High-Speed OQPSK and Efficient Power Transfer Through Inductive Link for Biomedical Implants
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Biomedical implants require wireless power and bidirectional data transfer. We pursue our previous work on a novel topology for a multiple carrier inductive link by presenting the fabricated coils. We show that the coplanar geometry approach is better suited for displacement tolerance. We provide a theoretical analysis of the efficiency of power transfer and phase-shift-keying communications through an inductive link. An efficiency of up to 61% has been achieved experimentally for power transfer and a data rate of 4.16 Mb/s with a bit-error rate of less than 2 × 10(-6) has been obtained with our fabricated offset quadrature phase-shift keying modules due to the inductive link optimization presented in this paper.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Geometric approach for coupling enhancement of magnetically coupled coils
Zierhofer, C. M., & Hochmair, E. S. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.503178 · Cited by 420 · cited 1×
“The efficiency will increase monotonically with the coupling coefficient [10].”
BackgroundDesigning Efficient Inductive Power Links for Implantable Devices
Harrison, R. R. (2007) · 2007 IEEE International Symposium on Circuits and Systems (ISCAS) · doi:10.1109/iscas.2007.378508 · Cited by 244 · cited 1×
“By definition, efficiency is the ratio of power consumed by the load to the power delivered by the source [8]”
BackgroundGhovanloo, M., & Atluri, S. (2007) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2007.905187 · Cited by 202 · cited 5×
“Back telemetry, however, attracted much less attention from researchers so far, until they introduced the possibility of using RF for this purpose [1], making their system a hybrid RF and dual-band inductive link.”
BackgroundMethodInfluentialWireless smart implants dedicated to multichannel monitoring and microstimulation
Sawan, M., Hu, Y., & Coulombe, J. (2005) · IEEE Circuits and Systems Magazine · doi:10.1109/mcas.2005.1405898 · Cited by 201 · cited 1×
“Polystim Neurotechnologies Laboratory’s work has produced a high-speed bidirectional transceiver using the offset quadrature phase-shift keying (OQPSK) modulation scheme that can be used for bidirectional transmission of information [4], [5].”
MethodSelf-citationAtluri, S., & Ghovanloo, M. (2006) · 2006 IEEE International Symposium on Circuits and Systems · doi:10.1109/iscas.2006.1692789 · Cited by 196
Improved Wireless, Transcutaneous Power Transmission for In Vivo Applications
O'Handley, R. C., Huang, J. K., Bono, D. C., & Simon, J. (2008) · IEEE Sensors Journal · doi:10.1109/jsen.2007.912899 · Cited by 62 · cited 1×
“This leaves us with a limited number of options, among which capacitive, magnetic, electromagnetic, optical, and magnetoelectric power transfer [7].”
BackgroundImplantable biomimetic microelectronic systems design
Liu, W., Sivaprakasam, M., Wang, G., Zhou, M., Granacki, J. J., LaCoss, J., & Wills, J. D. (2005) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2005.1511502 · Cited by 61 · cited 2×
“Others are proposing dual-band inductive links [2], [3], keeping load-shift keying (LSK) as a possible feedback path.”
BackgroundA Dual Band Wireless Power and FSK Data Telemetry for Biomedical Implants
Jung, L. H., Byrnes-Preston, P., Hessler, R., Lehmann, T., Suaning, G. J., & Lovell, N. H. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353871 · Cited by 56 · cited 2×
“Others are proposing dual-band inductive links [2], [3], keeping load-shift keying (LSK) as a possible feedback path.”
BackgroundImprovement of power efficiency of inductive links for implantable devices
Silay, K. M., Dehollain, C., & Declercq, M. J. (2008) · Conference on Ph.D. Research in Microelectronics and Electronics · doi:10.1109/rme.2008.4595767 · Cited by 45 · cited 1×
“Silay presents a methodology to improve the efficiency of an inductive link with this process [11].”
MethodDesign and Optimization of Printed Spiral Coils for Efficient Inductive Power Transmission
Jow, U.-M., & Ghovanloo, M. (2007) · IEEE International Conference on Electronics, Circuits and Systems (ICECS) · doi:10.1109/icecs.2007.4510933 · Cited by 44 · cited 1×
“We made use of coplanar square coils as they are well documented and easier to fabricate on a number of substrates [12].”
MethodAn 8 Mbps data rate transmission by inductive link dedicated to implantable devices
Lü, Z., & Sawan, M. (2008) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2008.4542103 · Cited by 34 · cited 2×
“Our data-transmission system presented in [5] is based on an OQPSK modulation which requires that a sine-wave carrier at 13.”
MethodSelf-citationSalim, A., Baldi, A., & Ziaie, B. (2004) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2003.1280867 · Cited by 13 · cited 1×
“2) Measurement of the Coupling Coefficient: The coupling coefficients have been measured with a simple method from [ 14 ].”
Method
Cited by
Maximum Achievable Efficiency in Near-Field Coupled Power-Transfer Systems
Zargham, M., & Gulak, P. G. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2174794 · Cited by 349
Review of Near-Field Wireless Power and Communication for Biomedical Applications
Kim, H.-J., Hirayama, H., Kim, S., Han, K. J., Zhang, R., & Choi, J.-W. (2017) · IEEE Access · doi:10.1109/access.2017.2757267 · Cited by 252
“Multi-carrier based SWIPT schemes: (a) multiple inductive coupling (power-downlink, uplink) [208], [209], (b) inductive coupling (power, uplink), high frequency (downlink) [112], [210], (c) inductive coupling (power), high frequency (uplink, downlink) [211], [212], (d) three carrier signal: inductive coupling – low fr…”
BackgroundMethodLewis, P. M., Ackland, H. M., Lowery, A. J., & Rosenfeld, J. V. (2015) · Brain Research · doi:10.1016/j.brainres.2014.11.020 · Cited by 228
Wireless power transfer approaches for medical implants: a review
Haerinia, M., & Shadid, R. (2020) · Signals · doi:10.3390/signals1020012 · Cited by 174
“Typically, FSK [24], PSK [25], ASK [26], OOK [27], LSK [28], PPSK [29],”
BackgroundPractical Inductive Link Design for Biomedical Wireless Power Transfer: A Tutorial
Schormans, M., Valente, V., & Demosthenous, A. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2846020 · Cited by 170
Metadata
- Authors
- Simard, G., Sawan, M., & Massicotte, D.
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2010-06
- Volume
- 4
- Issue
- 3
- Pages
- 192-200
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- OpenAlex
- W2126009752
- Cited by
- 193
- References
- 12
- FWCI
- 9.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.