Overview of On-Chip Stimulator Designs for Biomedical Applications
Abstract
In recent years, the electrical stimulations have been used for biomedical applications, such as cardiac pacemaker, cochlear implant, muscle exercising, vision restoration, and seizure suppression. Comparing with the traditional treatments by using medicine or surgery, the electrical stimulation was more harmless, flexible, recoverable, and less-destructive. Moreover, with the potential for mass production, CMOS integrated circuits have been designed to implement the electrical stimulators. A comprehensive overview in the field of integrated circuit design for implantable stimulator was presented in this paper. Some basic topologies of output driver designs for implantable stimulators were reviewed. Some advanced techniques based on the reviewed designs to improve the performances were also presented. Since the safety and reliability are the primary concerns when realized the biomedical electronic devices, the on-chip stimulator designs for biomedical applications will continuously be an important design task in advanced CMOS technologies.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In current-controlled driver circuits, the amplitude control bits can be either translated directly to a stimulus current via a current-mode converter using binary-weighted and current-steering architectures or by means of a voltage-mode converter operating a transistor in triode mode as a voltage-controlled resistor (VCR).
“In current-controlled driver circuits, the amplitude control bits can be either translated directly to a stimulus current via a current-mode converter using binaryweighted and current-steering architectures or by means of a voltage-mode converter operating a transistor in triode mode as a voltage-controlled resistor (VCR) [138].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [138]
Cites
Impedance Characterization and Modeling of Electrodes for Biomedical Applications
Franks, W., Schenker, I., Schmutz, P., & Hierlemann, A. R. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.847523 · Cited by 660 · see citing works
A neuro-stimulus chip with telemetry unit for retinal prosthetic device
Liu, W., Vichienchom, K., Clements, M., DeMarco, S. C., Hughes, C., McGucken, E., Humayun, M. S., de Juan, E., Weiland, J. D., & Greenberg, R. J. (2000) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.871327 · Cited by 371 · see citing works
Functional Electrical Stimulation
Lynch, C. L., & Popović, M. R. (2008) · IEEE Control Systems · doi:10.1109/mcs.2007.914689 · Cited by 342 · see citing works
An Integrated 256-Channel Epiretinal Prosthesis
Chen, K., Yang, Z., Hoang, L., Weiland, J. D., Humayun, M. S., & Liu, W. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2055371 · Cited by 266 · see citing works
A 232-Channel Epiretinal Stimulator ASIC
Ortmanns, M., Rocke, A., Gehrke, M., & Tiedtke, H. J. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2007.908693 · Cited by 225 · see citing works
(2016) · BENTHAM SCIENCE PUBLISHERS eBooks · doi:10.2174/9781681082998116010006 · Cited by 156 · see citing works
Sivaprakasam, M., Liu, W., Humayun, M. S., & Weiland, J. D. (2005) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2005.843630 · Cited by 155 · see citing works
A Modular 32-site wireless neural stimulation microsystem
Ghovanloo, M., & Najafi, K. (2004) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2004.837026 · Cited by 149 · see citing works
Lee, J., Rhew, H.-G., Kipke, D. R., & Flynn, M. P. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2052403 · Cited by 140 · see citing works
Ghovanloo, M., & Najafi, K. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.839797 · Cited by 137 · see citing works
A Highly Flexible System for Microstimulation of the Visual Cortex: Design and Implementation
Coulombe, J., Sawan, M., & Gervais, J.-F. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.916026 · Cited by 129 · see citing works
An Integrated Implantable Stimulator That is Fail-Safe Without Off-Chip Blocking-Capacitors
Liu, X., Demosthenous, A., & Donaldson, N. (2008) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2008.2003199 · Cited by 118 · see citing works
A Power-Efficient Neural Tissue Stimulator With Energy Recovery
Kelly, S. K., & Wyatt, J. L. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2076384 · Cited by 107 · see citing works
An implantable wireless bidirectional communication microstimulator for neuromuscular stimulation
Lee, S.-Y., & Lee, S.-C. (2005) · IEEE Transactions on Circuits and Systems I Fundamental Theory and Applications · doi:10.1109/tcsi.2005.857770 · Cited by 104 · see citing works
Analysis of monophasic and biphasic electrical stimulation of nerve
Rubinstein, J. T., Miller, C. A., Mino, H., & Abbas, P. J. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.951508 · Cited by 84 · see citing works
Retinal Neurostimulator for a Multifocal Vision Prosthesis
Wong, Y. T., Dommel, N., Preston, P., Hallum, L. E., Lehmann, T., Lovell, N. H., & Suaning, G. J. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903958 · Cited by 79 · see citing works
A Partial-Current-Steering Biphasic Stimulation Driver for Vestibular Prostheses
Constandinou, T. G., Georgiou, J., & Toumazou, C. (2008) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2008.927238 · Cited by 76 · see citing works
Architecture tradeoffs in high-density microstimulators for retinal prosthesis
Sivaprakasam, M., Liu, W., Wang, G., Weiland, J. D., & Humayun, M. S. (2005) · IEEE Transactions on Circuits and Systems I Fundamental Theory and Applications · doi:10.1109/tcsi.2005.857554 · Cited by 74 · see citing works
An arbitrary waveform stimulus circuit for visual prostheses using a low-area multibias dac
DeMarco, S. C., Liu, W., Singh, P. R., Lazzi, G., Humayun, M. S., & Weiland, J. D. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.817264 · Cited by 73 · see citing works
Piallat, B., Chabardès, S., Devergnas, A. D., Torres-Martinez, N., Allain, M., Barrat, E., & Benabid, A. L. (2009) · Neurosurgery · doi:10.1227/01.neu.0000336331.88559.cf · Cited by 73 · see citing works
Exponential Current Pulse Generation for Efficient Very High-Impedance Multisite Stimulation
Ethier, S., & Sawan, M. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2073707 · Cited by 71 · see citing works
Tokuda, T., Hiyama, K., Sawamura, S., Sasagawa, K., Terasawa, Y., Nishida, K., Kitaguch, Y., Fujikado, T., Tano, Y., & Ohta, J. (2009) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2009.2030552 · Cited by 65 · see citing works
A Portable Wireless Online Closed-Loop Seizure Controller in Freely Moving Rats
Young, C.-P., Liang, S., Chang, D.-W., Liao, Y.-C., Shaw, F., & Hsieh, C.-H. (2010) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2010.2050358 · Cited by 64 · see citing works
A Stimulator ASIC Featuring Versatile Management for Vestibular Prostheses
Jiang, D., Demosthenous, A., Perkins, T. A., Liu, X., & Donaldson, N. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2138139 · Cited by 54 · see citing works
Electrical stimulation as therapy for neurological disorders
Testerman, R. L., Rise, M. T., & Stypulkowski, P. H. (2006) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2006.1705750 · Cited by 49 · see citing works
Diagnosis and Treatment of Neuropsychiatric Disorders
Taber, K. H., Hurley, R. A., & Yudofsky, S. C. (2010) · Annual Review of Medicine · doi:10.1146/annurev.med.051408.105018 · Cited by 48 · see citing works
Implantable Stimulator for Epileptic Seizure Suppression With Loading Impedance Adaptability
Lin, C., Chen, W., & Ker, M. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2200481 · Cited by 44 · see citing works
Self-citationA Tripolar Current-Steering Stimulator ASIC for Field Shaping in Deep Brain Stimulation
Valente, V., Demosthenous, A., & Bayford, R. H. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2171036 · Cited by 39 · see citing works
Tokuda, T., Takeuchi, Y., Sagawa, Y., Noda, T., Sasagawa, K., Nishida, K., Fujikado, T., & Ohta, J. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2078508 · Cited by 30 · see citing works
Compact Voltage and Current Stimulation Buffer for High-Density Microelectrode Arrays
Livi, P., Heer, F., Frey, U., Bakkum, D. J., & Hierlemann, A. R. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2080676 · Cited by 29 · see citing works
Biphasic-current-pulse self-calibration techniques for monopolar current stimulation
Guo, S., & Lee, H. (2009) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2009.5372085 · Cited by 28 · see citing works
Anesthesia for Pediatric Deep Brain Stimulation
Sebeo, J., Deiner, S. G., Alterman, R. L., & Osborn, I. P. (2010) · Anesthesiology Research and Practice · doi:10.1155/2010/401419 · Cited by 24 · see citing works
Monopolar vs. bipolar subretinal stimulation—An in vitro study
Gerhardt, M., Groeger, G., & MacCarthy, N. (2011) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2011.04.017 · Cited by 23 · see citing works
Toward A Fully Integrated Neurostimulator With Inductive Power Recovery Front-End
Mounaïm, F., & Sawan, M. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2185796 · Cited by 22 · see citing works
Implantable stimulator for bipolar stimulation without charge balancing circuits
Chun, H., Lehmann, T., & Yang, Y. (2010) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2010.5709606 · Cited by 20 · see citing works
Design of negative high voltage generator for biphasic stimulator with soc integration consideration
Huang, Y.-C., Ker, M., & Lin, C.-Y. (2012) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2012.6418477 · Cited by 18 · see citing works
Self-citationStimulus driver for epilepsy seizure suppression with adaptive loading impedance
Ker, M., Lin, C., & Chen, W.-L. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/6/066008 · Cited by 16 · see citing works
Self-citationUranga, A., Sacristán, J., Osés, T., & Barniol, N. (2007) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2007.904479 · Cited by 16 · see citing works
Therapeutic management of incontinence and pelvic pain : pelvic organ disorders
Haslam, J., & Laycock, J. (2002) · Springer eBooks · doi:10.1007/978-1-84628-756-5 · Cited by 14 · see citing works
A Stimulator Output Stage with Capacitor Reduction and Failure-Checking Techniques
Liu, X., Demosthenous, A., & Donaldson, N. (2006) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2006.1692667 · Cited by 14 · see citing works
Design and Medical Safety of Neuromuscular Incapacitation Devices [Emerging Technologies]
Panescu, D. (2007) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/emb.2007.901792 · Cited by 10 · see citing works
Lin, C., Li, Y.-J., & Ker, M. (2012) · IEEE International NEWCAS Conference (NEWCAS) · doi:10.1109/newcas.2012.6328972 · Cited by 10 · see citing works
Self-citationPhysiological description of the neuron and the human nervous system
Cantor, S. R., & Cantor, S. (2002) · Proceedings of the IEEE International Frequency Control Symposium · doi:10.1109/freq.1995.483877 · Cited by 5 · see citing works
Advances in implanted functional electrical stimulation
Soulier, F., Bernard, S., Cathébras, G., & Guiraud, D. (2011) · International Conference on Design & Technology of Integrated Systems in Nanoscale Era (DTIS) · doi:10.1109/dtis.2011.5941417 · Cited by 4 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
A High-Voltage-Tolerant and Precise Charge-Balanced Neuro-Stimulator in Low Voltage CMOS Process
Luo, Z., & Ker, M. (2016) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2015.2512443 · Cited by 84 · see citing works
Self-citationLuo, Z., Ker, M., Yang, T.-Y., & Cheng, W.-H. (2017) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2017.2713122 · Cited by 50 · see citing works
Self-citationLuo, Z., & Ker, M. (2018) · IEEE Journal on Emerging and Selected Topics in Circuits and Systems · doi:10.1109/jetcas.2018.2796381 · Cited by 38 · see citing works
Self-citationActive Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review
Habibollahi, M., Jiang, D., Lancashire, H. T., & Demosthenous, A. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3430038 · Cited by 11 · see citing works
“…the amplitude control bits can be either translated directly to a stimulus current via a current-mode converter using binary-weighted and current-steering architectures or by means of a voltage-mode converter operating a transistor in triode mode as a voltage-controlled resistor (VCR) [138].”
A multichannel current stimulator chip for spatiotemporal pattern stimulation of neural tissues
Kameda, S., Hayashida, Y., Tanaka, Y., Akita, D., & Yagi, T. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944750 · Cited by 5 · see citing works
Design Trade-Offs for Neural Stimulators Optimization
Hassan, A. H., Mohamed, Z. E., Fahmy, A. E., Mostafa, H., & Soliman, A. M. (2020) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas45731.2020.9180759 · Cited by 4 · see citing works
A 0.002‐mm 2 8‐bit 1‐MS/s low‐power time‐based DAC (T‐DAC)
Hassan, A. H., Mostafa, H., Refky, M. A., Salama, K. N., & Soliman, A. M. (2021) · IET Circuits Devices & Systems · doi:10.1049/cds2.12068 · Cited by 3 · see citing works
Design of H-Bridge Circuit for CMOS Stimulator and its Application Analysis
Liu, L. (2023) · IEEE International Conference on Image Processing and Computer Applications (ICIPCA) · doi:10.1109/icipca59209.2023.10257919 · Cited by 1 · see citing works
A Multi-channel Current Stimulator Chip for High Impedance Neural Electrodes
Kameda, S., Hayashida, Y., TANAKA, H., & Yagi, T. (2014) · Transactions of the Society of Instrument and Control Engineers · doi:10.9746/sicetr.50.594
- Authors
- Lin, C.-Y., & Ker, M.-D.
- Venue
- Journal of Neuroscience and Neuroengineering
- Publisher
- American Scientific Publishers
- Published
- 2012-12-01
- Volume
- 1
- Issue
- 2
- Pages
- 204-212
- ISSN
- 2168-2011 (ISSN-L)
- 2168-202X
- OpenAlex
- W2162255668
- Cited by
- 9
- References
- 44
- Citations by year
- 2024: 1 · 2023: 1 · 2021: 1 · 2020: 1 · 2018: 1 · 2017: 1 · 2016: 1 · 2014: 2
- FWCI
- 0.36
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Neuroscience and Neuroengineering (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
- Keywords
- implantable stimulator, CMOS integrated circuit, electrical stimulation, cardiac pacemaker, cochlear implants, muscle stimulation, vision restoration, seizure suppression, medical electronics, device reliability
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review