Implantable Stimulator for Epileptic Seizure Suppression With Loading Impedance Adaptability
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The implantable stimulator for epileptic seizure suppression with loading impedance adaptability was proposed in this work. The stimulator consisted of the high voltage generator, output driver, adaptor, and switches, can constantly provide the required 40-μA stimulus currents, as the loading impedance varied within 10 kΩ -300 kΩ. The performances of this design have been successfully verified in silicon chip fabricated by a 0.35- μm 3.3-V/24-V CMOS process. The power consumption of this work was only 1.1 mW-1.4 mW. The animal test results with the fabricated chip of proposed design have successfully verified in the Long-Evans rats with epileptic seizures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vagus Nerve Stimulation for Epilepsy and Depression
Milby, A. H., Halpern, C. H., & Baltuch, G. H. (2008) · Neurotherapeutics · doi:10.1016/j.nurt.2007.10.071 · Cited by 141 · cited 1×
“In recent years, the new techniques of electrical stimulation, such as the vagus nerve stimulation and deep brain stimulation [15]–[17], have been demonstrated to suppress the abnormal discharge signal before epileptic seizure happen.”
Background
Cited by
Bin Altaf, M. A., Zhang, C., & Yoo, J. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2015.2482498 · Cited by 192
Hsu, W.-Y., & Schmid, A. (2017) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2017.2694144 · Cited by 49
Advances in Neural Recording and Stimulation Integrated Circuits
Li, J., Liu, X., Mao, W., Chen, T., & Yu, H. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.663204 · Cited by 21
“In neural recording, the artifact-induced problem of stimulation sometimes emerges and affects the function of biomedical devices for brain stimulation and recording (Asfour et al., 2007; Chen et al., 2011; Lin et al., 2013; Caldwell et al., 2019).”
BackgroundZhou, Y., Wang, K., Yin, S., Li, W.-Y., Meng, F., Wang, Z.-G., & Ma, K. (2024) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2024.3376370 · Cited by 12
“A current of 40 µ A is enough in the animal test with Long-Evans rats [38] and [40] to suppress epileptic seizures.”
MethodOverview of On-Chip Stimulator Designs for Biomedical Applications
Lin, C.-Y., & Ker, M.-D. (2012) · Journal of Neuroscience and Neuroengineering · doi:10.1166/jnsne.2012.1023 · Cited by 9
“[28] and [29], the output driver consists of a current source, bias circuit, and current mirror to constantly deliver the stimulus current.”
BackgroundMethodSelf-citation
Metadata
- Authors
- Lin, C.-Y., Chen, W.-L., & Ker, M.-D.
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2013-04
- Volume
- 7
- Issue
- 2
- Pages
- 196-203
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- OpenAlex
- W1965295889
- Cited by
- 44
- References
- 1
- FWCI
- 1.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.