The DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.
An Implantable 64-Channel Wireless Microsystem for Single-Unit Neural Recording
Abstract
This paper reports an implantable microsystem capable of recording neural activity simultaneously on 64 channels, wirelessly transmitting spike occurrences to an external interface. The microsystem also allows the user to examine the spike waveforms on any channel with 8 bit resolution. Signals are amplified by 60 dB with a programmable bandwidth fromrms. The channel scan rate for spike detection is 62.5 kS/sec using a 2 MHz clock. The system dissipates 14.4 mW at 1.8 V, weighs 275 mg, and measures 1.4 cm 1.55 cm.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Indeed, previous studies [53, 98, 128], which used either a symmetrical cascode OTA or a 2-stage Miller OTA, reported NEFs ranging from 4 to 17.”
From Implantable neurotechnologies: a review of integrated circuit neural amplifiers (2016) · cites this paper as [128]
Citations
Cites
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695
A low-power integrated circuit for a wireless 100-electrode neural recording system.
Harrison, R. R., Watkins, P. T., Kier, R. J., Lovejoy, R. O., Black, D. J., Greger, B., & Solzbacher, F. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2006.886567 · Cited by 782
A Low-Power Integrated Circuit for a Wireless 100-Electrode Neural Recording System
Harrison, R. R., Watkins, P., Kier, R. J., Lovejoy, R. O., Black, D., Normann, R. A., & Solzbacher, F. (2006) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2006.1696288 · Cited by 728
Wireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
Self-citationFlexible polyimide-based intracortical electrode arrays with bioactive capability
Rousche, P. J., Pellinen, D. S., Pivin, D. P., Williams, J. C., Vetter, R. J., & Kipke, D. R. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914800 · Cited by 644
Maynard, E. M., Nordhausen, C. T., & Normann, R. A. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(96)95176-0 · Cited by 640
Schwartz, A. B. (2004) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.27.070203.144233 · Cited by 560
Massively Parallel Recording of Unit and Local Field Potentials With Silicon-Based Electrodes
Csicsvari, J., Henze, D. A., Jamieson, B., Harris, K. D., Sirota, A., Barthó, P., Wise, K. D., & Buzsáki, G. (2003) · Journal of Neurophysiology · doi:10.1152/jn.00116.2003 · Cited by 402
Self-citationSpike Detection Using the Continuous Wavelet Transform
Nenadić, Z., & Burdick, J. W. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.839800 · Cited by 377
Reconstructing the Engram: Simultaneous, Multisite, Many Single Neuron Recordings
Nicolelis, M. A. L., Ghazanfar, A. A., Faggin, B. M., Votaw, S. V., & Oliveira, L. M. O. (1997) · Neuron · doi:10.1016/s0896-6273(00)80295-0 · Cited by 376
Research works printed but not linked: 2
- 0, See http //www fcc gov/oet/info/rules/part15/part15-9-20-07 pdf
- 10.1109/IEMBS.1997.758803 · DOI
Cited by
Sorted by citations
Wireless Power Transfer Strategies for Implantable Bioelectronics
Agarwal, K., Jegadeesan, R., Guo, Y., & Thakor, N. V. (2017) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2683520 · Cited by 549
Nanotools for Neuroscience and Brain Activity Mapping
Alivisatos, A. P., Andrews, A. M., Boyden, E. S., Chun, M., Church, G. M., Deisseroth, K. A., Donoghue, J. P., Fraser, S. E., Lippincott‐Schwartz, J., Looger, L. L., et al. (2013) · ACS Nano · doi:10.1021/nn4012847 · Cited by 359
Chronic, wireless recordings of large-scale brain activity in freely moving rhesus monkeys
Schwarz, D. A., Lebedev, M., Hanson, T., Dimitrov, D. F., Lehew, G., Meloy, J., Rajangam, S., Subramanian, V., Ifft, P. J., Li, Z., et al. (2014) · Nature Methods · doi:10.1038/nmeth.2936 · Cited by 348
Shon, A., Chu, J., Jung, J., Kim, H., & Youn, I. (2017) · Sensors · doi:10.3390/s18010001 · Cited by 320
EEG-Based Brain-Computer Interfaces: A Thorough Literature Survey
Hwang, H.-J., Kim, S., Choi, S., & Im, C.-H. (2013) · International Journal of Human-Computer Interaction · doi:10.1080/10447318.2013.780869 · Cited by 257
Lee, S. B., Lee, H.-M., Kiani, M., Jow, U.-M., & Ghovanloo, M. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2078814 · Cited by 220
State-of-the-art MEMS and microsystem tools for brain research
Seymour, J. P., Wu, F., Wise, K. D., & Yoon, E. (2017) · Microsystems & Nanoengineering · doi:10.1038/micronano.2016.66 · Cited by 221
Self-citationA Fully-Integrated, Miniaturized (0.125 mm²) 10.5 µW Wireless Neural Sensor
Biederman, W., Yeager, D. J., Narevsky, N., Koralek, A. C., Carmena, J. M., Alon, E., & Rabaey, J. M. (2013) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2238994 · Cited by 167
A 100-Channel Hermetically Sealed Implantable Device for Chronic Wireless Neurosensing Applications
Yin, M., Borton, D. A., Aceros, J. C., Patterson, W. R., & Nurmikko, A. V. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2255874 · Cited by 161
Azin, M., Guggenmos, D. J., Barbay, S., Nudo, R. J., & Mohseni, P. (2011) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2108770 · Cited by 168
3D Parylene sheath neural probe for chronic recordings
Kim, B. J., Kuo, J. T. W., Hara, S. A., Lee, C. D., Liu, Y., Gutierrez, C. A., Hoang, T., Pikov, V., & Meng, E. F. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/4/045002 · Cited by 159
Wireless Power and Data Transmission for Implanted Devices via Inductive Links: A Systematic Review
Karimi, M., Schmid, A., & Dehollain, C. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3049918 · Cited by 110
A 75-µW, 16-Channel Neural Spike-Sorting Processor With Unsupervised Clustering
Karkare, V., Gibson, S., & Markovic, D. M. (2013) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2264616 · Cited by 130
Lee, B., Koripalli, M. K., Jia, Y., Acosta, J., Sendi, M. S. E., Choi, Y., & Ghovanloo, M. (2018) · Scientific Reports · doi:10.1038/s41598-018-24465-1 · Cited by 122
The Microbead: A 0.009 mm 3 Implantable Wireless Neural Stimulator
Khalifa, A., Liu, Y., Karimi, Y., Wang, Q., Eisape, A. A., Stanaćević, M., Thakor, N. V., Bao, Z., & Etienne‐Cummings, R. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2939014 · Cited by 121
Rodriguez-Perez, A., Ruiz-Amaya, J., Delgado-Restituto, M., & Rodriguez-Vazquez, Á. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2187352 · Cited by 103
Analysis and Design of Tunable Amplifiers for Implantable Neural Recording Applications
Rezaee-Dehsorkh, H., Ravanshad, N., Lotfi, R., Mafinezhad, K., & Sodagar, A. M. (2011) · IEEE Journal on Emerging and Selected Topics in Circuits and Systems · doi:10.1109/jetcas.2011.2174492 · Cited by 103
Self-citationLin, Y.-P., Yeh, C.-Y., Huang, P.-Y., Wang, Z.-Y., Cheng, H.-H., Li, Y., Chuang, C.-F., Huang, P.-C., Tang, K., Ma, H., et al. (2015) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2015.2403282 · Cited by 100
Kiani, M., & Ghovanloo, M. (2014) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2304956 · Cited by 99
Analog Integrated Circuits Design for Processing Physiological Signals
Li, Y., Poon, C. C. Y., & Zhang, Y. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2082521 · Cited by 100
A Fully Reconfigurable Low-Noise Biopotential Sensing Amplifier With 1.96 Noise Efficiency Factor
Wang, T.-Y., Lai, M.-R., Twigg, C. M., & Peng, S.-Y. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2278659 · Cited by 97
Park, S., Cho, J., Na, K., & Yoon, E. (2017) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2017.2764053 · Cited by 94
Enabling Wireless Powering and Telemetry for Peripheral Nerve Implants
Jegadeesan, R., Nag, S., Agarwal, K., Thakor, N., & Guo, Y.-X. (2015) · IEEE journal of biomedical and health informatics · doi:10.1109/jbhi.2015.2424985 · Cited by 81
A Power and Data Link for a Wireless-Implanted Neural Recording System
Rush, A. D., & Troyk, P. R. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2214385 · Cited by 90
A Wireless Implantable Microsystem for Multichannel Neural Recording
Sodagar, A. M., Wise, K. D., & Najafi, K. (2009) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2009.2029957 · Cited by 90
Self-citationApplications of Microwaves in Medicine
Chiao, J. ‐., Li, C., Lin, J., Caverly, R. H., Hwang, J. C. M., Rosen, H. D., & Rosen, A. (2022) · IEEE Journal of Microwaves · doi:10.1109/jmw.2022.3223301 · Cited by 94
An Inductively-Powered Wireless Neural Recording and Stimulation System for Freely-Behaving Animals
Lee, B., Jia, Y., Mirbozorgi, S. A., Connolly, M. J., Tong, X., Zeng, Z., Mahmoudi, B., & Ghovanloo, M. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2891303 · Cited by 92
Rothschild, R. M. (2010) · Frontiers in Neuroengineering · doi:10.3389/fneng.2010.00112 · Cited by 86
Silicon-Integrated High-Density Electrocortical Interfaces
Ha, S., Akinin, A., Park, J., Kim, C., Wang, H., Maier, C., Mercier, P. P., & Cauwenberghs, G. (2016) · Proceedings of the IEEE · doi:10.1109/jproc.2016.2587690 · Cited by 84
Implantable neurotechnologies: a review of integrated circuit neural amplifiers
Ng, K. A., Greenwald, E., Xu, Y. P., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1431-3 · Cited by 83
Ha, S., Kim, C., Park, J., Joshi, S., & Cauwenberghs, G. (2016) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2016.2600864 · Cited by 77
The Microbead: A Highly Miniaturized Wirelessly Powered Implantable Neural Stimulating System
Khalifa, A., Karimi, Y., Wang, Q., Montlouis, W., Garikapati, S., Stanaćević, M., Thakor, N. V., & Etienne‐Cummings, R. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2802443 · Cited by 77
Seidl, K., Herwik, S., Torfs, T., Neves, H. P., Paul, O., & Ruther, P. (2011) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2011.2167661 · Cited by 68
Multi-Channel Neural Recording Implants: A Review
Hashemi Noshahr, F., Nabavi, M., & Sawan, M. (2020) · Sensors · doi:10.3390/s20030904 · Cited by 66
A 10.2 Mbps Pulse Harmonic Modulation Based Transceiver for Implantable Medical Devices
Inanlou, F., Kiani, M., & Ghovanloo, M. (2011) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2134570 · Cited by 65
Three-Phase Time-Multiplexed Planar Power Transmission to Distributed Implants
Lee, B., Ahn, D., & Ghovanloo, M. (2015) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2015.2436391 · Cited by 64
Syringe-injectable electronics with a plug-and-play input/output interface.
Schuhmann, T. G., Yao, J., Hong, G., Fu, T.-M., & Lieber, C. M. (2017) · Nano Letters · doi:10.1021/acs.nanolett.7b03081 · Cited by 63
EnerCage: A Smart Experimental Arena With Scalable Architecture for Behavioral Experiments
Jow, U.-M., McMenamin, P., Kiani, M., Manns, J. R., & Ghovanloo, M. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2278180 · Cited by 62
A high-density carbon fiber neural recording array technology
Massey, T. L., Santacruz, S. R., Hou, J. F., Pister, K. S. J., Carmena, J. M., & Maharbiz, M. M. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/aae8d9 · Cited by 58
An Implantable Pressure Sensing System With Electromechanical Interrogation Scheme
Kim, A., Powell, C., & Ziaie, B. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2318023 · Cited by 53
Neural Probes for Chronic Applications
Kook, G., Lee, S., Lee, H., Cho, I., & Lee, H. J. (2016) · Micromachines · doi:10.3390/mi7100179 · Cited by 61
Wideband Near-Field Data Transmission Using Pulse Harmonic Modulation
Inanlou, F., & Ghovanloo, M. (2010) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2010.2055351 · Cited by 51
Do, A. T., Zeinolabedin, S. M. A., Jeon, D., Sylvester, D., & Kim, T. T.-H. (2018) · IEEE Transactions on Very Large Scale Integration (VLSI) Systems · doi:10.1109/tvlsi.2018.2875934 · Cited by 51
Data Compression in Brain-Machine/Computer Interfaces Based on the Walsh–Hadamard Transform
Hosseini‐Nejad, H., Jannesari, A., & Sodagar, A. M. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2258669 · Cited by 49
Self-citationA Survey of Neural Front End Amplifiers and Their Requirements toward Practical Neural Interfaces
Bharucha, E. A., Sepehrian, H., & Gosselin, B. J. (2014) · Journal of Low Power Electronics and Applications · doi:10.3390/jlpea4040268 · Cited by 49
A Sub-${\mu}$W/Ch Analog Front-End for $\Delta $-Neural Recording With Spike-Driven Data Compression
Kim, S., Han, S.-H., Cha, J.-H., Liu, L., Yao, L., Gao, Y., & Je, M. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2880257 · Cited by 49
A Smart Wirelessly Powered Homecage for Long-Term High-Throughput Behavioral Experiments
Lee, B., Kiani, M., & Ghovanloo, M. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2015.2430859 · Cited by 48
Massot, B., Arthaud, S., Barrillot, B., Roux, J., Ungurean, G., Luppi, P., Rattenborg, N. C., & Libourel, P. (2018) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2018.08.030 · Cited by 43
Physiological properties of brain-machine interface input signals
Slutzky, M. W., & Flint, R. D. (2017) · Journal of Neurophysiology · doi:10.1152/jn.00070.2017 · Cited by 47
Bioelectronic Sensor Nodes for the Internet of Bodies
Chatterjee, B., Mohseni, P., & Sen, S. (2023) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-110220-112448 · Cited by 48
Meng, X., Browne, K., Huang, S.-M., Mietus, C., Cullen, D. K., Tofighi, M., & Rosen, A. (2013) · IEEE transactions on microwave theory and techniques · doi:10.1109/tmtt.2012.2224361 · Cited by 44
Shaeri, M., & Sodagar, A. M. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2355139 · Cited by 44
Self-citationTowards a Smart Experimental Arena for Long-Term Electrophysiology Experiments
Jow, U.-M., Kiani, M., Huo, X., & Ghovanloo, M. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2211872 · Cited by 41
A Frequency Shaping Neural Recorder With 3 pF Input Capacitance and 11 Plus 4.5 Bits Dynamic Range
Xu, J., Wu, T., Liu, W., & Yang, Z. (2014) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2293821 · Cited by 41
Enabling Low-Power, Multi-Modal Neural Interfaces Through a Common, Low-Bandwidth Feature Space
Irwin, Z. T., Thompson, D. E., Schroeder, K. E., Tat, D. M., Hassani, A., Bullard, A. J., Woo, S. L., Urbanchek, M. G., Sachs, A. J., Cederna, P. S., et al. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2501752 · Cited by 43
Yeon, P., Mirbozorgi, S. A., Ash, B., Eckhardt, H., & Ghovanloo, M. (2016) · Micromachines · doi:10.3390/mi7090154 · Cited by 40
A Multicycle Q-Modulation for Dynamic Optimization of Inductive Links
Lee, B., Yeon, P., & Ghovanloo, M. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2550009 · Cited by 38
Nonlinear Signal-Specific ADC for Efficient Neural Recording in Brain-Machine Interfaces
Judy, M., Sodagar, A. M., Lotfi, R., & Sawan, M. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2270178 · Cited by 35
Self-citationThe injectable neurostimulator: an emerging therapeutic device
Li, X., Serdijn, W. A., Zheng, W., Tian, Y., & Zhang, B. (2015) · Trends in biotechnology · doi:10.1016/j.tibtech.2015.04.001 · Cited by 35
Design considerations for effective neural signal sensing and amplification: a review
Sharma, K., & Sharma, R. (2019) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/ab1674 · Cited by 33
A Tunable Biquad Switched-Capacitor Amplifier-Filter for Neural Recording
Lee, J., Johnson, M. D., & Kipke, D. R. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2066272 · Cited by 30
System-Level Design of a 64-Channel Low Power Neural Spike Recording Sensor
Delgado‐Restituto, M., Rodríguez‐Pérez, A., Darie, A., Soto‐Sánchez, C., Fernandez-Jover, E., & Rodriguez-Vazquez, A. (2017) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2016.2618319 · Cited by 30
Syringe-injectable Mesh Electronics for Stable Chronic Rodent Electrophysiology
Schuhmann, T. G., Zhou, T., Hong, G., Lee, J. M., Tian-ming Fu, B., Park, H., & Lieber, C. M. (2018) · Journal of Visualized Experiments · doi:10.3791/58003 · Cited by 30
An 8-to-1 bit 1-MS/s SAR ADC With VGA and Integrated Data Compression for Neural Recording
Chaturvedi, V., Anand, T., & Amrutur, B. S. (2013) · IEEE Transactions on Very Large Scale Integration (VLSI) Systems · doi:10.1109/tvlsi.2013.2238957 · Cited by 27
Advances in Microelectronics for Implantable Medical Devices
Demosthenous, A. (2014) · Advances in Electronics · doi:10.1155/2014/981295 · Cited by 29
Yin, M., & Ghovanloo, M. (2010) · Analog Integrated Circuits and Signal Processing · doi:10.1007/s10470-010-9557-6 · Cited by 27
Rodríguez‐Pérez, A., Delgado‐Restituto, M., & Medeiro, F. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2270180 · Cited by 27
Energy Harvesting and Power Delivery for Implantable Medical Devices
Tsui, C.-Y., Li, X., & Ki, W. (2013) · Foundations and Trends® in Electronic Design Automation · doi:10.1561/1000000029 · Cited by 26
A PVT insensitive programmable amplifier for biomedical applications
Nagulapalli, R., Hayatleh, K., Barker, S., Zourob, S., Yassine, N., & Sridevi, S. (2017) · International Conference on Microelectronic Devices, Circuits and Systems (ICMDCS) · doi:10.1109/icmdcs.2017.8211724 · Cited by 26
Algorithm and hardware considerations for real-time neural signal on-implant processing
Zhang, Z., Savolainen, O. W., & Constandinou, T. G. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac5268 · Cited by 25
Bonfanti, A. G., Ceravolo, M., Zambra, G., Gusmeroli, R., Spinelli, A. S., Lacaita, A. L., Angotzi, G. N., Baranauskas, G., & Fadiga, L. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5626696 · Cited by 24
Liu, S., Moncion, C., Zhang, J., Balachandar, L., Kwaku, D., Riera, J. J., Volakis, J. L., & Chae, J. (2019) · ACS Sensors · doi:10.1021/acssensors.9b01491 · Cited by 24
Parylene microprobes with engineered stiffness and shape for improved insertion
Egert, D., Peterson, R. L., & Najafi, K. (2011) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/transducers.2011.5969352 · Cited by 24
Self-citationA Low Noise Amplifier for Neural Spike Recording Interfaces
Ruiz-Amaya, J., Rodriguez-Perez, A., & Delgado-Restituto, M. (2015) · Sensors · doi:10.3390/s151025313 · Cited by 23
Zhang, F., Aghagolzadeh, M., & Oweiss, K. G. (2012) · Journal of Signal Processing Systems · doi:10.1007/s11265-012-0670-x · Cited by 23
Current Challenges to the Clinical Translation of Brain Machine Interface Technology
Lu, C. W., Patil, P. G., & Chestek, C. A. (2012) · International review of neurobiology · doi:10.1016/b978-0-12-404706-8.00008-5 · Cited by 24
Wireless Telemetry for Implantable Biomedical Microsystems
Asgarian, F., & Amir, M. (2011) · InTech eBooks · doi:10.5772/12997 · Cited by 22
Optimal design of a 3-coil inductive link for millimeter-sized biomedical implants
Yeon, P., Mirbozorgi, S. A., & Ghovanloo, M. (2016) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2016.7833815 · Cited by 21
A compact, low-power, fully analog implantable microstimulator
Khalifa, A., Zhang, J. J., Leistner, M., & Etienne‐Cummings, R. (2016) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2016.7539084 · Cited by 20
Chow, J. P.-W., Chung, H. S.-H., Chan, L. L.-H., Shen, R., & Tang, S. C. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2894182 · Cited by 20
Shaeri, M., & Sodagar, A. M. (2022) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2022.3151340 · Cited by 18
Self-citationYin, M., Li, H., Bull, C. W., Borton, D. A., Aceros, J. C., Larson, L. E., & Nurmikko, A. V. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6610199 · Cited by 18
A 23 µA RF-powered transmitter for biomedical applications
Zhang, F., Stoneback, M., & Otis, B. P. (2011) · Digest of papers - IEEE Radio Frequency Integrated Circuits Symposium · doi:10.1109/rfic.2011.5940711 · Cited by 19
Wireless, miniaturized, semi-implantable electrocorticography microsystem validated in vivo
Keramatzadeh, K., Kiakojouri, A., Nahvi, M. S., Khazaei, Y., Feizi-nejad, A., Maghami, M. H., Mohammadi, R., Sharifshazileh, M., Nasiri, S., Boroumand, F. A., et al. (2020) · Scientific Reports · doi:10.1038/s41598-020-77953-8 · Cited by 17
Self-citationA high-performance transcutaneous battery charger for medical implants
Artan, N. S., Vanjani, H., Vashist, G., Fu, Z., Bhakthavatsala, S., Ludvig, N., Medveczky, G., & Chao, H. J. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5626683 · Cited by 16
Zhang, J. X. J., & Hoshino, K. (2013) · Elsevier eBooks · doi:10.1016/b978-1-4557-7631-3.00007-7 · Cited by 15
Wireless neural probes based on one-port SAW delay line and neural firing-dependent varicap diode
Jung, I., & Lee, K. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.10.070 · Cited by 15
Chang, C., Chou, L.-C., Huang, P.-T., Wu, S.-L., Lee, S.-W., Chuang, C.-T. K., Chen, K., Hwang, W., Chen, K.-H., Chiu, C.-T., et al. (2015) · Biomedical Microdevices · doi:10.1007/s10544-014-9906-9 · Cited by 14
Egert, D., & Najafi, K. (2011) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/transducers.2011.5969351 · Cited by 14
Self-citationAn adaptive continuous‐time incremental Σ∆ ADC for neural recording implants
Barati, S., & Yavari, M. (2018) · International Journal of Circuit Theory and Applications · doi:10.1002/cta.2585 · Cited by 14
Chang, C., & Chen, W.-H. (2019) · IEEE Transactions on Very Large Scale Integration (VLSI) Systems · doi:10.1109/tvlsi.2019.2940035 · Cited by 14
Active Pixel Sensor Multielectrode Array for High Spatiotemporal Resolution
Berdondini, L., Bosca, A., Nieus, T. R., & Maccione, A. (2014) · Springer eBooks · doi:10.1007/978-1-4899-8038-0_7 · Cited by 14
A Time-Domain Analog Spatial Compressed Sensing Encoder for Multi-Channel Neural Recording
Okazawa, T., & Akita, I. (2018) · Sensors · doi:10.3390/s18010184 · Cited by 14
Non-human primate models and systems for gait and neurophysiological analysis
Liang, F., Yu, S., Pang, S., Wang, X., Jie, J., Gao, F., Song, Z., Li, B., Liao, W., & Yin, M. (2023) · Frontiers in Neuroscience · doi:10.3389/fnins.2023.1141567 · Cited by 13
Short-Range Quality-Factor Modulation (SQuirM) for Low Power High Speed Inductive Data Transfer
Schormans, M., Jiang, D., Valente, V., & Demosthenous, A. (2019) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2019.2922124 · Cited by 13
A comparative study of low-noise amplifiers for neural applications
Ruiz‐Amaya, J., Rodríguez‐Pérez, A., & Delgado‐Restituto, M. (2010) · doi:10.1109/icm.2010.5696151 · Cited by 13
Auxiliary-carrier load-shift keying for reverse data telemetry from biomedical implants
Karimi, M., Sodagar, A. M., Mofrad, M. E., & Amiri, P. (2012) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2012.6418457 · Cited by 12
Self-citationOn the use of compressive sensing (CS) exploiting block sparsity for neural spike recording
Zamani, H. A., Bahrami, H. R., & Mohseni, P. (2016) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2016.7833773 · Cited by 12
Low Noise Amplifier in Smart Healthcare Applications
Bansal, M., & Jyoti (2019) · International Conference on Signal Processing and Integrated Networks (SPIN) · doi:10.1109/spin.2019.8711705 · Cited by 12
Self-Biased Ultralow Power Current-Reused Neural Amplifier With On-Chip Analog Spike Detections
Kim, J., & Ko, H. (2019) · IEEE Access · doi:10.1109/access.2019.2933674 · Cited by 12
Metadata
- Authors
- Sodagar, A. M., Perlin, G. E., Yao, Y., Najafi, K., & Wise, K. D.
- Affiliations
- University of Michigan (US)
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2009-09
- Volume
- 44
- Issue
- 9
- Pages
- 2591-2604
- ISSN
- 0018-9200 (ISSN-L)
- OpenAlex
- W2144310300
- Cited by
- 218
- References
- 59
- Citations by year
- 2026: 4 · 2025: 3 · 2024: 1 · 2023: 10 · 2022: 8 · 2021: 6 · 2020: 4 · 2019: 18 · 2018: 15 · 2017: 15 · 2016: 16 · 2015: 17 · 2014: 23 · 2013: 26 · 2012: 17
- FWCI
- 10.21
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Journal of Solid-State Circuits (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Keywords
- implantable neural recording, single-unit recording, wireless data transmission, spike detection, low-power analog front-end
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review