CoChat

Toward Intuitive Prosthetic Control: Solving Common Issues Using Force Myography, Surface Electromyography, and Pattern Recognition in a Pilot Case Study

Ahmadizadeh, Chakaveh, Merhi, Lukas-Karim, Pousett, Brittany, Sangha, Sohail, Menon, Carlo · 2017 · IEEE Robotics & Automation Magazine

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Abstract

Despite the appearance of advanced multi-degrees of freedom (DoF) robotic hands during the past decade, prosthetic control lacks a powerful interface to facilitate all its functionalities in a manner that is acceptable for a majority of users. In this article, we explore the feasibility of using a sensing technique called force myography (FMG) as an alternative or synergist to the traditional surface electromyography (sEMG) technique as a human-machine interface (HMI) for the control of a multi-DoF prosthetic hand, bebionic 3 by Ottobock, Austin, Texas. In this article, we present a prosthetic prototype developed for the Cybathlon 2016, a championship for racing pilots with disabilities using assistive robotic devices. The design of the prototype is discussed and the effect of two factors on its control is analyzed. These factors are 1) the impact of a multisensory approach and 2) the placement of FMG sensor strips within the prosthetic inner socket. Analysis is performed by comparing resulting pattern recognition accuracies. Results show that the use of both sensing modalities (FMG and EMG) together produced the highest pattern recognition accuracy (81.1%) for ten classes of motion (four wrist movements and six grip patterns). We demonstrated that FMG has the potential to be an HMI for control of upper-limb-powered prostheses. FMG also illustrates the potential for intuitive control through the use of pattern recognition. A multisensory approach could assist in increasing ro…

Overview

Integrity signals

Registry

Crossref · 10.1109/mra.2017.2747899

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Cited by

See all 57

Metadata

Authors
Ahmadizadeh, C., Merhi, L.-K., Pousett, B., Sangha, S., & Menon, C.
Affiliations
  • Simon Fraser University (CA)
  • Barber Prosthetic Clinic, Vancouver, British Columbia, Canada
Venue
IEEE Robotics & Automation Magazine
Published
2017-12
Volume
24
Issue
4
Pages
102-111
ISSN
  • 1070-9932 (ISSN-L)
  • 1558-223X
OpenAlex
W2767382018
Cited by
57
References
18
Citations by year
2026: 2 · 2025: 3 · 2024: 9 · 2023: 6 · 2022: 11 · 2021: 10 · 2020: 4 · 2019: 9 · 2018: 3
FWCI
1.97
Type
journal article
Language
en
Open access
closed
Locations
IEEE Robotics & Automation Magazine (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
Keywords
force myography, surface electromyography, prosthetic hand control, human-machine interaction, pattern recognition, sensor placement, grip patterns, wrist kinematics, upper limb prosthesis, intuitive control

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.