Sensors for brain-computer interfaces
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Brain-computer interfaces (BCIs) hold the promise to restore mobility and independence to persons with paralysis. In spinal cord injury, brainstem stroke, and a host of neuromuscular disorders, the intact brain is "disconnected" from its intact target (such as a limb or the facial musculature), preventing mobility and - in locked-in syndrome and severe amyotrophic lateral sclerosis (ALS) - precluding even meaningful verbal communication. If it becomes possible to discern the movement intention of someone with paralysis - reliably, safely, and in real time - it would then be possible to provide not only a robust new method of communication but eventually the ability to gain control over a prosthetic limb or, by connecting to additional technologies, one's own limbs. In this review, we survey several methods for revealing neural activity in the human brain and their potential for re-enabling mobility in persons with severe paralysis
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228 · cited 1×
“Despite the limitations imposed by the typically very small signal-to-noise ratios (SNR)—mainly slow speed resulting from the need for repeated illumination of both incorrect and correct letters until the stimulus-triggered P300 signal reaches statistical significance—this system has the distinct advantage over EEGMOD…”
BackgroundTargeting Recovery: Priorities of the Spinal Cord-Injured Population
Anderson, K. D. (2004) · Journal of Neurotrauma · doi:10.1089/neu.2004.21.1371 · Cited by 2,094 · cited 1×
“Efforts should be made to develop BCIs for which training is relatively rapid and acceptable to users [68].”
BackgroundControl of a two-dimensional movement signal by a noninvasive brain-computer interface in humans
Wolpaw, J. R., & McFarland, D. J. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0403504101 · Cited by 1,512
Cognitive Control Signals for Neural Prosthetics
Musallam, S., Corneil, B. D., Greger, B., Scherberger, H., & Andersen, R. A. (2004) · Science · doi:10.1126/science.1097938 · Cited by 663
Wireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
Imaging brain plasticity during motor skill learning
Ungerleider, L. (2002) · Neurobiology of Learning and Memory · doi:10.1006/nlme.2002.4091 · Cited by 641 · cited 1×
“This technique, which measures the delayed local hemodynamic response to neural activity (believed to be the result primarily of changes in local field potentials [2]), has been used to explore cortical and subcortical structures involved in voluntary movement and motor learning [3]–[6].”
MethodMaynard, E. M., Nordhausen, C. T., & Normann, R. A. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(96)95176-0 · Cited by 640 · cited 3×
“Based upon work conducted in the Donoghue laboratory [46], [55], and following eight years of device development and testing in monkeys, a 4 mm × 4 mm sensory (array) of 100 silicon microelectrodes ([35], Cyberkinetics, Inc.”
BackgroundMethodPfurtscheller, G., Müller, G. R., Pfurtscheller, J., Gerner, H. J., & Rupp, R. (2003) · Neuroscience Letters · doi:10.1016/s0304-3940(03)00947-9 · Cited by 548
The thought translation device (TTD) for completely paralyzed patients
Birbaumer, N., Kubler, A., Ghanayim, N., Hinterberger, T., Perelmouter, J., Kaiser, J., Iversen, I., Kotchoubey, B., Neumann, N., & Flor, H. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847812 · Cited by 493
Brain oscillations control hand orthosis in a tetraplegic
Pfurtscheller, G., Guger, C., Müller, G., Krausz, G., & Neuper, C. (2000) · Neuroscience Letters · doi:10.1016/s0304-3940(00)01471-3 · Cited by 472
Suner, S., Fellows, M. R., Vargas-Irwin, C., Nakata, G. K., & Donoghue, J. P. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.857687 · Cited by 415 · cited 1×
“While certain electrodes have been shown to record for years in nonhuman primates [65], longevity will be an ongoing issue, as electrodes appear to generate varying degrees of intracortical and meningeal tissue reaction, which may or may not significantly interfere with recording over time, especially if they must fun…”
BackgroundSelf-citationMassively Parallel Recording of Unit and Local Field Potentials With Silicon-Based Electrodes
Csicsvari, J., Henze, D. A., Jamieson, B., Harris, K. D., Sirota, A., Barthó, P., Wise, K. D., & Buzsáki, G. (2003) · Journal of Neurophysiology · doi:10.1152/jn.00116.2003 · Cited by 402
Kennedy, P. R. (1989) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(89)90142-8 · Cited by 151 · cited 1×
“Clinical Trials of Intracortical BCIs The first type of intracortical BCI (iBCI) implanted into humans was the “cone”—or “neurotrophic”—electrode, which contains two electrode wires in a glass enclosure [51].”
Cited by
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Self-citationBrain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
FMRI brain-computer interface: a tool for neuroscientific research and treatment.
Sitaram, R., Caria, A., Veit, R., Gaber, T., Rota, G., Kuebler, A., & Birbaumer, N. (2007) · Computational Intelligence and Neuroscience · doi:10.1155/2007/25487 · Cited by 233
Barrese, J. C., Aceros, J., & Donoghue, J. P. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/026003 · Cited by 161
“In order to capture sufficient neural data, intracortical microelectrode arrays (MEA's) capable of recording single-unit activity are often the sensor of choice [1].”
BackgroundSelf-citationByun, D., Cho, S. J., & Kim, S. (2013) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/23/12/125010 · Cited by 39
Metadata
- Authors
- Hochberg, L. R., & Donoghue, J. P.
- Venue
- IEEE Engineering in Medicine and Biology Magazine
- Published
- 2006-09
- Volume
- 25
- Issue
- 5
- Pages
- 32-38
- ISSN
- 0739-5175 (ISSN-L)
- OpenAlex
- W2119774068
- Cited by
- 115
- References
- 13
- FWCI
- 2.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.