A Power-Efficient Neural Tissue Stimulator With Energy Recovery
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
This paper presents a power-efficient neural stimulator integrated circuit, designed to take advantage of our understanding of iridium-oxide electrode impedance. It efficiently creates a programmable set of voltage supplies directly from a secondary power telemetry coil, then switches the target electrode sequentially through the voltage steps. This sequence of voltages mimics the voltage of the electrode under the constant current drive, resulting in approximately constant current without the voltage drop of the more commonly used linear current source. This method sacrifices some precision, but drastically reduces the series losses seen in traditional current sources and attains power savings of 53%-66% compared to these designs. The proof-of-concept circuit consumes 125 μW per electrode and was fabricated in a 1.5-μm CMOS process, in a die area of 4.76 mm(2).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Charge density and charge per phase as cofactors in neural injury induced by electrical stimulation
McCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.102812 · Cited by 708 · cited 1×
“Our solution needs to use very little standby power and no additional inductors, due to space constraints.”
BackgroundRizzo, J. F., Wyatt, J., Loewenstein, J., Kelly, S., & Shire, D. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0817 · Cited by 478 · cited 1×
“Section VII gives results for an experimental chip, and Section VIII lists the conclusions.”
BackgroundSelf-citationSit, J.-J., & Sarpeshkar, R. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.911631 · Cited by 155 · cited 1×
“This architecture implementation is similar in some ways to the adiabatic circuits used to reduce power in digital design [12], [13].”
Method
Cited by
Lee, H.-M., Kwon, K. Y., Li, W., & Ghovanloo, M. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2355814 · Cited by 161
Arfin, S. K., & Sarpeshkar, R. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2166072 · Cited by 133
“The currents produced by adiabatic switched-capacitor-based stimulators tend to be exponential in nature rather than constant [24]; as the electrode is connected sequentially from one pre-charged capacitor to the next, step changes in electrode voltage lead to an exponential decay in current due to…”
BackgroundA Fully Intraocular High-Density Self-Calibrating Epiretinal Prosthesis
Monge, M., Raj, M., Nazari, M. H., Chang, H.-C., Zhao, Y., Weiland, J. D., Humayun, M. S., Tai, Y.-C., & Emami, A. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2298334 · Cited by 85
“The voltage-based stimulation technique reported in [35] promises high energy-efficiency, but it is more suitable for relatively long stimulation pulses (more than 8 ms).”
BackgroundJeon, H., Bang, J.-S., Jung, Y., Choi, I., & Je, M. (2019) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2019.2930903 · Cited by 62
Hsu, W.-Y., & Schmid, A. (2017) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2017.2694144 · Cited by 49
Metadata
- Authors
- Kelly, S. K., & Wyatt, J. L.
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2011-02
- Volume
- 5
- Issue
- 1
- Pages
- 20-29
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- OpenAlex
- W2136706929
- Cited by
- 107
- References
- 3
- FWCI
- 6.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Power-Efficient Neural Tissue Stimulator With Energy Recovery. https://app.cochat.ai/papers/10.1109/tbcas.2010.2076384
- The paper
- Kelly, S. K., & Wyatt, J. L. (2011). A Power-Efficient Neural Tissue Stimulator With Energy Recovery. IEEE Transactions on Biomedical Circuits and Systems. https://doi.org/10.1109/tbcas.2010.2076384
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.