An Implantable 64-Channel Wireless Microsystem for Single-Unit Neural Recording
Abstract
This paper reports an implantable microsystem capable of recording neural activity simultaneously on 64 channels, wirelessly transmitting spike occurrences to an external interface. The microsystem also allows the user to examine the spike waveforms on any channel with 8 bit resolution. Signals are amplified by 60 dB with a programmable bandwidth fromrms. The channel scan rate for spike detection is 62.5 kS/sec using a 2 MHz clock. The system dissipates 14.4 mW at 1.8 V, weighs 275 mg, and measures 1.4 cm 1.55 cm.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Indeed, previous studies [53, 98, 128], which used either a symmetrical cascode OTA or a 2-stage Miller OTA, reported NEFs ranging from 4 to 17.”
From Implantable neurotechnologies: a review of integrated circuit neural amplifiers (2016) · cites this paper as [128]
Citations
Cites
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695
A low-power integrated circuit for a wireless 100-electrode neural recording system.
Harrison, R. R., Watkins, P. T., Kier, R. J., Lovejoy, R. O., Black, D. J., Greger, B., & Solzbacher, F. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2006.886567 · Cited by 782
A Low-Power Integrated Circuit for a Wireless 100-Electrode Neural Recording System
Harrison, R. R., Watkins, P., Kier, R. J., Lovejoy, R. O., Black, D., Normann, R. A., & Solzbacher, F. (2006) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2006.1696288 · Cited by 728
Wireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
Self-citationFlexible polyimide-based intracortical electrode arrays with bioactive capability
Rousche, P. J., Pellinen, D. S., Pivin, D. P., Williams, J. C., Vetter, R. J., & Kipke, D. R. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914800 · Cited by 644
Maynard, E. M., Nordhausen, C. T., & Normann, R. A. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(96)95176-0 · Cited by 640
Schwartz, A. B. (2004) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.27.070203.144233 · Cited by 560
Massively Parallel Recording of Unit and Local Field Potentials With Silicon-Based Electrodes
Csicsvari, J., Henze, D. A., Jamieson, B., Harris, K. D., Sirota, A., Barthó, P., Wise, K. D., & Buzsáki, G. (2003) · Journal of Neurophysiology · doi:10.1152/jn.00116.2003 · Cited by 402
Self-citationSpike Detection Using the Continuous Wavelet Transform
Nenadić, Z., & Burdick, J. W. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.839800 · Cited by 377
Reconstructing the Engram: Simultaneous, Multisite, Many Single Neuron Recordings
Nicolelis, M. A. L., Ghazanfar, A. A., Faggin, B. M., Votaw, S. V., & Oliveira, L. M. O. (1997) · Neuron · doi:10.1016/s0896-6273(00)80295-0 · Cited by 376
A glass/silicon composite intracortical electrode array
Jones, K. E., Campbell, P. K., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368134 · Cited by 354
An implantable multielectrode array with on-chip signal processing
Najafi, K., & Wise, K. D. (1986) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1986.1052646 · Cited by 310
Self-citationA high-yield IC-compatible multichannel recording array
Najafi, K., Wise, K. D., & Mochizuki, T. (1985) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1985.22102 · Cited by 303
Self-citationA Wideband Frequency-Shift Keying Wireless Link for Inductively Powered Biomedical Implants
Ghovanloo, M., & Najafi, K. (2004) · IEEE Transactions on Circuits and Systems I Fundamental Theory and Applications · doi:10.1109/tcsi.2004.838144 · Cited by 287
Self-citationWavelet preprocessing for automated neural network detection of EEG spikes
Kalayci, T., & Ozdamar, O. I. (1995) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.376754 · Cited by 264
A three-dimensional neural recording microsystem with implantable data compression circuitry
Olsson, R. H., & Wise, K. D. (2005) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2005.858479 · Cited by 245
Self-citationWireless multichannel biopotential recording using an integrated FM telemetry circuit
Mohseni, P., Najafi, K., Eliades, S. J., & Wang, X. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.853625 · Cited by 220
Self-citationA 32-site neural recording probe fabricated by DRIE of SOI substrates
Peter Norlin, A., Kindlundh, M., Mouroux, A., Yoshida, K., & Hofmann, U. (2002) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/12/4/312 · Cited by 184
Silicon ribbon cables for chronically implantable microelectrode arrays
Hetke, J. F., Lund, J. L., Najafi, K., Wise, K. D., & Anderson, D. J. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.284959 · Cited by 174
Self-citationA Fully Integrated Neural Recording Amplifier With DC Input Stabilization
Mohseni, P., & Najafi, K. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.824126 · Cited by 173
Self-citationAn implantable CMOS circuit interface for multiplexed microelectrode recording arrays
Ji, J., & Wise, K. D. (1992) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.121568 · Cited by 172
Self-citationInformation conveyed through brain-control: cursor versus robot
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814451 · Cited by 149
Digital integrated circuit design
(2000) · Choice Reviews Online · doi:10.5860/choice.37-4529 · Cited by 148
A Fully Integrated Mixed-Signal Neural Processor for Implantable Multichannel Cortical Recording
Sodagar, A. M., Wise, K. D., & Najafi, K. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.894986 · Cited by 133
Self-citationA Low-Temperature Thin-Film Electroplated Metal Vacuum Package
Stark, B. H., & Najafi, K. (2004) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2004.825301 · Cited by 103
Self-citationInterictal Spike Detection Using the Walsh Transform
Adjouadi, M., Sanchez, D., Cabrerizo, M., Ayala, M., Jayakar, P., Yaylali, I., & Barreto, A. B. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826642 · Cited by 95
A low-power CMOS neural amplifier with amplitude measurements for spike sorting
Horiuchi, T. K., Swindell, T., Sander, D., & Abshier, P. (2004) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2004.1328932 · Cited by 92
Chip-level vacuum packaging of micromachines using nanogetters
Sparks, D. R., Massoud-Ansari, S., & Najafi, N. (2003) · IEEE Transactions on Advanced Packaging · doi:10.1109/tadvp.2003.817964 · Cited by 90
Electronic apparatus for biological research
Shipton, H. W. (1959) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(59)90137-3 · Cited by 74
Nieder, A. (2000) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(00)00263-6 · Cited by 69
Takeuchi, S., & Shimoyama, I. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.820310 · Cited by 64
Implantable biomimetic microelectronic systems design
Liu, W., Sivaprakasam, M., Wang, G., Zhou, M., Granacki, J. J., LaCoss, J., & Wills, J. D. (2005) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2005.1511502 · Cited by 61
A fully-integrated bandpass amplifier for extracellular neural recording
Olsson, R. H., Gulari, A. N., & Wise, K. D. (2003) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2003.1196783 · Cited by 56
Self-citationA TinyOS-Enabled MICA2-Based Wireless Neural Interface
Farshchi, S., Nuyujukian, P., Pesterev, A. A., Módy, I., & Judy, J. W. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.873760 · Cited by 54
Fischer, H., Kautz, H., & Kutsch, W. (1996) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00083-6 · Cited by 47
A battery-powered 8-channel wireless FM IC for biopotential recording applications
Mohseni, P., & Najafi, K. (2005) · doi:10.1109/isscc.2005.1494118 · Cited by 45
Self-citationFully-Integrated CMOS Power Regulator for Telemetry-Powered Implantable Biomedical Microsystems
Sodagar, A. M., Najafi, K., Wise, K. D., & Ghovanloo, M. (2006) · Custom Integrated Circuits Conference · doi:10.1109/cicc.2006.320862 · Cited by 39
Self-citationPackaging of Implantable Microsystems
Najafi, K. (2007) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2007.4388335 · Cited by 39
Self-citationTransmission Latencies in a Telemetry-Linked Brain-Machine Interface
Bossetti, C. A., Carmena, J. M., Nicolelis, M. A. L., & Wolf, P. D. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827090 · Cited by 34
Perlin, G. E., Sodagar, A. M., & Wise, K. D. (2006) · 2006 International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2006.260193 · Cited by 30
Self-citationTranscutaneous RF-powered neural recording device
Irazoqui-Pastor, P., Módy, I., & Judy, J. W. (2002) · doi:10.1109/iembs.2002.1053190 · Cited by 30
An Implantable Microsystem for Wireless Multi-Channel Cortical Recording
Sodagar, A. M., Perlin, G. E., Yao, Y., Wise, K. D., & Najafi, K. (2007) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/sensor.2007.4300073 · Cited by 28
Self-citationAn EEG spike detection algorithm using artificial neural network with multi-channel correlation
Ko, C., Lin, Y., Chung, H., & Jan, G. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1998.747014 · Cited by 27
Manufacture of Metal Microelectrodes with the Scanning Electron Microscope
Skrzypek, J., & Keller, E. L. (1975) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1975.324519 · Cited by 25
Silicon Microelectrodes with Flexible Integrated Cables for Neural Implant Applications
Yao, Y., Gulari, M. N., Casey, B., Wiler, J. A., & Wise, K. D. (2007) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2007.369693 · Cited by 24
Self-citationFully integrated power supply design for wireless biomedical implants
Ghovanloo, M., & Najafi, K. (2003) · International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology (MMB) · doi:10.1109/mmb.2002.1002359 · Cited by 24
Self-citationLong-term testing of hermetic anodically bonded glass-silicon packages
Harpster, T. J., & Najafi, K. (2003) · doi:10.1109/memsys.2002.984293 · Cited by 22
Self-citationA WIRELESS MICROSYSTEM FOR MULTICHANNEL NEURAL RECORDING MICROPROBES
Yu, H., Olsson, R. H., Wise, K. D., & Najafi, K. (2004) · Solid-State Sensors, Actuators, and Microsystems Workshop (Hilton Head Workshop) · doi:10.31438/trf.hh2004.31 · Cited by 22
Self-citationThe bi-directional spike detection in EEG using mathematical morphology and wavelet transform
Pon, L.-S., Sun, M., & Sclabassi, R. J. (2003) · doi:10.1109/icosp.2002.1180082 · Cited by 18
An Implantable Multichannel Digital Neural Recording System For A Micromachined Sieve Electrode
Akın, T., Najafi, K., & Bradley, R. M. (2005) · Proceedings of the International Solid-State Sensors and Actuators Conference - TRANSDUCERS '95 · doi:10.1109/sensor.1995.717081 · Cited by 17
Self-citationMitchell, J. S., Lahiji, G. R., & Najafi, K. (2006) · Solid-State Sensors, Actuators, and Microsystems Workshop (Hilton Head Workshop) · doi:10.31438/trf.hh2006.96 · Cited by 16
Self-citationActive electrodes for EEG and evoked potential
Ko, W. H. (2002) · Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.1998.747053 · Cited by 15
Extremely-Wide-Range Supply-Independent CMOS Voltage References for Telemetry-Powering Applications
Sodagar, A. M., & Najafi, K. (2006) · Analog Integrated Circuits and Signal Processing · doi:10.1007/s10470-006-1644-3 · Cited by 15
Self-citationFlexible neural probes with micro-fluidic channels for stable interface with the nervous system
Suzuki, T., Ziegler, D., Mabuchi, K., & Takeuchi, S. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1404132 · Cited by 14
Action potential detection with automatic template matching
Kim, S., McNames, J., & Burchiel, K. J. (2005) · doi:10.1109/iembs.2004.1403085 · Cited by 12
Wireless multi-channel sensor for neurodynamic studies
Chestek, C. A., Samsukha, P., Tabib‐Azar, M., Harrison, R. R., Chiel, H. J., & Garverick, S. L. (2006) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2004.1426320 · Cited by 11
Enokawa, C., Yonezawa, Y., Maki, H., & Aritomo, M. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1997.758803 · Cited by 10
Chronic Neural Recording with a 64-Channel Cortical Microsystem
Sodagar, A. M., Perlin, G. E., Yao, Y., Najafi, K., & Wise, K. D. (2007) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2007.369694 · Cited by 6
Self-citationA computer-assisted spike detecting system using normalized method for epilepsy diagnosis
Oomori, Y., Yano, F., Ninomija, S. P., Kodama, H., Fujino, T., & Wada, J. A. (2003) · Hawaii International Conference on System Sciences (HICSS) · doi:10.1109/hicss.1988.11959 · Cited by 4
Research works printed but not linked: 2
- 0, See http //www fcc gov/oet/info/rules/part15/part15-9-20-07 pdf
- 10.1109/IEMBS.1997.758803 · DOI
Cited by
Sorted by citations
Wireless Power Transfer Strategies for Implantable Bioelectronics
Agarwal, K., Jegadeesan, R., Guo, Y., & Thakor, N. V. (2017) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2683520 · Cited by 549
Nanotools for Neuroscience and Brain Activity Mapping
Alivisatos, A. P., Andrews, A. M., Boyden, E. S., Chun, M., Church, G. M., Deisseroth, K. A., Donoghue, J. P., Fraser, S. E., Lippincott‐Schwartz, J., Looger, L. L., et al. (2013) · ACS Nano · doi:10.1021/nn4012847 · Cited by 359
Chronic, wireless recordings of large-scale brain activity in freely moving rhesus monkeys
Schwarz, D. A., Lebedev, M., Hanson, T., Dimitrov, D. F., Lehew, G., Meloy, J., Rajangam, S., Subramanian, V., Ifft, P. J., Li, Z., et al. (2014) · Nature Methods · doi:10.1038/nmeth.2936 · Cited by 348
Shon, A., Chu, J., Jung, J., Kim, H., & Youn, I. (2017) · Sensors · doi:10.3390/s18010001 · Cited by 320
EEG-Based Brain-Computer Interfaces: A Thorough Literature Survey
Hwang, H.-J., Kim, S., Choi, S., & Im, C.-H. (2013) · International Journal of Human-Computer Interaction · doi:10.1080/10447318.2013.780869 · Cited by 257
Metadata
- Authors
- Sodagar, A. M., Perlin, G. E., Yao, Y., Najafi, K., & Wise, K. D.
- Affiliations
- University of Michigan (US)
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2009-09
- Volume
- 44
- Issue
- 9
- Pages
- 2591-2604
- ISSN
- 0018-9200 (ISSN-L)
- OpenAlex
- W2144310300
- Cited by
- 218
- References
- 59
- Citations by year
- 2026: 4 · 2025: 3 · 2024: 1 · 2023: 10 · 2022: 8 · 2021: 6 · 2020: 4 · 2019: 18 · 2018: 15 · 2017: 15 · 2016: 16 · 2015: 17 · 2014: 23 · 2013: 26 · 2012: 17
- FWCI
- 10.21
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Journal of Solid-State Circuits (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Keywords
- implantable neural recording, single-unit recording, wireless data transmission, spike detection, low-power analog front-end
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review