, J. (2021) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce47101.2021.9595039 · Cited by 9
“Due to the galvanically isolated measurement technique and the simple and cheap realization, the choice often falls on magnetic field-based current sensors [1].”
BackgroundMethodA Fully Integrated Low-Power Hall-Based Isolation Amplifier With IMR Greater Than 120 dB
Mirfakhraei, S. S., Audet, Y., Hassan, A., & Sawan, M. (2022) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2021.3138301 · Cited by 9
Hybrid Microfluxgate and Current Transformer Sensor
Lu, C., Lin, Y.-C., Tian, Y.-Z., & Jeng, J.-T. (2022) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2022.3157052 · Cited by 9
Planar Hall Resistance Sensor for Monitoring Current
Kim, K., Torati, S. R., Reddy, V., & Yoon, S.-S. (2014) · Journal of Magnetics · doi:10.4283/jmag.2014.19.2.151 · Cited by 9
HW issues of current sensing by DC-link shunt resistor
Pácha, M., Varecha, P., & Sumega, M. (2018) · ELEKTRO · doi:10.1109/elektro.2018.8398266 · Cited by 9
Long, B., Huang, L., Dai, Y., Lu, Y., & Chong, K. T. (2018) · Energies · doi:10.3390/en11082047 · Cited by 9
“To solve the zero-drift problems, an auto-calibrating inverter has been proposed by Armstrong [23].”
MethodFiber optic current sensor temperature compensation through RBF neural network
Liu, C., Wang, D., Li, C., Su, K., Li, D., Yu, D., Wang, L., Si, L., & Jin, J. (2020) · Applied Optics and Photonics China (AOPC) · doi:10.1117/12.2579466 · Cited by 9
“Until, when the light reaches the mirror in the sensing ring, it will travel back the way it came 16 .”
BackgroundCurrent sensorless control of a boost-type switch mode rectifier using an adaptive inductor model
Engel, A., Nandi, S., & Panfilov, I. (2015) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2015.7310484 · Cited by 9
“But isolation, high cost, size, incapability of measuring direct currents, low accuracy, unsuitability for small currents [2],[3] are their limitations.”
BackgroundKawahara, S., Furuta, Y., Wada, S., Taniguchi, S., & Nezuka, T. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3393442 · Cited by 9
2-D Magnetoresistive Point Field Detector-based Current Sensing for High-Density Power Modules
Alvi, M. H., Sheng, M., & Lorenz, R. D. (2019) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2019.8721938 · Cited by 8
“Rogowski coils which are air core transformers, have been integrated into power modules [5] but the intricate coil design and the use of an integrator makes them costly, complex and prone to errors [2][4].”
BackgroundA New Approach for Solving the False Balance of a Closed-Loop Fluxgate Current Transducer
Zhang, S., Wang, Y., Xie, J., Ding, T., & Han, X. (2021) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2021.3063983 · Cited by 8
Ring-Core Fluxgate Sensor for High Operation Temperatures up to 220 °C
Yuan, K., Du, A., Zhao, L., Sun, S., Feng, X., Zhang, C., Zhang, Y., & Qin, H. (2022) · Micromachines · doi:10.3390/mi13122158 · Cited by 8
Online Calibration Study of Non-Contact Current Sensors for Three-Phase Four-Wire Power Cables
Yan, P., Zhang, W., Yang, L., Zhang, W., Yu, H., Huang, R., Zhu, J., & Liu, X. (2023) · Sensors · doi:10.3390/s23052391 · Cited by 8
“Measuring the power conductor current accurately and easily is always a challenging task in the electric power industry [10,11].”
BackgroundYan, B., Zhu, W., Sun, Y. P., Lu, Z., Zhuang, X., & Fang, G. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3363619 · Cited by 8
“…significantly used in space magnetic field measurement, magnetic anomaly detection, underwater target detection and tracking, nonde-structive testing, positioning/navigation/timing, nondestructive testing, positioning and navigation, and many other fields [7], [11], [12], [13], [14], [15], [16].”
BackgroundAnalysis and Compensation of Current Measurement Errors in Machine Drive Systems—A Review
Song, P., Wang, T., Wu, L., Li, H. M., Meng, X. P., & Cheng, L. (2025) · Energies · doi:10.3390/en18061367 · Cited by 8
Low-Noise Isolated Digital Shunt for Precision Class-D Power Amplifiers
Mauerer, M., Tüysüz, A., & Kolar, J. W. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2744806 · Cited by 8
“The shunt resistor RS offers low noise and a high linearity compared to other integrated, isolated current sensors [6], [7].”
BackgroundAn Isolated Capacitor-Compensated Current Sensing Method for High-Frequency Resonant Converters
Wang, K., Li, H., Yu, Z., Wang, L., Yang, X., & Qiu, A. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2886226 · Cited by 8
Current Observer Based Predictive Decoupled Power Control Grid-Interactive Inverter
Zhang, Z., Adepoju, W. O., Hosseinzadehtaher, M., & Shadmand, M. B. (2020) · IEEE Texas Power and Energy Conference (TPEC) · doi:10.1109/tpec48276.2020.9042581 · Cited by 8
“Sensing techniques include resistivecurrent sensing, inductor resistance-based sensing, current transformer-based sensing, and hall-effect sensors among other techniques [3], all of which are subject to either high power dissipation or noisy measurement [4].”
BackgroundSensing of temperature through magnetooptical domain wall susceptibility
Klingbeil, F., Stölting, S. D., & McCord, J. (2021) · Applied Physics Letters · doi:10.1063/5.0037128 · Cited by 8
Phase current sensing technique for two-phase three-leg inverters using three shunt resistors
Kim, D.-K. (2022) · Journal of Power Electronics · doi:10.1007/s43236-021-00363-0 · Cited by 8
“In [1] and [2], the performance, size, and cost of various current sensing techniques such as Hall-effect sensors, current transformers, magneto resistance sensors, Rogowski coils, and shunt resistors were investigated.”
Background
Metadata
- Authors
- Ziegler, S., Woodward, R. C., Iu, H. H.-C., & Borle, L. J.
- Affiliations
- The University of Western Australia (AU)
- Venue
- IEEE Sensors Journal
- Published
- 2009-04
- Volume
- 9
- Issue
- 4
- Pages
- 354-376
- ISSN
- 1530-437X (ISSN-L)
- OpenAlex
- W2127394451
- Cited by
- 774
- References
- 63
- Citations by year
- 2026: 37 · 2025: 65 · 2024: 63 · 2023: 70 · 2022: 66 · 2021: 66 · 2020: 63 · 2019: 65 · 2018: 65 · 2017: 46 · 2016: 38 · 2015: 34 · 2014: 33 · 2013: 19 · 2012: 24
- FWCI
- 11.38
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Sensors Journal (publishedVersion)
- UWA Profiles and Research Repository (UWA) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Physical Sciences › Physics and Astronomy › Instrumentation › Sensor Technology and Measurement Systems
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- current sensing, current sensor, sensor principles, sensor characteristics, current measurement
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.