HMFP-DBRNN: Real-Time Hand Motion Filtering and Prediction via Deep Bidirectional RNN
The DOI matches its Crossref record; 39 of the 45 references it cites were found in a registry or an index.
Abstract
Pathological hand tremor (PHT) is among the most common movement symptoms of several neurological disorders including Parkinson's disease and essential tremor. Extracting PHT is of paramount importance in several engineering and clinical applications such as assistive and robotic rehabilitation technologies. In such systems, PHT is modeled as the input noise to the system and thus there is a surge of interest in estimation an compensation of the noise. Although various works in the literature have attempted to estimate and extract the PHT, in this letter, first, we argue that the ground truth signal used in existing works to optimize the performance of tremor extraction techniques is not accurate enough, and thus the performance measures for the prior techniques are not perfectly reliable. In addition, most of the existing tremor extraction techniques impose unrealistic assumptions, which are, typically, violated in practical settings. This letter proposes a novel technique that for the first time incorporates deep bidirectional recurrent neural networks as a processing tool for PHT extraction. Moreover, we devise an intuitively pleasing training strategy that enables the network to perform not only online estimation but also online prediction of the voluntary hand motion in a myopic fashion, which is currently a significantly important unmet need for rehabilitative and assistive robotic technologies designed for patients with pathological tremor.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Although these estimators have shown promising results, there is not enough evidence to demonstrate that these estimators provide better performance when estimating tremor than the non-neuralnetwork-based estimators, let alone their high requirements for computational power.”
From Real-Time Performance Assessment of High-Order Tremor Estimators Used in a Wearable Tremor Suppression Device (2022) · cites this paper as [33]
Citations
Cites
Adam: A Method for Stochastic Optimization
Kingma, D. P., & Ba, J. (2014) · arXiv · doi:10.48550/arxiv.1412.6980 · Cited by 98,946
Learning Phrase Representations using RNN Encoder–Decoder for Statistical Machine Translation
Cho, K., van Merrienboer, B., Gulcehre, C., Bahdanau, D., Bougares, F., Schwenk, H., & Bengio, Y. (2014) · Proceedings of the 2014 Conference on Empirical Methods in Natural Language Processing (EMNLP) · doi:10.3115/v1/d14-1179 · Cited by 25,545
(2010) · International Conference on Machine Learning · Cited by 13,995
Empirical Evaluation of Gated Recurrent Neural Networks on Sequence Modeling
Chung, J., Gulcehre, C., Cho, K., & Bengio, Y. (2014) · arXiv · doi:10.48550/arxiv.1412.3555 · Cited by 11,008
Bidirectional recurrent neural networks
Schuster, M., & Paliwal, K. K. (1997) · IEEE Transactions on Signal Processing · doi:10.1109/78.650093 · Cited by 10,172 · cited 1×
“To exploit all the available information, the Bidirectional Recurrent Neural Networks (BRNNs) are developed [38].”
MethodAn EMG-Based Control for an Upper-Limb Power-Assist Exoskeleton Robot
Kiguchi, K., & Hayashi, Y. (2012) · IEEE Transactions on Systems, Man, and Cybernetics, Part B (Cybernetics) · doi:10.1109/tsmcb.2012.2185843 · Cited by 531
Source separation using single channel ICA
Davies, M. E., & James, C. J. (2007) · Signal Processing · doi:10.1016/j.sigpro.2007.01.011 · Cited by 301
Clinically deployable Kinesia™ technology for automated tremor assessment
Giuffrida, J. P., Riley, D. E., Maddux, B. N., & Heldman, D. A. (2009) · Movement Disorders · doi:10.1002/mds.22445 · Cited by 251
Machine learning-based classification of simple drawing movements in Parkinson's disease
Kotsavasiloglou, C., Kostikis, N., Hristu-Varsakelis, D., & Arnaoutoglou, M. (2017) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2016.08.003 · Cited by 182
Online tremor suppression using electromyography and low-level electrical stimulation
Dosen, S., Muceli, S., Dideriksen, J. L., Romero, J. P., Rocon, E., Pons, J., & Farina, D. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2328296 · Cited by 120
Research works printed but not linked: 4
- goodfellow, 2016, Deep Learning
- 10.1016/j.bspc.2010.02.005 · DOI · Paper page
- 10.1016/j.bspc.2013.10.004 · DOI · Paper page
- veluvolu, 2010, Double adaptive fourier linear combiner for real-time estimation/filtering of tremor, J Biomed Signal Process Control, 5, 33
Cited by
- Retracted
Menguc, E. C., cnar, S., Xiang, M., & P. Mandic, D. (2021) · IEEE Signal Processing Letters · doi:10.1109/lsp.2021.3097279 · Cited by 25
Human Arm Motion Prediction for Collision Avoidance in a Shared Workspace
Zheng, P., Wieber, P.-B., Baber, J., & Aycard, O. (2022) · Sensors · doi:10.3390/s22186951 · Cited by 23
Real time estimation and suppression of hand tremor for surgical robotic applications
Kumar, A., Kumar, S., Kaushik, A. K., Kumar, A., & Saini, J. S. (2020) · Microsystem Technologies · doi:10.1007/s00542-019-04736-1 · Cited by 17
Prediction of Voluntary Motion Using Decomposition-and-Ensemble Framework With Deep Neural Networks
Yoon, D., Kim, E., Choi, I., Han, S. W., & Yang, S. (2020) · IEEE Access · doi:10.1109/access.2020.3035498 · Cited by 12
Metadata
- Authors
- Shahtalebi, S., Atashzar, S. F., Patel, R. V., & Mohammadi, A.
- Affiliations
- Concordia University (CA)
- Imperial College London (GB)
- Western University (CA)
- Venue
- IEEE Robotics and Automation Letters
- Published
- 2019-04
- Volume
- 4
- Issue
- 2
- Pages
- 1061-1068
- ISSN
- 2377-3766 (ISSN-L)
- 2377-3774
- OpenAlex
- W2908523746
- Cited by
- 17
- References
- 45
- Citations by year
- 2025: 3 · 2024: 1 · 2023: 1 · 2022: 3 · 2021: 3 · 2020: 4 · 2019: 2
- FWCI
- 1.75
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Robotics and Automation Letters (publishedVersion)
- Funders
- Fonds de Recherche du Québec Nature et Technologies (206591 EQ)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Health Sciences › Medicine › Clinical Neurology › Deep Brain Stimulation and Movement Disorders
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- tremor filtering, online estimation, online prediction, Parkinson's disease, essential tremor, rehabilitation robotics, assistive robotics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: HMFP-DBRNN: Real-Time Hand Motion Filtering and Prediction via Deep Bidirectional RNN. https://app.cochat.ai/papers/10.1109/lra.2019.2894005
- The paper
- Shahtalebi, S., Atashzar, S. F., Patel, R. V., & Mohammadi, A. (2019). HMFP-DBRNN: Real-Time Hand Motion Filtering and Prediction via Deep Bidirectional RNN. IEEE Robotics and Automation Letters. https://doi.org/10.1109/lra.2019.2894005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.