Neural Interfaces for Upper-Limb Prosthesis Control: Opportunities to Improve Long-Term Reliability
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Building on a long history of innovation in neural-recording interfaces, the Defense Advanced Research Projects Agency (DARPA) has launched a program to address the key challenges related to transitioning advanced neuroprosthesis technology to clinical use for amputated service members. The goal of the Reliable Neural Technology (RE-NET) Program is to develop new technology to extract information from the nervous system at a scale and rate needed to reliably control modern robotic prostheses over the lifetime of the amputee. The RE-NET program currently encompasses three separate efforts: histology for interface stability over time (HIST), reliable peripheral interfaces (RPIs), and reliable central nervous system (CNS) interfaces (RCIs).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
Rousche, P. J., & Normann, R. A. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00031-4 · Cited by 646 · cited 1×
“Leading probe-array technologies [5]–[7] were advanced in the 2000s by commercialization efforts that are still ongoing.”
Simeral, J. D., Kim, S.-P., Black, M. J., Donoghue, J. P., & Hochberg, L. R. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025027 · Cited by 496
Cited by
A high-performance neural prosthesis enabled by control algorithm design
Gilja, V., Nuyujukian, P., Chestek, C. A., Cunningham, J. P., Yu, B. M., Fan, J. M., Churchland, M. M., Kaufman, M. T., Kao, J. C., Ryu, S. I., et al. (2012) · Nature Neuroscience · doi:10.1038/nn.3265 · Cited by 564
Restoring sensorimotor function through intracortical interfaces: progress and looming challenges
Bensmaia, S. J., & Miller, L. E. (2014) · Nature Reviews Neuroscience · doi:10.1038/nrn3724 · Cited by 368
Takmakov, P., Ruda, K., Scott Phillips, K., Isayeva, I. S., Krauthamer, V., & Welle, C. G. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/2/026003 · Cited by 178
Tissue-engineered peripheral nerve interfaces
Spearman, B. S., Desai, V. H., Mobini, S., McDermott, M. D., Graham, J. B., Otto, K. J., Judy, J. W., & Schmidt, C. E. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701713 · Cited by 96
Self-citationBiological and bionic hands: natural neural coding and artificial perception
Bensmaia, S. J. (2015) · Philosophical Transactions of the Royal Society B Biological Sciences · doi:10.1098/rstb.2014.0209 · Cited by 67
Metadata
- Authors
- Judy, J. W.
- Venue
- IEEE Pulse
- Published
- 2012-03
- Volume
- 3
- Issue
- 2
- Pages
- 57-60
- ISSN
- 2154-2287 (ISSN-L)
- OpenAlex
- W2081523561
- Cited by
- 29
- References
- 2
- FWCI
- 1.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Neural Interfaces for Upper-Limb Prosthesis Control: Opportunities to Improve Long-Term Reliability. https://app.cochat.ai/papers/10.1109/mpul.2011.2181026
- The paper
- Judy, J. W. (2012). Neural Interfaces for Upper-Limb Prosthesis Control: Opportunities to Improve Long-Term Reliability. IEEE Pulse. https://doi.org/10.1109/mpul.2011.2181026
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.