Abstract
Silicon-based microsystems are being developed to interface with the central nervous system (CNS) at the cellular level. Dense three-dimensional (3-D) microelectrode arrays with as many as several hundred sites permit acute and semichronic single-unit recording and stimulation, while on-chip circuitry for site selection, amplification, and multiplexing reduces noise and limits the number of output leads to manageable levels. Hybrid implant-mounted circuitry can be used to separate single units from baseline noise and provide simultaneous wireless access to more than a hundred information channels. This article focuses on the technology for electronically interfacing with the CNS at the cellular level. Devices based on silicon-on-insulator technology and silicon array structures not based as directly on the planar processes of ICs are given notice. Tissue interface and cabling problems still exist for long-term applications but the basic technology platform is robust and should allow engineering solutions to be developed over time. Present technology is consistent with real breakthroughs in our understanding of the brain at the circuit/system level during the coming decade though detailed mapping that has been impossible in the past. Such mapping could also serve as a basis for prosthetic devices for treating some of mankind's most debilitating disorders.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Traditional commercial implantable neural interfaces (e.g., Utah electrodes[306] and Michigan electrodes[307]) typically contain noble metals[308] (high conductivity and chemical stability), and silicon-based materials[309] (ideally suited to existing microfabrication techniques) as electrodes.”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [307]
Citations
Cites
Mechanisms of Gamma Oscillations in the Hippocampus of the Behaving Rat
Csicsvari, J., Jamieson, B., Wise, K. D., & Buzsáki, G. (2003) · Neuron · doi:10.1016/s0896-6273(02)01169-8 · Cited by 1,001
Self-citationWireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
Self-citationFlexible polyimide-based intracortical electrode arrays with bioactive capability
Rousche, P. J., Pellinen, D. S., Pivin, D. P., Williams, J. C., Vetter, R. J., & Kipke, D. R. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914800 · Cited by 644
Maynard, E. M., Nordhausen, C. T., & Normann, R. A. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(96)95176-0 · Cited by 640
A miniature microelectrode array to monitor the bioelectric activity of cultured cells
THOMASJR, C., SPRINGER, P., LOEB, G., BERWALDNETTER, Y., & OKUN, L. (1972) · Experimental Cell Research · doi:10.1016/0014-4827(72)90481-8 · Cited by 580
An Integrated-Circuit Approach to Extracellular Microelectrodes
Wise, K. D., Angell, J. B., & Starr, A. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502738 · Cited by 544
Self-citationSurface modification of neural recording electrodes with conducting polymer/biomolecule blends
Cui, X., Lee, V. A., Raphael, Y., Wiler, J. A., Hetke, J. F., Anderson, D. J., & Martin, D. C. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200108)56:2<261::aid-jbm1094>3.0.co;2-i · Cited by 530
Chronic Neural Recording Using Silicon-Substrate Microelectrode Arrays Implanted in Cerebral Cortex
Vetter, R. J., Williams, J. C., Hetke, J. F., Nunamaker, E. A., & Kipke, D. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826680 · Cited by 475
Massively Parallel Recording of Unit and Local Field Potentials With Silicon-Based Electrodes
Csicsvari, J., Henze, D. A., Jamieson, B., Harris, K. D., Sirota, A., Barthó, P., Wise, K. D., & Buzsáki, G. (2003) · Journal of Neurophysiology · doi:10.1152/jn.00116.2003 · Cited by 402
Self-citationKipke, D. R., Vetter, R. J., Williams, J. C., & Hetke, J. F. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814443 · Cited by 367
Research works printed but not linked: 2
- Wise, 2004, Wireless implantable microsystems: Electronic interface to the nervous system, 76
- 10.31438/trf.hh1994.7 · doi:10.31438/trf.hh1994.7
Cited by
Items 101–200 of 220
Yin, M., Field, R., & Ghovanloo, M. (2006) · International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology (MMB) · doi:10.1109/mmb.2006.251555 · Cited by 17
Flexible neural recording electrodes based on reduced graphene oxide interfaces
Dong, M., Chen, P., Zhou, K., Marroquin, J. B., Liu, M., Thomas, S., Coleman, H. A., Li, D., Fallon, J. B., Majumder, M., et al. (2023) · Chemical Engineering Journal · doi:10.1016/j.cej.2023.147067 · Cited by 16
An Ultra Low Power System Architecture for Implantable Medical Devices
Kakkar, V. (2018) · IEEE Access · doi:10.1109/access.2018.2799422 · Cited by 16
Hackworth, S. A. (2010) · D-Scholarship@Pitt (University of Pittsburgh) · Cited by 16
Goncalves, S. B., Peixoto, A. C., da Silva, A. F., & Correia, J. H. (2015) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/25/5/055014 · Cited by 16
Zhao, Z., Gong, R., Huang, H., & Wang, J. (2016) · Sensors · doi:10.3390/s16060880 · Cited by 16
In Vivo Neural Interfaces—From Small- to Large-Scale Recording
Zhang, B., Deng, C., Cai, C., & Li, X. (2022) · Frontiers in Nanotechnology · doi:10.3389/fnano.2022.885411 · Cited by 15
Ghane-Motlagh, B., Choueib, M., Mesgar, A. H., Hasanuzzaman, M., & Sawan, M. (2016) · Micromachines · doi:10.3390/mi7090163 · Cited by 14
Riera, J. J., Goto, T., & Kawashima, R. (2014) · Frontiers in Neural Circuits · doi:10.3389/fncir.2014.00004 · Cited by 14
Shandhi, M. M. H., & Negi, S. (2020) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2020.3004847 · Cited by 13
Hemed, N. M., & Melosh, N. A. (2023) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2023.114723 · Cited by 13
Biomimetics Through Nanoelectronics
Liu, J. (2017) · Springer theses · doi:10.1007/978-3-319-68609-7 · Cited by 13
Biofunctionalized platforms towards long-term neural interface
Chen, N., Luo, B., Yang, I. H., Thakor, N. V., & Ramakrishna, S. (2018) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2018.03.002 · Cited by 12
Minimally Invasive & Long‐lasting Neural Probes from a Materials Perspective
Veronica, A., Li, Y., & Hsing, I. (2019) · Electroanalysis · doi:10.1002/elan.201800719 · Cited by 12
Ng, D. C., Tokuda, T., Shiosaka, S., Tano, Y., & Ohta, J. (2008) · Sensors · doi:10.3390/s8053183 · Cited by 12
Biochips and other microtechnologies for physiomics
Haque, A. U., Chatni, M. R., Li, G., & Porterfield, D. M. (2007) · Expert Review of Proteomics · doi:10.1586/14789450.4.4.553 · Cited by 11
Extreme manufacturing of minimally invasive intracortical neural electrodes
Xu, M., Zhu, Z., Ma, H., Zhou, G., Iliasov, A., Chen, Z., Tsang, W. M., Wu, J., Li, C., Wei, X., et al. (2025) · International Journal of Extreme Manufacturing · doi:10.1088/2631-7990/ae2579 · Cited by 11
Kampasi, K., Seymour, J. P., Na, K., Wise, K. D., & Yoon, E.-S. (2015) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/transducers.2015.7180914 · Cited by 10
Self-citationA Wideband Wireless Neural Stimulation Platform for High-Density Microelectrode Arrays
Myers, F. B., Simpson, J. A., & Ghovanloo, M. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.260294 · Cited by 10
Kubo, T., Katayama, N., Karashima, A., & Nakao, M. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4650341 · Cited by 10
Riera, J. J., Ogawa, T., Hatanaka, R., Goto, T., Sumiyoshi, A., Enjieu-Kadji, H., Nakauchi, S., & Kawashima, R. (2010) · Journal of Biophotonics · doi:10.1002/jbio.200910036 · Cited by 10
A 1V 420μW 32-channel Cortical Signal Interface
Lee, E. K. F., Matei, E., Lam, A., & Li, T. (2006) · Custom Integrated Circuits Conference · doi:10.1109/cicc.2006.320858 · Cited by 9
Platform technologies to support brain–computer interfaces
Sclabassi, R. J., Liu, Q., Hackworth, S. A., Justin, G. A., & Sun, M. (2006) · Neurosurgical FOCUS · doi:10.3171/foc.2006.20.5.6 · Cited by 9
Al-Attar, A. M. (2010) · International Journal of Zoological Research · doi:10.3923/ijzr.2010.199.213 · Cited by 9
Artificial Eye Vision Using Wireless Sensor Networks
Elsaid, S. A., & Hassanien, A. E. (2013) · CRC Press eBooks · doi:10.1201/b15425-31 · Cited by 8
Prospects for a Robust Cortical Recording Interface
Shoffstall, A. J., & Capadona, J. R. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-805353-9.00028-0 · Cited by 8
Duncan, J. L., Wang, J., Glusauskas, G., Weagraff, G. R., Gao, Y., Hoeferlin, G. F., Hunter, A. H., Hess‐Dunning, A., Ereifej, E. S., & Capadona, J. R. (2024) · Micromachines · doi:10.3390/mi15020286 · Cited by 7
Design and Implementation of Low Noise Amplifier in Neural Signal Analysis
Bansal, M., & Singh, D. (2019) · Communications in computer and information science · doi:10.1007/978-981-15-1384-8_2 · Cited by 7
Demonstration of Monolithic-Silicon Carbide (SiC) Neural Devices
Bernardin, E. K. (2018) · Digital Commons - University of South Florida (University of South Florida) · Cited by 7
Ananth, R. S., Lee, E. K., Li, T., & Lam, A. (2006) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2006.1693149 · Cited by 7
Multiscale Engineering of Ion‐Conducting Gels for Sustainable Bioelectronic Systems
Kim, J. H., Choi, W. H., Kim, J. H., Park, Y., Yun, S., Kim, T., & Kim, D. H. (2025) · Small Methods · doi:10.1002/smtd.202501625 · Cited by 6
Low power implantable neural recording front-end
Do, A. T., Tan, Y., Lam, C. K., Je, M., & Yeo, K. S. (2012) · International SoC Design Conference · doi:10.1109/isocc.2012.6407122 · Cited by 6
Flexible Electrode for Implantable Neural Devices
Tsang, W. M., & Je, M. (2014) · Springer eBooks · doi:10.1007/978-1-4614-8151-5_6 · Cited by 6
Karnati, C., Aguilar, R., Arrowood, C. A., Ross, J., & Rajaraman, S. (2017) · Micromachines · doi:10.3390/mi8080250 · Cited by 6
A 0.9 V Rail-to-Rail Constant gmAmplifier for Implantable Biomedical Applications
Lee, E. K. F., Matei, E., & Ananth, R. S. (2006) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2006.1692670 · Cited by 6
Ng, D. C., Nakagawa, T., Tokuda, T., Nunoshita, M., Tamura, H., Ishikawa, Y., Shiosaka, S., & Ohta, J. (2007) · Japanese Journal of Applied Physics · doi:10.1143/jjap.46.2811 · Cited by 6
High-density 3D pyramid-shaped microelectrode arrays for brain-machine interface applications
Ghane-Motlagh, B., & Sawan, M. (2014) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2014.6981738 · Cited by 5
High-Aspect Ratio Si Neural Shafts: Fabrication and Brain Implantation
Goncalves, S. B., Loureiro, A. M. D. S., Fernandes, H. C., Pimenta, S., Ribeiro, J. F., & Correia, J. H. (2018) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2018.2868229 · Cited by 5
Sugiura, T., Imai, M., Yu, J., & Takeuchi, Y. (2017) · Journal of Information Processing · doi:10.2197/ipsjjip.25.210 · Cited by 5
The Biocompatibility of Intracortical Microelectrode Recording Arrays for Brain Machine Interfacing
Skousen, J. L., & Tresco, P. A. (2017) · Series on bioengineering and biomedical engineering · doi:10.1142/9789813207158_0011 · Cited by 5
High-Density Implantable Microelectrode Arrays for Brain-Machine Interface Applications
Ghane-Motlagh, B., & Sawan, M. (2014) · Advances in science and technology · doi:10.4028/www.scientific.net/ast.96.95 · Cited by 5
Controlled Release Drug Coatings on Flexible Neural Probes
Mercanzini, A., Reddy, S. T., Velluto, D., Colin, P., Maillard, A., Bensadoun, J., Bertsch, A., Hubbell, J. A., & Renaud, P. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353875 · Cited by 5
Microfabrication Techniques for Printing on PDMS Elastomers for Antenna and Biomedical Applications
Apaydin, E. (2009) · OhioLink ETD Center (Ohio Library and Information Network) · Cited by 5
Emerging diverse 3D neural electrode architectures for bioelectronics
Paek, J., Park, W., Song, H., Jeong, I., Oh, M., Kim, E., Kim, D., An, S. H., Kim, Y. W., Chung, W. G., et al. (2026) · Nanoscale Horizons · doi:10.1039/d5nh00844a · Cited by 4
Thin-Film Microelectrode Arrays for Biomedical Applications
Cheung, K. C. (2010) · Biological and medical physics series · doi:10.1007/978-0-387-98120-8_6 · Cited by 5
Flexible Neural Probe with an Optimized Electrode Density for Neutral Investigations
Park, S., Lee, H., Kim, M., Chou, N., & Shin, H. (2025) · ACS Omega · doi:10.1021/acsomega.5c02700 · Cited by 4
Gross, B. A., & Hanna, D. M. (2010) · Pattern Recognition · doi:10.1016/j.patcog.2010.05.034 · Cited by 4
Multisite monitoring of choline using biosensor microprobe arrays in combination with CMOS circuitry
Frey, O., Rothe, J., Heer, F., van der Wal, P. D., de Rooij, N. F., & Hierlemann, A. R. (2013) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt-2012-0098 · Cited by 4
Electrical interfaces for recording, stimulation, and sensing
Hess‐Dunning, A., & Zorman, C. A. (2015) · Elsevier eBooks · doi:10.1016/b978-0-323-26208-8.00002-9 · Cited by 4
A programmable controller for spatio-temporal pattern stimulation of cortical visual prosthesis
Sugiura, T., Khan, A. U., Yu, J., Takeuchi, Y., Kameda, S., Kamata, T., Hayashida, Y., Yagi, T., & Imai, M. (2016) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2016.7833824 · Cited by 4
Electrochemical Analysis of Single Cells
Mozneb, M., Smothers, C. G., Rodriguez, P., & Li, C. (2019) · Wiley eBooks · doi:10.1002/9781119611103.ch4 · Cited by 4
Wang, M., & Guo, L. (2020) · Springer eBooks · doi:10.1007/978-3-030-41854-0_4 · Cited by 4
Miniaturized Resonant Power Conversion for Implanted Medical Devices
Kumar, V., & Kakkar, V. (2017) · IEEE Access · doi:10.1109/access.2017.2728364 · Cited by 4
Byun, D., Oh, K., & Kim, S. (2015) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2015.7370594 · Cited by 3
Sugiura, T., Nakatsuka, S., Yu, J., Takeuchi, Y., & Imai, M. (2014) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2014.6981650 · Cited by 3
Novel Porous Brain Electrodes for Augmented Local Field Potential Signal Detection
Lee, S. H., Lee, K.-S., Sorcar, S., Razzaq, A., Lee, M., & In, S. (2019) · Materials · doi:10.3390/ma12030542 · Cited by 3
Silicon Probe Techniques for Large-Scale Multiunit Recording
Steenland, H. W., & McNaughton, B. L. (2014) · Springer series in computational neuroscience · doi:10.1007/978-1-4939-1969-7_2 · Cited by 3
Kim, J., Kim, S., & Lee, K. (2017) · Japanese Journal of Applied Physics · doi:10.7567/jjap.56.06gn13 · Cited by 3
Consciousness for Artificial Intelligence?
Johnson, A. T. (2023) · IEEE Pulse · doi:10.1109/mpuls.2024.3354609 · Cited by 3
Introduction to Sensors and General Applications
ISLAM, S. K., & Haider, M. R. (2009) · Springer eBooks · doi:10.1007/978-0-387-79392-4_1 · Cited by 2
Wallace, G. G., Moulton, S. E., Kapsa, R. M., & Higgins, M. J. (2012) · Wiley eBooks · doi:10.1002/9783527646029.ch1 · Cited by 2
Independent positioning of microelectrodes for multisite recordings in vitro
Albus, K., Sinske, K., & Heinemann, U. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2008.09.001 · Cited by 2
Micromachining Techniques for Realization of Three-Dimensional Microelectrode Arrays
Rajaraman, S. (2014) · Springer eBooks · doi:10.1007/978-1-4899-8038-0_5 · Cited by 2
Tathireddy, P., Solzbacher, F., Hitchcock, R., & Hoffmann, K. (2011) · Springer eBooks · doi:10.1007/978-3-540-74658-4_40 · Cited by 2
Intra-Cortical Microelectrode Arrays for Neuro-Interfacing
Gabran, S. R. I. (2012) · UWSpace (University of Waterloo) · Cited by 2
Myllymaa, S. (2010) · UEF eRepo (University of Eastern Finland) · Cited by 2
3-dimensional intracortical neural interface for the study of epilepsy
John, J. K. (2012) · Human Biology · Cited by 2
High-Density Fiberless Optoelectrodes with Integrated Waveguides and μLEDs
Kim, K., Wu, F., Kampasi, K., Seymour, J. P., Wise, K. D., & Yoon, E. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_22 · Cited by 1
Self-citationMechanical Behavior Analysis of Neural Electrode Arrays Implantation in Brain Tissue
Tan, X., Tong, B., Zhang, K., Ni, C., Yang, D., Gao, Z., Huang, Y., Yao, N., & Li, H. (2025) · Micromachines · doi:10.3390/mi16091010 · Cited by 1
Stable Neural Signal Recording Processed by Memristor‐Based Reservoir Computing System
Kim, S., Wu, Y., Moore, F., Hu, M., Zhang, X., Yoo, S., Lee, E. Y., Shen, H., He, Y., Liu, J., et al. (2026) · Advanced Intelligent Systems · doi:10.1002/aisy.202600005 · Cited by 1
Implantable Brain Interface: High-Density Microelectrode Array for Neural Recording
Jun, S. B. (2015) · KAIST research series · doi:10.1007/978-94-017-9981-2_4 · Cited by 1
Fabrication and inductive power transfer in wireless spherical pill microprobes
Likhite, R., Luo, W., Young, D. J., & Mastrangelo, C. H. (2017) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/transducers.2017.7993980 · Cited by 1
Low-cost electrodes for acutely implanted neural recording and stimulation systems
Bozkurt, A. Y. (2012) · IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems (BioWireleSS) · doi:10.1109/biowireless.2012.6172733 · Cited by 1
MEMS as implantable neuroprobes
Govindarajan, A. V., Je, M., Park, W., & Achyuta, A. K. H. (2012) · Elsevier eBooks · doi:10.1533/9780857096272.4.359 · Cited by 1
Wages, N. P., Beck, T. W., Ye, X., & Carr, J. C. (2017) · Physiological Reports · doi:10.14814/phy2.13151 · Cited by 1
Integration of Three-Dimensional Macroporous Nanoelectronics with Materials
Liu, J. (2017) · Springer theses · doi:10.1007/978-3-319-68609-7_3 · Cited by 1
Medical Applications of Micro-Electro-Mechanical Systems (MEMS) Technology
Huff, M. A. (2012) · CRC Press eBooks · doi:10.1201/b12303-4 · Cited by 1
Electrophysiological Techniques for Studying Tactile Perception in Rats
Öztürk, S., Devecıoğlu, İ., Vardar, B., Duvan, F. T., & Güçlü, B. (2023) · Neuromethods · doi:10.1007/978-1-0716-3068-6_16 · Cited by 1
Inspiring a convergent engineering approach to measure and model the tissue microenvironment
Iyer, R. R., Applegate, C. C., Arogundade, O. H., Bangru, S., Berg, I. C., Emon, B., Porras-Gómez, M., Hsieh, P.-H., Jeong, Y., Kim, Y., et al. (2024) · Heliyon · doi:10.1016/j.heliyon.2024.e32546 · Cited by 1
Rajaraman, S., Zhao, Y., Wu, X., Kim, S.-H., & Allen, M. G. (2008) · Cited by 1
Development of a Bi-Directional Electronics Platform for Advanced Neural Applications
Abbati, L. (2012) · Digital Commons - University of South Florida (University of South Florida) · Cited by 1
Polymer-based microimplants for the neurosciences
Rubehn, B. (2010) · FreiDok plus (Universitätsbibliothek Freiburg) · Cited by 1
Pavia, A. (2021) · theses.fr (ABES) · doi:10.70675/7fb2c8b7ze874z49b7z8a58zdc8dabf0c389 · Cited by 1
Microelectrode Implants for Spinal Cord Stimulation in Rats
Nandra, M. S. (2015) · CaltechTHESIS (California Institute of Technology) · doi:10.7907/z9930r3g
Analog Front-End Circuits for Massive Parallel 3-D Neural Microsystems.
Al-Ashmouny, K. M. (2013) · Deep Blue (University of Michigan)
Design and Optimization of Power Supplies for Wireless Integrated Microsystems.
Albano, F. (2008) · Deep Blue (University of Michigan)
Focused Ion Beam Technology as a Fabrication and Inspection Tool in Neuron Interfacing
Sileo, L., Pisanello, F., Martiradonna, L., & Vittorio, M. D. (2014) · Springer eBooks · doi:10.1007/978-1-4899-8038-0_6
Finite Element Analysis of Planar Micromachined Silicon Electrodes for Cortical Stimulation
Field, R., & Ghovanloo, M. (2006) · International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology (MMB) · doi:10.1109/mmb.2006.251533
Low power recording and digitizing circuits for neural prosthetics
Poustinchi, M., Stacey, R. G., & Musallam, S. (2014) · International Caribbean Conference on Devices, Circuits and Systems · doi:10.1109/iccdcs.2014.7016168
MULTICHANNEL PLANAR MICROELECTRODE ARRAY FOR SOMATIC MAPPING IN RATS
Shaw, F.-Z., Yang, T.-F., Huang, C.-C., Yeh, K.-H., Chang, T.-C., & Leu, F.-J. (2011) · Biomedical Engineering Applications Basis and Communications · doi:10.4015/s1016237211002840
Ultra-low-power implantable medical electronics
Sarpeshkar, R. (2010) · Cambridge University Press eBooks · doi:10.1017/cbo9780511841446.019
Oyunerdene, N. (2014) · cIRcle (University of British Columbia) · doi:10.14288/1.0135592
Spanu, A. (2016) · Springer theses · doi:10.1007/978-3-319-28880-2_2
Metamorphic neural interfaces with insects for remote controlled biobots
Bozkurt, A. Y. (2015) · Cambridge University Press eBooks · doi:10.1017/cbo9781139629539.016
Controlled Release Drug Coatings
Mercanzini, A., & Renaud, P. (2011) · EPFL Press eBooks · doi:10.1201/b16408-6
Medical Applications of Micro-Electro-Mechanical Systems (MEMS) Technology
Huff, M. A. (2012) · CRC Press eBooks · doi:10.1201/b12303-7
Barnes, A. (2011) · OhioLink ETD Center (Ohio Library and Information Network)
Microbatteries for Use in a Hybrid Power System for Implanted Neural Probes
Zhang, Y., Lin, Q., Murari, K., Thakor, N. V., & Harb, J. N. (2008) · ECS Meeting Abstracts · doi:10.1149/ma2008-01/38/1196
Layered Nanocomposite for Neural Prosthetic Devices.
Zhang, H. (2014) · Deep Blue (University of Michigan)
The Role of Innate Immunity in the Response to IntracorticalMicroelectrodes
Hermann, J. K. (2018) · OhioLink ETD Center (Ohio Library and Information Network)
Metadata
- Authors
- Wise, K. D.
- Affiliations
- University of Michigan (US)
- Corresponding author
- Wise, K.D.
- Venue
- IEEE Engineering in Medicine and Biology Magazine
- Published
- 2005-09
- Volume
- 24
- Issue
- 5
- Pages
- 22-29
- ISSN
- 0739-5175 (ISSN-L)
- OpenAlex
- W2169061869
- Semantic Scholar
- 67dd8cfcba93c21d7e050f08dabffe34c5e970cc
- Cited by
- 194
- References
- 44
- Citations by year
- 2026: 4 · 2025: 9 · 2024: 3 · 2023: 8 · 2022: 4 · 2021: 6 · 2020: 12 · 2019: 9 · 2018: 10 · 2017: 16 · 2016: 8 · 2015: 8 · 2014: 14 · 2013: 5 · 2012: 17
- FWCI
- 0.77
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Engineering in Medicine and Biology Magazine (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute of Neurological Disorders and Stroke (N01-NS-4-2363)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced MEMS and NEMS Technologies
- Keywords
- silicon microsystems, neural prostheses, neural recording, neurostimulation, microelectrode arrays, single-unit recording, silicon-on-insulator, on-chip signal processing, wireless neural interface, brain mapping, electrode-tissue interface, chronic implantation
- MeSH terms
- Artificial Intelligence, Electrodes, Implanted, Electronics, Electric Stimulation Therapy, Equipment Design, Humans, Microelectrodes, Miniaturization, Nervous System Diseases, Neurosciences, Silicon, Therapy, Computer-Assisted, Equipment Failure Analysis, Prostheses and Implants, Biomimetics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.