Clinical Applications of Brain-Computer Interfaces: Current State and Future Prospects
Open accessThe DOI matches its Crossref record; 136 of the 136 references it cites were found in a registry or an index.
Abstract
Brain-computer interfaces (BCIs) allow their users to communicate or control external devices using brain signals rather than the brain's normal output pathways of peripheral nerves and muscles. Motivated by the hope of restoring independence to severely disabled individuals and by interest in further extending human control of external systems, researchers from many fields are engaged in this challenging new work. BCI research and development have grown explosively over the past two decades. Efforts have recently begun to provide laboratory-validated BCI systems to severely disabled individuals for real-world applications. In this review, we discuss the current status and future prospects of BCI technology and its clinical applications. We will define BCI, review the BCI-relevant signals from the human brain, and describe the functional components of BCIs. We will also review current clinical applications of BCI technology, and identify potential users and potential applications. Finally, we will discuss current limitations of BCI technology, impediments to its widespread clinical use, and expectations for the future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927 · cited 1×
“Although most of the published BCI literature to date concerns development of improved signal processing or other engineering facets of BCI technology, incorporation of professionals from all the above mentioned disciplines is critical for success [135].”
BackgroundSelf-citationNeuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295 · cited 1×
“However, both methods require surgery, and issues such as risk of tissue damage and infection and long-term recording stability arise [18], [30].”
BackgroundFarwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228 · cited 21×
“The third major type of EEG-based BCI communication uses the well-studied P300 evenrelated brain potential [6,11] to indicate the response to a salient or infrequent stimulus within a stream of frequent standard stimuli.”
BackgroundMethodInfluentialEvoked-potential correlates of stimulus uncertainty
Sutton, S., Braren, M., Zubin, J., & John, E. R. (1965) · Science · doi:10.1126/science.150.3700.1187 · Cited by 3,061
WALTER, W. G., COOPER, R., ALDRIDGE, V. J., McCALLUM, W. C., & WINTER, A. L. (1964) · Nature · doi:10.1038/203380a0 · Cited by 2,446
Brain-computer interface technology: a review of the first international meeting
Wolpaw, J. R., Birbaumer, N., Heetderks, W. J., McFarland, D. J., Peckham, P. H., Schalk, G., Donchin, E., Quatrano, L. A., Robinson, C. J., & Vaughan, T. M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/tre.2000.847807 · Cited by 2,324
Self-citationBrain–machine interfaces: past, present and future
Lebedev, M. A., & Nicolelis, M. A. L. (2006) · Trends in Neurosciences · doi:10.1016/j.tins.2006.07.004 · Cited by 1,875 · cited 1×
“…computer screen through letter selection [5], [11], to move a cursor on a computer screen [12], [84], [85], to drive a wheelchair [86], [87] or other assistive devices [88], to manipulate a robotic arm [89], [90], or even to control movement of a paralyzed arm through a neuroprosthesis [15], [91].”
BackgroundElectroencephalography: Basic Principles, Clinical Applications and Related Fields
Torres, F. (1983) · Archives of Neurology · doi:10.1001/archneur.1983.04050030085025 · Cited by 1,812
A spelling device for the paralysed
Birbaumer, N., Ghanayim, N., Hinterberger, T., Iversen, I., Kotchoubey, B., Kübler, A., Perelmouter, J., Taub, E., & Flor, H. (1999) · Nature · doi:10.1038/18581 · Cited by 1,577 · cited 1×
“Based on this principle, Bir-baumer et al. developed an early BCI-controlled spelling device [10], [101].”
MethodDirect Cortical Control of 3D Neuroprosthetic Devices
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2002) · Science · doi:10.1126/science.1070291 · Cited by 1,540
Cited by
The grand challenges of Science Robotics
Yang, G.-Z., Bellingham, J., Dupont, P. E., Fischer, P., Floridi, L., Full, R., Jacobstein, N., Kumar, V., McNutt, M., Merrifield, R., et al. (2018) · Science Robotics · doi:10.1126/scirobotics.aar7650 · Cited by 1,177
Combining brain-computer interfaces and assistive technologies: state-of-the-art and challenges
Millán, J. D. R. (2010) · Frontiers in Neuroscience · doi:10.3389/fnins.2010.00161 · Cited by 866
Brain-Computer Interfaces in Medicine
Shih, J. J., Krusienski, D. J., & Wolpaw, J. R. (2012) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2011.12.008 · Cited by 724
Self-citationBrain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
Rehabilitation of gait after stroke: a review towards a top-down approach
Belda-Lois, J.-M., Mena-del Horno, S., Bermejo-Bosch, I., Moreno, J. C., Pons, J. L., Farina, D., Iosa, M., Molinari, M., Tamburella, F., Ramos, A., et al. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-66 · Cited by 581
Gruzelier, J. H. (2014) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2013.09.015 · Cited by 575
Visual and Auditory Brain–Computer Interfaces
Gao, S., Wang, Y., Gao, X., & Hong, B. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2300164 · Cited by 449
EEG-Based Brain-Controlled Mobile Robots: A Survey
Bi, L., Fan, X.-A., & Liu, Y. (2013) · IEEE Transactions on Human-Machine Systems · doi:10.1109/tsmcc.2012.2219046 · Cited by 386
Progress in Brain Computer Interface: Challenges and Opportunities
Saha, S., Mamun, K. A., Ahmed, K., Mostafa, R., Naik, G. R., Darvishi, S., Khandoker, A. H., & Baumert, M. (2021) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2021.578875 · Cited by 365
Summary of over Fifty Years with Brain-Computer Interfaces—A Review
Kawala-Sterniuk, A., Browarska, N., Al-Bakri, A., Pelc, M., Zygarlicki, J., Sidikova, M., Martinek, R., & Gorzelanczyk, E. J. (2021) · Brain Sciences · doi:10.3390/brainsci11010043 · Cited by 292
Ang, K. K., Guan, C., Chua, K. S. G., Ang, B. T., Kuah, C., Wang, C., Phua, K. S., Chin, Z. Y., & Zhang, H. (2010) · 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology · doi:10.1109/iembs.2010.5626782 · Cited by 237
“However, clinical applications of BCI in neurorehabilitation have just begun to be explored [10].”
BackgroundEffects of user mental state on EEG-BCI performance
Myrden, A., & Chau, T. (2015) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2015.00308 · Cited by 211
“Brain-computer interfaces allow information to be conveyed to an external device, such as a computer, using cognitive activity alone (Mak and Wolpaw, 2009).”
BackgroundBCI Demographics II: How Many (and What Kinds of) People Can Use a High-Frequency SSVEP BCI?
Volosyak, I., Valbuena, D., Luth, T., Malechka, T., & Graser, A. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2121919 · Cited by 175
“Nowadays, the most commonly used EEG-based BCI systems employ event-related synchronization of mu and beta bands, event-related potentials and steady-state visual evoked potential (SSVEP) [7], [8].”
MethodBorra, D., Fantozzi, S., & Magosso, E. (2020) · Neural Networks · doi:10.1016/j.neunet.2020.05.032 · Cited by 145
Sensors and Decoding for Intracortical Brain Computer Interfaces
Homer, M. L., Nurmikko, A. V., Donoghue, J. P., & Hochberg, L. R. (2013) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071910-124640 · Cited by 121
Doing things with thoughts: brain–computer interfaces and disembodied agency
Steinert, S., Bublitz, C., Jox, R., & Friedrich, O. (2019) · Philosophy & Technology · doi:10.1007/s13347-018-0308-4 · Cited by 117
Höhne, J., Holz, E., Staiger-Sälzer, P., Müller, K.-R., Kübler, A., & Tangermann, M. (2014) · PLoS ONE · doi:10.1371/journal.pone.0104854 · Cited by 85
“Some examples can be found in [4,11,34,36–44], also being reviewed in [12,45,46].”
BackgroundVerbal communication impacts quality of life in patients with amyotrophic lateral sclerosis
Felgoise, S. H., Zaccheo, V., Duff, J., & Simmons, Z. (2016) · Amyotrophic Lateral Sclerosis and Frontotemporal Degeneration · doi:10.3109/21678421.2015.1125499 · Cited by 81
Metadata
- Authors
- Mak, J. N., & Wolpaw, J. R.
- Venue
- IEEE Reviews in Biomedical Engineering
- Published
- 2009
- Volume
- 2
- Pages
- 187-199
- ISSN
- 1937-3333 (ISSN-L)
- 1941-1189
- OpenAlex
- W2107549039
- Cited by
- 509
- References
- 136
- FWCI
- 9.59
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.