Implantable biomedical microsystems for neural prostheses
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
In the following article, the technologies to fabricate polyimide-based thin and flexible substrates with monolithically integrated electrode arrays and printed circuit boards (PCB) for hybrid electronic assemblies as well as an assembling technique that connects bare electronic dice with flexible PCBs are presented. The concept of modular, flexible biomedical microsystems as neural prostheses is introduced in general and described in detail in three examples. A cuff electrode with integrated multiplexer circuitry and standard implantable cables represents the combination of microtechnology with precision mechanics; a sieve electrode used as an implant in peripheral nerve regeneration studies demonstrates the next level of integration density but still uses a cable connection; and last, joint effort to fabricate the demonstrator of a vision prosthesis that is completely implantable in the eye with a wireless link for energy supply and data transmission is presented. System design, hybrid assembling technology, and flexible multilayer encapsulation using parylene and silicone rubber are the key components for creating a new generation of neural prostheses for complex and challenging new applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Flexible polyimide-based intracortical electrode arrays with bioactive capability
Rousche, P. J., Pellinen, D. S., Pivin, D. P., Williams, J. C., Vetter, R. J., & Kipke, D. R. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914800 · Cited by 644
Micromachined, Polyimide-Based Devices for Flexible Neural Interfaces
Stieglitz, T., Beutel, H., Schuettler, M., & Meyer, J.-U. (2000) · Biomedical Microdevices · doi:10.1023/a:1009955222114 · Cited by 343 · cited 2×
“We have chosen polyimide as the material for several reasons [16].”
BackgroundMethodSelf-citationSelective Electrical Interfaces with the Nervous System
Rutten, W. L. C. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.020702.153427 · Cited by 276 · cited 4×
“Presently, silicon-based microsystems have been established as a research tool in the neurosciences to investigate the CNS [1]–[3].”
BackgroundInfluentialPolyimide cuff electrodes for peripheral nerve stimulation
Rodri´guez, F. J., Ceballos, D., Schu¨ttler, M., Valero, A., Valderrama, E., Stieglitz, T., & Navarro, X. (2000) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(00)00192-8 · Cited by 207 · cited 1×
“Our group developed small polyimide-based micromachined cuff electrodes with up to 12 electrode sites that revealed excellent results in chronic studies on the peripheral nerve [21].”
Self-citationLago, N., Ceballos, D., J Rodrı́guez, F., Stieglitz, T., & Navarro, X. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.06.025 · Cited by 178 · cited 1×
“However, in a few cases, a decline of target reinnervation and a loss of regenerated nerve fibers were found between six months and 12 months postimplantation [24].”
BackgroundSelf-citationImplantable bioelectronic interfaces for lost nerve functions
Heiduschka, P., & Thanos, S. (1998) · Progress in Neurobiology · doi:10.1016/s0301-0082(98)00013-6 · Cited by 126
Judson, J. P. (1968) · JAMA · doi:10.1001/jama.1968.03140120031007 · Cited by 103
Klinge, P. M., Vafa, M. A., Brinker, T., Brandis, A., Walter, G. F., Stieglitz, T., Samii, M., & Wewetzer, K. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00420-8 · Cited by 64
Self-citationStieglitz, T. (2004) · Journal of Nanoscience and Nanotechnology · doi:10.1166/jnn.2004.075 · Cited by 30
Self-citation
Cited by
A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve
Boretius, T., Badia, J., Pascual-Font, A., Schuettler, M., Navarro, X., Yoshida, K., & Stieglitz, T. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.05.010 · Cited by 468
Self-citationControl of Hand Prostheses Using Peripheral Information
Micera, S., Carpaneto, J., & Raspopovic, S. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2085429 · Cited by 403
Double nerve intraneural interface implant on a human amputee for robotic hand control
Rossini, P. M., Micera, S., Benvenuto, A., Carpaneto, J., Cavallo, G., Citi, L., Cipriani, C., Denaro, L., Denaro, V., Di Pino, G., et al. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.001 · Cited by 396
Mazzatenta, A., Giugliano, M., Campidelli, S., Gambazzi, L., Businaro, L., Markram, H., Prato, M., & Ballerini, L. (2007) · Journal of Neuroscience · doi:10.1523/jneurosci.1051-07.2007 · Cited by 349
Tools for Probing Local Circuits: High-Density Silicon Probes Combined with Optogenetics
Buzsáki, G., Stark, E., Berényi, A., Khodagholy, D., Kipke, D. R., Yoon, E., & Wise, K. D. (2015) · Neuron · doi:10.1016/j.neuron.2015.01.028 · Cited by 334
Metadata
- Authors
- Stieglitz, T., Schuetter, M., & Koch, K. P.
- Venue
- IEEE Engineering in Medicine and Biology Magazine
- Published
- 2005-09
- Volume
- 24
- Issue
- 5
- Pages
- 58-65
- ISSN
- 0739-5175 (ISSN-L)
- OpenAlex
- W2028540625
- Cited by
- 140
- References
- 9
- FWCI
- 3.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Implantable biomedical microsystems for neural prostheses. https://app.cochat.ai/papers/10.1109/memb.2005.1511501
- The paper
- Stieglitz, T., Schuetter, M., & Koch, K. P. (2005). Implantable biomedical microsystems for neural prostheses. IEEE Engineering in Medicine and Biology Magazine. https://doi.org/10.1109/memb.2005.1511501
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.