Wireless Wearable Magnetometer-Based Sensor for Sleep Quality Monitoring
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Obstructive sleep apnoea is one of the most common sleep disorders, which is characterized by the repetitive cessations of respiratory flow during sleep. This paper describes an alternative method to detect sleep parameters by measuring a variation in the earth's magnetic field. A magnetometer sensor, laid onto the body, detects millimeter night-time breathing movements by measuring the change in the magnetic vectors. A soft, non-invasive wearable sensor is designed to be printed on a miniature printed circuit board, packaged in a minimal invasive board, which includes a wireless Bluetooth low-energy (BLE) module and a low-power microcontroller. A very low power consumption is achieved by applying a smart processing algorithm, which is also described. The algorithm delivers respiration rate, apnoea time, and time in movement. A comparison with a well-known air-flow sensor is also discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Smart Homes that Monitor Breathing and Heart Rate
Adib, F., Mao, H., Kabelac, Z., Katabi, D., & Miller, R. C. (2015) · Proceedings of the 33rd Annual ACM Conference on Human Factors in Computing Systems · doi:10.1145/2702123.2702200 · Cited by 916
Wireless body sensor networks for health-monitoring applications
Hao, Y., & Foster, R. (2008) · Physiological Measurement · doi:10.1088/0967-3334/29/11/r01 · Cited by 404
Breathing Detection: Towards a Miniaturized, Wearable, Battery-Operated Monitoring System
Corbishley, P., & Rodriguez-Villegas, E. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.910679 · Cited by 221 · cited 1×
“Airflow sensors detect the breathing airflow measuring a temperature variation at nose level [17]–[21].”
BackgroundFekr, A. R., Radecka, K., & Zilic, Z. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2015.2445783 · Cited by 61 · cited 1×
“work [8].”
Lee, Y., Lee, B., & Lee, M. (2010) · Telemedicine and e-Health · doi:10.1089/tmj.2009.0039 · Cited by 19 · cited 1×
“Many devices have been designed to address the main parameters for this disease [10], [11].”
Background
Cited by
Contact-Based Methods for Measuring Respiratory Rate
Massaroni, C., Nicolò, A., Lo Presti, D., Sacchetti, M., Silvestri, S., & Schena, E. (2019) · Sensors · doi:10.3390/s19040908 · Cited by 426
Ultrasensitive Magnetic Field Sensors for Biomedical Applications
Murzin, D., Mapps, D. J., Levada, K., Belyaev, V., Omelyanchik, A., Panina, L., & Rodionova, V. (2020) · Sensors · doi:10.3390/s20061569 · Cited by 277
“This can be critical, for example, for patients with obstructive sleep apnea [238].”
BackgroundKhan, S., Ali, S., & Bermak, A. (2019) · Sensors · doi:10.3390/s19051230 · Cited by 253
A Rigid-Flex Wearable Health Monitoring Sensor Patch for IoT-Connected Healthcare Applications
Wu, T., Wu, F., Qiu, C., Redoute, J.-M., & Yuce, M. R. (2020) · IEEE Internet of Things Journal · doi:10.1109/jiot.2020.2977164 · Cited by 224
“In [10], a small magnetometer-based sensor was designed to measure RR and the apnoea time during sleep.”
MethodHuman Vital Signs Detection Methods and Potential Using Radars: A Review
Kebe, M., Gadhafi, R., Mohammad, B., Sanduleanu, M., Saleh, H., & Al-Qutayri, M. (2020) · Sensors · doi:10.3390/s20051454 · Cited by 205
“Sensors 2020 , 20 , x FOR PEER REVIEW”
Metadata
- Authors
- Milici, S., Lazaro, A., Villarino, R., Girbau, D., & Magnarosa, M.
- Venue
- IEEE Sensors Journal
- Published
- 2018-03-01
- Volume
- 18
- Issue
- 5
- Pages
- 2145-2152
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- 2379-9153
- OpenAlex
- W2782837544
- Cited by
- 83
- References
- 5
- FWCI
- 4.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.