Modular Power Electronic Transformers: Modular Multilevel Converter Versus Cascaded H-Bridge Solutions
Open accessThe DOI matches its Crossref record; 54 of the 55 references it cites were found in a registry or an index.
Abstract
This article analyzes two modular power converter concepts, cascaded H-bridges (CHB) and modular multilevel converter (MMC) topologies, with special attention to the latter design. Both concepts have some characteristics in common and can provide the required functionalities for power electronic transformers (PETs). This analysis will cover aspects like the number of required cells, characteristics of the power devices, functionalities, and potential uses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multilevel inverters: a survey of topologies, controls, and applications
Rodriguez, J., Lai, J.-S., & Peng, F. Z. (2002) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2002.801052 · Cited by 6,715 · cited 2×
“14 IEEE IndustrIal ElEctronIcs magazInE ■ december 2016 and HVdc port currents as well as the current of the cell capacitor voltages vcell [26], [27], [35]–[41].”
BackgroundRecent Advances and Industrial Applications of Multilevel Converters
Kouro, S., Malinowski, M., Gopakumar, K., Pou, J., Franquelo, L. G., Wu, B., Rodriguez, J., Pérez, M. A., & Leon, J. I. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2049719 · Cited by 3,872 · cited 1×
“The cells’ capacitors are maintained at a constant target voltage (average) by the control in this case [17], [18].”
BackgroundAn innovative modular multilevel converter topology suitable for a wide power range
Lesnicar, A., & Marquardt, R. (2004) · 2003 IEEE Bologna Power Tech Conference Proceedings, · doi:10.1109/ptc.2003.1304403 · Cited by 2,908 · cited 3×
“Modulation of the commanded cell voltages must be combined with a sorting algorithm to avoid imbalances among the capacitor voltages [23], [24], [34].”
BackgroundA Survey on Cascaded Multilevel Inverters
Malinowski, M., Gopakumar, K., Rodriguez, J., & Pérez, M. A. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2030767 · Cited by 2,322 · cited 2×
“Commutation requirements for type 1 devices in CHB and MMC cells are low due to their multilevel nature [18], [41].”
BackgroundOperation, Control, and Applications of the Modular Multilevel Converter: A Review
Debnath, S., Qin, J., Bahrani, B., Saeedifard, M., & Barbosa, P. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2309937 · Cited by 2,210 · cited 1×
“The MMC can be seen as an evolution of the CHB to provide a dc port [20], [23]–[25].”
BackgroundHigh‐Power Converters and ac Drives
Wu, B. (2006) · Wiley eBooks · doi:10.1002/0471773719 · Cited by 1,640
High‐Power Converters and AC Drives
Wu, B., & Narimani, M. (2017) · doi:10.1002/9781119156079 · Cited by 1,571
Control and Experiment of Pulsewidth-Modulated Modular Multilevel Converters
Hagiwara, M., & Akagi, H. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2014236 · Cited by 1,565 · cited 4×
“It is seen from Figure 4, (7), and (8) that both arm (and, therefore, cell) voltages and currents include dc and ac components [26], [27]:”
BackgroundInfluentialDynamic Performance of a Modular Multilevel Back-to-Back HVDC System
Saeedifard, M., & Iravani, R. (2010) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2050787 · Cited by 1,188 · cited 3×
“Modulation of the commanded cell voltages must be combined with a sorting algorithm to avoid imbalances among the capacitor voltages [23], [24], [34].”
BackgroundClassification, Terminology, and Application of the Modular Multilevel Cascade Converter (MMCC)
Akagi, H. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2143431 · Cited by 1,172
(2018) · Elsevier eBooks · doi:10.1016/c2016-0-00847-1 · Cited by 940
On dynamics and voltage control of the Modular Multilevel Converter
Antonopoulos, A., Ängquist, L., & Nee, H. (2009) · European Conference on Power Electronics and Applications · Cited by 831
A New AC/AC Multilevel Converter Family
Glinka, M., & Marquardt, R. (2005) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2005.843973 · Cited by 772 · cited 1×
“The MMC can be seen as an evolution of the CHB to provide a dc port [20], [23]–[25].”
BackgroundVoltage and Power Balance Control for a Cascaded H-Bridge Converter-Based Solid-State Transformer
Zhao, T., Wang, G., Bhattacharya, S., & Huang, A. Q. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2216549 · Cited by 642
A new modular voltage source inverter topology
Marquardt, R. (2003) · Medical Entomology and Zoology · Cited by 503
Power Electronic Traction Transformer—Medium Voltage Prototype
Zhao, C., Dujic, D., Mester, A., Steinke, J. K., Weiss, M., Lewdeni-Schmid, S., Chaudhuri, T., & Stefanutti, P. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2278960 · Cited by 478 · cited 1×
“Traction and subsea systems are also examples of space-critical applications in which the improved performance and power density of PETs compared to LFTs can be determinant [6], [7].”
BackgroundAnalysis and Control of Modular Multilevel Converters With Integrated Battery Energy Storage
Vasiladiotis, M., & Rufer, A. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2303297 · Cited by 402 · cited 7×
“Two uses of the MMC-based implementation are 1) integration of DER and/or energy storage at the cell level and 2) its use in vessels.”
BackgroundInfluentialHagiwara, M., Maeda, R., & Akagi, H. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2089065 · Cited by 392
Rodriguez, A., Vazquez, A., Lamar, D. G., Hernando, M. M., & Sebastian, J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2309853 · Cited by 352 · cited 1×
“Values that are too low imply nonzero voltage switching under low loads, whereas values that are too large can limit the maximum power [44].”
BackgroundA power electronic-based distribution transformer
Ronan, E. R., Sudhoff, S. D., Glover, S. F., & Galloway, D. L. (2002) · IEEE Transactions on Power Delivery · doi:10.1109/61.997934 · Cited by 313
Son, G. T., Lee, H.-J., Nam, T. S., Chung, Y.-H., Lee, U.-H., Baek, S.-T., Hur, K., & Park, J.-W. (2012) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2012.2190530 · Cited by 290
Ilves, K., Antonopoulos, A., Norrga, S., & Nee, H.-P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2185832 · Cited by 286 · cited 1×
“In the limit, a switching frequency as low as the fundamental frequency can be achieved using staircase modulation, provided that the number of levels is large enough [42], [43].”
BackgroundTopology comparison for Solid State Transformer implementation
Falcones, S., Mao, X., & Ayyanar, R. (2010) · IEEE PES General Meeting · doi:10.1109/pes.2010.5590086 · Cited by 283 · cited 1×
“While PET designs using one, two, or three stages have been proposed [5], [8], a fully modular three-stage approach [Figure 1(a)] appears to be the most popular choice [2], [9]–[11].”
MethodA Power Electronic-Based Distribution Transformer
Ronan, E. R., Sudhoff, S. D., Glover, S. F., & Galloway, D. L. (2002) · IEEE Power Engineering Review · doi:10.1109/mper.2002.4312081 · Cited by 264 · cited 2×
“december 2016 ■ IEEE IndustrIal ElEctronIcs magazInE 7 overload protection; and low efficiency when operated with low load levels or no load [1].”
BackgroundMedium frequency topology in railway applications
Steiner, M., & Reinold, H. (2007) · 2007 European Conference on Power Electronics and Applications · doi:10.1109/epe.2007.4417570 · Cited by 249 · cited 1×
“Traction and subsea systems are also examples of space-critical applications in which the improved performance and power density of PETs compared to LFTs can be determinant [6], [7].”
BackgroundSolid-State-Transformers: Key Components of Future Traction and Smart Grid Systems
Kolar, J. W., & Ortiz, G. (2014) · The International Power Electronics Conference - ECCE ASIA · Cited by 188
Multilevel intelligent universal transformer for medium voltage applications
Lai, J.-S., Maitra, A., Mansoor, A., & Goodman, F. (2005) · Fourtieth IAS Annual Meeting. Conference Record of the 2005 Industry Applications Conference, 2005. · doi:10.1109/ias.2005.1518705 · Cited by 185
Jung, J.-J., Lee, H.-J., & Sul, S.-K. (2015) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2014.2323955 · Cited by 160
Comparison of Cascaded H-Bridge and Modular Multilevel Converters for BESS application
Baruschka, L., & Mertens, A. (2011) · 2011 IEEE Energy Conversion Congress and Exposition · doi:10.1109/ecce.2011.6063868 · Cited by 139 · cited 1×
“, can be found in [37]–[38].”
Circulating current suppressing controller in modular multilevel converter
Tu, Q., Xu, Z., & Zhang, J. (2010) · IECON 2010 - 36th Annual Conference on IEEE Industrial Electronics Society · doi:10.1109/iecon.2010.5675048 · Cited by 137 · cited 1×
“Additional control targets can include minimization of the switching losses, minimization of the cell capacitor voltage ripple or minimization of the harmonic content of the circulating current [33], [46], [47].”
BackgroundPicas, R., Pou, J., Ceballos, S., Agelidis, V. G., & Saeedifard, M. (2012) · IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society · doi:10.1109/iecon.2012.6388984 · Cited by 127 · cited 1×
“Additional control targets can include minimization of the switching losses, minimization of the cell capacitor voltage ripple or minimization of the harmonic content of the circulating current [33], [46], [47].”
BackgroundMilestones in Matrix Converter Research
Friedli, T., & Kolar, J. W. (2012) · IEEJ Journal of Industry Applications · doi:10.1541/ieejjia.1.2 · Cited by 125 · cited 1×
“8 IEEE IndustrIal ElEctronIcs magazInE ■ december 2016 has prevented widespread industrial application [12].”
BackgroundAnalysis and Simulation of a 6 kV, 6 MVA Modular Multilevel Converter
Rohner, S., Bernet, S., Hiller, M., & Sommer, R. (2009) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2009.5414775 · Cited by 90
Performance evaluation of solid state transformer based microgrid in FREEDM systems
She, X., Lukic, S., Huang, A. Q., Bhattacharya, S., & Baran, M. (2011) · 2011 Twenty-Sixth Annual IEEE Applied Power Electronics Conference and Exposition (APEC) · doi:10.1109/apec.2011.5744594 · Cited by 84 · cited 3×
“While PET designs using one, two, or three stages have been proposed [5], [8], a fully modular three-stage approach [Figure 1(a)] appears to be the most popular choice [2], [9]–[11].”
BackgroundMethodSolid state transformer in the future smart electrical system
She, X., & Huang, A. (2013) · 2013 IEEE Power & Energy Society General Meeting · doi:10.1109/pesmg.2013.6672768 · Cited by 81 · cited 1×
“High switching frequencies of the semiconductors also enable a significant reduction of the volume and weight of the core material [1]–[4].”
BackgroundOnboard DC grid employing smart grid technology: challenges, state of the art and future prospects
Kanellos, F. D., Tsekouras, G. J., & Prousalidis, J. (2015) · IET Electrical Systems in Transportation · doi:10.1049/iet-est.2013.0056 · Cited by 79 · cited 6×
“The IEEE Standard 1709 establishes 6, 12, 18, 24, and 30 kV as the preferred MVdc levels for future vessel designs [54].”
BackgroundInfluentialThe solid-state transformer concept: A new era in power distribution
van der Merwe, J. W., & du T. Mouton, H. (2009) · AFRICON 2009 · doi:10.1109/afrcon.2009.5308264 · Cited by 72 · cited 1×
“While PET designs using one, two, or three stages have been proposed [5], [8], a fully modular three-stage approach [Figure 1(a)] appears to be the most popular choice [2], [9]–[11].”
MethodOptimum number of cascaded cells for high-power medium-voltage multilevel converters
Huber, J. E., & Kolar, J. W. (2013) · 2013 IEEE Energy Conversion Congress and Exposition · doi:10.1109/ecce.2013.6646723 · Cited by 55 · cited 1×
“This also provides the opportunity to implement redundancy-based fault-tolerant designs [35], [36].”
BackgroundAdvanced power converters for universal and flexible power management in future electricity networks
Clare, J. (2009) · European Conference on Power Electronics and Applications · Cited by 55
Marzoughi, A., Burgos, R. P., Boroyevich, D., & Xue, Y. S. (2014) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2014.7048710 · Cited by 52 · cited 1×
“, can be found in [37]–[38].”
Briz, F., López, M., Rodríguez, A., Zapico, A., Arias, M., & Reigosa, D. (2015) · IEEE International Conference on Industrial Informatics (INDIN) · doi:10.1109/indin.2015.7281971 · Cited by 51 · cited 2×
“It is possible to extend the concept used in Figure 6 to the case of the MMC, with the resulting structure shown in Figure 8, [15], and [16].”
MethodSelf-citationEnhanced Flat-Topped Modulation for MMC Control in HVDC Transmission Systems
Li, R., Fletcher, J., Xu, L., & Williams, B. W. (2016) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2016.2561929 · Cited by 49 · cited 1×
“A discussion of the effects of triplen harmonic injection in the ac voltages of the MMC is found in [40]:”
BackgroundPower electronics for all-electric ships with MVDC power distribution system: An overview
Castellan, S., Menis, R., Tessarolo, A., & Sulligoi, G. (2014) · International Conference on Ecological Vehicles and Renewable Energies (EVER) · doi:10.1109/ever.2014.6844068 · Cited by 47 · cited 1×
“MVdc is considered a promising technology to improve power system performance [52], [53].”
BackgroundA topology for three-stage Solid State Transformer
Shojaei, A., & Joós, G. (2013) · IEEE Power Engineering Society General Meeting · doi:10.1109/pesmg.2013.6672781 · Cited by 44
Decoupled current control of modular multilevel converter for HVDC applications
Perez, M. A., Lizana F., R., & Rodriguez, J. (2012) · 2012 IEEE International Symposium on Industrial Electronics · doi:10.1109/isie.2012.6237396 · Cited by 44
Modular multilevel converter with integrated storage for solar photovoltaic applications
Perez, M. A., Arancibia, D., Kouro, S., & Rodriguez, J. (2013) · IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society · doi:10.1109/iecon.2013.6700292 · Cited by 40 · cited 7×
“Two uses of the MMC-based implementation are 1) integration of DER and/or energy storage at the cell level and 2) its use in vessels.”
BackgroundInfluentialOperation and control of MMCs using cells with power transfer capability
Briz, F., López, M., Zapico, A., Rodríguez, A., & Reigosa, D. (2015) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2015.7104468 · Cited by 35 · cited 1×
“, asymmetric among phases, arms, or cells), different types of imbalances can occur in the cell voltages and in the HVac port voltage [50], [51].”
BackgroundSelf-citationJung, J.-J., Lee, H.-J., & Sul, S. (2013) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2013.6646880 · Cited by 30
Design of Power Electronic Transformer Based on Modular Multilevel Converter
Zhu, H., Li, Y., Wang, P., Li, Z., & Chu, Z. (2012) · Asia-Pacific Power and Energy Engineering Conference (APPEEC) · doi:10.1109/appeec.2012.6307252 · Cited by 29
Liu, Y., Mejía, A. E., Farnell, C., Zhang, Y., Balda, J. C., & Mantooth, H. A. (2014) · IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG) · doi:10.1109/pedg.2014.6878625 · Cited by 26 · cited 1×
“Other MMC-based configurations can be found in [21] and [22].”
BackgroundDesign and implementation of the control of an MMC-based solid state transformer
Lopez, M., Rodriguez, A., Blanco, E., Saeed, M., Martinez, A., & Briz, F. (2015) · 2015 IEEE 13th International Conference on Industrial Informatics (INDIN) · doi:10.1109/indin.2015.7281970 · Cited by 24 · cited 2×
“■ ■ It is advantageous to distribute the DAB control in each cell, as the DABs operate independently (even if they all receive the same power command) and at much higher switching rates than the MMC cells [48].”
BackgroundSelf-citationComparative analysis of modular multiport power electronic transformer topologies
López, M., Briz, F., Saeed, M., Arias, M., & Rodríguez, A. (2016) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2016.7854932 · Cited by 24 · cited 1×
“The main parameters of the HF transformer are given in Table 2, its design and construction being a challenging task [45].”
BackgroundSelf-citationControl strategies for MMC using cells with power transfer capability
López, M., Briz, F., Zapico, A., Rodríguez, A., & Reigosa, D. (2015) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2015.7310165 · Cited by 13 · cited 2×
“, asymmetric among phases, arms, or cells), different types of imbalances can occur in the cell voltages and in the HVac port voltage [50], [51].”
BackgroundSelf-citationA stochastic optimal approach for fundamental frequency modulated modular multilevel converter
Shen, K., Liu, C., Wang, J., Cai, X., & Ji, Y. (2012) · IEEE Power Engineering Society General Meeting · doi:10.1109/pesgm.2012.6345245 · Cited by 2 · cited 1×
“In the limit, a switching frequency as low as the fundamental frequency can be achieved using staircase modulation, provided that the number of levels is large enough [42], [43].”
Background
Research works printed but not linked: 4
- 2013, Silicon carbide power technology for energy-efficient devices (SPEED)
- marzoughi, 0, Investigation and comparison of cascadedH-bridge and modular multilevel convertertopologies for medium-voltoge drive application, Proc IEEE Annu Conf Industrial Electronics Soc, 1562
- li, 0, Control and performance of a modular multilevel converter system, Proc Conf Power Systems (CIGRE), 1
- 2010, IEEE Recommended Practice for 1 KV to 35 KV Medium-Voltage DC Power Systems on Ships
Cited by
Hannan, M. A., Ker, P. J., Lipu, M. S. H., Choi, Z. H., Rahman, M. S. A., Muttaqi, K. M., & Blaabjerg, F. (2020) · IEEE Access · doi:10.1109/access.2020.2967345 · Cited by 339
“[25] concentrated on two modular power converter design concepts; one is the cascaded-H bridge (CHB) and the other is modular multilevel converter (MMC) topologies.”
BackgroundModular Multilevel Converters: Recent Achievements and Challenges
Perez, M. A., Ceballos, S., Konstantinou, G., Pou, J., & Aguilera, R. P. (2021) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2021.3060791 · Cited by 327
“connected in series providing high voltage rating, and the secondary stages in parallel providing high current rating [168], mimicking the feature of a distribution transformer.”
BackgroundGrid-Connected Energy Storage Systems: State-of-the-Art and Emerging Technologies
Farivar, G. G., Manalastas, W., Tafti, H. D., Ceballos, S., Sanchez-Ruiz, A., Lovell, E. C., Konstantinou, G., Townsend, C. D., Srinivasan, M., & Pou, J. (2023) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3183289 · Cited by 203
Ahmad, A., Qin, Z., Wijekoon, T., & Bauer, P. (2022) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2022.3179743 · Cited by 160
“SiC and GaN switches, on the other hand, overcame these difficulties and enabled MV applications without cascading identical SMs. Numerous MV applications of NPC converters are available in the literature [144]–[146].”
BackgroundElsanabary, A., Konstantinou, G. S., Mekhilef, S., Townsend, C. D., Seyedmahmoudian, M., & Stojcevski, A. (2020) · IEEE Access · doi:10.1109/access.2020.3044882 · Cited by 157
“This inevitable evolution will lead the transition from ‘‘grid-following’’ inverters, which are currently used in the grid, to ‘‘gridforming’’ inverters, which have the ability to stabilize the grid voltage and regulate the frequency [10].”
Background
Metadata
- Authors
- Briz, F., Lopez, M., Rodriguez, A., & Arias, M.
- Affiliations
- Universidad de Oviedo (ES)
- Venue
- IEEE Industrial Electronics Magazine
- Published
- 2016
- Volume
- 10
- Issue
- 4
- Pages
- 6-19
- ISSN
- 1932-4529 (ISSN-L)
- OpenAlex
- W2562166267
- Cited by
- 171
- References
- 55
- Citations by year
- 2026: 11 · 2025: 14 · 2024: 12 · 2023: 18 · 2022: 16 · 2021: 30 · 2020: 30 · 2019: 16 · 2018: 19 · 2017: 5
- FWCI
- 6.15
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Locations
- IEEE Industrial Electronics Magazine (publishedVersion)
- Consultation of the Doctoral Thesis Database (TESEO) (Ministerio de Educación, Cultura y Deporte) (submittedVersion, cc-by-nc-nd)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Keywords
- solid-state transformer, modular multilevel converter, cascaded H-bridge inverter
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.