Scanning electron microscopy of chronically implanted intracortical microelectrode arrays in non-human primates
Open accessAbstract
OBJECTIVE: Signal attenuation is a major problem facing intracortical sensors for chronic neuroprosthetic applications. Many studies suggest that failure is due to gliosis around the electrode tips, however, mechanical and material causes of failure are often overlooked. The purpose of this study was to investigate the factors contributing to progressive signal decline by using scanning electron microscopy (SEM) to visualize structural changes in chronically implanted arrays and histology to examine the tissue response at corresponding implant sites. APPROACH: We examined eight chronically implanted intracortical microelectrode arrays (MEAs) explanted from non-human primates at times ranging from 37 to 1051 days post-implant. We used SEM, in vivo neural recordings, and histology (GFAP, Iba-1, NeuN). Three MEAs that were never implanted were also imaged as controls. MAIN RESULTS: SEM revealed progressive corrosion of the platinum electrode tips and changes to the underlying silicon. The parylene insulation was prone to cracking and delamination, and in some instances the silicone elastomer also delaminated from the edges of the MEA. Substantial tissue encapsulation was observed and was often seen growing into defects in the platinum and parylene. These material defects became more common as the time in vivo increased. Histology at 37 and 1051 days post-implant showed gliosis, disruption of normal cortical architecture with minimal neuronal loss, and high Iba-1 reactivity, especially within the arachnoid and dura. Electrode tracts were either absent or barely visible in the cortex at 1051 days, but were seen in the fibrotic encapsulation material suggesting that the MEAs were lifted out of the brain. Neural recordings showed a progressive drop in impedance, signal amplitude, and viable channels over time. SIGNIFICANCE: These results provide evidence that signal loss in MEAs is truly multifactorial. Gliosis occurs in the first few months after implantation but does not prevent useful recordings for several years. Progressive meningeal fibrosis encapsulates and lifts MEAs out of the cortex while ongoing foreign body reactions lead to progressive degradation of the materials. Long-term impedance drops are due to the corrosion of platinum, cracking and delamination of parylene, and delamination of silicone elastomer. Oxygen radicals released by cells of the immune system likely mediate the degradation of these materials. Future MEA designs must address these problems through more durable insulation materials, more inert electrode alloys, and pharmacologic suppression of fibroblasts and leukocytes.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the CNS, 90% of Utah arrays implanted in non-human primates failed over a 6 year chronic implantation period, with most failures seen within a year of implantation.
“In the CNS, a tissue less exposed to movement than peripheral nerves, a study determined that 90% of Utah arrays implanted in non-human primates failed over a 6 year chronic implantation period, with most of failures seen within a year of implantation (Barrese et al., 2016).”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Barrese et al., 2016
Materials and methods reports eight arrays implanted for 37–1051 days, not a six-year observation period. Results §3.7–3.8 say two arrays worked until they were removed at 994 days for other experiments, contrary to the claim that most failed within a year. The paper does not report the claimed 90% failure rate. (LLM, conf=0.86)
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredAs implants fail to move together with tissue, compression and sliding along the interface cause damage to surrounding tissue.
“As implants fail to move together with tissue, the compression and sliding along the interface causes damage to the surrounding tissue (Goldstein and Salcman, 1973; Sharp et al., 2009; Barrese et al., 2016).”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Barrese et al., 2016
The Introduction and Discussion §4.1 describe meningeal fibrosis lifting arrays out of the cortex and contributing to recording failure. Discussion §4.3 says mechanical failure modes were not clearly observed. Neither those passages nor the additional searches for compression, sliding, and relative implant–tissue movement address the claimed mechanism of damage to surrounding tissue. (LLM, conf=0.76)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295 · see citing works
Self-citationReach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719 · see citing works
Self-citationResponse of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896 · see citing works
Large-scale recording of neuronal ensembles
Buzsáki, G. (2004) · Nature Neuroscience · doi:10.1038/nn1233 · Cited by 1,875 · see citing works
High-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848 · see citing works
The glial scar and central nervous system repair
Fawcett, J. W., & Asher, R. A. (1999) · Brain Research Bulletin · doi:10.1016/s0361-9230(99)00072-6 · Cited by 1,808 · see citing works
Real-time control of a robot arm using simultaneously recorded neurons in the motor cortex
Chapin, J. K., Moxon, K. A., Markowitz, R. S., & Nicolelis, M. A. L. (1999) · Nature Neuroscience · doi:10.1038/10223 · Cited by 1,168 · see citing works
Intracellular Features Predicted by Extracellular Recordings in the Hippocampus In Vivo
Henze, D. A., Borhegyi, Z., Csicsvari, J., Mamiya, A., Harris, K. D., & Buzsáki, G. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.84.1.390 · Cited by 942 · see citing works
Biran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893 · see citing works
Connecting cortex to machines: recent advances in brain interfaces
Donoghue, J. P. (2002) · Nature Neuroscience · doi:10.1038/nn947 · Cited by 720 · see citing works
Self-citationChronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
Rousche, P. J., & Normann, R. A. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00031-4 · Cited by 646 · see citing works
Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates
Barrese, J. C., Rao, N., Paroo, K., Triebwasser, C., Vargas-Irwin, C., Franquemont, L., & Donoghue, J. P. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/6/066014 · Cited by 600 · see citing works
Self-citationCerebral Astrocyte Response to Micromachined Silicon Implants
Turner, J. N., Shain, W. G., Szarowski, D. H., Andersen, M., Martins, S., Isaacson, M. S., & Craighead, H. G. (1999) · Experimental Neurology · doi:10.1006/exnr.1998.6983 · Cited by 593 · see citing works
In vivo studies of polypyrrole/peptide coated neural probes
Cui, X. T. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00415-5 · Cited by 505 · see citing works
Wang, J., Marković, N. M., & Adžić, R. R. (2004) · The Journal of Physical Chemistry B · doi:10.1021/jp037593v · Cited by 499 · see citing works
Chronic Neural Recording Using Silicon-Substrate Microelectrode Arrays Implanted in Cerebral Cortex
Vetter, R. J., Williams, J. C., Hetke, J. F., Nunamaker, E. A., & Kipke, D. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826680 · Cited by 477 · see citing works
Suner, S., Fellows, M. R., Vargas-Irwin, C., Nakata, G. K., & Donoghue, J. P. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.857687 · Cited by 415 · see citing works
Self-citationKim, S.-P., Simeral, J. D., Hochberg, L. R., Donoghue, J. P., & Black, M. J. (2008) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/4/010 · Cited by 399 · see citing works
Self-citationComplex impedance spectroscopy for monitoring tissue responses to inserted neural implants
Williams, J. C., Hippensteel, J. A., Dilgen, J., Shain, W. G., & Kipke, D. R. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/4/007 · Cited by 399 · see citing works
Progress towards biocompatible intracortical microelectrodes for neural interfacing applications
Jorfi, M., Skousen, J. L., Weder, C., & Capadona, J. R. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/011001 · Cited by 384 · see citing works
Katsounaros, I., Schneider, W. B., Meier, J. C., Benedikt, U., Biedermann, P. U., Auer, A. A., & Mayrhofer, K. J. J. (2012) · Physical Chemistry Chemical Physics · doi:10.1039/c2cp40616k · Cited by 376 · see citing works
Drake, K. L., Wise, K. D., Farraye, J., Anderson, D. J., & BeMent, S. L. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.7273 · Cited by 364 · see citing works
Kipke, D. R., Vetter, R. J., Williams, J. C., & Hetke, J. F. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814443 · Cited by 364 · see citing works
Chestek, C. A., Gilja, V., Nuyujukian, P., Foster, J. D., Fan, J. M., Kaufman, M. T., Churchland, M. M., Rivera-Alvidrez, Z., Cunningham, J. P., Ryu, S. I., et al. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/045005 · Cited by 350 · see citing works
Biran, R., Martin, D. C., & Tresco, P. A. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31138 · Cited by 336 · see citing works
A method for pneumatically inserting an array of penetrating electrodes into cortical tissue
Rousche, P. J., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368133 · Cited by 305 · see citing works
Prasad, A., Xue, Q.-S., Sankar, V., Nishida, T., Shaw, G., Streit, W. J., & Sanchez, J. C. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/5/056015 · Cited by 298 · see citing works
Liu, X., McCreery, D. B., Carter, R. R., Bullara, L. A., Yuen, T. G. H., & Agnew, W. F. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.788468 · Cited by 272 · see citing works
The CNS lesion scar: new vistas on an old regeneration barrier
Stichel, C. C., & Müller, H. W. (1998) · Cell and Tissue Research · doi:10.1007/s004410051151 · Cited by 264 · see citing works
Parylene as a Chronically Stable, Reproducible Microelectrode Insulator
Loeb, G. E., Bak, M. J., Salcman, M., & Schmidt, E. M. (1977) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1977.326115 · Cited by 258 · see citing works
Long-term implants of Parylene-C coated microelectrodes
Schmidt, E., Mcintosh, J. S., & Bak, M. (2006) · Medical and Biological Engineering and Computing · doi:10.1007/bf02441836 · Cited by 216 · see citing works
Chronic response of adult rat brain tissue to implants anchored to the skull
Kim, Y. T., Hitchcock, R. W., Bridge, M. J., & Tresco, P. A. (2003) · Biomaterials · doi:10.1016/j.biomaterials.2003.09.010 · Cited by 214 · see citing works
Diffusion barriers evoked in the rat cortex by reactive astrogliosis
Roitbak, T., & Sykov�, E. (1999) · Glia · doi:10.1002/(sici)1098-1136(199910)28:1 · Cited by 208 · see citing works
Donoghue, J. P., Nurmikko, A. V., Black, M. J., & Hochberg, L. R. (2007) · The Journal of Physiology · doi:10.1113/jphysiol.2006.127209 · Cited by 197 · see citing works
Self-citationNervous system proteoglycans as modulators of neurite outgrowth
Bovolenta, P., & Fernaud-Espinosa, I. (2000) · Progress in Neurobiology · doi:10.1016/s0301-0082(99)00044-1 · Cited by 189 · see citing works
Implant Size and Fixation Mode Strongly Influence Tissue Reactions in the CNS
Thelin, J., Jörntell, H., Psouni, E., Garwicz, M., Schouenborg, J., Danielsen, N., & Linsmeier, C. E. (2011) · PLoS ONE · doi:10.1371/journal.pone.0016267 · Cited by 188 · see citing works
Biocompatibility of silicon‐based electrode arrays implanted in feline cortical tissue
Schmidt, S., Horch, K., & Normann, R. A. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820271106 · Cited by 182 · see citing works
Winslow, B. D., Christensen, M. B., Yang, W.-K., Solzbacher, F., & Tresco, P. A. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.05.050 · Cited by 171 · see citing works
The astrocyte/meningeal cell interface – a barrier to successful nerve regeneration?
Shearer, M. C., & Fawcett, J. W. (2001) · Cell and Tissue Research · doi:10.1007/s004410100384 · Cited by 162 · see citing works
Biocompatibility of intracortical microelectrodes: current status and future prospects
Marin, C. (2010) · Frontier in Neuroengineering · doi:10.3389/fneng.2010.00008 · Cited by 160 · see citing works
Glucose and Mannitol Diffusion in Human Dura Mater
Bashkatov, A. N., Genina, E. A., Sinichkin, Y. P., Kochubey, V. I., Lakodina, N. A., & Tuchin, V. V. (2003) · Biophysical Journal · doi:10.1016/s0006-3495(03)74750-x · Cited by 159 · see citing works
The origin ofsubdural neomembranes. II. Fine structural of neomembranes.
Friede, R. L., & Schachenmayr, W. (1978) · PubMed Central · Cited by 157 · see citing works
Quantifying long-term microelectrode array functionality using chronic in vivo impedance testing
Prasad, A., & Sanchez, J. C. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/2/026028 · Cited by 157 · see citing works
The insulation performance of reactive parylene films in implantable electronic devices
Seymour, J. P., Elkasabi, Y. M., Chen, H.-Y., Lahann, J., & Kipke, D. R. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.07.061 · Cited by 147 · see citing works
Griffith, R. W., & Humphrey, D. R. (2006) · Neuroscience Letters · doi:10.1016/j.neulet.2006.07.018 · Cited by 147 · see citing works
In Vivo Electrical Impedance Spectroscopy of Tissue Reaction to Microelectrode Arrays
Mercanzini, A., Colin, P., Bensadoun, J., Bertsch, A., & Renaud, P. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2018457 · Cited by 130 · see citing works
Negi, S., Bhandari, R., Rieth, L. W., Wagenen, R. V., & Solzbacher, F. (2009) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.10.016 · Cited by 127 · see citing works
Electrical stimulation with Pt electrodes. V. The effect of protein on Pt dissolution
Robblee, L. S., McHardy, J., Marston, J. M., & Brummer, S. B. (1980) · Biomaterials · doi:10.1016/0142-9612(80)90035-6 · Cited by 117 · see citing works
Sensors for brain-computer interfaces
Hochberg, L. R., & Donoghue, J. P. (2006) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2006.1705745 · Cited by 116 · see citing works
Self-citationBrummer, S. B., McHardy, J., & Turner, M. J. (2008) · Brain Behavior and Evolution · doi:10.1159/000124611 · Cited by 106 · see citing works
Robblee, L. S., McHardy, J., Agnew, W. F., & Bullara, L. A. (1983) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(83)90062-6 · Cited by 95 · see citing works
McHardy, J., Robblee, L. S., Marston, J. M., & Brummer, S. B. (1980) · Biomaterials · doi:10.1016/0142-9612(80)90034-4 · Cited by 91 · see citing works
New perspectives in the microscopic structure of human dura mater in the dorsolumbar region
Reina, M. Á., Dittmann, M. T., GARCIA, A., et al. (1997) · Regional Anesthesia & Pain Medicine · doi:10.1016/s1098-7339(06)80036-2 · Cited by 82 · see citing works
Impedance Characterization of Microarray Recording Electrodes in Vitro
Merrill, D. R., & Tresco, P. A. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.856245 · Cited by 74 · see citing works
Seven years of recording from monkey cortex with a chronically implanted multiple microelectrode
Krüger, J. (2010) · Frontiers in Neuroengineering · doi:10.3389/fneng.2010.00006 · Cited by 73 · see citing works
Histopathological Changes Produced by Implanted Electrodes in Cat Brains
Collias, J. C., & Manuelidis, E. E. (1957) · Journal of neurosurgery · doi:10.3171/jns.1957.14.3.0302 · Cited by 68 · see citing works
The influence of thermal history on structure and water transport in Parylene C coatings
Davis, E. M., Benetatos, N. M., Regnault, W. F., Winey, K. I., & Elabd, Y. A. (2011) · Polymer · doi:10.1016/j.polymer.2011.08.010 · Cited by 68 · see citing works
Electrochemical corrosion of platinum electrode in concentrated sulfuric acid
Kodera, F., Kuwahara, Y., Nakazawa, A., et al. (2007) · Journal of Power Sources · doi:10.1016/j.jpowsour.2007.05.016 · Cited by 67 · see citing works
The ultrastructure of the sheath around chronically implanted electrodes in brain
Schultz, R. L., & Willey, T. J. (1976) · Journal of Neurocytology · doi:10.1007/bf01181577 · Cited by 63 · see citing works
A High-Performance Keyboard Neural Prosthesis Enabled by Task Optimization
Nuyujukian, P., Fan, J. M., Kao, J. C., Ryu, S. I., & Shenoy, K. V. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2354697 · Cited by 61 · see citing works
Recording for several days from single cortical neurons in completely unrestrained cats
Burns, B. D., Stean, J. P. B., & Webb, A. C. (1974) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(74)90175-8 · Cited by 56 · see citing works
Gencoglu, A., & Minerick, A. R. (2009) · Lab on a Chip · doi:10.1039/b820126a · Cited by 47 · see citing works
Human fibroblast attachment on fibrous parylene-C thin-film substrates
Wei, L., Lakhtakia, A., Roopnariane, A., & Ritty, T. M. (2010) · Materials Science and Engineering C · doi:10.1016/j.msec.2010.07.003 · Cited by 46 · see citing works
Electrochemical Corrosion of Platinum in Hydrochloric Acid Solutions
Llopis, J., & Sancho, A. (1961) · Journal of The Electrochemical Society · doi:10.1149/1.2428205 · Cited by 46 · see citing works
A comparison of neuroinflammation to implanted microelectrodes in rat and mouse models
Potter–Baker, K. A., Ravikumar, M., Burke, A., Meador, W. D., Householder, K. T., Buck, A. C., Sunil, S., Stewart, W. G., Anna, J. P., Tomaszewski, W. H., et al. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.03.076 · Cited by 45 · see citing works
Cogan, S. F., Ehrlich, J., Plante, T. D., Gingerich, M. D., & Shire, D. B. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2050690 · Cited by 35 · see citing works
A brain machine interface control algorithm designed from a feedback control perspective
Gilja, V., Nuyujukian, P., Chestek, C. A., Cunningham, J. P., Yu, B. M., Fan, J. M., Ryu, S. I., & Shenoy, K. V. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346180 · Cited by 26 · see citing works
Neue Ergebnisse bei der Darstellung der Dura mater spinalis mittels Rasterelektronenmikroskopie
Dittmann, M., Reina, M. Á., & García, A. L. (1998) · Der Anaesthesist · doi:10.1007/s001010050578 · Cited by 24 · see citing works
A technique for long term recording from single neurons in unrestrained behaving animals
Fontani, G. (1981) · Physiology & Behavior · doi:10.1016/0031-9384(81)90032-9 · Cited by 21 · see citing works
Beshchasna, N., Adolphi, B., Granovsky, S., et al. (2010) · 2022 IEEE 72nd Electronic Components and Technology Conference (ECTC) · doi:10.1109/ectc.2010.5490711 · Cited by 18 · see citing works
Mioche, L., & Singer, W. (1988) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(88)90131-8 · Cited by 16 · see citing works
Estimation of the cortical connectivity patterns during the intention of limb movements
Astolfi, L., Cincotti, F., Mattia, D., Fallani, F. D. V., Salinari, S., Ursino, M., Zavaglia, M., Marciani, M. G., & Babiloni, F. (2006) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2006.1657785 · Cited by 16 · see citing works
Reina, M. Á., López-García, A., Dittmann, M. T., et al. (1996) · PubMed · Cited by 16 · see citing works
Shepherd, B. K., & Clark, G. M. (1991) · Biomaterials · doi:10.1016/0142-9612(91)90011-x · Cited by 15 · see citing works
Life of Pt and Pt−Ir stimulating electrodes in neurological prostheses
Donaldson, P. E. K., Donaldson, N., & Brindley, G. S. (1985) · Medical & Biological Engineering & Computing · doi:10.1007/bf02444034 · Cited by 14 · see citing works
Palmer, C. L. (1976) · PubMed · Cited by 3 · see citing works
Flagged first, then by citations
Research works printed but not linked: 2
- [71]Darling AS Iridium platinum alloys—a critical review of their constitution and properties Platinum Met. Rev 1960 4 18 26
- [73]Stark N Literature review: biological safety of parylene C Med. Plast. Biomater 1996
Cited by
Sorted by citations
Materials and technologies for soft implantable neuroprostheses
Lacour, S. P., Courtine, G., & Guck, J. (2016) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.63 · Cited by 738 · see citing works
Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics
Carnicer-Lombarte, A., Chen, S.-T., Malliaras, G. G., & Barone, D. G. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.622524 · Cited by 454 · see citing works
A Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389 · see citing works
High‐Density Stretchable Electrode Grids for Chronic Neural Recording
Tybrandt, K., Khodagholy, D., Dielacher, B., Stauffer, F., Renz, A. F., Buzsáki, G., & Vörös, J. (2018) · Advanced Materials · doi:10.1002/adma.201706520 · Cited by 286 · see citing works
The Future of Neuroimplantable Devices: A Materials Science and Regulatory Perspective
Obidin, N., Tasnim, F., & Dagdeviren, C. (2020) · Advanced Materials · doi:10.1002/adma.201901482 · Cited by 126 · see citing works
Explant Analysis of Utah Electrode Arrays Implanted in Human Cortex for Brain-Computer-Interfaces
Woeppel, K., Hughes, C., Herrera, A. J., Eles, J. R., Tyler-Kabara, E. C., Gaunt, R. A., Collinger, J. L., & Cui, X. T. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.759711 · Cited by 90 · see citing works
Amorphous silicon carbide ultramicroelectrode arrays for neural stimulation and recording
Deku, F., Cohen, Y., Joshi-Imre, A., Kanneganti, A., Gardner, T. J., & Cogan, S. F. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa8f8b · Cited by 89 · see citing works
Bullard, A. J., Hutchison, B. C., Lee, J., Chestek, C. A., & Patil, P. G. (2020) · Neuromodulation: Technology at the Neural Interface · doi:10.1111/ner.13069 · Cited by 65 · see citing works
Long-term recording reliability of liquid crystal polymer <i>µ</i> ECoG arrays
Woods, V., Trumpis, M., Bent, B., Palopoli-Trojani, K., Chiang, C.-H., Wang, C., Yu, C., Insanally, M. N., Froemke, R. C., & Viventi, J. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aae39d · Cited by 63 · see citing works
Čvančara, P., Boretius, T., López-Álvarez, V. M., Maciejasz, P., Andreu, D., Raspopovic, S., Petrini, F., Micera, S., Granata, G., Fernandez, E., et al. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab9a9a · Cited by 58 · see citing works
Patel, P. R., Welle, E. J., Letner, J. G., Shen, H., Bullard, A. J., Caldwell, C. M., Vega-Medina, A., Richie, J. M., Thayer, H. E., Patil, P. G., et al. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/acab86 · Cited by 49 · see citing works
Rosenfeld, J. V., Wong, Y. T., Yan, E., Szlawski, J., Mohan, A., Clark, J. C., Rosa, M., & Lowery, A. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab9e1c · Cited by 35 · see citing works
From softening polymers to multimaterial based bioelectronic devices
Ecker, M., Joshi-Imre, A., Modi, R., Frewin, C. L., Garcia-Sandoval, A., Maeng, J., Gutierrez-Heredia, G., Pancrazio, J. J., & Voit, W. E. (2019) · Multifunctional Materials · doi:10.1088/2399-7532/aaed58 · Cited by 34 · see citing works
Lamont, C., Grego, T., Nanbakhsh, K., Shah Idil, A., Giagka, V, Vanhoestenberghe, A., Cogan, S., & Donaldson, N. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abf0d6 · Cited by 28 · see citing works
Implantable Device Fabrication and Packaging
Stieglitz, T. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_102 · Cited by 7 · see citing works
- Authors
- Barrese, J. C., Aceros, J., & Donoghue, J. P.
- Affiliations
- Rutgers, The State University of New Jersey (US)
- University of North Florida (US)
- Brown University (US)
- Corresponding author
- Barrese, James C
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2016-01-29
- Volume
- 13
- Issue
- 2
- Pages
- 026003
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- PMC
- PMC4854331
- OpenAlex
- W2256612106
- Cited by
- 161
- References
- 76
- Citations by year
- 2026: 10 · 2025: 13 · 2024: 12 · 2023: 17 · 2022: 9 · 2021: 25 · 2020: 16 · 2019: 14 · 2018: 22 · 2017: 15 · 2016: 8
- FWCI
- 11.07
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institute of Neurological Disorders and Stroke (R01NS025074)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Neurology › Neurological disorders and treatments
- Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- intracortical microelectrode arrays, signal attenuation, meningeal fibrosis, gliosis, foreign body reaction, electrode encapsulation, non-human primates, oxygen free radicals
- MeSH terms
- Animals, Electrodes, Implanted, Equipment Design, Female, Macaca mulatta, Male, Microelectrodes, Microscopy, Electron, Scanning, Motor Cortex, Primates
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review