The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Radar remote monitoring of vital signs
Abstract
Medical technology has improved remarkably over the past few generations, becoming more sophisticated and less invasive as the years progress. Now, with microwave Doppler radar phase modulation, noncontact respiration and heartbeat monitoring offers an attractive alternative to commonly prescribed chest-strap monitors. Doppler radar uses double-sideband transmission for vital sign detection from four sides of a human body. An unmodulated radio-frequency signal is transmitted toward the human body, where it is phase-modulated by the periodic physiological movement and reflected back to the receiver. The radar receiver captures the reflected signal and demodulates it to extract the vital sign signal components.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Droitcour, A. D., Boric-Lubecke, O., Lubecke, V. M., Lin, J., & Kovacs, G. T. A. (2004) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2004.823552 · Cited by 662
Arctangent Demodulation With DC Offset Compensation in Quadrature Doppler Radar Receiver Systems
Park, B.-K., Boric-Lubecke, O., & Lubecke, V. M. (2007) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2007.895653 · Cited by 604
Efficient mixed-spectrum estimation with applications to target feature extraction
Li, J., & Stoica, P. (1996) · IEEE Transactions on Signal Processing · doi:10.1109/78.485924 · Cited by 546
Random Body Movement Cancellation in Doppler Radar Vital Sign Detection
Li, C., & Lin, J. (2008) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2008.2007139 · Cited by 448
Self-citationChen, K.-M., Huang, Y., Zhang, J., & Norman, A. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.817625 · Cited by 445
Noninvasive microwave measurement of respiration
Lin, J. C. (1975) · Proceedings of the IEEE · doi:10.1109/proc.1975.9992 · Cited by 429
Microwave sensing of physiological movement and volume change: A review
Lin, J. C. (1992) · Bioelectromagnetics · doi:10.1002/bem.2250130610 · Cited by 299
An X-Band Microwave Life-Detection System
Chen, K., Misra, D. K., Wang, H., Chuang, H.-R., & Postow, E. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325760 · Cited by 284
Xiao, Y., Lin, J., Boric-Lubecke, O., & Lubecke, M. (2006) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2006.873625 · Cited by 259
A microwave radio for Doppler radar sensing of vital signs
Droitcour, A., Lubecke, V., Lin, J., & Boric-Lubecke, O. (2002) · 2001 IEEE MTT-S International Microwave Sympsoium Digest (Cat. No.01CH37157) · doi:10.1109/mwsym.2001.966866 · Cited by 252
Li, C., Xiao, Y., & Lin, J. (2006) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2006.884652 · Cited by 245
Self-citationLi, C., & Lin, J. (2008) · 2008 IEEE MTT-S International Microwave Symposium Digest · doi:10.1109/mwsym.2008.4633229 · Cited by 192
Self-citationDroitcour, A. D., Borić-Lubecke, O., Lubecke, V. M., & Lin, J. (2003) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2002.993075 · Cited by 105
Range correlation effects on phase and amplitude noise
Budge, M. C., & Burt, M. P. (2002) · IEEE SoutheastCon · doi:10.1109/secon.1993.465731 · Cited by 79
A 5GHz Double-Sideband Radar Sensor Chip in 0.18$\mu$m CMOS for Non-Contact Vital Sign Detection
Li, C., Xiao, Y., & Lin, J. (2008) · IEEE Microwave and Wireless Components Letters · doi:10.1109/lmwc.2008.925112 · Cited by 54
Self-citationThe recording of heart vibrations: a problem of vibration measurement on soft tissue
Vermarien, H., & van Vollenhoven, E. (1984) · Medical & Biological Engineering & Computing · doi:10.1007/bf02446821 · Cited by 48
Design Guidelines for Radio Frequency Non-contact Vital Sign Detection
Li, C., Xiao, Y., & Lin, J. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4352624 · Cited by 24
Self-citation
Cited by
Vital-sign monitoring and spatial tracking of multiple people using a contactless radar-based sensor
Mercuri, M., Lorato, I. R., Liu, Y.-H., Wieringa, F., Hoof, C. V., & Torfs, T. (2019) · Nature Electronics · doi:10.1038/s41928-019-0258-6 · Cited by 354
Automated Detection of Engagement Using Video-Based Estimation of Facial Expressions and Heart Rate
Monkaresi, H., Bosch, N., Calvo, R. A., & D'Mello, S. K. (2017) · IEEE Transactions on Affective Computing · doi:10.1109/taffc.2016.2515084 · Cited by 329
DoppleSleep: a contactless unobtrusive sleep sensing system using short-range Doppler radar
Rahman, T., Adams, A. T., Ravichandran, R. V., Zhang, M., Patel, S. N., Kientz, J. A., & Choudhury, T. (2015) · Proceedings of the 2015 ACM International Joint Conference on Pervasive and Ubiquitous Computing · doi:10.1145/2750858.2804280 · Cited by 175
Estimation of Respiration Rate from Three-Dimensional Acceleration Data Based on Body Sensor Network
Liu, G.-Z., Guo, Y.-W., Zhu, Q.-S., Huang, B.-Y., & Wang, L. (2011) · Telemedicine and e-Health · doi:10.1089/tmj.2011.0022 · Cited by 107
Metadata
- Authors
- Li, C., Cummings, J., Lam, J., Graves, E., & Wu, W.
- Venue
- IEEE Microwave Magazine
- Published
- 2009-02
- Volume
- 10
- Issue
- 1
- Pages
- 47-56
- ISSN
- 1527-3342 (ISSN-L)
- OpenAlex
- W2158388235
- Cited by
- 255
- References
- 17
- FWCI
- 7.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.