Regenerative microchannel electrode array for peripheral nerve interfacing
The DOI matches its Crossref record; 10 of the 11 references it cites were found in a registry or an index.
Abstract
A regenerative microchannel scaffold capable of housing microelectrodes to form a high-throughput peripheral nerve interface is described. The regenerative microchannel scaffold was fabricated using polydimethylsiloxane (PDMS) and SU-8 as substrate and structural materials, respectively. This microchannel scaffold is capable of being integrated with a PDMS-based thin-film microelectrode array (MEA) to form a peripheral nerve interface. Preliminary in vitro characterization was performed using dorsal root ganglia cultures to evaluate biocompatibility and the ability of the microchannel design to direct and orient neurite outgrowth. Our findings provided evidence that the microchannel design will be effective in directing axon regeneration to the benefit of a neural interfacing device.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Microchannel-based devices guide regenerating axons and parcel outgrowth toward distinct target locations.”
From Regenerative Electrode Interfaces for Neural Prostheses. (2016) · cites this paper as [95]
Citations
Cites
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845
Dhillon, G. S., Lawrence, S. M., Hutchinson, D. T., & Horch, K. W. (2004) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2004.02.006 · Cited by 354 · cited 1×
“Next generation peripheral nerve prosthetics aim to interface with the limb‟s remaining nervous system, which remains viable and functional for years after injury [1].”
BackgroundHess, A., & Young, J. Z. (1952) · Proceedings of the Royal Society of London. Series B - Biological Sciences · doi:10.1098/rspb.1952.0063 · Cited by 153
Chronic recording of regenerating viiith nerve axons with a sieve electrode
Mensinger, A. F., Anderson, D. J., Buchko, C. J., Johnson, M. A., Martin, D. C., Tresco, P. A., Silver, R. B., & Highstein, S. M. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.83.1.611 · Cited by 76
Microchannels as Axonal Amplifiers
FitzGerald, J. J., Lacour, S. P., McMahon, S. B., & Fawcett, J. W. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.909533 · Cited by 76
High‐Density Stretchable Electronics: Toward an Integrated Multilayer Composite
Guo, L., & DeWeerth, S. P. (2010) · Advanced Materials · doi:10.1002/adma.201000515 · Cited by 58 · cited 1×
“3mm x 380μm, RHA1016, Intan Technologies, UT) has been integrated in the thick PDMS layer, and the MEA was fabricated overlay with via-bondings on contact pads of the die [8].”
MethodSelf-citationUnmyelinated Aplysia Nerves Exhibit a Nonmonotonic Blocking Response to High-Frequency Stimulation
Joseph, L., & Butera, R. J. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2029490 · Cited by 55 · cited 1×
“These include using the incorporated electrodes to induce nerve conduction blocking for pain modulation, stimulation of specific nerve fiber types using high frequency wave forms, [9, 10] and monitoring the”
MethodMicrochannel Electrodes for Recording and Stimulation:In Vitro Evaluation
FitzGerald, J. J., Lacour, S. P., McMahon, S. B., & Fawcett, J. W. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2013960 · Cited by 45
Conduction block induced by high frequency AC stimulation in unmyelinated nerves
Joseph, L., Haeffele, B. D., & Butera, R. J. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4352641 · Cited by 36
Guo, L., Clements, I. P., Li, D., Bellamkonda, R. V., & DeWeerth, S. P. (2010) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2010.5709604 · Cited by 8 · cited 1×
“To fabricate the regenerative microchannel scaffold, a 70μm PDMS (Sylgard 184, Dow Corning) base layer was first spun on glass, in which an MEA would be fabricated [7] if electrodes were to be incorporated into the scaffold.”
MethodSelf-citation
Cited by
Implantable neurotechnologies: a review of micro- and nanoelectrodes for neural recording
Patil, A. C., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1430-4 · Cited by 175
A review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133
Tissue-engineered peripheral nerve interfaces
Spearman, B. S., Desai, V. H., Mobini, S., McDermott, M. D., Graham, J. B., Otto, K. J., Judy, J. W., & Schmidt, C. E. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701713 · Cited by 96
Regenerative Electrode Interfaces for Neural Prostheses.
Thompson, C. H., Zoratti, M. J., Langhals, N. B., & Purcell, E. K. (2016) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2015.0279 · Cited by 67
Microchannel-based regenerative scaffold for chronic peripheral nerve interfacing in amputees
Srinivasan, A., Tahilramani, M., Bentley, J. T., Gore, R. K., Millard, D. C., Mukhatyar, V. J., Joseph, A., Haque, A. S., Stanley, G. B., English, A. W., et al. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2014.11.035 · Cited by 67
“fabrication of these steps can be found in literature [26].”
Self-citationRegenerative Scaffold Electrodes for Peripheral Nerve Interfacing
Clements, I. P., Mukhatyar, V. J., Srinivasan, A., Bentley, J. T., Andreasen, D. S., & Bellamkonda, R. V. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2217352 · Cited by 46
“microchannel type regenerative electrodes [15]–[18] appear to provide intermediate transparency factors, as high as 50% in one example [15].”
BackgroundSelf-citationIn Vitro, In Vivo and Ex Vivo Models for Peripheral Nerve Injury and Regeneration
Li, A., Pereira, C., Hill, E. E., Vukcevich, O., & Wang, A. (2021) · Current Neuropharmacology · doi:10.2174/1570159x19666210407155543 · Cited by 47
“Microchannel arrays have already been used for the purposes of peripheral nerve interfacing in the advancement of bioprosthetics control [137].”
BackgroundMethodSands, I., DeMarco, R. E., Thurber, L., Esteban‐Linares, A., Song, D. B., Meng, E. F., & Chen, Y. (2024) · Advanced Materials · doi:10.1002/adma.202401750 · Cited by 33
Gore, R. K., Choi, Y., Bellamkonda, R., & English, A. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016017 · Cited by 26
“…of fabrication so we are interested in exploring these simple designs compared with designs requiring much more advanced fabrication techniques to strike a balance between design performance and complexity (Srinivasan et al 2011, FitzGerald et al 2012, Minev et al 2012, Srinivasan et al in press).”
BackgroundSelf-citationSrinivasan, A., Tipton, J., Tahilramani, M., Kharbouch, A., Gaupp, E., Song, C., Venkataraman, P., Falcone, J., Lacour, S. P., Stanley, G. B., et al. (2016) · European Journal of Neuroscience · doi:10.1111/ejn.13080 · Cited by 20
“Furthermore, the formation of axon bundles in this study as compared with the lack thereof in the previous studies is attributed to the 100-lm-wide microchannels used here, as opposed to the 50-lm-wide or 75-lm-wide microchannels used previously (Srinivasan et al., 2011, 2015).”
ResultSelf-citationCoker, R., Zellmer, E. R., & Moran, D. W. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaefcf · Cited by 12
Handcrafted multilayer PDMS microchannel scaffolds for peripheral nerve regeneration
Hossain, R. F., Kim, B., Pankratz, R., Ajam, A., Park, S., Biswal, S. L., & Choi, Y. (2015) · Biomedical Microdevices · doi:10.1007/s10544-015-0012-4 · Cited by 10
Coker, R. (2017) · Open Scholarship Institutional Repository (Washington University in St. Louis) · doi:10.7936/k7sj1k09
Design and fabrication of a next generation regenerative neural interface
Churm, J. (2018) · University of Birmingham Institutional Research Archive (University of Birmingham)
Santos, D. V. V., Navarro, X., Cel·lular, D. F. I. D. U. A. D. B. D. D. B., & de Neurociències, U. A. D. B. I. (2016) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas)
Metadata
- Authors
- Srinivasan, A., Guo, L., & Bellamkonda, R. V.
- Affiliations
- Georgia Institute of Technology (US)
- Venue
- 2011 5th International IEEE/EMBS Conference on Neural Engineering
- Publisher
- IEEE
- Published
- 2011-04
- Pages
- 253-256
- ISSN
- 1948-3554 (ISSN-L)
- OpenAlex
- W2145008294
- Cited by
- 12
- References
- 11
- Citations by year
- 2024: 1 · 2021: 1 · 2019: 1 · 2018: 1 · 2017: 1 · 2016: 1 · 2015: 4 · 2014: 1 · 2012: 1
- FWCI
- 1.81
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- International IEEE/EMBS Conference on Neural Engineering (publishedVersion)
- Funders
- National Science Foundation
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Nerve injury and regeneration
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Keywords
- peripheral nerve interfaces, microelectrode arrays, axon regeneration, neurite outgrowth, dorsal root ganglia, biocompatibility, polydimethylsiloxane, SU-8
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.