CoChat

HMFP-DBRNN: Real-Time Hand Motion Filtering and Prediction via Deep Bidirectional RNN

Shahtalebi, Soroosh, Atashzar, Seyed Farokh, Patel, Rajni V., Mohammadi, Arash · 2019 · IEEE Robotics and Automation Letters

The DOI matches its Crossref record; 39 of the 45 references it cites were found in a registry or an index.

Abstract

Pathological hand tremor (PHT) is among the most common movement symptoms of several neurological disorders including Parkinson's disease and essential tremor. Extracting PHT is of paramount importance in several engineering and clinical applications such as assistive and robotic rehabilitation technologies. In such systems, PHT is modeled as the input noise to the system and thus there is a surge of interest in estimation an compensation of the noise. Although various works in the literature have attempted to estimate and extract the PHT, in this letter, first, we argue that the ground truth signal used in existing works to optimize the performance of tremor extraction techniques is not accurate enough, and thus the performance measures for the prior techniques are not perfectly reliable. In addition, most of the existing tremor extraction techniques impose unrealistic assumptions, which are, typically, violated in practical settings. This letter proposes a novel technique that for the first time incorporates deep bidirectional recurrent neural networks as a processing tool for PHT extraction. Moreover, we devise an intuitively pleasing training strategy that enables the network to perform not only online estimation but also online prediction of the voluntary hand motion in a myopic fashion, which is currently a significantly important unmet need for rehabilitative and assistive robotic technologies designed for patients with pathological tremor.

Overview

Integrity signals

Registry

Crossref · 10.1109/lra.2019.2894005

Cites

39 of 39 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 39 references

Research works printed but not linked: 4

  1. goodfellow, 2016, Deep Learning
  2. 10.1016/j.bspc.2010.02.005 · DOI · Paper page
  3. 10.1016/j.bspc.2013.10.004 · DOI · Paper page
  4. veluvolu, 2010, Double adaptive fourier linear combiner for real-time estimation/filtering of tremor, J Biomed Signal Process Control, 5, 33

Cited by

See all 17

Metadata

Authors
Shahtalebi, S., Atashzar, S. F., Patel, R. V., & Mohammadi, A.
Affiliations
  • Concordia University (CA)
  • Imperial College London (GB)
  • Western University (CA)
Venue
IEEE Robotics and Automation Letters
Published
2019-04
Volume
4
Issue
2
Pages
1061-1068
ISSN
  • 2377-3766 (ISSN-L)
  • 2377-3774
OpenAlex
W2908523746
Cited by
17
References
45
Citations by year
2025: 3 · 2024: 1 · 2023: 1 · 2022: 3 · 2021: 3 · 2020: 4 · 2019: 2
FWCI
1.75
Type
journal article
Language
en
Open access
closed
Locations
IEEE Robotics and Automation Letters (publishedVersion)
Funders
Fonds de Recherche du Québec Nature et Technologies (206591 EQ)
Topics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
  • Health Sciences › Medicine › Clinical Neurology › Deep Brain Stimulation and Movement Disorders
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
Keywords
tremor filtering, online estimation, online prediction, Parkinson's disease, essential tremor, rehabilitation robotics, assistive robotics

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: HMFP-DBRNN: Real-Time Hand Motion Filtering and Prediction via Deep Bidirectional RNN. https://app.cochat.ai/papers/10.1109/lra.2019.2894005
The paper
Shahtalebi, S., Atashzar, S. F., Patel, R. V., & Mohammadi, A. (2019). HMFP-DBRNN: Real-Time Hand Motion Filtering and Prediction via Deep Bidirectional RNN. IEEE Robotics and Automation Letters. https://doi.org/10.1109/lra.2019.2894005

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.