A shuttered probe with in-line flowmeters for chronic in-vivo drug delivery
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
This paper describes a micromachined microprobe for in-vivo drug delivery at the cellular level. The probe was developed to support research in neuropharmacology as well as for eventual use in neural prostheses. Extending a standard process for the realization of electrical recording and stimulating probes, the drug delivery probe adds microchannels, fluidic cables, dielectric shutters over the injecting orifices, and in-line flowmeters to verify the intended dose. These fluidic components require three masks in addition to the normal probe process. The fluidic cables are 1.5X more flexible than the polyimide tubing formerly used and can be integrated with the probes, while the shutters reduce the unintended delivery of drugs into tissue by a factor of 25 compared with an open orifice. The flowmeter operates in pulsed mode as a hot wire anemometer, with a power dissipation of 1.5 mW and a flow resolution of about 150 pL/sec. The temperature rise in tissue near the flowmeter is less than 1/spl deg/C. Process compatibility with on-chip microvalve and micropump structures has also been explored.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A high-yield microassembly structure for three-dimensional microelectrode arrays
Bai, Q., Wise, K. D., & Anderson, D. J. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.827288 · Cited by 245
Self-citationSilicon ribbon cables for chronically implantable microelectrode arrays
Hetke, J. F., Lund, J. L., Najafi, K., Wise, K. D., & Anderson, D. J. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.284959 · Cited by 174
Self-citationA wireless single-chip telemetry-powered neural stimulation system
Von Arx, J. A., & Najafi, K. (2003) · 1999 IEEE International Solid-State Circuits Conference. Digest of Technical Papers. ISSCC. First Edition (Cat. No.99CH36278) · doi:10.1109/isscc.1999.759199 · Cited by 74 · cited 1×
“The fluidic cables were compared experimentally to typical e1ectric:al ribbon cables [5] and to 70pm-diameter polyimide tubing.”
Method
Cited by
Wireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
Self-citationSubbaroyan, J., Martin, D. C., & Kipke, D. R. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/4/006 · Cited by 368
“Work is underway to modify chronic neural implants as closed loop devices by adding chemical sensing and drug delivering capabilities to them [8–10].”
BackgroundMicroelectrodes, Microelectronics, and Implantable Neural Microsystems
Wise, K. D., Sodagar, A. M., Yao, Y., Gulari, M. N., Perlin, G. E., & Najafi, K. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.922564 · Cited by 335
Self-citationSilicon microsystems for neuroscience and neural prostheses
Wise, K. D. (2005) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2005.1511497 · Cited by 194
Self-citationMetz, S., Bertsch, A., Bertrand, D., & Renaud, P. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2003.11.021 · Cited by 167
Metadata
- Authors
- Papageorgiou, D., Bledsoe, S. C., Gulari, M., Hetke, J. F., Anderson, D. J., & Wise, K. D.
- Venue
- Technical Digest. MEMS 2001. 14th IEEE International Conference on Micro Electro Mechanical Systems (Cat. No.01CH37090)
- Publisher
- IEEE
- Published
- 2002-11-13
- Pages
- 212-215
- OpenAlex
- W2147238837
- Cited by
- 33
- References
- 3
- FWCI
- 14.90
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A shuttered probe with in-line flowmeters for chronic in-vivo drug delivery. https://app.cochat.ai/papers/10.1109/memsys.2001.906516
- The paper
- Papageorgiou, D., Bledsoe, S. C., Gulari, M., Hetke, J. F., Anderson, D. J., & Wise, K. D. (2002). A shuttered probe with in-line flowmeters for chronic in-vivo drug delivery. Technical Digest. MEMS 2001. 14th IEEE International Conference on Micro Electro Mechanical Systems (Cat. No.01CH37090). https://doi.org/10.1109/memsys.2001.906516
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.