A Sensor System for Automatic Detection of Food Intake Through Non-Invasive Monitoring of Chewing
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Objective and automatic sensor systems to monitor ingestive behavior of individuals arise as a potential solution to replace inaccurate method of self-report. This paper presents a simple sensor system and related signal processing and pattern recognition methodologies to detect periods of food intake based on non-invasive monitoring of chewing. A piezoelectric strain gauge sensor was used to capture movement of the lower jaw from 20 volunteers during periods of quiet sitting, talking and food consumption. These signals were segmented into non-overlapping epochs of fixed length and processed to extract a set of 250 time and frequency domain features for each epoch. A forward feature selection procedure was implemented to choose the most relevant features, identifying from 4 to 11 features most critical for food intake detection. Support vector machine classifiers were trained to create food intake detection models. Twenty-fold cross-validation demonstrated per-epoch classification accuracy of 80.98% and a fine time resolution of 30 s. The simplicity of the chewing strain sensor may result in a less intrusive and simpler way to detect food intake. The proposed methodology could lead to the development of a wearable sensor system to assess eating behaviors of individuals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LIBSVM: A library for support vector machines
Chang, C.-C., & Lin, C.-J. (2011) · ACM Transactions on Intelligent Systems and Technology · doi:10.1145/1961189.1961199 · Cited by 40,918
Libsvm : A library for support vector machines
Ferrari, V. (2008) · Medical Entomology and Zoology · Cited by 10,123
Wrappers for feature subset selection
Kohavi, R., & John, G. H. (1997) · Artificial Intelligence · doi:10.1016/s0004-3702(97)00043-x · Cited by 8,947 · cited 1×
“A forward selection procedure [30] was used to find a subset with the most relevant features based on 20-fold cross-valida-”
MethodMarkers of the Validity of Reported Energy Intake
Livingstone, M. B. E., & Black, A. E. (2003) · The Journal of Nutrition · doi:10.1093/jn/133.3.895s · Cited by 1,081 · cited 1×
“Existing methods such as food recall, food-frequency questionnaires [4], [5], self-report diaries [6], [7] and multimedia diaries [8] suffer from low accuracy as people tend to miscalculate and underreport the food consumed leading to an inaccurate measurement of the daily energy intake [9], [10].”
MethodThe support vector machine under test
Meyer, D., Leisch, F., & Hornik, K. (2003) · Neurocomputing · doi:10.1016/s0925-2312(03)00431-4 · Cited by 777 · cited 1×
“Support Vector Machines (SVM) is a supervised machine learning technique that have been used for classification of wide variety of data sets showing outstanding performance in most cases [31].”
Black, A. E., Goldberg, G. R., Jebb, S. A., Livingstone, M. B. E., Cole, T. J., & Prentice, A. M. (1991) · PubMed · Cited by 645
Day, N. (2001) · International Journal of Epidemiology · doi:10.1093/ije/30.2.309 · Cited by 412 · cited 1×
“Existing methods such as food recall, food-frequency questionnaires [4], [5], self-report diaries [6], [7] and multimedia diaries [8] suffer from low accuracy as people tend to miscalculate and underreport the food consumed leading to an inaccurate measurement of the daily energy intake [9], [10].”
MethodNeed for Technological Innovation in Dietary Assessment
Thompson, F. E., Subar, A. F., Loria, C. M., Reedy, J. L., & Baranowski, T. (2010) · Journal of the American Dietetic Association · doi:10.1016/j.jada.2009.10.008 · Cited by 349 · cited 1×
“Incorporation of new technology helped participants to automatically report food consumption [11].”
BackgroundEffect of Texture of Plastic and Elastic Model Foods on the Parameters of Mastication
Foster, K. D., Woda, A., & Peyron, M. A. (2006) · Journal of Neurophysiology · doi:10.1152/jn.01003.2005 · Cited by 311 · cited 1×
“The food items consumed during the meal period were selected to represent different physical properties of everyday foods, specifically, different chewing properties such “hardness”, “crunchiness” and “tackiness” [26], [27].”
MethodInfluence of Age on Adaptability of Human Mastication
Peyron, M.-A., Blanc, O., Lund, J. P., & Woda, A. (2004) · Journal of Neurophysiology · doi:10.1152/jn.01122.2003 · Cited by 238 · cited 1×
“Indeed, previous studies [21] indicate that variations in the jaw motion during chewing differ less between individuals and have well-defined narrow frequency range between 1–2 Hz.”
BackgroundRecognition of dietary activity events using on-body sensors
Amft, O., & Tröster, G. (2008) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2007.11.007 · Cited by 220 · cited 1×
“Another wearable sensor that detected food intake by capturing chewing sounds was presented in [15].”
BackgroundEnergy density and portion size: their independent and combined effects on energy intake
Kral, T. V. E., & Rolls, B. J. (2004) · Physiology & Behavior · doi:10.1016/j.physbeh.2004.04.063 · Cited by 212
Evidence-Based Development of a Mobile Telephone Food Record
Six, B. L., Schap, T. E., Zhu, F. M., Mariappan, A., Bosch, M., Delp, E. J., Ebert, D. S., Kerr, D. A., & Boushey, C. J. (2010) · Journal of the American Dietetic Association · doi:10.1016/j.jada.2009.10.010 · Cited by 200 · cited 1×
“In [13], a similar methodology for mobile phone food record was proposed.”
MethodThe regulation of masticatory function and food bolus formation
WODA, A., MISHELLANY, A., & PEYRON, M. (2006) · Journal of Oral Rehabilitation · doi:10.1111/j.1365-2842.2006.01626.x · Cited by 187 · cited 1×
“This finding corresponds well with the finding of earlier studies [28], [29] that determined chewing frequency to be in the range 0.”
ResultNon-invasive monitoring of chewing and swallowing for objective quantification of ingestive behavior
Sazonov, E., Schuckers, S., Lopez-Meyer, P., Makeyev, O., Sazonova, N., Melanson, E. L., & Neuman, M. (2008) · Physiological Measurement · doi:10.1088/0967-3334/29/5/001 · Cited by 179 · cited 7×
“In [17] we determined that the best sensor location is immediately below the outer ear (Fig.”
BackgroundMethodSelf-citationEffects of sample hardness on human chewing force: a model study using silicone rubber
Kohyama, K., Hatakeyama, E., Sasaki, T., Dan, H., Azuma, T., & Karita, K. (2004) · Archives of Oral Biology · doi:10.1016/j.archoralbio.2004.04.006 · Cited by 179 · cited 1×
“The food items consumed during the meal period were selected to represent different physical properties of everyday foods, specifically, different chewing properties such “hardness”, “crunchiness” and “tackiness” [26], [27].”
MethodA Wearable Electronic System for Objective Dietary Assessment
Sun, M., Fernstrom, J. D., Jia, W., Hackworth, S. A., Yao, N., Li, Y., Li, C., Fernstrom, M. H., & Sclabassi, R. J. (2010) · Journal of the American Dietetic Association · doi:10.1016/j.jada.2009.10.013 · Cited by 159 · cited 1×
“In [14], a wearable device that integrates a miniature camera, a microphone and several other sensors (accelerometers, reference lights, etc) for recording food intake was presented.”
BackgroundSazonov, E. S., Makeyev, O., Schuckers, S., Lopez-Meyer, P., Melanson, E. L., & Neuman, M. R. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2033037 · Cited by 157 · cited 2×
“In [20] we presented an acoustical method for detection of swallowing events that could be used as the source of data for methods in [17], [18].”
MethodSelf-citationA wearable earpad sensor for chewing monitoring
Amft, O. (2010) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2010.5690449 · Cited by 133 · cited 4×
“The presented food intake sensor is based on a very simple principle of capturing skin strain during chewing events rather than chewing sound [16].”
BackgroundInfluentialde Castro, J. M. (1994) · Appetite · doi:10.1006/appe.1994.1045 · Cited by 122 · cited 1×
“Existing methods such as food recall, food-frequency questionnaires [4], [5], self-report diaries [6], [7] and multimedia diaries [8] suffer from low accuracy as people tend to miscalculate and underreport the food consumed leading to an inaccurate measurement of the daily energy intake [9], [10].”
MethodWeiss, R., Stumbo, P. J., & Divakaran, A. (2010) · Journal of the American Dietetic Association · doi:10.1016/j.jada.2009.10.011 · Cited by 75 · cited 1×
“In [12], custom designed software was integrated into a mobile phone with a camera to capture images of foods before and after the meal as well as to include additional food information using voice record.”
MethodToward Objective Monitoring of Ingestive Behavior in Free‐living Population
Sazonov, E. S., Schuckers, S. A. C., Lopez‐Meyer, P., Makeyev, O., Melanson, E. L., Neuman, M. R., & Hill, J. O. (2009) · Obesity · doi:10.1038/oby.2009.153 · Cited by 74 · cited 4×
“In [20] we presented an acoustical method for detection of swallowing events that could be used as the source of data for methods in [17], [18].”
BackgroundMethodInfluentialSelf-citationMetabolism or appetite: questions of energy balance with particular reference to obesity
Prentice, A. M., Black, A. E., Murgatroyd, P. R., Goldberg, G. R., & Coward, W. A. (1989) · Journal of Human Nutrition and Dietetics · doi:10.1111/j.1365-277x.1989.tb00014.x · Cited by 66 · cited 1×
“Existing methods such as food recall, food-frequency questionnaires [4], [5], self-report diaries [6], [7] and multimedia diaries [8] suffer from low accuracy as people tend to miscalculate and underreport the food consumed leading to an inaccurate measurement of the daily energy intake [9], [10].”
MethodKaczkowski, C. H., Jones, P. J. H., Feng, J.-Y., & Bayley, H. S. (2000) · Journal of Nutrition · doi:10.1093/jn/130.4.802 · Cited by 66 · cited 1×
“Existing methods such as food recall, food-frequency questionnaires [4], [5], self-report diaries [6], [7] and multimedia diaries [8] suffer from low accuracy as people tend to miscalculate and underreport the food consumed leading to an inaccurate measurement of the daily energy intake [9], [10].”
MethodEnergy Intake and Energy Expenditure
CHAMPAGNE, C. M., BRAY, G. A., KURTZ, A. A., MONTEIRO, J. B. R., TUCKER, E., VOLAUFOVA, J., & DELANY, J. P. (2002) · Journal of the American Dietetic Association · doi:10.1016/s0002-8223(02)90316-0 · Cited by 59 · cited 1×
“Existing methods such as food recall, food-frequency questionnaires [4], [5], self-report diaries [6], [7] and multimedia diaries [8] suffer from low accuracy as people tend to miscalculate and underreport the food consumed leading to an inaccurate measurement of the daily energy intake [9], [10].”
MethodDetection of Food Intake from Swallowing Sequences by Supervised and Unsupervised Methods
Lopez‐Meyer, P., Makeyev, O., Schuckers, S., Melanson, E. L., Neuman, M. R., & Sazonov, E. E. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-0019-1 · Cited by 35 · cited 2×
“In [19], supervised group models and unsupervised individual models were trained to detect food intake by using swallowing alone with 89% recognition accuracy for group models and 93.”
MethodSelf-citationHow do we get fat? An epidemiologic and metabolic approach
Bray, G. A. (2004) · Clinics in Dermatology · doi:10.1016/j.clindermatol.2004.01.009 · Cited by 35
Impact of Morbid Obesity on Chewing Ability
Veyrune, J.-L., Chaussain, C., Czernichow, S., Ciangura, C., Nicolas, E., & Hennèquin, M. (2008) · Obesity Surgery · doi:10.1007/s11695-008-9443-9 · Cited by 34 · cited 1×
“This finding corresponds well with the finding of earlier studies [28], [29] that determined chewing frequency to be in the range 0.”
ResultFueki, K., Sugiura, T., Yoshida, E., & Igarashi, Y. (2008) · Journal of Oral Rehabilitation · doi:10.1111/j.1365-2842.2008.01849.x · Cited by 32 · cited 1×
“Surface Electromyography (EMG) [22] can sense the activation of jaw muscles during mastication by placing electrodes over the skin surface.”
Background
Cited by
Hutchesson, M. J., Rollo, M. E., Krukowski, R., Ells, L., Harvey, J., Morgan, P. J., Callister, R., Plotnikoff, R., & Collins, C. E. (2015) · Obesity Reviews · doi:10.1111/obr.12268 · Cited by 380
Detecting Periods of Eating During Free-Living by Tracking Wrist Motion
Dong, Y., Scisco, J., Wilson, M., Muth, E., & Hoover, A. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2013.2282471 · Cited by 227
“Sazonov and colleagues studied the recognition of chews [22] and swallows [24].”
BackgroundMethodInfluentialAutomatic Ingestion Monitor: A Novel Wearable Device for Monitoring of Ingestive Behavior
Fontana, J. M., Farooq, M., & Sazonov, E. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2306773 · Cited by 204
“For example, a group (population-based) model created in our previous study with a database encompassing chewing information from 20 subjects achieved an accuracy of 81% under laboratory settings [17].”
MethodInfluentialSelf-citationProgress in the Applications of Smart Piezoelectric Materials for Medical Devices
Zaszczyńska, A., Gradys, A., & Sajkiewicz, P. (2020) · Polymers · doi:10.3390/polym12112754 · Cited by 192
Wearable Food Intake Monitoring Technologies: A Comprehensive Review
Vu, T., Lin, F., Alshurafa, N., & Xu, W. (2017) · Computers · doi:10.3390/computers6010004 · Cited by 170
“Sazonov and Fontana [86] embedded a strain sensor below the outer ear to capture the motion of the lower jaw caused by the posterior border of the mandible’s ramus relative to the temporal bone [87].”
Background
Metadata
- Authors
- Sazonov, E. S., & Fontana, J. M.
- Venue
- IEEE Sensors Journal
- Published
- 2012-05
- Volume
- 12
- Issue
- 5
- Pages
- 1340-1348
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- OpenAlex
- W2141690328
- Cited by
- 163
- References
- 29
- FWCI
- 5.87
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.