Online Censoring Based Weighted-Frequency Fourier Linear Combiner for Estimation of Pathological Hand Tremors
The DOI matches its Crossref record; 35 of the 38 references it cites were found in a registry or an index.
Abstract
An online censoring (OC) based weighted-frequency Fourier linear combiner (OC-WFLC) adaptive filtering structure is proposed to reduce data processing costs in the estimation of pathological hand tremor (PHT) measurements. The proposed OC-WFLC is combined with the Fourier linear combiner (FLC) to effectively separate the PHT and voluntary movement from the hand tremor signal. The OC-WFLC is shown to adaptively extract the most informative frequency information, that is readily employed within the FLC to adaptively decompose the measurement signal into its PHT and voluntary movement components. The utilization of the OC strategy in the proposed framework is shown to significantly reduce data processing costs without adverse effects on the performance. Simulation results on real-world PHT data demonstrate the ability of the proposed OC-WFLC to yield a dramatic reduction of the processing time, a prerequisite for real-time rehabilitative, wearable, and assistive technology designed for PHT patients.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Recurrent Neural Networks for Prediction: Learning Algorithms, Architectures and Stability
Mandic, D. P., & Chambers, J. A. (2001) · Wiley eBooks · doi:10.1002/047084535x · Cited by 829
Self-citationRecurrent Neural Networks for Prediction: Learning Algorithms,Architectures and Stability
Mandic, D. P., & Chambers, J. A. (2001) · ORCA Online Research @Cardiff (Cardiff University) · Cited by 640
Self-citationDesign and Validation of a Rehabilitation Robotic Exoskeleton for Tremor Assessment and Suppression
Rocon, E., Belda-Lois, J. M., Ruiz, A. F., Manto, M., Moreno, J. C., & Pons, J. L. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903917 · Cited by 349
Adaptive cancelling of physiological tremor for improved precision in microsurgery
Riviere, C. N., Rader, R. S., & Thakor, N. V. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.686791 · Cited by 260
Balasubramanian, C. K., Neptune, R. R., & Kautz, S. A. (2009) · Gait & Posture · doi:10.1016/j.gaitpost.2008.10.061 · Cited by 250
Electrical stimulation for the suppression of pathological tremor
Popović Maneski, L., Jorgovanović, N., Ilić, V., Došen, S., Keller, T., Popović, M. B., & Popović, D. B. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0803-6 · Cited by 129
Estimation of physiological tremor from accelerometers for real-time applications
Veluvolu, K. C., & Ang, W. T. (2011) · Sensors · doi:10.3390/s110303020 · Cited by 117
Modeling and canceling tremor in human-machine interfaces
Riviere, C. N., & Thakor, N. V. (1996) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.499755 · Cited by 114
An adaptive estimation of periodic signals using a Fourier linear combiner
Vaz, C., Kong, X., & Thakor, N. (1994) · IEEE Transactions on Signal Processing · doi:10.1109/78.258116 · Cited by 108
Online Censoring for Large-Scale Regressions with Application to Streaming Big Data
Berberidis, D., Kekatos, V., & Giannakis, G. B. (2016) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2016.2546225 · Cited by 86
Bandlimited Multiple Fourier Linear Combiner for Real-time Tremor Compensation
Veluvolu, K. C., Tan, U. X., Latt, W. T., Shee, C. Y., & Ang, W. T. (2007) · 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2007.4352922 · Cited by 83
3-D motion system ("data-gloves"): application for Parkinson's disease
Su, Y., Allen, C. R., Geng, D., Burn, D. J., Brechany, U., Bell, G. D., & Rowland, R. (2003) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2003.814702 · Cited by 68
Multistep Prediction of Physiological Tremor for Surgical Robotics Applications
Veluvolu, K. C., Tatinati, S., Hong, S.-M., & Ang, W. T. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2264546 · Cited by 51
Bilateral tremor relations in Parkinson's disease: Effects of mechanical coupling and medication
Morrison, S., Kerr, G., & Silburn, P. A. (2007) · Parkinsonism & Related Disorders · doi:10.1016/j.parkreldis.2007.09.004 · Cited by 50
On Data-Selective Adaptive Filtering
(2018) · doi:10.1109/tsp.2018.2847657 · Cited by 47
Atashzar, S. F., Shahbazi, M., Samotus, O., Tavakoli, M., Jog, M. S., & Patel, R. V. (2016) · IEEE Journal of Selected Topics in Signal Processing · doi:10.1109/jstsp.2016.2530632 · Cited by 45
Widely Linear Quaternion-Valued Least-Mean Kurtosis Algorithm
Mengüç, E. C., Acır, N., & Mandic, D. P. (2020) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2020.3029959 · Cited by 45
Self-citationAdaptive sliding bandlimited multiple fourier linear combiner for estimation of pathological tremor
Wang, S., Gao, Y., Zhao, J., & Cai, H. (2014) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2013.10.004 · Cited by 42
Characterization of Parkinsonian Hand Tremor and Validation of a High-Order Tremor Estimator
Zhou, Y., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2859793 · Cited by 42
(2005) · doi:10.4324/9780203390979 · Cited by 41
Closed-Loop Control of Tremor-Predominant Parkinsonian State Based on Parameter Estimation
Liu, C., Wang, J., Deng, B., Wei, X., Yu, H., Li, H., Fietkiewicz, C., & Loparo, K. A. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2535358 · Cited by 38
Shahtalebi, S., Atashzar, S. F., Samotus, O., Patel, R. V., Jog, M. S., & Mohammadi, A. (2020) · Scientific Reports · doi:10.1038/s41598-020-58912-9 · Cited by 32
Decentralized RLS With Data-Adaptive Censoring for Regressions Over Large-Scale Networks
Wang, Z., Yu, Z., Ling, Q. H., Berberidis, D., & Giannakis, G. B. (2018) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2018.2795594 · Cited by 32
Andò, B., Baglio, S., Marletta, V., Pistorio, A., Dibilio, V., Mostile, G., Nicoletti, A. S. Q., & Zappia, M. (2017) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2017.2753478 · Cited by 30
Shahtalebi, S., Atashzar, S. F., Patel, R. V., & Mohammadi, A. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2018.10.007 · Cited by 29
Assessment of level-walking aperiodicity
Pecoraro, F., Mazzà, C., Zok, M., & Cappozzo, A. (2006) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-3-28 · Cited by 27
An augmented complex-valued Lyapunov stability theory based adaptive filter algorithm
(2017) · doi:10.1016/j.sigpro.2017.01.031 · Cited by 20
Self-citationAdaptive Queuing Censoring for Big Data Processing
(2018) · doi:10.1109/lsp.2018.2815006 · Cited by 19
Real time estimation and suppression of hand tremor for surgical robotic applications
Kumar, A., Kumar, S., Kaushik, A. K., Kumar, A., & Saini, J. S. (2020) · Microsystem Technologies · doi:10.1007/s00542-019-04736-1 · Cited by 17
HMFP-DBRNN: Real-Time Hand Motion Filtering and Prediction via Deep Bidirectional RNN
Shahtalebi, S., Atashzar, S. F., Patel, R. V., & Mohammadi, A. (2019) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2019.2894005 · Cited by 17
Prediction of Voluntary Motion Using Decomposition-and-Ensemble Framework With Deep Neural Networks
Yoon, D., Kim, E., Choi, I., Han, S. W., & Yang, S. (2020) · IEEE Access · doi:10.1109/access.2020.3035498 · Cited by 12
Features of parkinsonian and essential tremor of the human hand
Dick, O. E., & Ad, N. (2016) · Human Physiology · doi:10.1134/s0362119716030063 · Cited by 9
Nonstationary Portfolios: Diversification in the Spectral Domain
(2021) · doi:10.1109/icassp39728.2021.9413769 · Cited by 8
Self-citationHANDBOOK OF ESSENTIAL TREMOR AND OTHER TREMOR DISORDERS
Tarsy, D. (2008) · Neurology · doi:10.1212/01.wnl.0000285529.87744.af · Cited by 5
Mengüç, E. C. (2019) · Transactions of the Institute of Measurement and Control · doi:10.1177/0142331219889171 · Cited by 4
Self-citation
Research works printed but not linked: 2
- khalil, 1992, Nonlinear Systems
- elble, 1990, Tremor
Cited by
Data-Adaptive Censoring for Short-Term Wind Speed Predictors Based on MLP, RNN, and SVM
(2022) · doi:10.1109/jsyst.2022.3150749 · Cited by 50
Self-citationOnline censoring based complex-valued adaptive filters
(2022) · doi:10.1016/j.sigpro.2022.108638 · Cited by 27
Self-citationA Class of Online Censoring Based Quaternion-Valued Least Mean Square Algorithms
Mengüç, E. C., Acır, N., & Mandic, D. P. (2023) · IEEE Signal Processing Letters · doi:10.1109/lsp.2023.3255000 · Cited by 25
Self-citationA Tremor Suppression and Noise Removal Algorithm for Microscopic Robot-Assisted Cataract Surgery
Bian, G., Wang, J., Fu, P., Wei, B.-T., Li, M., & Li, Z. (2023) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2023.3254161 · Cited by 22
Metadata
- Authors
- Menguc, E. C., cnar, S., Xiang, M., & P. Mandic, D.
- Affiliations
- Niğde Ömer Halisdemir Üniversitesi (TR)
- Beihang University (CN)
- Venue
- IEEE Signal Processing Letters
- Published
- 2021
- Volume
- 28
- Pages
- 1460-1464
- ISSN
- 1070-9908 (ISSN-L)
- 1558-2361
- OpenAlex
- W3185828489
- Semantic Scholar
- f02a6b8ce236a63b93bc502c9b9c71ac8f940334
- Cited by
- 25
- References
- 38
- Citations by year
- 2026: 1 · 2025: 6 · 2024: 3 · 2023: 10 · 2022: 3 · 2021: 2
- FWCI
- 2.55
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Signal Processing Letters (publishedVersion)
- Kayseri University - Avesis (submittedVersion)
- Niğde Üniversitesi Açık Erişim Sistemi (submittedVersion)
- Topics
- Physical Sciences › Computer Science › Signal Processing › Advanced Adaptive Filtering Techniques
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Keywords
- adaptive filtering, signal decomposition, computational complexity reduction, wearable assistive technology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.