Functional recordings from awake, behaving rodents through a microchannel based regenerative neural interface
Open accessAbstract
OBJECTIVE: Neural interface technologies could provide controlling connections between the nervous system and external technologies, such as limb prosthetics. The recording of efferent, motor potentials is a critical requirement for a peripheral neural interface, as these signals represent the user-generated neural output intended to drive external devices. Our objective was to evaluate structural and functional neural regeneration through a microchannel neural interface and to characterize potentials recorded from electrodes placed within the microchannels in awake and behaving animals. APPROACH: Female rats were implanted with muscle EMG electrodes and, following unilateral sciatic nerve transection, the cut nerve was repaired either across a microchannel neural interface or with end-to-end surgical repair. During a 13 week recovery period, direct muscle responses to nerve stimulation proximal to the transection were monitored weekly. In two rats repaired with the neural interface, four wire electrodes were embedded in the microchannels and recordings were obtained within microchannels during proximal stimulation experiments and treadmill locomotion. MAIN RESULTS: In these proof-of-principle experiments, we found that axons from cut nerves were capable of functional reinnervation of distal muscle targets, whether regenerating through a microchannel device or after direct end-to-end repair. Discrete stimulation-evoked and volitional potentials were recorded within interface microchannels in a small group of awake and behaving animals and their firing patterns correlated directly with intramuscular recordings during locomotion. Of 38 potentials extracted, 19 were identified as motor axons reinnervating tibialis anterior or soleus muscles using spike triggered averaging. SIGNIFICANCE: These results are evidence for motor axon regeneration through microchannels and are the first report of in vivo recordings from regenerated motor axons within microchannels in a small group of awake and behaving animals. These unique findings provide preliminary evidence that efferent, volitional motor potentials can be recorded from the microchannel-based peripheral neural interface; a critical requirement for any neural interface intended to facilitate direct neural control of external technologies.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Studies have achieved long-term recordings in freely moving animals using microchannel devices for periods 4 months post-implantation, while only small signals in response to electrical stimulation have been recorded at such chronic timepoint with sieve electrodes.
“Studies have achieved long-term recordings in freely moving animals using microchannel devices for periods 4 months post-implantation (Gore et al., 2015), while only small signals in response to electrical stimulation have been recorded at such chronic timepoint with sieve electrodes (Ramachandran et al., 2006).”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Gore et al., 2015
Split into 2 atoms — 1 confirmed, 1 partially supported, 0 disputed, 0 misattributed, 0 unverifiable. Expand the claim to see per-atom verdicts.
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896 · see citing works
Muscles Alive—their functions revealed by electromyography
(1963) · Postgraduate Medical Journal · doi:10.1136/pgmj.39.449.162-b · Cited by 1,780 · see citing works
The role of aligned polymer fiber-based constructs in the bridging of long peripheral nerve gaps
Kim, Y.-T., Haftel, V. K., Kumar, S., & Bellamkonda, R. V. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.03.042 · Cited by 452 · see citing works
Dhillon, G. S., Lawrence, S. M., Hutchinson, D. T., & Horch, K. W. (2004) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2004.02.006 · Cited by 354 · cited 1× · see citing works
“The peripheral nerve is one target for such bidirectional interfacing, with renewed interest generated by reports that peripheral neural tissue is viable for interfacing even years after injury or amputation (Dhillon et al 2004).”
BackgroundLong-term stimulation and recording with a penetrating microelectrode array in cat sciatic nerve
Branner, A., Stein, R. B., Fernandez, E., Aoyagi, Y., & Normann, R. A. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.820321 · Cited by 301 · see citing works
Selective Electrical Interfaces with the Nervous System
Rutten, W. L. C. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.020702.153427 · Cited by 276 · see citing works
Complications of deep brain stimulation surgery
Hariz, M. I. (2002) · Movement Disorders · doi:10.1002/mds.10159 · Cited by 267 · see citing works
Flexible and stretchable micro-electrodes for in vitro and in vivo neural interfaces
Lacour, S. P., Benmerah, S., Tarte, E. J., FitzGerald, J. J., Serra, J., McMahon, S. B., Fawcett, J. W., Graudejus, O., Yu, Z., & Morrison, B. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0644-8 · Cited by 265 · see citing works
Badia, J., Boretius, T., Andreu, D., Azevedo-Coste, C., Stieglitz, T., & Navarro, X. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/036023 · Cited by 227 · see citing works
Lago, N., Ceballos, D., J Rodrı́guez, F., Stieglitz, T., & Navarro, X. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.06.025 · Cited by 178 · see citing works
Edell, D. J. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325892 · Cited by 177 · see citing works
Treadmill training promotes axon regeneration in injured peripheral nerves
Sabatier, M. J., Redmon, N., Schwartz, G., & ENGLISH, A. W. (2008) · Experimental Neurology · doi:10.1016/j.expneurol.2008.02.013 · Cited by 160 · see citing works
Stable long-term recordings from cat peripheral nerves
Stein, R. B., Nichols, T. R., Jhamandas, J., Davis, L., & Charles, D. (1977) · Brain Research · doi:10.1016/0006-8993(77)90233-5 · Cited by 160 · see citing works
A micromachined silicon sieve electrode for nerve regeneration applications
Akin, T., Najafi, K., Smoke, R. H., & Bradley, R. M. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.284958 · Cited by 144 · see citing works
Thin-film enhanced nerve guidance channels for peripheral nerve repair
Clements, I. P., Kim, Y.-T., ENGLISH, A. W., Lu, X., Chung, A., & Bellamkonda, R. V. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.04.022 · Cited by 131 · see citing works
Operant conditioning of H-reflex in freely moving rats
Chen, X. Y., & Wolpaw, J. R. (1995) · Journal of Neurophysiology · doi:10.1152/jn.1995.73.1.411 · Cited by 128 · see citing works
Activity of Hindlimb Motor Units During Locomotion in the Conscious Rat
Gorassini, M. A., Eken, T., Bennett, D. J., Kiehn, O., & Hultborn, H. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.83.4.2002 · Cited by 112 · see citing works
Foehring, R. C., Sypert, G. W., & Munson, J. B. (1986) · Journal of Neurophysiology · doi:10.1152/jn.1986.55.5.947 · Cited by 109 · see citing works
(1998) · PubMed · Cited by 107 · see citing works
Dominici, N., Keller, U., Vallery, H., Friedli, L., van den Brand, R., Starkey, M. L., Евгеньевич, М. П., Riener, R., & Courtine, G. (2012) · Nature Medicine · doi:10.1038/nm.2845 · Cited by 105 · see citing works
ENGLISH, A. W. (2005) · The Journal of Comparative Neurology · doi:10.1002/cne.20678 · Cited by 98 · see citing works
H reflex restitution and facilitation after different types of peripheral nerve injury and repair
Valero‐Cabré, A., & Navarro, X. (2001) · Brain Research · doi:10.1016/s0006-8993(01)03052-9 · Cited by 88 · see citing works
Mannard, A., Stein, R. B., & Charles, D. (1974) · Science · doi:10.1126/science.183.4124.547 · Cited by 85 · see citing works
MUSCLES ALIVE-THEIR FUNCTIONS REVEALED BY ELECTROMYOGRAPHY
deVries, H. A. (1976) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-197621000-00002 · Cited by 82 · see citing works
Chronic recording of regenerating viiith nerve axons with a sieve electrode
Mensinger, A. F., Anderson, D. J., Buchko, C. J., Johnson, M. A., Martin, D. C., Tresco, P. A., Silver, R. B., & Highstein, S. M. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.83.1.611 · Cited by 76 · see citing works
FitzGerald, J. J., Lago, N., Benmerah, S., Serra, J., Watling, C. P., Cameron, R. E., Tarte, E., Lacour, S. P., McMahon, S. B., & Fawcett, J. W. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/1/016010 · Cited by 73 · see citing works
Microchannel-based regenerative scaffold for chronic peripheral nerve interfacing in amputees
Srinivasan, A., Tahilramani, M., Bentley, J. T., Gore, R. K., Millard, D. C., Mukhatyar, V. J., Joseph, A., Haque, A. S., Stanley, G. B., English, A. W., et al. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2014.11.035 · Cited by 67 · see citing works
Rat sciatic nerve regeneration through a micromachined silicon chip
Zhao, Q., Drott, J., Laurell, T., Wallman, L., Lindström, K., Bjursten, L. M., Lundborg, G., Montelius, L., & Danielsen, N. (1997) · Biomaterials · doi:10.1016/s0142-9612(96)00112-3 · Cited by 67 · see citing works
Effects of treadmill training on functional recovery following peripheral nerve injury in rats
Boeltz, T., Ireland, M., Mathis, K., Nicolini, J., Poplavski, K., Rose, S. J., Wilson, E., & ENGLISH, A. W. (2013) · Journal of Neurophysiology · doi:10.1152/jn.00946.2012 · Cited by 65 · see citing works
Klinge, P. M., Vafa, M. A., Brinker, T., Brandis, A., Walter, G. F., Stieglitz, T., Samii, M., & Wewetzer, K. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00420-8 · Cited by 64 · see citing works
Castro, J., Negredo, P., & Avendaño, C. (2008) · Brain Research · doi:10.1016/j.brainres.2007.11.028 · Cited by 63 · see citing works
Ceballos, D., Valero‐Cabré, A., Valderrama, E., Schüttler, M., Stieglitz, T., & Navarro, X. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10099 · Cited by 61 · see citing works
Polyimide micro-channel arrays for peripheral nerve regenerative implants
Lacour, S. P., Atta, R., FitzGerald, J. J., Blamire, M., Tarte, E., & Fawcett, J. (2008) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2008.05.031 · Cited by 56 · see citing works
Early interfaced neural activity from chronic amputated nerves
Garde, K. (2009) · Frontiers in Neuroengineering · doi:10.3389/neuro.16.005.2009 · Cited by 56 · see citing works
ENGLISH, A. W., Chen, Y., Carp, J. S., Wolpaw, J. R., & Chen, X. Y. (2006) · Journal of Neurophysiology · doi:10.1152/jn.01035.2006 · Cited by 48 · see citing works
Ramachandran, A., Schuettler, M., Lago, N., Doerge, T., Koch, K. P., Navarro, X., Hoffmann, K.-P., & Stieglitz, T. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/2/005 · Cited by 46 · see citing works
Regenerative Scaffold Electrodes for Peripheral Nerve Interfacing
Clements, I. P., Mukhatyar, V. J., Srinivasan, A., Bentley, J. T., Andreasen, D. S., & Bellamkonda, R. V. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2217352 · Cited by 46 · see citing works
Microchannel Electrodes for Recording and Stimulation: In Vitro Evaluation
FitzGerald, J. J., Lacour, S. P., McMahon, S. B., & Fawcett, J. W. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2013960 · Cited by 45 · see citing works
Serra, J., Bostock, H., & Navarro, X. (2009) · Neuroscience Letters · doi:10.1016/j.neulet.2009.09.061 · Cited by 38 · see citing works
Minev, I. R., Chew, D. J., Delivopoulos, E., Fawcett, J. W., & Lacour, S. P. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/2/026005 · Cited by 36 · see citing works
Sabatier, M. J., To, B. N., Nicolini, J., & ENGLISH, A. W. (2011) · Cells Tissues Organs · doi:10.1159/000323677 · Cited by 35 · see citing works
Peripheral Nerve Repair Through Multi-Luminal Biosynthetic Implants
Tansey, K. E., Seifert, J. L., Botterman, B. R., Delgado, M. R., & Romero‐Ortega, M. I. (2011) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0277-6 · Cited by 30 · see citing works
Evaluation of the long‐term regenerative potential in an experimental nerve amputee model
Lago, N., & Navarro, X. (2007) · Journal of the Peripheral Nervous System · doi:10.1111/j.1529-8027.2007.00130.x · Cited by 22 · see citing works
Stoyanova, I. I., van Wezel, R. J. A., & Rutten, W. L. C. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/6/066018 · Cited by 18 · see citing works
Neural prostheses in clinical practice: biomedical microsystems in neurological rehabilitation
Stieglitz, T. (2007) · Springer eBooks · doi:10.1007/978-3-211-33079-1_54 · Cited by 17 · see citing works
Wieringa, P. A., Wiertz, R. W. F., de Weerd, E. L., & Rutten, W. L. C. (2010) · Proceedings of the IEEE · doi:10.1109/jproc.2009.2038950 · Cited by 13 · see citing works
Regenerative microchannel electrode array for peripheral nerve interfacing
Srinivasan, A., Guo, L., & Bellamkonda, R. V. (2011) · 2011 5th International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2011.5910535 · Cited by 12 · see citing works
Flexible Multikanal-Mikroelektroden mit integrierten Zuleitungen zum Einsatz in der Neuroprothetik
Stieglitz, T., Beutel, H., Blau, C., & Meyer, J.-U. (1997) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmte.1997.42.s2.449 · Cited by 8 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics
Carnicer-Lombarte, A., Chen, S.-T., Malliaras, G. G., & Barone, D. G. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.622524 · Cited by 454 · see citing works
“Studies have achieved long-term recordings in freely moving animals using microchannel devices for periods 4 months postimplantation (Gore et al., 2015), while only small signals in response to electrical stimulation have been recorded at such chronic timepoint with sieve electrodes (Ramachandran et al.”
BackgroundA review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133 · see citing works
Flexible fiber-based optoelectronics for neural interfaces
Park, S., Loke, G. Z. J., Fink, Y., & Anikeeva, P. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00710a · Cited by 134 · see citing works
Lee, B., Koripalli, M. K., Jia, Y., Acosta, J., Sendi, M. S. E., Choi, Y., & Ghovanloo, M. (2018) · Scientific Reports · doi:10.1038/s41598-018-24465-1 · Cited by 118 · see citing works
Multifunctional Fibers as Tools for Neuroscience and Neuroengineering
Canales, A., Park, S., Kilias, A., & Anikeeva, P. (2018) · Accounts of Chemical Research · doi:10.1021/acs.accounts.7b00558 · Cited by 102 · see citing works
Tissue-engineered peripheral nerve interfaces
Spearman, B. S., Desai, V. H., Mobini, S., McDermott, M. D., Graham, J. B., Otto, K. J., Judy, J. W., & Schmidt, C. E. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701713 · Cited by 96 · see citing works
The Evolution of Neuroprosthetic Interfaces
Adewole, D. O., Serruya, M. D., Harris, J. P., Burrell, J. C., Petrov, D., Chen, H.-C. I., Wolf, J. A., & Cullen, D. K. (2016) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.2016017198 · Cited by 81 · see citing works
Chronic multichannel neural recordings from soft regenerative microchannel electrodes during gait
Musick, K. M., Rigosa, J., Narasimhan, S., Wurth, S., Capogrosso, M., Chew, D. J., Fawcett, J. W., Micera, S., & Lacour, S. P. (2015) · Scientific Reports · doi:10.1038/srep14363 · Cited by 70 · see citing works
<i>In vivo</i> characterization of regenerative peripheral nerve interface function
Ursu, D. C., Urbanchek, M. G., Nedic, A., Cederna, P. S., & Gillespie, R. B. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/026012 · Cited by 46 · see citing works
Srinivasan, A., Tipton, J., Tahilramani, M., Kharbouch, A., Gaupp, E. A., Song, C. L., Venkataraman, P., Falcone, J., Lacour, S. P., Stanley, G. B., et al. (2015) · European Journal of Neuroscience · doi:10.1111/ejn.13080 · Cited by 20 · see citing works
Lim, J., Zoss, P., Powley, T. L., Lee, H., & Ward, M. P. (2024) · Microsystems & Nanoengineering · doi:10.1038/s41378-023-00637-6 · Cited by 16 · see citing works
Ursu, D. C., Nedic, A., Urbanchek, M. G., Cederna, P. S., & Gillespie, R. B. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0243-0 · Cited by 16 · see citing works
An ASIC for Recording and Stimulation in Stacked Microchannel Neural Interfaces
Lancashire, H. T., Jiang, D., Demosthenous, A., & Donaldson, N. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2891284 · Cited by 15 · see citing works
Microchannel neural interface manufacture by stacking silicone and metal foil laminae
Lancashire, H. T., Vanhoestenberghe, A., Pendegrass, C. J., Ajam, Y. A., Magee, E., Donaldson, N., & Blunn, G. W. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/034001 · Cited by 13 · see citing works
Kang, Y. N., Chou, N., Jang, J., Byun, D., Kang, H., Moon, D.-J., Kim, J., & Kim, S. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2917916 · Cited by 13 · see citing works
Coker, R., Zellmer, E. R., & Moran, D. W. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaefcf · Cited by 11 · see citing works
Multisite Simultaneous Neural Recording of Motor Pathway in Free-Moving Rats
Lang, Y., Tang, R., Liu, Y., Xi, P., Liu, H., Quan, Z., Song, D. F., Lv, X., Huang, Q., & He, J. (2021) · Biosensors · doi:10.3390/bios11120503 · Cited by 10 · see citing works
Hoang, M. D., Kang, W., Koh, M., & Park, S. (2025) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2025.3564625 · Cited by 6 · see citing works
Zhang, M., Zhao, Z., Ma, Y., Zhang, C., Song, W., Lei, J., & Xie, C. (2023) · IEEE Solid-State Circuits Magazine · doi:10.1109/mssc.2023.3312227 · Cited by 4 · see citing works
Headers and Payloads Inside of Nervous System as Like as Digital Communication Protocols ?
Jáuregui, O. N., & Leyva-Montiel, J. (2017) · International journal of Biomedical Engineering and Science · doi:10.5121/ijbes.2017.4103 · Cited by 1 · see citing works
Microfluidic components, devices and integrated lab-on-a-chip systems
Lüttge, R. (2016) · Elsevier eBooks · doi:10.1016/b978-0-323-37828-4.00007-8 · Cited by 1 · see citing works
Ajam, A., & Hossain, R. F. (2015) · International Journal of Sensor Networks and Data Communications · doi:10.4172/2090-4886.1000133 · Cited by 1 · see citing works
Regenerative Neural Electrodes
Guzman, G., Rafaqut, M. S., Park, S., & Choi, P. Y. (2020) · Springer eBooks · doi:10.1007/978-3-030-41854-0_11 · Cited by 1 · see citing works
Falcone, J. D., Liu, T. G., Goldman, L., Pogue, D. D., Straka, M., Rieth, L., Bouton, C., & Sohal, H. (2018) · bioRxiv · doi:10.1101/402925 · Cited by 1 · see citing works
Coker, R. (2017) · Open Scholarship Institutional Repository (Washington University in St. Louis) · doi:10.7936/k7sj1k09
Improving Suturing Skills for Surgical Residents and Advancing Prosthesis Control for Amputees.
Ursu, D. C. (2016) · Deep Blue (University of Michigan)
- Authors
- Gore, R. K., Choi, Y., Bellamkonda, R., & English, A.
- Affiliations
- Georgia Institute of Technology (US)
- The University of Texas System (US)
- Emory University (US)
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2015-01-21
- Volume
- 12
- Issue
- 1
- Pages
- 016017
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- PMC
- PMC4324563
- OpenAlex
- W2009867546
- Cited by
- 26
- References
- 48
- Citations by year
- 2025: 1 · 2024: 1 · 2023: 1 · 2021: 2 · 2020: 1 · 2019: 4 · 2018: 4 · 2017: 4 · 2016: 5 · 2015: 3
- FWCI
- 2.48
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institutes of Health (NS065109 (RVB))
- National Institute of Neurological Disorders and Stroke (R25 (RKG))
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Nerve injury and regeneration
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- motor axon regeneration, sciatic nerve transection, treadmill locomotion, tibialis anterior, soleus muscle, spike-triggered averaging, functional reinnervation, artificial limbs
- MeSH terms
- Action Potentials, Animals, Electrodes, Implanted, Female, Nerve Regeneration, Neural Conduction, Prosthesis Design, Rats, Inbred Lew, Sensitivity and Specificity, Reproducibility of Results, Monitoring, Ambulatory, Equipment Failure Analysis, Guided Tissue Regeneration, Rats, Tissue Scaffolds
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review