Silicon microsystems for neuroscience and neural prostheses
The DOI matches its Crossref record; 42 of the 44 references it cites were found in a registry or an index.
Abstract
Silicon-based microsystems are being developed to interface with the central nervous system (CNS) at the cellular level. Dense three-dimensional (3-D) microelectrode arrays with as many as several hundred sites permit acute and semichronic single-unit recording and stimulation, while on-chip circuitry for site selection, amplification, and multiplexing reduces noise and limits the number of output leads to manageable levels. Hybrid implant-mounted circuitry can be used to separate single units from baseline noise and provide simultaneous wireless access to more than a hundred information channels. This article focuses on the technology for electronically interfacing with the CNS at the cellular level. Devices based on silicon-on-insulator technology and silicon array structures not based as directly on the planar processes of ICs are given notice. Tissue interface and cabling problems still exist for long-term applications but the basic technology platform is robust and should allow engineering solutions to be developed over time. Present technology is consistent with real breakthroughs in our understanding of the brain at the circuit/system level during the coming decade though detailed mapping that has been impossible in the past. Such mapping could also serve as a basis for prosthetic devices for treating some of mankind's most debilitating disorders.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Traditional commercial implantable neural interfaces (e.g., Utah electrodes[306] and Michigan electrodes[307]) typically contain noble metals[308] (high conductivity and chemical stability), and silicon-based materials[309] (ideally suited to existing microfabrication techniques) as electrodes.”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [307]
Citations
Cites
Mechanisms of Gamma Oscillations in the Hippocampus of the Behaving Rat
Csicsvari, J., Jamieson, B., Wise, K. D., & Buzsáki, G. (2003) · Neuron · doi:10.1016/s0896-6273(02)01169-8 · Cited by 1,001
Self-citationWireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
Self-citationFlexible polyimide-based intracortical electrode arrays with bioactive capability
Rousche, P. J., Pellinen, D. S., Pivin, D. P., Williams, J. C., Vetter, R. J., & Kipke, D. R. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914800 · Cited by 644
Maynard, E. M., Nordhausen, C. T., & Normann, R. A. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(96)95176-0 · Cited by 640
A miniature microelectrode array to monitor the bioelectric activity of cultured cells
THOMASJR, C., SPRINGER, P., LOEB, G., BERWALDNETTER, Y., & OKUN, L. (1972) · Experimental Cell Research · doi:10.1016/0014-4827(72)90481-8 · Cited by 580
An Integrated-Circuit Approach to Extracellular Microelectrodes
Wise, K. D., Angell, J. B., & Starr, A. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502738 · Cited by 544
Self-citationSurface modification of neural recording electrodes with conducting polymer/biomolecule blends
Cui, X., Lee, V. A., Raphael, Y., Wiler, J. A., Hetke, J. F., Anderson, D. J., & Martin, D. C. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200108)56:2<261::aid-jbm1094>3.0.co;2-i · Cited by 530
Chronic Neural Recording Using Silicon-Substrate Microelectrode Arrays Implanted in Cerebral Cortex
Vetter, R. J., Williams, J. C., Hetke, J. F., Nunamaker, E. A., & Kipke, D. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826680 · Cited by 475
Massively Parallel Recording of Unit and Local Field Potentials With Silicon-Based Electrodes
Csicsvari, J., Henze, D. A., Jamieson, B., Harris, K. D., Sirota, A., Barthó, P., Wise, K. D., & Buzsáki, G. (2003) · Journal of Neurophysiology · doi:10.1152/jn.00116.2003 · Cited by 402
Self-citationKipke, D. R., Vetter, R. J., Williams, J. C., & Hetke, J. F. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814443 · Cited by 367
An implantable multielectrode array with on-chip signal processing
Najafi, K., & Wise, K. D. (1986) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1986.1052646 · Cited by 310
Self-citationA three-dimensional neural recording microsystem with implantable data compression circuitry
Olsson, R. H., & Wise, K. D. (2005) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2005.858479 · Cited by 245
Self-citationA high-yield microassembly structure for three-dimensional microelectrode arrays
Bai, Q., Wise, K. D., & Anderson, D. J. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.827288 · Cited by 245
Self-citationA 32-site neural recording probe fabricated by DRIE of SOI substrates
Norlin, P., Kindlundh, M., Mouroux, A., Yoshida, K., & Hofmann, U. G. (2002) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/12/4/312 · Cited by 184
An IC Piezoresistive Pressure Sensor for Biomedical Instrumentation
Samaun, Wise, K. D., & Angell, J. B. (1973) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1973.324170 · Cited by 176
Self-citationA Low-Capacitance Multielectrode Probe for Use in Extracellular Neurophysiology
Wise, K. D., & Angell, J. B. (1975) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1975.324562 · Cited by 157
Self-citationStrength characterization of silicon microprobes in neurophysiological tissues
Najafi, K., & Hetke, J. F. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.55638 · Cited by 146
Kewley, D. T., Hills, M. D., Borkholder, D. A., Opris, I. E., Maluf, N. I., Storment, C. W., Bower, J. M., & Kovacs, G. T. A. (1997) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(97)80221-x · Cited by 119
A micromachined silicon depth probe for multichannel neural recording
Yoon, T. H., Hwang, E. J., Shin, D. Y., Park, S. I., Oh, S. J., Jung, S. C., Shin, H. C., & Kim, S. J. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.855936 · Cited by 110
Thin-Film Multiple Electrode Probes: Possibilities and Limitations
Prohaska, O. J., Olcaytug, F., Pfundner, P., & Dragaun, H. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325894 · Cited by 103
Multisite microprobes for neural recordings
Blum, N. A., Carkhuff, B. G., Charles, H. K., Edwards, R. L., & Meyer, R. A. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.68211 · Cited by 93
High-resolution spatio-temporal mapping of visual pathways using multi-electrode arrays
Normann, R. A., Warren, D. J., Ammermüller, J., Fernández, E., & Guillory, S. G. (2001) · Vision Research · doi:10.1016/s0042-6989(00)00273-x · Cited by 90
Implantable multichannel electrode array based on soi technology
Cheung, K. C., Djupsund, K., Dan, Y., & Lee, L. P. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2003.809962 · Cited by 81
A Practical 24 Channel Microelectrode for Neural Recording in Vivo
Kuperstein, M., & Whittington, D. A. (1981) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1981.324702 · Cited by 72
A Fully Integrated Multisite Pressure Sensor for Wireless Arterial Flow Characterization
DEHENNIS, A. D., & Wise, K. D. (2006) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2006.876668 · Cited by 65
Self-citationGingerich, M. D., Hetke, J. F., Anderson, D. J., & Wise, K. D. (2001) · Springer eBooks · doi:10.1007/978-3-642-59497-7_99 · Cited by 57
Self-citationA fully-integrated bandpass amplifier for extracellular neural recording
Olsson, R. H. I. I. I., Gulari, A. N., & Wise, K. D. (2003) · First International IEEE EMBS Conference on Neural Engineering, 2003. Conference Proceedings. · doi:10.1109/cne.2003.1196783 · Cited by 55
Self-citationLoeb, G. E., Marks, W. B., & Beatty, P. G. (1977) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442964 · Cited by 46
A tantalum-on-sapphire microelectrode array
May, G. A., Shamma, S. A., & White, R. L. (1979) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1979.19798 · Cited by 41
Integrated Electronics for a Reading Aid for the Blind
Brugler, J. S., MEINDL, J. D., Plummer, J. D., Salsbury, P. J., & Young, W. T. (1969) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1969.1050028 · Cited by 34
A shuttered probe with in-line flowmeters for chronic in-vivo drug delivery
Papageorgiou, D., Bledsoe, S. C., Gulari, M., Hetke, J. F., Anderson, D. J., & Wise, K. D. (2002) · Technical Digest. MEMS 2001. 14th IEEE International Conference on Micro Electro Mechanical Systems (Cat. No.01CH37090) · doi:10.1109/memsys.2001.906516 · Cited by 33
Self-citationA three-dimensional neural recording microsystem with implantable data compression circuitry
Olsson, R. H., & Wise, K. D. (2005) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2005.1494117 · Cited by 31
Self-citationMOS electronics for a portable reading aid for the blind
Plummer, J. D., & MEINDL, J. D. (1972) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1972.1050256 · Cited by 28
An Ultra-Thin Hermetic Package Utilizing Electroplated Gold
Stark, B. H., & Najafi, K. (2001) · Springer eBooks · doi:10.1007/978-3-642-59497-7_45 · Cited by 26
Long-term testing of hermetic anodically bonded glass-silicon packages
Harpster, T. J., & Najafi, K. (2003) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2002.984293 · Cited by 25
A WIRELESS MICROSYSTEM FOR MULTICHANNEL NEURAL RECORDING MICROPROBES
Yu, H., Olsson, R. H., Wise, K. D., & Najafi, K. (2004) · Solid-State Sensors, Actuators, and Microsystems Workshop (Hilton Head Workshop) · doi:10.31438/trf.hh2004.31 · Cited by 22
Self-citationIntegrated circuits for a bidirectional implantable pulsed Doppler ultrasonic blood flowmeter
Allen, H. V., Knutti, J. W., & MEINDL, J. D. (1978) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1978.1052060 · Cited by 21
A high-density electrode array for a cochlear prosthesis
Bhatti, P. T., Arcand, B. Y., Wang, J., Butala, N. V., Friedrich, C. R., & Wise, K. D. (2004) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/sensor.2003.1217124 · Cited by 17
Self-citationA FULLY-INTEGRATED MULTI-SITE PRESSURE SENSOR FOR WIRELESS ARTERIAL FLOW CHARACTERIZATION
DEHENNIS, A. D., & Wise, K. D. (2004) · Solid-State Sensors, Actuators, and Microsystems Workshop (Hilton Head Workshop) · doi:10.31438/trf.hh2004.46 · Cited by 17
Self-citationLow power integrated circuits for an implantable pulsed Doppler ultrasonic blood flowmeter
Gill, R. W., & MEINDL, J. D. (1975) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1975.1050642 · Cited by 16
Perlin, G. E., & Wise, K. D. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1403590 · Cited by 11
Self-citationIntegrated signal conditioning for diaphragm pressure sensors
Borky, J. M., & Wise, K. D. (1979) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.1979.1155903 · Cited by 6
Self-citation
Research works printed but not linked: 2
- Wise, 2004, Wireless implantable microsystems: Electronic interface to the nervous system, 76
- 10.31438/trf.hh1994.7 · doi:10.31438/trf.hh1994.7
Cited by
Yuk, H., Lu, B., & Zhao, X. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00595h · Cited by 2,108
Yang, J. C., Mun, J., Kwon, S. Y., Park, S., Bao, Z., & Park, S. (2019) · Advanced Materials · doi:10.1002/adma.201904765 · Cited by 1,641
Neural recording and modulation technologies
Chen, R., Canales, A., & Anikeeva, P. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.93 · Cited by 655
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
A Review of Organic and Inorganic Biomaterials for Neural Interfaces
Fattahi, P., Yang, G., Kim, G., & Abidian, M. R. (2014) · Advanced Materials · doi:10.1002/adma.201304496 · Cited by 580
Metadata
- Authors
- Wise, K. D.
- Affiliations
- University of Michigan (US)
- Corresponding author
- Wise, K.D.
- Venue
- IEEE Engineering in Medicine and Biology Magazine
- Published
- 2005-09
- Volume
- 24
- Issue
- 5
- Pages
- 22-29
- ISSN
- 0739-5175 (ISSN-L)
- OpenAlex
- W2169061869
- Semantic Scholar
- 67dd8cfcba93c21d7e050f08dabffe34c5e970cc
- Cited by
- 194
- References
- 44
- Citations by year
- 2026: 4 · 2025: 9 · 2024: 3 · 2023: 8 · 2022: 4 · 2021: 6 · 2020: 12 · 2019: 9 · 2018: 10 · 2017: 16 · 2016: 8 · 2015: 8 · 2014: 14 · 2013: 5 · 2012: 17
- FWCI
- 0.77
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Engineering in Medicine and Biology Magazine (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute of Neurological Disorders and Stroke (N01-NS-4-2363)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced MEMS and NEMS Technologies
- Keywords
- silicon microsystems, neural prostheses, neural recording, neurostimulation, microelectrode arrays, single-unit recording, silicon-on-insulator, on-chip signal processing, wireless neural interface, brain mapping, electrode-tissue interface, chronic implantation
- MeSH terms
- Artificial Intelligence, Electrodes, Implanted, Electronics, Electric Stimulation Therapy, Equipment Design, Humans, Microelectrodes, Miniaturization, Nervous System Diseases, Neurosciences, Silicon, Therapy, Computer-Assisted, Equipment Failure Analysis, Prostheses and Implants, Biomimetics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.