Wireless Power Transfer Strategies for Implantable Bioelectronics
Abstract
Neural implants have emerged over the last decade as highly effective solutions for the treatment of dysfunctions and disorders of the nervous system. These implants establish a direct, often bidirectional, interface to the nervous system, both sensing neural signals and providing therapeutic treatments. As a result of the technological progress and successful clinical demonstrations, completely implantable solutions have become a reality and are now commercially available for the treatment of various functional disorders. Central to this development is the wireless power transfer (WPT) that has enabled implantable medical devices (IMDs) to function for extended durations in mobile subjects. In this review, we present the theory, link design, and challenges, along with their probable solutions for the traditional near-field resonant inductively coupled WPT, capacitively coupled short-ranged WPT, and more recently developed ultrasonic, mid-field, and far-field coupled WPT technologies for implantable applications. A comparison of various power transfer methods based on their power budgets and WPT range follows. Power requirements of specific implants like cochlear, retinal, cortical, and peripheral are also considered and currently available IMD solutions are discussed. Patient's safety concerns with respect to electrical, biological, physical, electromagnetic interference, and cyber security from an implanted neurotech device are also explored in this review. Finally, we discuss and anticipate future developments that will enhance the capabilities of current-day wirelessly powered implants and make them more efficient and integrable with other electronic components in IMDs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Antenna Theory: Analysis and Design
Balanis, C. A. (1982) · Cited by 10,178
Pozar, D. M. (1990) · Cited by 8,676
Wireless Power Transfer via Strongly Coupled Magnetic Resonances
Kurs, A., Karalis, A., Moffatt, R., Joannopoulos, J. D., Fisher, P., & Soljačić, M. (2007) · Science · doi:10.1126/science.1143254 · Cited by 5,576
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/002 · Cited by 4,270
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/003 · Cited by 4,175 · cited 2×
“on the dielectric properties of human tissues [107] is derived in [38].”
BackgroundPhysical limitations of omnidirectional antennas
(1948) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 2,235
Class E-A new class of high-efficiency tuned single-ended switching power amplifiers
Sokal, N. O., & Sokal, A. D. (1975) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1975.1050582 · Cited by 2,033
Brain–machine interfaces: past, present and future
Lebedev, M. A., & Nicolelis, M. A. L. (2006) · Trends in Neurosciences · doi:10.1016/j.tins.2006.07.004 · Cited by 1,875 · cited 1×
“Cardiac [1], cochlear [2], spinal [3], retinal [4], motor [5], and cortical [6] implants have seen unprecedented growth in the last two decades to have functionality, form factor, and packaging suitable for chronic implantation.”
BackgroundSample, A. P., Meyer, D. A., & Smith, J. R. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2046002 · Cited by 1,808
The History of Power Transmission by Radio Waves
Brown, W. C. (1984) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.1984.1132833 · Cited by 1,638
Kaul, R. (1989) · IEEE Potentials · doi:10.1109/45.31588 · Cited by 1,503
Xu, S., Zhang, Y., Cho, J., Lee, J., Huang, X., Jia, L., Fan, J. A., Su, Y., Su, J., Zhang, H., et al. (2013) · Nature Communications · doi:10.1038/ncomms2553 · Cited by 1,404
Efficient wireless non-radiative mid-range energy transfer
Karalis, A., Joannopoulos, J. D., & Soljačić, M. (2008) · Annals of Physics · doi:10.1016/j.aop.2007.04.017 · Cited by 1,394
Wang, C.-S., Covic, G. A., & Stielau, O. H. (2004) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2003.822038 · Cited by 1,213
Injectable, Cellular-Scale Optoelectronics with Applications for Wireless Optogenetics
Kim, T.-I., McCall, J. G., Jung, Y. H., Huang, X., Siuda, E. R., Li, Y., Song, J., Song, Y. M., Pao, H. A., Kim, R.-H., et al. (2013) · Science · doi:10.1126/science.1232437 · Cited by 1,174
Idealized operation of the class E tuned power amplifier
Raab, F. H. (1977) · IEEE Transactions on Circuits and Systems · doi:10.1109/tcs.1977.1084296 · Cited by 979
Conformal piezoelectric energy harvesting and storage from motions of the heart, lung, and diaphragm
Dagdeviren, C., Yang, B. D., Su, Y., Tran, P. L., Joe, P., Anderson, E., Xia, J., Doraiswamy, V., Dehdashti, B., Feng, X., et al. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1317233111 · Cited by 975
RamRakhyani, A. K., Mirabbasi, S., & Chiao, M. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2072782 · Cited by 945
Cannon, B. L., Hoburg, J. F., Stancil, D. D., & Goldstein, S. C. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2017195 · Cited by 924
Power from the Sun: Its Future
Glaser, P. E. (1968) · Science · doi:10.1126/science.162.3856.857 · Cited by 918
Cochlear Implants: System Design, Integration, and Evaluation
Zeng, F.-G., Rebscher, S., Harrison, W., Sun, X., & Feng, H. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008250 · Cited by 878
Nonionizing electromagnetic wave effects in biological materials and systems
Johnson, C. C., & Guy, A. W. (1972) · Proceedings of the IEEE · doi:10.1109/proc.1972.8728 · Cited by 851
A low-power integrated circuit for a wireless 100-electrode neural recording system.
Harrison, R. R., Watkins, P. T., Kier, R. J., Lovejoy, R. O., Black, D. J., Greger, B., & Solzbacher, F. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2006.886567 · Cited by 782
Fundamentals of Physical Acoustics
Blackstock, D. T., & Atchley, A. A. (2001) · The Journal of the Acoustical Society of America · doi:10.1121/1.1354982 · Cited by 761
Implanted Antennas Inside a Human Body: Simulations, Designs, and Characterizations
Kim, J., & Rahmat-Samii, Y. (2004) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2004.832018 · Cited by 757
A Low-Power Integrated Circuit for a Wireless 100-Electrode Neural Recording System
Harrison, R., Watkins, P., Kier, R., Lovejoy, R., Black, D., Normann, R., & Solzbacher, F. (2006) · 2006 IEEE International Solid State Circuits Conference - Digest of Technical Papers · doi:10.1109/isscc.2006.1696288 · Cited by 731
Remote Excitation of Neuronal Circuits Using Low-Intensity, Low-Frequency Ultrasound
Tyler, W. J., Tufail, Y., Finsterwald, M., Tauchmann, M. L., Olson, E. J., & Majestic, C. (2008) · PLoS ONE · doi:10.1371/journal.pone.0003511 · Cited by 707
Antennas and Propagation for Body Centric Wireless Communications
Hao, Y., Alomainy, A., Hall, P. S., Nechayev, Y. I., Parini, C. G., & Constantinou, C. C. (2005) · IEEE/ACES International Conference on Wireless Communications and Applied Computational Electromagnetics, 2005. · doi:10.1109/wcacem.2005.1469656 · Cited by 606
Design and Optimization of a 3-Coil Inductive Link for Efficient Wireless Power Transmission
Kiani, M., Jow, U.-M., & Ghovanloo, M. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2158431 · Cited by 591
A Frequency Control Method for Regulating Wireless Power to Implantable Devices
Si, P., Hu, A. P., Malpas, S., & Budgett, D. (2008) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2008.918284 · Cited by 582
Enhanced recognition memory following vagus nerve stimulation in human subjects
Clark, K. B., Naritoku, D. K., Smith, D. C., Browning, R. A., & Jensen, R. A. (1999) · Nature Neuroscience · doi:10.1038/4600 · Cited by 576
Wireless Recording in the Peripheral Nervous System with Ultrasonic Neural Dust
Seo, D., Neely, R. M., Shen, K., Singhal, U., Alon, E., Rabaey, J. M., Carmena, J. M., & Maharbiz, M. M. (2016) · Neuron · doi:10.1016/j.neuron.2016.06.034 · Cited by 557
A jump-start for electroceuticals
Famm, K., Litt, B., Tracey, K. J., Boyden, E. S., & Slaoui, M. (2013) · Nature · doi:10.1038/496159a · Cited by 554
Wireless power transfer to deep-tissue microimplants
Ho, J. S., Yeh, A. J., Neofytou, E., Kim, S., Tanabe, Y., Patlolla, B., Beygui, R. E., & Poon, A. S. Y. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1403002111 · Cited by 541 · cited 5×
“mid-field resonant coupling and the ultrasonic power transfer become very significant and are consequently being well integrated into the implant design flow [37], [39] to form a robust”
BackgroundMethodInfluentialNanomaterials for Neural Interfaces
Kotov, N. A., Winter, J. O., Clements, I. P., Jan, E., Timko, B. P., Campidelli, S., Pathak, S., Mazzatenta, A., Lieber, C. M., Prato, M., et al. (2009) · Advanced Materials · doi:10.1002/adma.200801984 · Cited by 504
Implanted Neural Interfaces: Biochallenges and Engineered Solutions
Grill, W. M., Norman, S. E., & Bellamkonda, R. V. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124927 · Cited by 488
Artificial vision with wirelessly powered subretinal electronic implant alpha-IMS
Stingl, K., Bartz-Schmidt, K. U., Besch, D., Braun, A., Bruckmann, A., Gekeler, F., Greppmaier, U., Hipp, S., Hörtdörfer, G., Kernstock, C., et al. (2013) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2013.0077 · Cited by 473
Ultrasonic neuromodulation by brain stimulation with transcranial ultrasound
Tufail, Y., Yoshihiro, A., Pati, S., Li, M. M., & Tyler, W. J. (2011) · Nature Protocols · doi:10.1038/nprot.2011.371 · Cited by 473
Security and Privacy for Implantable Medical Devices
Halperin, D., Heydt-Benjamin, T. S., Fu, K., Kohno, T., & Maisel, W. H. (2008) · IEEE Pervasive Computing · doi:10.1109/mprv.2008.16 · Cited by 470
Optimal Frequency for Wireless Power Transmission Into Dispersive Tissue
Poon, A. S. Y., O'Driscoll, S., & Meng, T. H. (2010) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2010.2044310 · Cited by 469
Photovoltaic retinal prosthesis with high pixel density
Mathieson, K., Loudin, J., Goetz, G., Huie, P., Wang, L., Kamins, T. I., Galambos, L., Smith, R., Harris, J. S., Sher, A., et al. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.104 · Cited by 467
Vagus nerve stimulation: a new tool for brain research and therapy
George, M. S., Sackeim, H. A., Rush, A. J., Marangell, L. B., Nahas, Z., Husain, M. M., Lisanby, S., Burt, T., Goldman, J., & Ballenger, J. C. (2000) · Biological Psychiatry · doi:10.1016/s0006-3223(99)00308-x · Cited by 461
Antennas and Propagation for Body-Centric Wireless Communications
(2008) · IEEE Antennas and Propagation Magazine · doi:10.1109/map.2008.4562277 · Cited by 458
Design and analysis of an adaptive transcutaneous power telemetry for biomedical implants
Wang, G., Liu, W., Sivaprakasam, M., & Kendir, G. A. (2005) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2005.852923 · Cited by 435
Battery-free, stretchable optoelectronic systems for wireless optical characterization of the skin
Kim, J., Salvatore, G. A., Araki, H., Chiarelli, A. M., Xie, Z., Banks, A., Sheng, X., Liu, Y., Lee, J. W., Jang, K.-I., et al. (2016) · Science Advances · doi:10.1126/sciadv.1600418 · Cited by 403
Zeng, F.-G. (2004) · Trends in Amplification · doi:10.1177/108471380400800102 · Cited by 401
Silk‐Based Conformal, Adhesive, Edible Food Sensors
Tao, H., Brenckle, M. A., Yang, M., Zhang, J., Liu, M., Siebert, S. M., Averitt, R. D., Mannoor, M. S., McAlpine, M. C., Rogers, J. A., et al. (2012) · Advanced Materials · doi:10.1002/adma.201103814 · Cited by 393
On the guided propagation of electromagnetic wave beams
Goubau, G., & Schwering, F. (1961) · IRE Transactions on Antennas and Propagation · doi:10.1109/tap.1961.1144999 · Cited by 393
Wireless Power Transfer in Loosely Coupled Links: Coil Misalignment Model
Fotopoulou, K., & Flynn, B. W. (2011) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2010.2093534 · Cited by 391
An Intracardiac Pacemaker for Stokes-Adams Seizures
Furman, S., & Schwedel, J. B. (1959) · New England Journal of Medicine · doi:10.1056/nejm195911052611904 · Cited by 389
Current Clinical Issues for MRI Scanning of Pacemaker and Defibrillator Patients
KALIN, R., & STANTON, M. S. (2005) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2005.50024.x · Cited by 381
A Minimally Invasive 64-Channel Wireless μECoG Implant
Muller, R., Le, H.-P., Li, W., Ledochowitsch, P., Gambini, S., Bjorninen, T., Koralek, A., Carmena, J. M., Maharbiz, M. M., Alon, E., et al. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2364824 · Cited by 372
Exact analysis of class E tuned power amplifier at any Q and switch duty cycle
Kazimierczuk, M., & Puczko, K. (1987) · IEEE Transactions on Circuits and Systems · doi:10.1109/tcs.1987.1086114 · Cited by 372
da Cruz, L., Coley, B. F., Dorn, J., Merlini, F., Filley, E., Christopher, P., Chen, F. K., Wuyyuru, V., Sahel, J., Stanga, P., et al. (2013) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2012-301525 · Cited by 359
Maximum Achievable Efficiency in Near-Field Coupled Power-Transfer Systems
Zargham, M., & Gulak, P. G. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2174794 · Cited by 349
Xue, R.-F., Cheng, K.-W., & Je, M. (2013) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2012.2209297 · Cited by 340
Microelectrodes, Microelectronics, and Implantable Neural Microsystems
Wise, K. D., Sodagar, A. M., Yao, Y., Gulari, M. N., Perlin, G. E., & Najafi, K. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.922564 · Cited by 335
Design of a high-resolution optoelectronic retinal prosthesis
Palanker, D., Vankov, A., Huie, P., & Baccus, S. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/1/012 · Cited by 334
Bioelectronic medicines: a research roadmap
Birmingham, K., Gradinaru, V., Anikeeva, P., Grill, W. M., Pikov, V., McLaughlin, B., Pasricha, P., Weber, D., Ludwig, K., & Famm, K. (2014) · Nature Reviews Drug Discovery · doi:10.1038/nrd4351 · Cited by 322
Yi, J., Ki, W.-H., & Tsui, C.-Y. (2007) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2006.887974 · Cited by 321
An implantable wireless neural interface for recording cortical circuit dynamics in moving primates
Borton, D. A., Yin, M., Aceros, J., & Nurmikko, A. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/2/026010 · Cited by 321
Peckham, P. H., Keith, M. W., Kilgore, K. L., Grill, J. H., Wuolle, K. S., Thrope, G. B., Gorman, P., Hobby, J., Mulcahey, M. J., Carroll, S., et al. (2001) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.25910 · Cited by 319 · cited 1×
“Cardiac [1], cochlear [2], spinal [3], retinal [4], motor [5], and cortical [6] implants have seen unprecedented growth in the last two decades to have functionality, form factor, and packaging suitable for chronic implantation.”
BackgroundLiu, C., Guo, Y.-X., & Xiao, S. (2014) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2014.2307341 · Cited by 316
Self-citationFully integrated wideband high-current rectifiers for inductively powered devices
Ghovanloo, M., & Najafi, K. (2004) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2004.835822 · Cited by 296
Implantable Cardioverter–Defibrillators
DiMarco, J. P. (2003) · New England Journal of Medicine · doi:10.1056/nejmra035432 · Cited by 290
Diagnostic ultrasound : physics and equipment
Hoskins, P. R., Martin, K., & Thrush, A. J. (2010) · Cited by 273
Huang, F.-J., Lee, C.-M., Chang, C.-L., Chen, L.-K., Yo, T.-C., & Luo, C.-H. (2011) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2011.2152317 · Cited by 268
An Integrated 256-Channel Epiretinal Prosthesis
Chen, K., Yang, Z., Hoang, L., Weiland, J., Humayun, M., & Liu, W. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2055371 · Cited by 266
Radio-Frequency Coils in Implantable Devices: Misalignment Analysis and Design Procedure
Soma, M., Galbraith, D. C., & White, R. L. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.326088 · Cited by 265
Diagnostic Ultrasound: Physics and Equipment
(2010) · Cambridge University Press eBooks · doi:10.1017/cbo9780511750885 · Cited by 261
Pattern recognition with the optic nerve visual prosthesis
Veraart, C., Wanet‐Defalque, M., Gérard, B., Vanlierde, A., & Delbeke, J. (2003) · Artificial Organs · doi:10.1046/j.1525-1594.2003.07305.x · Cited by 259
MED-EL Cochlear Implants: State of the Art and a Glimpse Into the Future
Hochmair, I., Nopp, P., Jolly, C., Schmidt, M., Schößer, H., Garnham, C., & Anderson, I. (2006) · Trends in Amplification · doi:10.1177/1084713806296720 · Cited by 254
Guo, S., & Lee, H. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2020195 · Cited by 253
Optimal Design of Wireless Power Transmission Links for Millimeter-Sized Biomedical Implants
Ahn, D., & Ghovanloo, M. (2016) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2370794 · Cited by 246
Integrated Low-Loss CMOS Active Rectifier for Wirelessly Powered Devices
Lam, Y.-H., Ki, W.-H., & Tsui, C.-Y. (2006) · IEEE Transactions on Circuits and Systems II: Express Briefs · doi:10.1109/tcsii.2006.885400 · Cited by 246
V. Experimental researches in electricity
Faraday, M. (1832) · Philosophical Transactions of the Royal Society of London · doi:10.1098/rstl.1832.0006 · Cited by 246
Charthad, J., Weber, M. J., Chang, T. C., & Arbabian, A. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2015.2427336 · Cited by 245 · cited 1×
“A mm-sized IMD with UTET and hybrid bidirectional RF data communication link is presented in [92].”
MethodBION ™ system for distributed neural prosthetic interfaces
Loeb, G. E., Peck, R. A., Moore, W. H., & Hood, K. (2001) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00011-x · Cited by 243
A wirelessly powered and controlled device for optical neural control of freely-behaving animals
Wentz, C. T., Bernstein, J. G., Monahan, P., Guerra, A., Rodriguez, A., & Boyden, E. S. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/046021 · Cited by 242
Modeling and optimization of printed spiral coils in air, saline, and muscle tissue environments
Jow, U.-M., & Ghovanloo, M. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2009.2025366 · Cited by 241 · cited 1×
“Near-field inductive coupling [28]–[30], near-field capacitive coupling [31]–[33], ultrasonics [34]–[37], and mid-field [38], [39] and far-field EM coupling [40], [41] are the various methods proposed to power implantable devices.”
MethodVagus Nerve Stimulation Relieves Chronic Refractory Migraine and Cluster Headaches
Mauskop, A. (2005) · Cephalalgia · doi:10.1111/j.1468-2982.2005.00611.x · Cited by 241
Ultrasonic transcutaneous energy transfer for powering implanted devices
Ozeri, S., & Shmilovitz, D. (2010) · Ultrasonics · doi:10.1016/j.ultras.2009.11.004 · Cited by 240
Design and Safety Considerations of an Implantable Rectenna for Far-Field Wireless Power Transfer
Liu, C., Guo, Y.-X., Sun, H., & Xiao, S. (2014) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2014.2352363 · Cited by 234
Self-citationSjogren, M. J. C., Hellstrom, P. T. O., Jonsson, M. A. G., Runnerstam, M., C-son Silander, H., Ben-Menachem, E., Sjögren, J. C., & Hellström, P. T. O. (2002) · The Journal of Clinical Psychiatry · doi:10.4088/jcp.v63n1103 · Cited by 233
Experimental study of large rectenna array for microwave energy transmission
Shinohara, N., & Matsumoto, H. (1998) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/22.661713 · Cited by 228
Midfield Wireless Powering for Implantable Systems
Ho, J. S., Kim, S., & Poon, A. S. Y. (2013) · Proceedings of the IEEE · doi:10.1109/jproc.2013.2251851 · Cited by 227
An optimal design methodology for inductive power link with class-E amplifier
Kendir, G. A., Liu, W., Wang, G., Sivaprakasam, M., Bashirullah, R., Humayun, M. S., & Weiland, J. D. (2005) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2005.846208 · Cited by 222
Fully Wireless Implantable Cardiovascular Pressure Monitor Integrated with a Medical Stent
Chow, E. Y., Chlebowski, A. L., Chakraborty, S., Chappell, W. J., & Irazoqui, P. P. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2041058 · Cited by 222
Lee, S. B., Lee, H.-M., Kiani, M., Jow, U.-M., & Ghovanloo, M. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2078814 · Cited by 220
An Implantable 64-Channel Wireless Microsystem for Single-Unit Neural Recording
Sodagar, A. M., Perlin, G. E., Yao, Y., Najafi, K., & Wise, K. D. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2023159 · Cited by 218
Wireless Neural Recording With Single Low-Power Integrated Circuit
Harrison, R. R., Kier, R. J., Chestek, C. A., Gilja, V., Nuyujukian, P., Ryu, S., Greger, B., Solzbacher, F., & Shenoy, K. V. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2023298 · Cited by 209
A RF to DC Voltage Conversion Model for Multi-Stage Rectifiers in UHF RFID Transponders
Barnett, R. E., Liu, J., & Lazar, S. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2008.2010991 · Cited by 207
Fabrication and application of flexible, multimodal light-emitting devices for wireless optogenetics
McCall, J. G., Kim, T.-I., Shin, G., Huang, X., Jung, Y. H., Al-Hasani, R., Omenetto, F. G., Bruchas, M. R., & Rogers, J. A. (2013) · Nature Protocols · doi:10.1038/nprot.2013.158 · Cited by 203
Inductor Modeling in Wireless Links for Implantable Electronics
Yang, Z., Liu, W., & Basham, E. (2007) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2007.904189 · Cited by 199
RF powering of millimeter- and submillimeter-sized neural prosthetic implants
Heetderks, W. J. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.1388 · Cited by 197
The Development of the Nucleus® Freedom™ Cochlear Implant System
Patrick, J. F., Busby, P. A., & Gibson, P. J. (2006) · Trends in Amplification · doi:10.1177/1084713806296386 · Cited by 196
Demonstration of artificial visual percepts generated through thalamic microstimulation
Pezaris, J. S., & Reid, R. C. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0608563104 · Cited by 195
Medical Device Regulation: An Introduction for the Practicing Physician
Maisel, W. H. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-4-200402170-00012 · Cited by 194
Fighting Blindness with Microelectronics
Zrenner, E. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3007399 · Cited by 190
The functional performance of the Argus II retinal prosthesis
Stronks, H. C., & Dagnelie, G. (2014) · Expert Review of Medical Devices · doi:10.1586/17434440.2014.862494 · Cited by 189
The sensitivity of biological tissue to ultrasound
Barnett, S. B., Rott, H.-D., ter Haar, G. R., Ziskin, M. C., & Maeda, K. (1997) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(97)00027-6 · Cited by 187
Low-Power Wireless Power Delivery
Falkenstein, E., Roberg, M., & Popovic, Z. (2012) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2012.2193594 · Cited by 186
Wireless Power Delivery to Flexible Subcutaneous Implants Using Capacitive Coupling
Jegadeesan, R., Agarwal, K., Guo, Y.-X., Yen, S.-C., & Thakor, N. V. (2017) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2016.2615623 · Cited by 184
Self-citationWeiland, J. D., & Humayun, M. S. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.922589 · Cited by 179
An RFID-Based Closed-Loop Wireless Power Transmission System for Biomedical Applications
Kiani, M., & Ghovanloo, M. (2010) · IEEE Transactions on Circuits and Systems II: Express Briefs · doi:10.1109/tcsii.2010.2043470 · Cited by 173
The history of wireless power transmission
Brown, W. C. (1996) · Solar Energy · doi:10.1016/0038-092x(95)00080-b · Cited by 167
Capacitive coupling for power and data telemetry to implantable biomedical microsystems
Sodagar, A. M., & Amiri, P. (2009) · 2009 4th International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2009.5109320 · Cited by 163
Stimulation with a Wireless Intraocular Epiretinal Implant Elicits Visual Percepts in Blind Humans
Klauke, S., Goertz, M., Rein, S., Hoehl, D., Thomas, U., Eckhorn, R., Bremmer, F., & Wachtler, T. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.09-4410 · Cited by 161
Roessler, G., Laube, T., Brockmann, C., Kirschkamp, T., Mazinani, B., Goertz, M., Koch, C., Krisch, I., Sellhaus, B., Trieu, H. K., et al. (2009) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.08-2752 · Cited by 161
Development and Implantation of a Minimally Invasive Wireless Subretinal Neurostimulator
Shire, D. B., Kelly, S. K., Chen, J., Doyle, P., Gingerich, M. D., Cogan, S. F., Drohan, W. A., Mendoza, O., Theogarajan, L. S., Wyatt, J. L., et al. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2021401 · Cited by 156
A mm-sized implantable power receiver with adaptive link compensation
O'Driscoll, S., Poon, A. S. Y., & Meng, T. (2009) · IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2009.4977424 · Cited by 155
A Wireless Implantable Multichannel Microstimulating System-on-a-Chip With Modular Architecture
Ghovanloo, M., & Najafi, K. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903970 · Cited by 151
Photovoltaic retinal prosthesis: implant fabrication and performance
Wang, L., Mathieson, K., Kamins, T. I., Loudin, J., Galambos, L., Goetz, G., Sher, A., Mandel, Y., Huie, P., Lavinsky, D., et al. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/4/046014 · Cited by 146
An Ultrasonically Powered Implantable Micro-Oxygen Generator (IMOG)
Maleki, T., Cao, N., Song, S., Kao, C. H., Ko, S., & Ziaie, B. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2163634 · Cited by 144
Warty, R., Tofighi, M.-R., Kawoos, U., & Rosen, A. (2008) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2008.2004254 · Cited by 142
Wireless Power Transfer to Miniature Implants: Transmitter Optimization
Kim, S., Ho, J. S., & Poon, A. S. Y. (2012) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2012.2207341 · Cited by 139
Lee, S. B., Lee, H., Kiani, M., Jow, U.-M., & Ghovanloo, M. (2010) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2010.5434028 · Cited by 123
Update on Retinal Prosthetic Research: The Boston Retinal Implant Project
Rizzo, J. F. (2011) · Journal of Neuro-Ophthalmology · doi:10.1097/wno.0b013e31821eb79e · Cited by 122
A Low-Frequency Versatile Wireless Power Transfer Technology for Biomedical Implants
Jiang, H., Zhang, J., Lan, D., Chao, K. K., Liou, S. P., Shahnasser, H., Fechter, R., Hirose, S., Harrison, M. R., & Roy, S. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2220763 · Cited by 121
Hauser, R. G. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.02.077 · Cited by 121
A Hermetic Wireless Subretinal Neurostimulator for Vision Prostheses
Kelly, S. K., Shire, D. B., Chen, J., Doyle, P., Gingerich, M. D., Cogan, S. F., Drohan, W. A., Behan, S., Theogarajan, L. S., Wyatt, J. L., et al. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2165713 · Cited by 121
Injectable microstimulator for functional electrical stimulation
Loeb, G. E., Zamin, C. J., Schulman, J. H., & Troyk, P. R. (1991) · Medical & Biological Engineering & Computing · doi:10.1007/bf02446097 · Cited by 118
Zargham, M., & Gulak, P. G. (2015) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2328318 · Cited by 115
Topology Selection and Efficiency Improvement of Inductive Power Links
Jegadeesan, R., & Guo, Y. (2012) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2012.2207325 · Cited by 115
Self-citationElectromagnetic interference in patients with implanted pacemakers or cardioverter-defibrillators
NIEHAUS, M., & Tebbenjohanns, J. (2001) · Heart · doi:10.1136/heart.86.3.246 · Cited by 115
Ibrahim, A., & Kiani, M. (2016) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2016.2515541 · Cited by 114
Far-Field RF Powering of Implantable Devices: Safety Considerations
Bercich, R. A., Duffy, D. R., & Irazoqui, P. P. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2246787 · Cited by 107
Artificial pacemaker for treatment of Adams-Stokes syndrome and slow heart rate
Elmgvist, R., Landegren, J., Pettersson, S. O., Senning, A., & William‐Olsson, G. (1963) · American Heart Journal · doi:10.1016/0002-8703(63)90239-4 · Cited by 105
Enabling Wireless Powering and Telemetry for Peripheral Nerve Implants
Jegadeesan, R., Nag, S., Agarwal, K., Thakor, N. V., & Guo, Y. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2015.2424985 · Cited by 101
Self-citationKiani, M., & Ghovanloo, M. (2014) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2304956 · Cited by 100
Ultrasonic transcutaneous energy transfer using a continuous wave 650kHz Gaussian shaded transmitter
Ozeri, S., Shmilovitz, D., Singer, S., & Wang, C. (2010) · Ultrasonics · doi:10.1016/j.ultras.2010.01.004 · Cited by 99
Materials and Designs for Wirelessly Powered Implantable Light‐Emitting Systems
Kim, R.-H., Tao, H., Kim, T., Zhang, Y., Kim, S. E., Panilaitis, B., Yang, M., Kim, D., Jung, Y. H., Kim, B. H., et al. (2012) · Small · doi:10.1002/smll.201200943 · Cited by 99
A Wireless Implantable Microsystem for Multichannel Neural Recording
Sodagar, A. M., Wise, K. D., & Najafi, K. (2009) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2009.2029957 · Cited by 98
Cortical Activation Via an Implanted Wireless Retinal Prosthesis
Walter, P., ́rday, Z. ́. F. K., Görtz, M., Alteheld, N., Rößler, G., Stieglitz, T., & Eysel, U. T. (2005) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.04-0924 · Cited by 93
Electromagnetic Fields: Human Safety Issues
Gandhi, O. P. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.020702.153447 · Cited by 93
Historical notes on the cavity magnetron
Boot, H. A. H., & Randall, J. T. (1976) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1976.18476 · Cited by 92
A Power and Data Link for a Wireless-Implanted Neural Recording System
Rush, A. D., & Troyk, P. R. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2214385 · Cited by 90
An Inductively Coupled RF System for the Transmission of 1 kW of Power Through the Skin
Schuder, J. C., Gold, J. H., & Stephenson, H. E. (1971) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1971.4502849 · Cited by 88
Miniaturized Dual-Band Antenna for Implantable Wireless Communications
Xu, L.-J., Guo, Y.-X., & Wu, W. (2014) · IEEE Antennas and Wireless Propagation Letters · doi:10.1109/lawp.2014.2329937 · Cited by 87
Self-citationOptimal Operating Frequency in Wireless Power Transmission for Implantable Devices
Poon, A. S. Y., O’Driscoll, S., & Meng, T. H. Y. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353634 · Cited by 86
On the Design of Microfluidic Implant Coil for Flexible Telemetry System
Qusba, A., Ramrakhyani, A. K., So, J.-H., Hayes, G., Dickey, M., & Lazzi, G. (2014) · IEEE Sensors Journal · doi:10.1109/jsen.2013.2293096 · Cited by 83
Development of Nonsuperstrate Implantable Low-Profile CPW-Fed Ceramic Antennas
Chien, T.-F., Cheng, C.-M., Yang, H.-C., Jiang, J.-W., & Luo, C.-H. (2010) · IEEE Antennas and Wireless Propagation Letters · doi:10.1109/lawp.2010.2053342 · Cited by 80
Diagnostic Ultrasound: List of Contributors
Hoskins, P. R., Martin, K., & Thrush, A. J. (2010) · Cited by 78
A Low-Power Fully Implantable 15-Channel Retinal Stimulator Chip
Theogarajan, L. S. (2008) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2008.2004331 · Cited by 78
Inductive and Ultrasonic Multi-Tier Interface for Low-Power, Deeply Implantable Medical Devices
Sanni, A., Vilches, A., & Toumazou, C. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2175390 · Cited by 75
Inductive Power Transfer System With Self-Calibrated Primary Resonant Frequency
Trigui, A., Hached, S., Mounaim, F., Ammari, A., & Sawan, M. (2015) · IEEE transactions on power electronics · doi:10.1109/tpel.2015.2399417 · Cited by 74
A Hybrid Patch/Slot Implantable Antenna for Biotelemetry Devices
Liu, C.-R., Guo, Y.-X., & Xiao, S. (2012) · IEEE Antennas and Wireless Propagation Letters · doi:10.1109/lawp.2013.2237879 · Cited by 74
Self-citationBION microstimulators: A case study in the engineering of an electronic implantable medical device
Kane, M. J., Breen, P. P., Quondamatteo, F., & OLaighin, G. M. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.08.010 · Cited by 73
Experimental researches in electricity
Faraday, M. (1851) · Abstracts of the Papers Communicated to the Royal Society of London · doi:10.1098/rspl.1843.0063 · Cited by 71
A biosafety comparison between capacitive and inductive coupling in biomedical implants
Al-Kalbani, A. I., Yuce, M. R., & Redoute, J.-M. (2014) · IEEE Antennas and Wireless Propagation Letters · doi:10.1109/lawp.2014.2328375 · Cited by 69
Degenford, J. E., Sirkis, M. D., & Steier, W. H. (1964) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.1964.1125845 · Cited by 68
On-Chip Implantable Antennas for Wireless Power and Data Transfer in a Glaucoma-Monitoring SoC
Marnat, L., Ouda, M. H., Arsalan, M., Salama, K., & Shamim, A. (2012) · IEEE Antennas and Wireless Propagation Letters · doi:10.1109/lawp.2013.2240253 · Cited by 66
Ozeri, S., & Shmilovitz, D. (2014) · Ultrasonics · doi:10.1016/j.ultras.2014.04.019 · Cited by 65
Power and Interactive Information Transmission to Implanted Medical Device Using Ultrasonic
Suzuki, S., Kimura, S., Katane, T., Saotome, H., Saito, O., & Kobayashi, K. (2002) · Japanese Journal of Applied Physics · doi:10.1143/jjap.41.3600 · Cited by 60
Neural Interface Devices: Spinal Cord Stimulation Technology
North, R. B. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.922558 · Cited by 59 · cited 1×
“Cardiac [1], cochlear [2], spinal [3], retinal [4], motor [5], and cortical [6] implants have seen unprecedented growth in the last two decades to have functionality, form factor, and packaging suitable for chronic implantation.”
BackgroundDevelopment of a micromachined epiretinal vision prosthesis
Stieglitz, T. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/6/065005 · Cited by 54
The Feasible FES System: Battery Powered BION Stimulator
Schulman, J. H. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.922588 · Cited by 52
Wirelessly powering miniature implants for optogenetic stimulation
Yeh, A. J., Ho, J. S., Tanabe, Y., Neofytou, E. A., Beygui, R. E., & Poon, A. S. Y. (2013) · Applied Physics Letters · doi:10.1063/1.4825272 · Cited by 51
(1998) · Institute of Physics eBooks · doi:10.1887/0750305932 · Cited by 47
Realization of a 15-channel, hermetically-encased wireless subretinal prosthesis for the blind
Kelly, S. K., Shire, D. B., Chen, J., Doyle, P., Gingerich, M. D., Drohan, W. A., Theogarajan, L. S., Cogan, S. F., Wyatt, J. L., & Rizzo, J. F. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333619 · Cited by 45
Longevity of Dual Chamber Pacemakers: Device and Patient Related Determinants
Kindermann, M., Schwaab, B., Berg, M., & Fröhlig, G. (2001) · Pacing and clinical electrophysiology : PACE · doi:10.1046/j.1460-9592.2001.00810.x · Cited by 44
Howard, M. A., Utz, M., Brennan, T. J., Dalm, B., Viljoen, S., Jeffery, N. D., & Gillies, G. T. (2011) · Journal of Applied Physics · doi:10.1063/1.3626469 · Cited by 44
Meng, M., & Kiani, M. (2016) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2016.2626151 · Cited by 44
Planar immersion lens with metasurfaces
Ho, J. S., Qiu, B., Tanabe, Y., Yeh, A. J., Fan, S., & Poon, A. S. Y. (2015) · Physical Review B · doi:10.1103/physrevb.91.125145 · Cited by 40
Second‐Generation Microstimulator
Arcos, I., Davis, R., Fey, K., Mishler, D., Sanderson, D., Tanacs, C., Vogel, M., Wolf, R., Zilberman, Y., & Schulman, J. H. (2002) · Artificial Organs · doi:10.1046/j.1525-1594.2002.06938.x · Cited by 39
Zrenner, E. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.114 · Cited by 36
Sharma, A., Rieth, L., Tathireddy, P., Harrison, R., Oppermann, H., Klein, M., Töpper, M., Jung, E., Normann, R., Clark, G., et al. (2012) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2011.11.015 · Cited by 35
Interaction of electromagnetic waves with humans in wearable and biomedical implant antennas
Agarwal, K., & Guo, Y.-X. (2015) · Asia-Pacific Software Engineering Conference · doi:10.1109/apemc.2015.7175377 · Cited by 35
Self-citationModeling of a capacitive link for data telemetry to biomedical implants
Takhti, M., Asgarian, F., & Sodagar, A. M. (2011) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2011.6107757 · Cited by 34
Highly efficient wireless energy harvesting system using metamaterial based compact CP antenna
Agarwal, K., Mishra, T., Karim, M., Nasimuddin, Chuen, M., Guo, Y.-X., & Panda, S. K. (2013) · 2013 IEEE MTT-S International Microwave Symposium Digest (MTT) · doi:10.1109/mwsym.2013.6697693 · Cited by 33
Self-citationShmilovitz, D., Ozeri, S., Wang, C., & Spivak, B. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2280460 · Cited by 31
A 1mm 3 2Mbps 330fJ/b transponder for implanted neural sensors
Michael, M., Chen, Y., Sutardja, C., Tang, C., Gowda, S., Wagner, M., Werthimer, D. J., & Rabaey, J. M. (2011) · Symposium on VLSI Circuits · Cited by 27
Compensating for Tissue Changes in an Ultrasonic Power Link for Implanted Medical Devices
Vihvelin, H., Leadbetter, J., Bance, M., Brown, J. A., & Adamson, R. B. A. (2015) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2015.2421823 · Cited by 26
Optimal Tuning of Inductive Wireless Power Links: Limits of Performance
Halpern, M. E., & Ng, D. C. (2015) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2014.2386771 · Cited by 21
Security for Wireless Implantable Medical Devices
Hei, X., & Du, X. (2013) · SpringerBriefs in computer science · doi:10.1007/978-1-4614-7153-0 · Cited by 20
Erfani, R., & Sodagar, A. M. (2013) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2013.6679696 · Cited by 18
Spatial carrier position modulation based multichannel capacitive link for bioelectronic implants
Hassan, A., Sawma, C., Hasanuzzaman, M., Gosselin, B., & Sawan, M. (2015) · Biomedical Circuits and Systems Conference · doi:10.1109/biocas.2015.7348292 · Cited by 17
Apparatus for Efficient Power Transfer Through a Tissue Barrier
(1968) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1968.4502534 · Cited by 16
Leadbetter, J., Brown, J., & Adamson, R. B. (2013) · The Journal of the Acoustical Society of America · doi:10.1121/1.4805305 · Cited by 13
Vision implants: An electrical device will bring light to the blind
Niu, J., Liu, Y., Ren, Q., Zhou, Y., Zhou, Y., & Niu, S. (2007) · Science in China Series F Information Sciences · doi:10.1007/s11432-007-0072-z · Cited by 13
Wireless Powering for Miniature Implantable Systems
Ho, J. S., Yeh, A. J., Kim, S., & Poon, A. S. Y. (2014) · Springer eBooks · doi:10.1007/978-1-4614-8151-5_13 · Cited by 6
Cited by
Multifunctional materials for implantable and wearable photonic healthcare devices
Lee, G.-H., Moon, H., Kim, H., Lee, G. H., Kwon, W., Yoo, S., Myung, D., Yun, S. H., Bao, Z., & Hahn, S. K. (2020) · Nature Reviews Materials · doi:10.1038/s41578-019-0167-3 · Cited by 667
A Survey on Wearable Technology: History, State-of-the-Art and Current Challenges
Ometov, A., Shubina, V., Klus, L., Skibińska, J., Saafi, S., Pascacio, P., Flueratoru, L., Gaibor, D. Q., Chukhno, N., Chukhno, O., et al. (2021) · Computer Networks · doi:10.1016/j.comnet.2021.108074 · Cited by 506
Skin-inspired soft bioelectronic materials, devices and systems
Zhao, C., Park, J., Root, S. E., & Bao, Z. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00194-1 · Cited by 408
Wireless power transfer techniques for implantable medical devices: a review
Khan, S. R., Pavuluri, S. K., Cummins, G., & Desmulliez, M. P. Y. (2020) · Sensors · doi:10.3390/s20123487 · Cited by 355
“In [35], different WPT techniques and their design issues are reviewed.”
BackgroundInfluentialLarge-Area Soft e-Skin: The Challenges Beyond Sensor Designs
Dahiya, R., Yogeswaran, N., Liu, F., Manjakkal, L., Burdet, E., Hayward, V., & Jörntell, H. (2019) · Proceedings of the IEEE · doi:10.1109/jproc.2019.2941366 · Cited by 309
Metadata
- Authors
- Agarwal, K., Jegadeesan, R., Guo, Y.-X., & Thakor, N. V.
- Venue
- IEEE Reviews in Biomedical Engineering
- Published
- 2017
- Volume
- 10
- Pages
- 136-161
- ISSN
- 1937-3333 (ISSN-L)
- 1941-1189
- OpenAlex
- W2596697137
- Cited by
- 540
- References
- 181
- FWCI
- 18.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.