A Micro-Power EEG Acquisition SoC With Integrated Feature Extraction Processor for a Chronic Seizure Detection System
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
This paper presents a low-power SoC that performs EEG acquisition and feature extraction required for continuous detection of seizure onset in epilepsy patients. The SoC corresponds to one EEG channel, and, depending on the patient, up to 18 channels may be worn to detect seizures as part of a chronic treatment system. The SoC integrates an instrumentation amplifier, ADC, and digital processor that streams features-vectors to a central device where seizure detection is performed via a machine-learning classifier. The instrumentation-amplifier uses chopper-stabilization in a topology that achieves high input-impedance and rejects large electrode-offsets while operating at 1 V; the ADC employs power-gating for low energy-per-conversion while using static-biasing for comparator precision; the EEG feature extraction processor employs low-power hardware whose parameters are determined through validation via patient data. The integration of sensing and local processing lowers system power by 14× by reducing the rate of wireless EEG data transmission. Feature vectors are derived at a rate of 0.5 Hz, and the complete one-channel SoC operates from a 1 V supply, consuming 9 ¿ J per feature vector.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Introduction to Support Vector Machines and Other Kernel-based Learning Methods
Cristianini, N., & Shawe-Taylor, J. (2000) · doi:10.1017/cbo9780511801389 · Cited by 13,855
Discrete-Time Signal Processing
Oppenheim, A. V., & Schafer, R. W. (1989) · Cited by 12,663
Discrete-time Signal Processing
Williamson, D. (1999) · Advanced Textbooks in Control and Signal Processing · doi:10.1007/978-1-4471-0541-1 · Cited by 4,858
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695
Denison, T., Consoer, K., Santa, W., Avestruz, A.-T., Cooley, J., & Kelly, A. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2007.908664 · Cited by 451
An Energy-Efficient Micropower Neural Recording Amplifier
Wattanapanitch, W., Fee, M., & Sarpeshkar, R. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.907868 · Cited by 441 · cited 1×
“Finally, alternate topologies that do not rely on chopper stabilization have also been effective for bio-sensing applications [18], [19].”
BackgroundIs Resting Anterior EEG Alpha Asymmetry a Trait Marker for Depression?
Debener, S., Beauducel, A., Nessler, D., Brocke, B., Heilemann, H., & Kayser, J. (2000) · Neuropsychobiology · doi:10.1159/000026630 · Cited by 358
An Ultra Low Energy 12-bit Rate-Resolution Scalable SAR ADC for Wireless Sensor Nodes
Verma, N., & Chandrakasan, A. P. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2007.897157 · Cited by 326
Self-citationBohorquez, J. L., Chandrakasan, A. P., & Dawson, J. L. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2014728 · Cited by 246
Self-citationDeep Brain Stimulation for Epilepsy
Halpern, C. H., Samadani, U., Litt, B., Jaggi, J. L., & Baltuch, G. H. (2008) · Neurotherapeutics · doi:10.1016/j.nurt.2007.10.065 · Cited by 151
Cited by
Dry-Contact and Noncontact Biopotential Electrodes: Methodological Review
Chi, Y. M., Jung, T.-P., & Cauwenberghs, G. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2084078 · Cited by 1,061
Fan, Q., Sebastiano, F., Huijsing, J. H., & Makinwa, K. A. A. (2011) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2143610 · Cited by 473
Chen, F., Chandrakasan, A. P., & Stojanovic, V. M. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2179451 · Cited by 376
Self-citationA Minimally Invasive 64-Channel Wireless μECoG Implant
Muller, R., Le, H.-P., Li, W., Ledochowitsch, P., Gambini, S., Bjorninen, T., Koralek, A., Carmena, J. M., Maharbiz, M. M., Alon, E., et al. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2364824 · Cited by 372
A Batteryless 19 $\mu$W MICS/ISM-Band Energy Harvesting Body Sensor Node SoC for ExG Applications
Zhang, Y., Zhang, F., Shakhsheer, Y., Silver, J. D., Klinefelter, A., Nagaraju, M., Boley, J., Pandey, J., Shrivastava, A., Carlson, E. J., et al. (2013) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2012.2221217 · Cited by 326
RF power harvesting: a review on designing methodologies and applications
Tran, L.-G., Cha, H.-K., & Park, W.-T. (2017) · Micro and Nano Systems Letters · doi:10.1186/s40486-017-0051-0 · Cited by 293
Chen, W.-M., Chiueh, H., Chen, T.-J., Ho, C.-L., Jeng, C., Ker, M.-D., Lin, C.-Y., Huang, Y.-C., Chou, C.-W., Fan, T.-Y., et al. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2284346 · Cited by 279
Yoo, J., Yan, L., El-Damak, D., Altaf, M. A. B., Shoeb, A. H., & Chandrakasan, A. P. (2013) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2012.2221220 · Cited by 274
Self-citationA 30 $\mu$W Analog Signal Processor ASIC for Portable Biopotential Signal Monitoring
Yazicioglu, R. F., Kim, S., Torfs, T., Kim, H., & Van Hoof, C. (2011) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2085930 · Cited by 263
Advances in closed-loop deep brain stimulation devices
Parastarfeizabadi, M., & Kouzani, A. Z. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0295-1 · Cited by 232
A Configurable and Low-Power Mixed Signal SoC for Portable ECG Monitoring Applications
Kim, H., Kim, S., Van Helleputte, N., Artes, A., Konijnenburg, M., Huisken, J., Van Hoof, C., & Yazicioglu, R. F. (2014) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2260159 · Cited by 230
“The main benefit of this type of IAs is that the CMRR doesn’t rely on matching of passives [5, 6] and is able to provide a CMRR in excess of 100dB.”
BackgroundBin Altaf, M. A., Zhang, C., & Yoo, J. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2015.2482498 · Cited by 192
“Multichannel electroencephalogram (EEG) seizure detection SoCs are widely adopted in medical practice and in research [7], [18], but these have following limitations.”
BackgroundCompressed Sensing Analog Front-End for Bio-Sensor Applications
Gangopadhyay, D., Allstot, E. G., Dixon, A. M. R., Natarajan, K., Gupta, S., & Allstot, D. J. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2284673 · Cited by 175
Impedance and Noise of Passive and Active Dry EEG Electrodes: A Review
Habibzadeh Tonekabony Shad, E., Molinas, M., & Ytterdal, T. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3012394 · Cited by 173
“It has been productively used in epilepsy, Parkinson’s disease, narcolepsy, depression, motor impairment, sports, entertainment, and computer-related functions [8]–[16].”
MethodA Micropower Low-Noise Neural Recording Front-End Circuit for Epileptic Seizure Detection
Qian, C., Parramon, J., & Sanchez-Sinencio, E. (2011) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2126370 · Cited by 145
Recent Advances in Neural Recording Microsystems
Gosselin, B. (2011) · Sensors · doi:10.3390/s110504572 · Cited by 138
“In addition to that, some designs are employing active approaches like Chopper stabilization to attenuate 1/f noise [50,51], which is dominant in the low-frequency range (between 1 mHz and a few hundred Hz) for CMOS integrated devices.”
MethodAbdelhalim, K., Jafari, H. M., Kokarovtseva, L., Velazquez, J. L. P., & Genov, R. (2013) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2272952 · Cited by 124
A 1-V 0.25- $\mu \text{W}$ Inverter Stacking Amplifier With 1.07 Noise Efficiency Factor
Shen, L., Lu, N., & Sun, N. (2018) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2017.2786724 · Cited by 101
A 48.6-to-105.2 µW Machine Learning Assisted Cardiac Sensor SoC for Mobile Healthcare Applications
Hsu, S.-Y., Ho, Y., Chang, P.-Y., Su, C., & Lee, C.-Y. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2297406 · Cited by 82
Zhu, B., Shin, U., & Shoaran, M. (2021) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2021.3112756 · Cited by 67
“This approach offers significant advantages over the conventional wireless transmission and external processing methods [19], [20] that suffer from feedback loop latency, high power consumption due to continuous telemetry, security and privacy concerns [21], [22].”
BackgroundMulti-Channel Neural Recording Implants: A Review
Hashemi Noshahr, F., Nabavi, M., & Sawan, M. (2020) · Sensors · doi:10.3390/s20030904 · Cited by 66
“To improve the input impedance of this neural amplifier, an input impedance boosting circuit is utilized in [75,76] as shown in Figure 7b.”
BackgroundMethodInfluential32.9 nV/rt Hz ${-}$60.6 dB THD Dual-Band Micro-Electrode Array Signal Acquisition IC
Guo, J., Yuan, J., Huang, J., Law, J. K.-Y., Yeung, C.-K., & Chan, M. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2012.2185590 · Cited by 45
Lee, K. H., Kung, S.-Y., & Verma, N. (2012) · Journal of Signal Processing Systems · doi:10.1007/s11265-012-0672-8 · Cited by 35
“The recent emergence of low-power ambulatory recording technologies for biomedical signals [1–3] raises unprecedented opportunities for devices to add substantial clinical value.”
BackgroundSelf-citationA Low-Power 0.7 $\mu {\rm V_{rms}}$ 32-Channel Mixed-Signal Circuit for ECoG Recordings
Robinet, S., Audebert, P., Regis, G., Zongo, B., Beche, J.-F., Condemine, C., Filipe, S., & Charvet, G. (2011) · IEEE Journal on Emerging and Selected Topics in Circuits and Systems · doi:10.1109/jetcas.2011.2180835 · Cited by 30
High-density neural recording system design
Lee, H.-S., Eom, K., Park, M., Ku, S.-B., Lee, K., & Lee, H.-M. (2022) · Biomedical Engineering Letters · doi:10.1007/s13534-022-00233-z · Cited by 17
Design Considerations for Implantable Neural Circuits and Systems
Hsu, W.-Y., Hsieh, P.-H., & Chen, H. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_19 · Cited by 1
Metadata
- Authors
- Verma, N., Shoeb, A., Bohorquez, J., Dawson, J., Guttag, J., & Chandrakasan, A. P.
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2010-04
- Volume
- 45
- Issue
- 4
- Pages
- 804-816
- ISSN
- 0018-9200 (ISSN-L)
- 1558-173X
- OpenAlex
- W2169766445
- Cited by
- 526
- References
- 18
- FWCI
- 24.76
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.