The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
A Micro-Power EEG Acquisition SoC With Integrated Feature Extraction Processor for a Chronic Seizure Detection System
Open accessAbstract
This paper presents a low-power SoC that performs EEG acquisition and feature extraction required for continuous detection of seizure onset in epilepsy patients. The SoC corresponds to one EEG channel, and, depending on the patient, up to 18 channels may be worn to detect seizures as part of a chronic treatment system. The SoC integrates an instrumentation amplifier, ADC, and digital processor that streams features-vectors to a central device where seizure detection is performed via a machine-learning classifier. The instrumentation-amplifier uses chopper-stabilization in a topology that achieves high input-impedance and rejects large electrode-offsets while operating at 1 V; the ADC employs power-gating for low energy-per-conversion while using static-biasing for comparator precision; the EEG feature extraction processor employs low-power hardware whose parameters are determined through validation via patient data. The integration of sensing and local processing lowers system power by 14× by reducing the rate of wireless EEG data transmission. Feature vectors are derived at a rate of 0.5 Hz, and the complete one-channel SoC operates from a 1 V supply, consuming 9 ¿ J per feature vector.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Introduction to Support Vector Machines and Other Kernel-based Learning Methods
Cristianini, N., & Shawe-Taylor, J. (2000) · doi:10.1017/cbo9780511801389 · Cited by 13,855
Discrete-Time Signal Processing
Oppenheim, A. V., & Schafer, R. W. (1989) · Cited by 12,572
Discrete-time Signal Processing
Williamson, D. (1999) · Advanced Textbooks in Control and Signal Processing · doi:10.1007/978-1-4471-0541-1 · Cited by 4,858
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695
Denison, T., Consoer, K., Santa, W., Avestruz, A.-T., Cooley, J., & Kelly, A. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2007.908664 · Cited by 451
An Energy-Efficient Micropower Neural Recording Amplifier
Wattanapanitch, W., Fee, M., & Sarpeshkar, R. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.907868 · Cited by 441
Is Resting Anterior EEG Alpha Asymmetry a Trait Marker for Depression?
Debener, S., Beauducel, A., Nessler, D., Brocke, B., Heilemann, H., & Kayser, J. (2000) · Neuropsychobiology · doi:10.1159/000026630 · Cited by 358
An Ultra Low Energy 12-bit Rate-Resolution Scalable SAR ADC for Wireless Sensor Nodes
Verma, N., & Chandrakasan, A. P. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2007.897157 · Cited by 326
Self-citationBohorquez, J. L., Chandrakasan, A. P., & Dawson, J. L. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2014728 · Cited by 246
Self-citationDeep Brain Stimulation for Epilepsy
Halpern, C. H., Samadani, U., Litt, B., Jaggi, J. L., & Baltuch, G. H. (2008) · Neurotherapeutics · doi:10.1016/j.nurt.2007.10.065 · Cited by 151
A 47pJ/pulse 3.1-to-5GHz All-Digital UWB Transmitter in 90nm CMOS
Wentzloff, D. D., & Chandrakasan, A. P. (2007) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2007.373616 · Cited by 148
Self-citationA 5 $\mu$W/Channel Spectral Analysis IC for Chronic Bidirectional Brain–Machine Interfaces
Avestruz, A.-T., Santa, W. A., Carlson, D., Jensen, R. M., Stanslaski, S. R., Helfenstine, A., & Denison, T. (2008) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2008.2006460 · Cited by 142
Kamousi, B., Liu, Z., & He, B. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.847386 · Cited by 140
Shoeb, A. H., Pang, T. D., Guttag, J. V., & Schachter, S. C. (2009) · International Journal of Neural Systems · doi:10.1142/s0129065709001938 · Cited by 88
Self-citationShoeb, A. H., Carlson, D., Panken, E., & Denison, T. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333790 · Cited by 62
Self-citationVerma, N., Shoeb, A. H., Guttag, J. V., & Chandrakasan, A. P. (2009) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 48
Self-citationDynamics of slow wave activity in narcoleptic patients under bed rest conditions
Nobili, L., Besset, A., Ferrillo, F., Rosadini, G., Schiavi, G., & Billiard, M. M. (1995) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(95)00138-7 · Cited by 43
Impact of Patient-Specificity on Seizure Onset Detection Performance
Shoeb, A. H., Bourgeois, B. F. D., Treves, S. T., Schachter, S. C., & Guttag, J. V. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353240 · Cited by 22
Self-citation
Cited by
Dry-Contact and Noncontact Biopotential Electrodes: Methodological Review
Chi, Y. M., Jung, T.-P., & Cauwenberghs, G. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2084078 · Cited by 1,061
Fan, Q., Sebastiano, F., Huijsing, J. H., & Makinwa, K. A. A. (2011) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2143610 · Cited by 473
Chen, F., Chandrakasan, A. P., & Stojanovic, V. M. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2179451 · Cited by 376
Self-citationA Minimally Invasive 64-Channel Wireless μECoG Implant
Muller, R., Le, H.-P., Li, W., Ledochowitsch, P., Gambini, S., Bjorninen, T., Koralek, A., Carmena, J. M., Maharbiz, M. M., Alon, E., et al. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2364824 · Cited by 372
A Batteryless 19 $\mu$W MICS/ISM-Band Energy Harvesting Body Sensor Node SoC for ExG Applications
Zhang, Y., Zhang, F., Shakhsheer, Y., Silver, J. D., Klinefelter, A., Nagaraju, M., Boley, J., Pandey, J., Shrivastava, A., Carlson, E. J., et al. (2013) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2012.2221217 · Cited by 326
Metadata
- Authors
- Verma, N., Shoeb, A., Bohorquez, J., Dawson, J., Guttag, J., & Chandrakasan, A. P.
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2010-04
- Volume
- 45
- Issue
- 4
- Pages
- 804-816
- ISSN
- 0018-9200 (ISSN-L)
- 1558-173X
- OpenAlex
- W2169766445
- Cited by
- 526
- References
- 18
- FWCI
- 24.76
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.