This paper proposes a new method for power telemetry and wireless data transfer to biomedical implants. Confinement of the transferred energy within a predefined area, hence not influencing the neighboring sensitive circuitry on the microsystem, and also allowing for more than one telemetry link on the same platform and even operating at the same carrier frequency are among the advantages of the proposed method over the traditional approaches for power and data telemetry.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Dai, J., & Ludois, D. C. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2415253 · Cited by 638
Wireless Power Transfer Strategies for Implantable Bioelectronics
Agarwal, K., Jegadeesan, R., Guo, Y.-X., & Thakor, N. V. (2017) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2683520 · Cited by 540
Wireless power transfer techniques for implantable medical devices: a review
Khan, S. R., Pavuluri, S. K., Cummins, G., & Desmulliez, M. P. Y. (2020) · Sensors · doi:10.3390/s20123487 · Cited by 355
“Non-radiative capacitive coupling (NRCC) of IMDs was first demonstrated for the powering of subcutaneous implants in [52] and was later extended to flexible implants.”
BackgroundEnergy harvesting for the implantable biomedical devices: issues and challenges
Hannan, M. A., Mutashar, S., Samad, S. A., & Hussain, A. (2014) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-13-79 · Cited by 322
A Review on the Recent Development of Capacitive Wireless Power Transfer Technology
Lu, F., Zhang, H., & Mi, C. (2017) · Energies · doi:10.3390/en10111752 · Cited by 282
Capacitive power transfer for contactless charging
Kline, M., Izyumin, I., Boser, B., & Sanders, S. (2011) · 2011 Twenty-Sixth Annual IEEE Applied Power Electronics Conference and Exposition (APEC) · doi:10.1109/apec.2011.5744775 · Cited by 277
Effective Capacitive Power Transfer
Theodoridis, M. P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2192502 · Cited by 272
Neural Dust: An Ultrasonic, Low Power Solution for Chronic Brain-Machine Interfaces
Seo, D., Carmena, J. M., Rabaey, J. M., Alon, E., & Maharbiz, M. M. (2013) · arXiv · doi:10.48550/arxiv.1307.2196 · Cited by 172
Miniaturised wireless power transfer systems for neurostimulation: a review
Barbruni, G. L., Ros, P. M., Demarchi, D., Carrara, S., & Ghezzi, D. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.3038599 · Cited by 161
Model validation of untethered, ultrasonic neural dust motes for cortical recording
Seo, D., Carmena, J. M., Rabaey, J. M., Maharbiz, M. M., & Alon, E. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.07.025 · Cited by 158
A biosafety comparison between capacitive and inductive coupling in biomedical implants
Al-Kalbani, A. I., Yuce, M. R., & Redoute, J.-M. (2014) · IEEE Antennas and Wireless Propagation Letters · doi:10.1109/lawp.2014.2328375 · Cited by 69
Modeling of capacitive resonant wireless power and data transfer to deep biomedical implants
Narayanamoorthi, R. (2019) · IEEE Transactions on Components, Packaging and Manufacturing Technology · doi:10.1109/tcpmt.2019.2922046 · Cited by 62
Comparative analysis of energy transfer mechanisms for neural implants
Miziev, S., Pawlak, W. A., & Howard, N. (2024) · Frontiers in Neuroscience · doi:10.3389/fnins.2023.1320441 · Cited by 21
Capacitive power transfer in biomedical implantable device: a review
Mustapa, M. Z. B., Saat, S., Yusof, Y., & Shaari, M. M. (2019) · International Journal of Power Electronics and Drive Systems (IJPEDS) · doi:10.11591/ijpeds.v10.i2.pp935-942 · Cited by 18
Study of midfield wireless power transfer for implantable medical devices
Keerthi., K. S., Ilango., K., & Manjula., G. N. (2018) · 2018 2nd International Conference on Biomedical Engineering (IBIOMED) · doi:10.1109/ibiomed.2018.8534820 · Cited by 17
Metadata
- Authors
- Sodagar, A. M., & Amiri, P.
- Venue
- 2009 4th International IEEE/EMBS Conference on Neural Engineering
- Publisher
- IEEE
- Published
- 2009-04
- Pages
- 411-414
- ISSN
- 1948-3554 (ISSN-L)
- OpenAlex
- W2144414216
- Cited by
- 163
- References
- 0
- FWCI
- 9.74
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.