Toward Intuitive Prosthetic Control: Solving Common Issues Using Force Myography, Surface Electromyography, and Pattern Recognition in a Pilot Case Study
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
Despite the appearance of advanced multi-degrees of freedom (DoF) robotic hands during the past decade, prosthetic control lacks a powerful interface to facilitate all its functionalities in a manner that is acceptable for a majority of users. In this article, we explore the feasibility of using a sensing technique called force myography (FMG) as an alternative or synergist to the traditional surface electromyography (sEMG) technique as a human-machine interface (HMI) for the control of a multi-DoF prosthetic hand, bebionic 3 by Ottobock, Austin, Texas. In this article, we present a prosthetic prototype developed for the Cybathlon 2016, a championship for racing pilots with disabilities using assistive robotic devices. The design of the prototype is discussed and the effect of two factors on its control is analyzed. These factors are 1) the impact of a multisensory approach and 2) the placement of FMG sensor strips within the prosthetic inner socket. Analysis is performed by comparing resulting pattern recognition accuracies. Results show that the use of both sensing modalities (FMG and EMG) together produced the highest pattern recognition accuracy (81.1%) for ten classes of motion (four wrist movements and six grip patterns). We demonstrated that FMG has the potential to be an HMI for control of upper-limb-powered prostheses. FMG also illustrates the potential for intuitive control through the use of pattern recognition. A multisensory approach could assist in increasing ro…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“As the most common brain signal in clinical applications, EEG has been widely utilized in prosthetics and other HMI applications.[285,399]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [399]
Citations
Cites
Neural Networks and the Bias/Variance Dilemma
Geman, S., Bienenstock, E., & Doursat, R. (1992) · Neural Computation · doi:10.1162/neco.1992.4.1.1 · Cited by 3,578
Estimating the Prevalence of Limb Loss in the United States: 2005 to 2050
Ziegler-Graham, K., MacKenzie, E. J., Ephraim, P. L., Travison, T. G., & Brookmeyer, R. (2008) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2007.11.005 · Cited by 2,816 · cited 1×
“In 2005, 41,000 individuals in the United States were living with the debilitating loss of an upper limb [2].”
BackgroundUpper limb prosthesis use and abandonment: A survey of the last 25 years
Biddiss, E. A., & Chau, T. T. (2007) · Prosthetics & Orthotics International · doi:10.1080/03093640600994581 · Cited by 1,111 · cited 2×
“During the past decade, multiple sophisticated powered prosthetic hands have become available in the market, yet the rejection rate for electric upper-limb prostheses is roughly 30% [1] due to dissatisfaction about issues like cosmetics, comfort, function, ease of control, reliability, and cost [4].”
BackgroundUpper-Limb Prosthetics: Critical Factors in Device Abandonment
Biddiss, E., & Chau, T. (2007) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0b013e3181587f6c · Cited by 645 · cited 2×
“Conclusions and Future Work Among others, the ease of control and reliability are some of the reasons for the high rejection rate of powered prostheses [4].”
BackgroundControl of upper limb prostheses: terminology and proportional myoelectric control-a review
Fougner, A., Stavdahl, Ø., Kyberd, P. J., Losier, Y. G., & Parker, P. A. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2196711 · Cited by 495 · cited 1×
“In spite of the availability of multi-DoF upper-limb prostheses, the reliable and natural control of such robotic hands is still an issue [5].”
BackgroundMyoelectric forearm prostheses: State of the art from a user-centered perspective
Peerdeman, B., Boere, D., Witteveen, H., Huis in `tVeld, R., Hermens, H., Stramigioli, S., Rietman, H., Veltink, P., & Misra, S. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.08.0161 · Cited by 469 · cited 6×
“To simulate activities of daily living (ADL), we used a proven dynamic protocol as a reasonable simulation [11].”
BackgroundInfluentialCastellini, C., Artemiadis, P., Wininger, M., Ajoudani, A., Alimusaj, M., Bicchi, A., Caputo, B., Craelius, W., Dosen, S., Englehart, K., et al. (2014) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2014.00022 · Cited by 221 · cited 1×
“This unintuitive control has been one of the causes for prostheses abandonment [6].”
BackgroundForce Myography to Control Robotic Upper Extremity Prostheses: A Feasibility Study
Cho, E., Chen, R. J., Merhi, L.-K., Xiao, Z. G., Pousett, B. M., & Menon, C. (2016) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2016.00018 · Cited by 166 · cited 4×
“Much of the (limited) research using subjects with an amputation has employed static protocols [9], [13] that limit arm movement during experiments, which cannot ensure the system’s usability in the dynamic movements used in daily life [3].”
BackgroundMethodSelf-citationHigh-density force myography: A possible alternative for upper-limb prosthetic control
Radmand, A., Scheme, E., & Englehart, K. B. (2016) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2015.03.0041 · Cited by 164 · cited 7×
“Because this study’s objective was to investigate a practical system, all experimental data were recorded using the dynamic protocol [11] shown in Figure 4.”
BackgroundMethodResultInfluentialNaik, G. R., Al-Timemy, A. H., & Nguyen, H. T. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2478138 · Cited by 160 · cited 4×
“To compare our results with a study [11] focused on dynamic protocols, classes of motion, and HMI that are similar to the ones used in this study, the rest of the offline data analysis described in this article used the LDA classification algorithm.”
MethodInfluential
Cited by
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Wang, H., Ding, Q., Luo, Y., Wu, Z., Yu, J., Chen, H., Zhou, Y., Zhang, H., Tao, K., Chen, X., et al. (2024) · Advanced Materials · doi:10.1002/adma.202309868 · Cited by 290
A Review of Force Myography Research and Development
Xiao, Z. G., & Menon, C. (2019) · Sensors · doi:10.3390/s19204557 · Cited by 169
“Reference Title Publication Type Yungher et al., 2012 [34] Improving fine motor function after brain injury using gesturerecognition biofeedback Journal Castellini et al., 2012 [74] Intention Gathering from Muscle Residual Activity for the SeverelyDisabled Proceeding Dementyev et al., 2014 [30] WristFlex Proceeding Ra…”
BackgroundMethodResultInfluentialSelf-citationA novel, co-located EMG-FMG-sensing wearable armband for hand gesture recognition
Jiang, S., Gao, Q., Liu, H., & Shull, P. B. (2020) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2019.111738 · Cited by 169
Bao, T., Xie, S. Q., Yang, P., Zhou, P., & Zhang, Z. (2022) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2022.3159792 · Cited by 96
“Ahmadizadeh et al. [45] investigated the feasibility of FMG as a synergist to sEMG in commercial prosthetic hands.”
BackgroundZhou, H., & Alıcı, G. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3169492 · Cited by 101
Selection of Features and Classifiers for EMG-EEG-Based Upper Limb Assistive Devices—A Review
Khan, S. M., Khan, A. A., & Farooq, O. (2019) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2019.2950897 · Cited by 77
“[118] C.”
A Layered sEMG–FMG Hybrid Sensor for Hand Motion Recognition From Forearm Muscle Activities
Chen, P., Li, Z., Togo, S., Yokoi, H., & Jiang, Y. (2023) · IEEE Transactions on Human-Machine Systems · doi:10.1109/thms.2023.3287594 · Cited by 58
Ali, A., Khan, S. J., Azim, F., Shakeel, C. S., Hussain, A., & Niazi, I. K. (2022) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/09544119221074770 · Cited by 57
“Another study focused on the technique involving force-myography and emphasized solving surface electromyography and pattern recognition applications.(107) A new and non-invasive sensor was introduced that can be used as an alternative to EMG signal collection.”
BackgroundAhmadizadeh, C., Khoshnam, M., & Menon, C. (2021) · IEEE Signal Processing Magazine · doi:10.1109/msp.2021.3057042 · Cited by 48
Self-citationAn Ultra-Sensitive Modular Hybrid EMG–FMG Sensor with Floating Electrodes
Ke, A., Huang, J., Chen, L., Gao, Z., & He, J. (2020) · Sensors · doi:10.3390/s20174775 · Cited by 46
Classification of 41 Hand and Wrist Movements via Surface Electromyogram Using Deep Neural Network
Sri-iesaranusorn, P., Chaiyaroj, A., Buekban, C., Dumnin, S., Pongthornseri, R., Thanawattano, C., & Surangsrirat, D. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.548357 · Cited by 44
“Moreover, frequent misclassifications of intended actions could lead to frustration and prostheses abandonment (Biddiss and Chau, 2007; Ahmadizadeh et al., 2017).”
BackgroundZou, Y., Cheng, L., & Li, Z. (2022) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2022.3177486 · Cited by 32
Regressing grasping using force myography: an exploratory study
Chegani, R. S., & Menon, C. (2018) · BioMedical Engineering OnLine · doi:10.1186/s12938-018-0593-2 · Cited by 35
“[20] along with other works [21, 22], have showed FMG has the potential to yield promising result when used to control a prosthetic arm in transradial amputee.”
Self-citationA survey on the state of the art of force myography technique (FMG): analysis and assessment
Sherif, O., Bassuoni, M. M., & Mehrez, O. (2024) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-024-03019-w · Cited by 40
“Most common classification techniques used for FMG are linear discriminant analysis (LDA) [25, 48, 109, 110], support vector machine (SVM) [2, 23, 113] and artificial neural network (ANN) [77].”
MethodAhmadizadeh, C., Pousett, B. M., & Menon, C. (2019) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2019.00331 · Cited by 28
“Various classification methods have been assessed for FMG controlled prostheses, some of the commonly used ones of which are linear discriminant analysis (LDA), support vector machine (SVM), and k-nearest neighbors (KNN) (Naik et al., 2015; Ahmadizadeh et al., 2017).”
BackgroundMethodInfluentialSelf-citationHuman-machine shared control: New avenue to dexterous prosthetic hand manipulation
Yang, D., & Liu, H. (2020) · Science China Technological Sciences · doi:10.1007/s11431-020-1710-y · Cited by 25
An Investigation on the Sampling Frequency of the Upper-Limb Force Myographic Signals
Xiao, Z. G., & Menon, C. (2019) · Sensors · doi:10.3390/s19112432 · Cited by 24
“For example, FMG signals from near the wrist or around the proximal forearm have been used to detect the number of grasping actions during a pick-and-place exercise [3] and to control an external robotic device such as a hand prosthesis [4].”
MethodSelf-citationParaconsistent Random Forest: An Alternative Approach for Dealing With Uncertain Data
Favieiro, G. W., & Balbinot, A. (2019) · IEEE Access · doi:10.1109/access.2019.2946256 · Cited by 24
Nowak, M., Eiband, T., Ramírez, E. R., & Castellini, C. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab7b1e · Cited by 25
A Multipurpose Wearable Sensor-Based System for Weight Training
Balkhi, P., & Moallem, M. (2022) · Automation · doi:10.3390/automation3010007 · Cited by 23
“In [14], the authors introduced a new methodology using FSR sensors for controlling robotic prosthesis in practical settings such as Cybathlon competition.”
MethodA Multipurpose Human–Machine Interface via 3D-Printed Pressure-Based Force Myography
Zhou, H., Tawk, C., & Alıcı, G. (2024) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2024.3375376 · Cited by 21
“In addition, having a hybrid solution by combining FSR sensors and sEMG electrodes resulted in accuracies of 81.1% when six or more gestures are classified which is considered low compared to other existing solutions [19].”
BackgroundMethodInfluentialA patterned mechanical–electrical coupled sensing patch for multimodal muscle function evaluation
Xue, J., Zou, Y., Wan, Z., Liu, M., Wang, Y., Chu, H., Tan, P., Wu, L., Wang, E., Ouyang, H., et al. (2024) · InfoMat · doi:10.1002/inf2.12631 · Cited by 22
Ovadia, D., Segal, A., & Rabin, N. (2024) · Scientific Reports · doi:10.1038/s41598-024-54677-7 · Cited by 22
Asfour, M., Menon, C., & Jiang, X. (2021) · Sensors · doi:10.3390/s21041504 · Cited by 19
Self-citationA Novel Motion Recognition Method Based on Force Myography of Dynamic Muscle Contractions
Li, X., Zheng, Y., Liu, Y., Tian, L., Fang, P., Cao, J., & Li, G. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.783539 · Cited by 20
Lei, G., Zhang, S., Fang, Y., Wang, Y., & Zhang, X. (2021) · Sensors · doi:10.3390/s21113872 · Cited by 17
“As summarized in Table 1, RMS is one of the most commonly used FMG feature [11,13,16], and SVM [9,10,13,16,17,21] and LDA [13–20,22] are the most commonly used classifiers for FMG based hand gesture classification.”
MethodDesign of Tendon-Actuated Robotic Glove Integrated with Optical Fiber Force Myography Sensor
Neto, A. R., Fajardo, J. V., Silva, W. H. A., Gomes, M. K., Castro, M. C. F., Fujiwara, E., & Rohmer, E. (2021) · Automation · doi:10.3390/automation2030012 · Cited by 20
“A pilot study of a wrist orthosis controlled by FMG is shown in [14], whereas another study [15] integrates FMG and sEMG to operate a multi-grasp bionic prosthesis.”
MethodGantenbein, J., Ahmadizadeh, C., Heeb, O., Lambercy, O., & Menon, C. (2023) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-023-01222-8 · Cited by 14
“Primarily, FMG has been used in gesture classification for prosthetics [7, 8, 13, 14].”
BackgroundMethodSelf-citationAhmadizadeh, C., & Menon, C. (2019) · Sensors · doi:10.3390/s19245519 · Cited by 13
Self-citationA Wearable Force Myography-Based Armband for Recognition of Upper Limb Gestures
Rehman, M. U., Shah, K., Haq, I. U., Iqbal, S., & Ismail, M. A. (2023) · Sensors · doi:10.3390/s23239357 · Cited by 12
“The effect of elbow and shoulder movements needs to be considered.”
BackgroundMethodCan Prosthetic Hands Mimic a Healthy Human Hand?
Ng, K. H., Nazari, V., & Alam, M. (2021) · Prosthesis · doi:10.3390/prosthesis3010003 · Cited by 11
“With 14 different grip styles and hand configurations, this robot helps patients perform activities of daily living (ADL), such as fixing shoelaces, holding luggage, opening doors, eating, flipping on lights, texting and more [16].”
Li, J., Zhu, Z., Boyd, W. J., Martinez-Luna, C., Dai, C., Wang, H., Wang, H., Huang, X., Farrell, T. R., & Clancy, E. A. (2022) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2023.104602 · Cited by 12
Assessment of Low-Density Force Myography Armband for Classification of Upper Limb Gestures
Rehman, M. U., Shah, K., Haq, I. U., Iqbal, S., Ismail, M. A., & Selımefendıgıl, F. (2023) · Sensors · doi:10.3390/s23052716 · Cited by 15
“Static Limb Position Protocol During static limb position, the elbow and shoulder positions were fixed, and data for the hand, wrist, and forearm gestures, as mentioned earlier, were recorded.”
BackgroundMethodResultInfluentialDeep Learning Technique in Recognizing Hand Grasps using FMG signals
Zakia, U., Jiang, X., & Menon, C. (2020) · IEEE Annual Information Technology, Electronics and Mobile Communication Conference (IEMCON) · doi:10.1109/iemcon51383.2020.9284893 · Cited by 11
Self-citationFujiwara, E., Rodrigues, M. D. S., Gomes, M. K., Wu, Y. T., & Suzuki, C. K. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3071669 · Cited by 12
“Typical systems use arrays of force-sensing resistors (FSR) attached to the forearm with an orthosis or straps for detecting the muscular activity [9]; combining FMG with sEMG electrodes may enhance the classifier performance [11].”
BackgroundMethodInfluentialMyoelectric Pattern Recognition Performance Enhancement Using Nonlinear Features
Islam, M. J., Ahmad, S., Haque, F., Reaz, M. B. I., Bhuiyan, M. A. S., Minhad, K. N., & Islam, M. R. (2022) · Computational Intelligence and Neuroscience · doi:10.1155/2022/6414664 · Cited by 11
“In addition to EMG signal, force myography (FMG), a non-invasive technique for measuring the pressure patterns between the underlying muscle and the pressure sensor during muscle contraction, is also used for upper limb prosthetic control [14-17].”
MethodYoung, P. R., Hong, K.-S., Winslow, E. J., Sagastume, G. K., Battraw, M. A., Whittle, R. S., & Schofield, J. S. (2025) · PLoS ONE · doi:10.1371/journal.pone.0321319 · Cited by 13
“The effects of limb position and grasped load on hand gesture classification the combination of the 2 sensing modalities in gesture classification, as some articles describe no statistical differences [34,37] while others find an improved accuracy with the combination [33,35,36].”
Sun, J., Chen, Y., Du, X., Yu, R., Zhou, T., Yang, Z., Qiu, J., Zhang, Z., Zhu, M., & Pan, S. (2025) · Science China Materials · doi:10.1007/s40843-025-3426-8 · Cited by 10
“Currently, researchers have combined rigid commercial FMG and EMG sensors to achieve multi-signal acquisition of human arm muscle movements [23,24].”
sEMG-Based Hand Posture Recognition and Visual Feedback Training for the Forearm Amputee
Kim, J., Yang, S., Koo, B., Lee, S., Park, S.-H., Kim, S., Cho, K. H., & Kim, Y. (2022) · Sensors · doi:10.3390/s22207984 · Cited by 11
Mechatronic Design and Control of a 3D Printed Low Cost Robotic Upper Limb
Carter-Davies, D., Chen, J., Chen, F., Li, M., & Yang, C. (2018) · doi:10.1109/hfr.2018.8633519 · Cited by 7
“In terms o f commercial options, the Bebionic3 hand by Bebionic has individually actuated fingers, with 14 preprogramed grip patterns and poses [9].”
BackgroundA Hybrid sEMG-FMG Sensor Fusion Approach Under Muscle Fatigue Using Cascade Fuzzy Forest
Fang, Y., Wu, L., Yu, X., Peng, Y. K., Wang, Y., & Ju, Z. (2024) · IEEE Transactions on Fuzzy Systems · doi:10.1109/tfuzz.2024.3505260 · Cited by 5
“Previous studies have typically recorded sEMG and FMG signals separately at different locations [42], [43], [44].”
Qadir, M. U., Haq, I. U., Khan, M. A., Ahmad, M. N., Shah, K., & Akhtar, N. (2021) · IEEE Access · doi:10.1109/access.2021.3113029 · Cited by 5
“Other studies [39]–[42] also explored the”
Gomes, M. K., da Silva, W. H. A., Neto, A. R., Fajardo, J. V., Rohmer, E., & Fujiwara, E. (2022) · Automation · doi:10.3390/automation3040031 · Cited by 4
Li, H., Guo, S., He, R., Wang, B., & Ding, M. (2026) · Measurement · doi:10.1016/j.measurement.2026.121320 · Cited by 3
Baklouti, S., Rezgui, T., Chaker, A., Mefteh, S., Mansour, K. B., Sahbani, A., & Bennour, S. (2024) · Arabian Journal for Science and Engineering · doi:10.1007/s13369-024-09138-8 · Cited by 3
“Using FMG for several applications, such as motion recognition [30], hand gesture classification [52], and estimating isometric torque generated by the wrist and forearm [53].”
Andreas, D., Hou, Z., Tabak, M. O., Dwivedi, A., & Beckerle, P. (2024) · Sensors · doi:10.3390/s24196214 · Cited by 4
k-Tournament Grasshopper Extreme Learner for FMG-Based Gesture Recognition
Barioul, R., & Kanoun, O. (2023) · Sensors · doi:10.3390/s23031096 · Cited by 3
“Many studies have shown the advantages of FMG over EMG signals [19,27].”
BackgroundChen, Z., Hu, Y., Huang, P., Huang, J., Wang, H., & Li, G. (2018) · International Conference on Computer Science and Application Engineering (CSAE) · doi:10.1145/3207677.3278093 · Cited by 3
“In order to overcome the limitation of EMG signals, it is often combined with other signals such as force myography (FMG) especially for upper limb movement intent prediction [5].”
BackgroundForce Myography across Socket Material
Curcio, B. C., Cirillo, N. V., & Wininger, M. (2019) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/jpo.0000000000000295 · Cited by 2
Zhuang, M., Li, G., & Ding, K. (2022) · Mobile Information Systems · doi:10.1155/2022/8715036 · Cited by 2
“Kinematics analysis [19] (Kinematic Analysis) includes forward kinematics analysis (Forward Kinematic Analysis) and inverse kinematics analysis [20] (Inverse Kinematic Analysis).”
MethodData and Sensor Fusion Using FMG, sEMG and IMU Sensors for Upper Limb Prosthesis Control
Gharibo, J. S. (2021) · Scholarship@Western (Western University) · Cited by 5
Towards a modular and dexterous transhumeral prosthesis based on bio-signals and active vision
Phương, N. D., & Pham, C. T. (2019) · International Symposium on Measurement and Control in Robotics (ISMCR) · doi:10.1109/ismcr47492.2019.8955664 · Cited by 1
“Subsequently, there have been various researches discussing hybrid designs that tackle multiple constraints of available solutions [5-7].”
BackgroundDesign of interactive neural input device for arm prosthesis
Ozsahin, D. U., Duwa, B. B., Idoko, J. B., Tirah, G., Alchoib, A., Abuedia, A. M. Y., Alshobaki, M., Ishimwe, D., & Özşahin, İ. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-14133-1.00006-9
朱, 蓉. (2024) · Traditional Chinese Medicine · doi:10.12677/tcm.2024.131036
Wang, H., Zhou, Y., Luo, Y., Shi, W., Li, J., Xiao, M., Xie, R., Zou, B., Chen, H., Wang, Y., et al. (2025) · Research Square · doi:10.21203/rs.3.rs-7611464/v1
Yao, X., Yang, D., Zhang, M., She, Y., & Tian, Y. (2026) · Chemical Engineering Journal · doi:10.1016/j.cej.2026.182471
Metadata
- Authors
- Ahmadizadeh, C., Merhi, L.-K., Pousett, B., Sangha, S., & Menon, C.
- Affiliations
- Simon Fraser University (CA)
- Barber Prosthetic Clinic, Vancouver, British Columbia, Canada
- Venue
- IEEE Robotics & Automation Magazine
- Published
- 2017-12
- Volume
- 24
- Issue
- 4
- Pages
- 102-111
- ISSN
- 1070-9932 (ISSN-L)
- 1558-223X
- OpenAlex
- W2767382018
- Cited by
- 57
- References
- 18
- Citations by year
- 2026: 2 · 2025: 3 · 2024: 9 · 2023: 6 · 2022: 11 · 2021: 10 · 2020: 4 · 2019: 9 · 2018: 3
- FWCI
- 1.97
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Robotics & Automation Magazine (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Keywords
- force myography, surface electromyography, prosthetic hand control, human-machine interaction, pattern recognition, sensor placement, grip patterns, wrist kinematics, upper limb prosthesis, intuitive control
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.