The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
A microwave radio for Doppler radar sensing of vital signs
Abstract
A microwave radio for Doppler radar sensing of vital signs is described. This radio was developed using custom DCS1800/PCS1900 base station RFICs. It transmits a single tone signal, demodulates the reflected signal, and outputs a baseband signal. If the object that reflects the signal has periodic motion, the magnitude of the baseband output signal is directly proportional to the periodic displacement of the object. When the signal is reflected off a person's chest, this radio with appropriate baseband filters can detect heart and respiration rates from a distance as large as one meter from the target.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Persons With Chronic Conditions: Their Prevalence and Costs
Hoffman, C. (1996) · JAMA · doi:10.1001/jama.1996.03540180029029 · Cited by 966
Noninvasive microwave measurement of respiration
Lin, J. C. (1975) · Proceedings of the IEEE · doi:10.1109/proc.1975.9992 · Cited by 429
Self-citationMicrowave sensing of physiological movement and volume change: A review
Lin, J. C. (1992) · Bioelectromagnetics · doi:10.1002/bem.2250130610 · Cited by 299
Self-citationAn X-Band Microwave Life-Detection System
Chen, K., Misra, D. K., Wang, H., Chuang, H.-R., & Postow, E. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325760 · Cited by 284
Lin, J. C., Kiernicki, J., Kiernicki, M., & Wollschlaeger, P. B. (1979) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.1979.1129682 · Cited by 182
Self-citation
Cited by
A Review on Recent Advances in Doppler Radar Sensors for Noncontact Healthcare Monitoring
Li, C., Lubecke, V. M., Boric-Lubecke, O., & Lin, J. (2013) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2013.2256924 · Cited by 821
Self-citationDroitcour, A. D., Boric-Lubecke, O., Lubecke, V. M., Lin, J., & Kovacs, G. T. A. (2004) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2004.823552 · Cited by 662
Self-citationXiao, Y., Lin, J., Boric-Lubecke, O., & Lubecke, M. (2006) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2006.873625 · Cited by 259
Self-citationRadar remote monitoring of vital signs
Li, C., Cummings, J., Lam, J., Graves, E., & Wu, W. (2009) · IEEE Microwave Magazine · doi:10.1109/mmm.2008.930675 · Cited by 255
Signal-to-Noise Ratio in Doppler Radar System for Heart and Respiratory Rate Measurements
Droitcour, A. D., Boric-Lubecke, O., & Kovacs, G. T. A. (2009) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2009.2029668 · Cited by 162
Self-citationSeismocardiogram and Ballistocardiogram Sensing
Postolache, O., Girão, P., & Postolache, G. (2013) · Advanced Instrument Engineering · doi:10.4018/978-1-4666-4165-5.ch017 · Cited by 5
Metadata
- Authors
- Droitcour, A., Lubecke, V., Lin, J., & Boric-Lubecke, O.
- Venue
- 2001 IEEE MTT-S International Microwave Sympsoium Digest (Cat. No.01CH37157)
- Publisher
- IEEE
- Published
- 2002-11-13
- Volume
- 1
- Pages
- 175-178
- OpenAlex
- W2137355544
- Cited by
- 252
- References
- 5
- FWCI
- 4.93
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.