Current Sensing Techniques: A Review
The DOI matches its Crossref record; 62 of the 63 references it cites were found in a registry or an index.
Abstract
This paper provides a thorough review of state-of-the-art current sensing techniques. It catalogues the current sensors according to the underlying physical principle in order to point out their strengths and weaknesses.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The measurement range is limited by the accuracy of the voltage measurement [10,31].”
From Battery Management System Hardware Concepts: An Overview (2018) · cites this paper as [10]
In the citing paper
“However, solely relying on coulomb counting for precise SOC determination appears risky because current sensors are also non-ideal systems that underlie a certain drift-, offset-and temperature-error (see e.g., [10]).”
From Battery Management System Hardware Concepts: An Overview (2018) · cites this paper as [10]
In the citing paper
“Furthermore, high load current bypassing the low-side monitor-for instance caused by accidental short-circuit-cannot be detected [10].”
From Battery Management System Hardware Concepts: An Overview (2018) · cites this paper as [10]
In the citing paper
“A further drawback of this measuring method is that the output signal of a Hall effect sensor has a large temperature drift [10] that needs to be compensated in the sensor module or the signal processing chain.”
From Battery Management System Hardware Concepts: An Overview (2018) · cites this paper as [10]
Citations
Cites
Giant Magnetoresistance of (001)Fe/(001)Cr Magnetic Superlattices
Baibich, M. N., Broto, J. M., Fert, A., Van Dau, F. N., Petroff, F., Etienne, P., Creuzet, G., Friederich, A., & Chazelas, J. (1988) · Physical Review Letters · doi:10.1103/physrevlett.61.2472 · Cited by 9,415 · cited 1×
“The discoverers Gruenberg and Fert received the 2007 Physics Nobel Prize for this work [48], [49].”
BackgroundEnhanced magnetoresistance in layered magnetic structures with antiferromagnetic interlayer exchange
Binasch, G., Grünberg, P., Saurenbach, F., & Zinn, W. (1989) · Physical Review B · doi:10.1103/physrevb.39.4828 · Cited by 4,347 · cited 1×
“The discoverers Gruenberg and Fert received the 2007 Physics Nobel Prize for this work [48], [49].”
BackgroundGiant magnetic tunneling effect in Fe/Al2O3/Fe junction
Miyazaki, T., & Tezuka, N. (1995) · Journal of Magnetism and Magnetic Materials · doi:10.1016/0304-8853(95)90001-2 · Cited by 1,917 · cited 1×
“Using the TMR effect, resistance changes up to 230% at room temperature have been reported [59], [60].”
BackgroundReview of the present status of optical fiber sensors
Lee, B. (2003) · Optical Fiber Technology · doi:10.1016/s1068-5200(02)00527-8 · Cited by 1,736 · cited 4×
“35, that allows it to generate a linear output from the detected signal by building the ratio of the first and second harmonic amplitude level [62], [70].”
BackgroundMethodInfluentialMagnetic sensors and their applications
Lenz, J., & Edelstein, S. (2006) · IEEE Sensors Journal · doi:10.1109/jsen.2006.874493 · Cited by 1,312 · cited 5×
“It has to be noted that this is just one example of a structure that exhibits the GMR effect [33], [50].”
BackgroundInfluentialInductance Calculations Working Formulas and Tables
Snyder, J. N., & Grover, F. C. (1964) · Mathematics of Computation · doi:10.2307/2003443 · Cited by 1,309 · cited 1×
“In reality, the parasitic inductance is determined by the mutual inductance between loop built by the sense wires and the loop built by the main current [1].”
Background230% room-temperature magnetoresistance in CoFeB∕MgO∕CoFeB magnetic tunnel junctions
Djayaprawira, D. D., Tsunekawa, K., Nagai, M., Maehara, H., Yamagata, S., Watanabe, N., Yuasa, S., Suzuki, Y., & Ando, K. (2005) · Applied Physics Letters · doi:10.1063/1.1871344 · Cited by 967 · cited 1×
“Using the TMR effect, resistance changes up to 230% at room temperature have been reported [59], [60].”
BackgroundFiber Optic Sensors: An Introduction for Engineers and Scientists
(2011) · Wiley eBooks · doi:10.1002/9781118014103 · Cited by 783 · cited 1×
“Linear birefringent material behaves vice versa [61].”
Giant magnetic field dependent impedance of amorphous FeCoSiB wire
Beach, R. S., & Berkowitz, A. E. (1994) · Applied Physics Letters · doi:10.1063/1.111170 · Cited by 650
Primdahl, F. (1979) · Journal of Physics E: Scientific Instruments · doi:10.1088/0022-3735/12/4/001 · Cited by 499
Research works printed but not linked: 15
- ziegler, 2008, An isolated current to voltage voltage to voltage converter
- tipler, 2005, Understanding Hall effect devices
- tipler, 2005, An introduction to the Hall effect
- udd, 1991, Fiber Optic SensorsAn Introduction for Engineers and Scientists
- tipler, 1991, Physics for Scientists and Engineers
- ma, 2004, Isolated Current and Voltage Transducers
- baibich, 1997, The giant magnetoresistive head A giant leap for IBM research
- kowina, 2005, high dynamic magnetic beam current measurement by means of optimized magnet-resistance (mr) sensor engineering, Proc 7th Eur Workshop on Beam Diagnostics and Instrumentation for Particle Accelerators DIPAC 2005, 102
- beltran, 2005, AA and AB-series analog sensors datasheet
- mammano, 2005, High-side current-sense measurement
- spaziani, 1997, Using copper PCB etch for low value resistance
- spaziani, 2005, Cu-ETP copper specification
- ray, 2005, RCTrms Rogowski coil datasheet
- mammano, 1997, current sensing solutions for power supply designer, Power Design Seminar SEM 1200
- dezuari, 2003, Basic introduction to the use of magnetoresistive sensors
Cited by
Wei, Z., Zhao, J., He, H., Ding, G., Cui, H., & Liu, L. (2021) · Journal of Power Sources · doi:10.1016/j.jpowsour.2021.229462 · Cited by 348
Monitoring system for photovoltaic plants: A review
Madeti, S. R., & Singh, S. N. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.09.088 · Cited by 313
Battery Management System Hardware Concepts: An Overview
Lelie, M., Braun, T., Knips, M., Nordmann, H., Ringbeck, F., Zappen, H., & Sauer, D. U. (2018) · Applied Sciences · doi:10.3390/app8040534 · Cited by 287
“The measurement range is limited by the accuracy of the voltage measurement [10,31].”
BackgroundMethodGreen extraction techniques in green analytical chemistry
Armenta, S., Garrigues, S., Esteve-Turrillas, F. A., & de la Guardia, M. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.03.016 · Cited by 280
Electric current sensors: a review
Ripka, P. (2010) · Measurement Science and Technology · doi:10.1088/0957-0233/21/11/112001 · Cited by 278
Hall-Effect Current Sensors: Principles of Operation and Implementation Techniques
Crescentini, M., Syeda, S. F., & Gibiino, G. P. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3119766 · Cited by 208
Ouyang, Y., He, J., Hu, J., & Wang, S. (2012) · Sensors · doi:10.3390/s121115520 · Cited by 162
“and GMR effect sensors, and they are mainly based on the following physical principles: Faraday’s law of induction, Ohm's law of resistance, Faraday effect and magnetic field sensors [25,28,29].”
MethodDigital Average Current-Mode Control of PWM DC–DC Converters Without Current Sensors
Qiu, Y., Liu, H., & Chen, X. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2032130 · Cited by 144
“The most serious limitation of Hall-effect sensor is the degaussing cycle required after an over current incident [14].”
BackgroundSoft Magnetic Skin for Continuous Deformation Sensing
Hellebrekers, T., Kroemer, O., & Majidi, C. (2019) · Advanced Intelligent Systems · doi:10.1002/aisy.201900025 · Cited by 152
Komsiyska, L., Buchberger, T., Diehl, S., Ehrensberger, M., Hanzl, C., Hartmann, C., Hölzle, M., Kleiner, J., Lewerenz, M., Liebhart, B., et al. (2021) · Energies · doi:10.3390/en14185989 · Cited by 143
Split-core magnetoelectric current sensor and wireless current measurement application
Lu, C., Zhou, H. D., Li, L., Yang, A., Xu, C., Ou, Z., Wang, J., Wang, X., & Tian, F. (2021) · Measurement · doi:10.1016/j.measurement.2021.110527 · Cited by 129
Industrial power and energy metering – a state-of-the-art review
O’Driscoll, E., & O’Donnell, G. E. (2012) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2012.09.046 · Cited by 128
Yan, Q., Wu, X., Yuan, X., & Geng, Y. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2461632 · Cited by 128
“With the fast response and high precision of Hall sensors [34], and the fast throughput 16-bit A/D chip AD7656 adopted in this paper, the errors caused by the Hall sensors and A/D chips can”
MethodShi, Y., Xin, Z., Loh, P. C., & Blaabjerg, F. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2984055 · Cited by 122
“This is possible because each Rogowski coil is an inexpensive air-coil without a magnetic core [10].”
BackgroundSmart Energy Meters for Smart Grids, an Internet of Things Perspective
Rind, Y. M., Raza, M. H., Zubair, M. F., Mehmood, M. Q., & Massoud, Y. (2023) · Energies · doi:10.3390/en16041974 · Cited by 163
“Isolated current measurement enables non-contact floating voltage measurement using the magnetic field generated by the current flow, allowing greater dynamic ranges and electrical safety [105].”
MethodA DC-Reactor-Based Solid-State Fault Current Limiter for HVdc Applications
Heidary, A., Radmanesh, H. R., Rouzbehi, K., & Pou, J. (2019) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2019.2894521 · Cited by 112
A Novel Closed Loop Current Sensor Based on a Circular Array of Magnetic Field Sensors
Weiss, R. J., Itzke, A., ReitenspieB, J., Hoffmann, I., & Weigel, R. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2887302 · Cited by 95
“TALVANICALLY isolated current sensors utilizing a ferromagnetic core have been widely used for decades in many applications like power electronics, power distribution, electrical drives or renewable power generation to mention just a few examples [1], [2].”
BackgroundInfluence of the Conductor Position on a Circular Array of Hall Sensors for Current Measurement
Itzke, A., Weiss, R. J., & Weigel, R. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2826462 · Cited by 94
“Due to their outstandingly simple and cheap system integration they are widely used in many applications such as power distribution, power electronics, drive technologies, and many more cases where a ferromagnetic core is utilized [1], [2].”
BackgroundIntegrated Fluxgate Magnetometer for Use in Isolated Current Sensing
Snoeij, M. F., Schäffer, V., Udayashankar, S., & Ivanov, M. V. (2016) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2016.2554147 · Cited by 94
“a current transformer at higher frequencies [1], [10], [11], since an ac primary current will induce a voltage in the”
BackgroundMethodInfluentialA High-Bandwidth Integrated Current Measurement for Detecting Switching Current of Fast GaN Devices
Wang, K., Yang, X., Li, H., Wang, L., & Jain, P. K. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2749249 · Cited by 110
“2 shows the schematic diagram of a Rogowski coil, which is composed of a pick-up coil and an integrator [20], [21].”
BackgroundEnergy Harvesting from Fluid Flow Using Piezoelectric Materials: A Review
Naqvi, A., Ali, A., Altabey, W. A., & Kouritem, S. A. (2022) · Energies · doi:10.3390/en15197424 · Cited by 92
“, lower than 2 m/s); and (iii) the voltage level required by electronic devices so that from 1 to 3 V should be delivered by low-speed wind power energy harvesters [70].”
BackgroundA Review of Megahertz Current Sensors for Megahertz Power Converters
Xin, Z., Li, H., Liu, Q., & Loh, P. C. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3136871 · Cited by 95
Optical fiber current sensor research: review and outlook
Wang, R., Xu, S., Li, W., & Wang, X. (2016) · Optical and Quantum Electronics · doi:10.1007/s11082-016-0719-3 · Cited by 90
Advancing fault diagnosis in next-generation smart battery with multidimensional sensors
Xiong, R., Sun, X., Meng, X., Shen, W., & Sun, F. (2024) · Applied Energy · doi:10.1016/j.apenergy.2024.123202 · Cited by 90
An AMR-Based Three-Phase Current Sensor for Smart Grid Applications
Bernieri, A., Ferrigno, L., Laracca, M., & Rasile, A. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2725983 · Cited by 85
“sensors, Faraday’s law of induction [3], [4].”
BackgroundMethodYang, S.-C. (2014) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2014.2358796 · Cited by 84
Crosstalk in Circular Arrays of Magnetic Sensors for Current Measurement
Weiss, R. J., Makuch, R., Itzke, A., & Weigel, R. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2674630 · Cited by 81
“In recent years, magneto resistive sensors and fluxgate sensors with a high sensitivity and linearity have been developed [3]–[6].”
BackgroundSun, K., Wang, J., Burgos, R. P., & Boroyevich, D. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2930048 · Cited by 77
Sensor Technologies for Transmission and Distribution Systems: A Review of the Latest Developments
Swain, A., Elmouatamid, A., Mousa, A., & Pong, P. W. T. (2022) · Energies · doi:10.3390/en15197339 · Cited by 80
“Special Hall effect sensors [57] mounted on the transformer windings can sense the change in leakage flux with winding deformations and help in minimizing the amount of repair and the repair time, saving thousands of dollars.”
BackgroundCurrent Measurement With 3-D Coreless TMR Sensor Array for Inclined Conductor
Zhang, H., Li, F., Guo, H., Yang, Z., & Yu, N. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2914939 · Cited by 70
Tzelepis, D., Psaras, V., Tsotsopoulou, E., Mirsaeidi, S., Dyśko, A., Hong, Q., Dong, X., Blair, S. M., Nikolaidis, V. C., Papaspiliotopoulos, V., et al. (2020) · IEEE Access · doi:10.1109/access.2020.3035905 · Cited by 64
“AMR sensors are usually used in a Wheatstone bridge configuration and demonstrate a high frequency response up to 1 MHz, that is usually limited by the integrated necessary amplification stages to several hundreds of kHz [128], [146].”
BackgroundMethodInfluentialYan, Z., Liu, W., Wang, J., Su, D., Yan, X., & Fan, J. (2018) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2018.2830859 · Cited by 62
“There are many developed available probes and techniques proposed in [3]–[5].”
MethodDas, D., Madichetty, S., Singh, B., & Mishra, S. (2018) · IEEE Journal of Photovoltaics · doi:10.1109/jphotov.2018.2877418 · Cited by 61
“Such sensing element requires low tolerance, high precision, and low temperature drift resistance [3].”
BackgroundBean, J. J., Saito, M., Fukami, S., Sato, H., Ikeda, S., Ohno, H., Ikuhara, Y., & McKenna, K. P. (2017) · Scientific Reports · doi:10.1038/srep45594 · Cited by 60
Movable Noncontact RF Current Measurement on a PCB Trace
Qiu, H., Fang, W., En, Y., Huang, Y., Liu, Y., Lai, P., Chen, Y., & Shi, C. (2017) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2017.2698900 · Cited by 59
“Shunt resistors [1] can be inserted into the current path as a component, while the current shunt probe is relocatable and it is used extensively to measure fast”
BackgroundMethodNibir, S. J., Biglarbegian, M., & Parkhideh, B. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2883639 · Cited by 59
“over the years in the performance and development of the Hall sensors [5], [6].”
BackgroundZhu, K., Han, W., Lee, W. K., & Pong, P. W. T. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2651886 · Cited by 57
“Unluckily, due to the unavoidable physical connection with the primary circuit, there are a series of problems [9].”
BackgroundTunnel Magnetoresistance-Based Short-Circuit and Over-Current Protection for IGBT Module
Shao, S., Yu, N., Xu, X., Bai, J., Wu, X., & Zhang, J. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2980680 · Cited by 59
“The change in resistance is about 2%–4% as the magnetization in the layer rotates from parallel to perpendicular to the direction of current flow [20].”
BackgroundMethodInfluentialAdvancements, Challenges, and Future Trajectories in Advanced Battery Safety Detection
Wei, Y., Wang, M., Zhang, M., Cai, T., Huang, Y., & Xu, M. (2025) · Electrochemical Energy Reviews · doi:10.1007/s41918-025-00245-0 · Cited by 77
“…for LIB safety, covering current and voltage monitoring, temperature sensing, stress analysis, gas detection, and non-destructive evaluation, summarized and compared in A m b i e n t t e m p e r a - t u r e [ 130 –133 ] E a s y t o d e v i a t e und e r l a r g e c u r-r e n t s [ 130 –133 ] 0 .”
PVSMS: A system for quantifying soiling effects and optimizing cleaning schedule in PV solar plants
Abraim, M., Ydrissi, M. E., Ghennioui, H., Ghennioui, A., Hanrieder, N., Wilbert, S., Alani, O. E., Boujoudar, M., & Azouzoute, A. (2023) · Energy Conversion and Management · doi:10.1016/j.enconman.2023.116978 · Cited by 55
Measurement of DC Currents in the Power Grid by Current Transformer
Ripka, P., Draxler, K., & Styblíková, R. (2012) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2012.2216862 · Cited by 55
“Optical current sensors and currents sensors based on Hall technology are affected by DC offset drifts [2], while giant magnetoimpedance (GMI) and magnetoresistive (MR) current sensors have limited dynamic range [3].”
BackgroundOptical Current Transducers and Error Sources in Them: A Review
Samimi, M. H., Akmal, A. A. S., & Mohseni, H. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2015.2428652 · Cited by 54
“ALTHOUGH Optical Current Transducers (OCTs) have great benefits over conventional Current Transformers (CTs) [1]–[4] and have been developed vastly in recent decades [5]–[9], it is not trivial to construct an appropriate OCT in real conditions [10].”
BackgroundNew Small-Volume High-Precision TMR Busbar DC Current Sensor
Xu, X. P., Liu, T., Zhu, M., & Wang, J. G. (2020) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2019.2953671 · Cited by 54
“IN NEW energy systems, such as photovoltaics, wind power, electric vehicles, and so on, the use of current sensors has increased year by year due to non-contact isolation measurement, high precision, and low cost [1], [2].”
BackgroundDesign and Development of an IoT Smart Meter with Load Control for Home Energy Management Systems
Munoz, O., Ruelas, A., Rosales-Escobedo, P. F., Acuña, A., Suastegui, A., & Lara, F. (2022) · Sensors · doi:10.3390/s22197536 · Cited by 52
“The above is not the case of current transformers or some Hall effect sensors [29].”
BackgroundParasitic Capacitive Couplings in Medium Voltage Power Electronic Systems: An Overview
Kjærsgaard, B. F., Liu, G., Nielsen, M. R., Wang, R., Dalal, D. N., Aunsborg, T. S., Jørgensen, J. K., Yan, Z., Jacobsen, J., Wu, R. L., et al. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3269582 · Cited by 55
“to be the dominant current sensing technologies utilized within the field of isolated current sensors for LV applications [238].”
BackgroundEstimating SoC, SoH, or RuL of Rechargeable Batteries via IoT: A Review
Bokstaller, J., Schneider, J., & Brocke, J. V. (2023) · IEEE Internet of Things Journal · doi:10.1109/jiot.2023.3342367 · Cited by 56
“The current flows through the copper conduction path and thereby creates a magnetic field which is measured and converted [90].”
BackgroundYan, Q., Wu, X., Yuan, X., Geng, Y., & Zhang, Q. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2350485 · Cited by 50
“, from dc to several hundred kilohertz) [36].”
BackgroundPerformance Improvement of Slow-Wave Rogowski Coils for High Impulse Current Measurement
Metwally, I. A. (2012) · IEEE Sensors Journal · doi:10.1109/jsen.2012.2222372 · Cited by 50
“Rigid coils usually have a higher sensitivity since they allow more turns than flexible ones, and thus they provide a lower cutoff frequency [2], [5].”
BackgroundInfluentialNon-Contact Voltage Monitoring of HVDC Transmission Lines Based on Electromagnetic Fields
Zhu, K., Lee, W. K., & Pong, P. W. T. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2892498 · Cited by 48
Systematic review of the data acquisition and monitoring systems of photovoltaic panels and arrays
Kalay, M. Ş., Kılıç, B., & Sağlam, Ş. (2022) · Solar Energy · doi:10.1016/j.solener.2022.08.029 · Cited by 47
White, T. P., Shetty, S., Ware, M. E., Mantooth, H. A., & Salamo, G. J. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2794264 · Cited by 47
“2794264 high power dissipation would be a great benefit to circuit designers [8]–[10].”
BackgroundWei, Z., Hu, J. P., Li, Y., He, H., Li, W., & Sauer, D. U. (2021) · Applied Energy · doi:10.1016/j.apenergy.2021.118246 · Cited by 45
A Technique to Enhance the Frequency Bandwidth of Contactless Magnetoresistive Current Sensors
Nibir, S. J., Hurwitz, E. N., Karami, M., & Parkhideh, B. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2561264 · Cited by 46
“the past years [4]–[6].”
Lim, B., Mahfoud, M., Das, P. T., Jeon, T., Jeon, C., Kim, M., Nguyen, T.-K., Hung, T. Q., Terki, F., & Kim, C. (2022) · APL Materials · doi:10.1063/5.0087311 · Cited by 50
Giant-Magnetoresistance-Based Galvanically Isolated Voltage and Current Measurements
Xie, F., Weiss, R. J., & Weigel, R. (2015) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2015.2440553 · Cited by 45
Highly sensitive MEMS magnetic field sensors with integrated powder-based permanent magnets
Niekiel, F., Su, J., Bodduluri, M. T., Lisec, T., Blohm, L., Pieper, I., Wagner, B., & Lofink, F. (2019) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2019.111560 · Cited by 45
YoMo: the Arduino-based smart metering board
Klemenjak, C., Egarter, D., & Elmenreich, W. (2015) · Computer Science - Research and Development · doi:10.1007/s00450-014-0290-8 · Cited by 44
Castro, N., Reis, S., Silva, M. P., Correia, V. M. G., Lanceros-Méndez, S., & Martins, P. (2018) · Smart Materials and Structures · doi:10.1088/1361-665x/aab969 · Cited by 42
“This sensor provides electrical isolation between the measured current and the output signal, but it is unable of measuring DC currents [3].”
BackgroundRen, R., & Zhang, J. (2021) · Journal of Computing in Civil Engineering · doi:10.1061/(asce)cp.1943-5487.0000971 · Cited by 55
High-Bandwidth Combinational Rogowski Coil for SiC MOSFET Power Module
Zhang, W., Sohid, S. B., Wang, F., Cui, H., & Holzinger, B. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3127545 · Cited by 43
Meng, L., Gao, P., Haji, M. M., & Xu, W. (2015) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2015.2419032 · Cited by 42
“By contrast, indirect means are widely utilized for current measurement in which voltage or magnetic field related to the current is sensed [1].”
BackgroundNibir, S. J., & Parkhideh, B. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2739711 · Cited by 41
A Coreless Electric Current Sensor With Circular Conductor Positioning Calibration
Chan, J. Y. C., Tse, N. C. F., & Lai, L. L. (2013) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2013.2266051 · Cited by 40
“As magnetic core is not provided, this sensor is normally fixed onto print circuit board (PCB), and must be in close proximity with the current-carrying path [15], [16].”
BackgroundLi, Y., Motz, M., & Raghavan, L. (2019) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2019.2909161 · Cited by 44
“There are many current sensing techniques available for a wide range of applications [2].”
BackgroundElectronic Energy Meter Based on a Tunnel Magnetoresistive Effect (TMR) Current Sensor
Vidal, E. G., Muñoz, D. R., Arias, S. I. R., Moreno, J. S., Cardoso, S., Ferreira, R., & Freitas, P. P. (2017) · Materials · doi:10.3390/ma10101134 · Cited by 39
“Hall-effect-based sensors need high permeability materials such as ferrites and, although isolation is well-provided, they have high volume and weight [27,28].”
BackgroundTMR Busbar Current Sensor With Good Frequency Characteristics
Xu, X. P., Wang, S., Liu, T., Zhu, M., & Wang, J. G. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3089775 · Cited by 39
Teler, K., Skowron, M., & Orłowska-Kowalska, T. (2023) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2023.3336348 · Cited by 42
“For applications requiring high-precision measurements and immunity to external disturbances (temperature, magnetic field), closed-loop Hall effect transducers are used, which include a compensating circuit in their structure [22].”
MethodContactless Current Measurement for Enclosed Multiconductor Systems Based on Sensor Array
Geng, G., Wang, J., Chen, K., & Xu, W. (2017) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2017.2711898 · Cited by 38
“CURRENT sensing is one of the basic measurement techniques for modern power systems, ranging from residential, industrial to utility practices [1].”
BackgroundInfinity Sensor: Temperature Sensing in GaN Power Devices using Peak di/dt
Wang, J., Hedayati, M. H., Liu, D., Adami, S.-E., Dymond, H. C. P., Dalton, J. J. O., & Stark, B. H. (2018) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2018.8558287 · Cited by 38
“Third, due to the extreme rates of change of current and voltage, noise immunity is a significant concern [10].”
BackgroundNonlinear models of power inductors: A survey
Oliveri, A., Lodi, M., & Storace, M. (2021) · International Journal of Circuit Theory and Applications · doi:10.1002/cta.3147 · Cited by 43
“Voltages are usually easy to measure, whereas the measurement of current is often an issue.(83,84) Shunt resistors can be exploited, which are very simple but have low accuracy, modify the circuit and increase the power loss.”
BackgroundA Fully Isolated Delta-Sigma ADC for Shunt Based Current Sensing
Tan, Z., Mueck, M., Du, X. H., Getzin, L., Guidry, M., Keating, S., Xing, X., Zhao, F., & Chen, B. (2016) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2016.2581800 · Cited by 37
“The current flow in power lines is usually measured at the output of an isolated sensor such as a current transformer (CT) or a Rogowski coil or directly across a nonisolated sensor such as a shunt resistor [1]–[3].”
BackgroundA Smart IGBT Gate Driver IC With Temperature Compensated Collector Current Sensing
Chen, J., Zhang, W. J., Shorten, A., Yu, J., Sasaki, M., Kawashima, T., Nishio, H., & Ng, W. T. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2865788 · Cited by 37
“Different current sensing techniques have been reviewed in [24]–[26].”
Coaxial-Cable Wound Rogowski Coils for Measuring Large-Magnitude Short-Duration Current Pulses
Metwally, I. A. (2012) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2012.2212512 · Cited by 37
“These principles are as the following [1], [4]: 1) Ohm’s law of resistance; 2) Faraday’s law of induction; 3) magnetic field sensors; and 4) Faraday effect.”
BackgroundInfluentialA Lithium-Ion Battery Current Estimation Technique Using an Unknown Input Observer
Cambron, D., & Cramer, A. M. (2017) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2017.2657520 · Cited by 37
Tunnel Magnetoresistance-Based Noncontact Current Sensing and Measurement Method
Li, J., Liu, H., & Bi, T. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3152240 · Cited by 36
Industrial Inverter Current Sensing With Three Shunt Resistors: Limitations and Solutions
Zhang, Z., Leggate, D., & Matsuo, T. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2596778 · Cited by 36
“Various current sensing methods, such as Hall effect sensors, current transforms, shunts, Rogowski coils, and magnetoresistance effect sensors have been developed and reviewed in [1] and [2].”
MethodPhase Loss Detection Using Current Signals: A Review
Dianov, A., & Anuchin, A. (2021) · IEEE Access · doi:10.1109/access.2021.3105483 · Cited by 39
“The current signals can be measured by sensors utilizing different physical principles considered in detail in [52]–[54], however the most popular devices are hall-effect [55], [56] or shunt sensors.”
BackgroundRealization and optimization of bus bar current transducers based on Hall effect sensors
Blagojević, M., Jovanović, U., Jovanovic, I. D., Mančić, D. D., & Popović, R. S. (2016) · Measurement Science and Technology · doi:10.1088/0957-0233/27/6/065102 · Cited by 36
Intelligent System for Identification of Wheelchair User’s Posture Using Machine Learning Techniques
Rosero-Montalvo, P. D., Peluffo-Ordóñez, D. H., López, V. F., Serrano, J., & Rosero, E. A. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2885323 · Cited by 35
“The analog signals obtained from the sensors were digital converted with an Arduino nano micro-controller with Ohm’s law of resistance sensing technique [20].”
MethodMetwally, I. A. (2013) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2013.2255994 · Cited by 35
Wang, N., Zhang, Z., Li, Z., He, Q., Lin, F., & Lu, Y. (2016) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2524042 · Cited by 35
“PRECISION measurement of dc high-current is usually realized by second harmonic fluxgate current transducers [1], [2].”
BackgroundShalmany, S. H., Draxelmayr, D., & Makinwa, K. A. A. (2017) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2016.2639535 · Cited by 34
“CURRENT-sensing systems (CSSs) are widely used in many industrial applications, such as motor controllers, battery fuel gauges, and energy monitoring systems [1]–[15].”
BackgroundInfluentialIndustrial Comparator for Smart Grid Sensor Calibration
Crotti, G., Gallo, D., Giordano, D., Landi, C., & Luiso, M. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2724299 · Cited by 34
“Low power output, non-conventional instrument transformers, which in general show better performances than the inductive conventional ones, are rapidly diffusing for power system monitoring applications [12], [13].”
BackgroundContactless measurement of electric current using magnetic sensors
Ripka, P. (2019) · tm - Technisches Messen · doi:10.1515/teme-2019-0032 · Cited by 34
“This paper concentrates on advances in current sensors in the period of almost a decade since [7] and [8] were published.”
BackgroundThin-Film-Based SAW Magnetic Field Sensors
Meyer, J., Schell, V., Su, J., Fichtner, S., Yarar, E., Niekiel, F., Giese, T., Kittmann, A., Thormählen, L., Lebedev, V., et al. (2021) · Sensors · doi:10.3390/s21248166 · Cited by 34
“The sensing of magnetic fields has a multitude of use cases ranging from biomedical applications to current sensing in automotive applications [1–5], each having different requirements on the sensor regarding bandwidth, dynamic range, dc capability, size, and price [6,7].”
BackgroundChen, K. (2016) · doi:10.1002/9781118896846.ch8 · Cited by 34
Short Circuit Protection of Silicon Carbide MOSFETs: Challenges, Methods, and Prospects
Zhang, M., Li, H., Yang, Z., Zhao, S., Wang, X., & Ding, L. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3430897 · Cited by 44
Self-Oscillating Fluxgate-Based Quasi-Digital Sensor for DC High-Current Measurement
Wang, N., Zhang, Z., Li, Z., Zhang, Y., He, Q., Han, B., & Lu, Y. (2015) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2015.2444258 · Cited by 33
Ming, L., Xin, Z., Liu, W., & Loh, P. C. (2019) · IET Power Electronics · doi:10.1049/iet-pel.2019.0694 · Cited by 32
Shenil, P. S., & George, B. (2020) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2020.3044757 · Cited by 32
“Techniques utilizing the magnetic field due to the current are available for noncontact measurement of the current [5]–[7], while nonintrusive voltage sensing techniques are still evolv-”
BackgroundResonance based DC current sensor
Kumar, B., Kaluvan, S., Kumar, U. V., Uma, G., & Umapathy, M. (2011) · Measurement · doi:10.1016/j.measurement.2011.11.008 · Cited by 31
Yu, H., Qian, Z., Liu, H., & Qu, J. (2018) · Sensors · doi:10.3390/s18020578 · Cited by 31
“[13]), the circular array of magnetic sensors is considered to be an effective scheme to achieve low-cost, large linear range, wide frequency bandwidth [14–16], light weight, and high reliability.”
BackgroundCollocated and Simultaneous Measurements of RF Current and Voltage on a Trace in a Noncontact Manner
Luo, C., Fang, W., Shen, Y., Qiu, H., Shao, W., Hong, Z., Wang, L., He, Z., & En, Y. (2019) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2019.2905204 · Cited by 31
“A direct touching method [4] (shunt [5], Faraday-effect sensor [6]–[9], and Hall-effect sensor [10]) is common, but it could change the originally detected signal in the circuit and deteriorate the measurement accuracy.”
BackgroundApplications of Sensors in Solar Energy Systems
Rao, C. K., Sahoo, S. K., Balamurugan, M., Satapathy, S. R., Patnaik, A., & Yanine, F. F. (2020) · International Conference on Renewable Energy Integration into Smart Grids: A Multidisciplinary Approach to Technology Modelling and Simulation (ICREISG) · doi:10.1109/icreisg49226.2020.9174190 · Cited by 31
Phase Loss Detection Using Voltage Signals and Motor Models: A Review
Dianov, A., & Anuchin, A. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3120887 · Cited by 31
A A Integrated Current-Sensing System With % Gain Error and 16 μA Offset From to
Shalmany, S. H., Draxelmayr, D., & Makinwa, K. A. A. (2016) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2015.2511168 · Cited by 30
“are not suitable for dc and/or small (sub-milliampere) current measurement, and tend to be quite bulky [4].”
BackgroundDu, J., Tao, Y., Liu, Y., Ma, L., Zhang, W., & He, Z. (2016) · Optics Express · doi:10.1364/oe.24.017980 · Cited by 30
Au-Free AlGaN/GaN MIS-HEMTs With Embedded Current Sensing Structure for Power Switching Applications
Sun, R., Liang, Y. C., Yeo, Y., & Zhao, C. (2017) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2017.2717934 · Cited by 30
“A variety of current sensing configurations in Si-based power switching applications have been reported, such as by current mirror [4], sense FET [5], and other methods, including the integrated sense FET or similar current sensing structures built in silicon power MOSFETs [6]–[9].”
BackgroundDecoupled Dual-PWM Control for Naturally Commutated Current-Fed Dual-Active-Bridge DC/DC Converter
Zhang, Y., Wang, Z., Li, Y., Hou, N., & Cheng, M. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2933316 · Cited by 30
Ayambire, P. N., Huang, Q. P., Cai, D., Bamisile, O., & Anane, P. O. K. (2020) · Electric Power Systems Research · doi:10.1016/j.epsr.2020.106508 · Cited by 30
Metadata
- Authors
- Ziegler, S., Woodward, R. C., Iu, H. H.-C., & Borle, L. J.
- Affiliations
- The University of Western Australia (AU)
- Venue
- IEEE Sensors Journal
- Published
- 2009-04
- Volume
- 9
- Issue
- 4
- Pages
- 354-376
- ISSN
- 1530-437X (ISSN-L)
- OpenAlex
- W2127394451
- Cited by
- 774
- References
- 63
- Citations by year
- 2026: 37 · 2025: 65 · 2024: 63 · 2023: 70 · 2022: 66 · 2021: 66 · 2020: 63 · 2019: 65 · 2018: 65 · 2017: 46 · 2016: 38 · 2015: 34 · 2014: 33 · 2013: 19 · 2012: 24
- FWCI
- 11.38
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Sensors Journal (publishedVersion)
- UWA Profiles and Research Repository (UWA) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Physical Sciences › Physics and Astronomy › Instrumentation › Sensor Technology and Measurement Systems
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- current sensing, current sensor, sensor principles, sensor characteristics, current measurement
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.