Cited by 9Analog and Mixed-Signal Circuit DesignNeuroscience and Neural EngineeringRadio Frequency Integrated Circuit Design

Overview of On-Chip Stimulator Designs for Biomedical Applications

Lin, Chun-Yu, Ker, Ming-Dou·2012·Journal of Neuroscience and Neuroengineering

Abstract

In recent years, the electrical stimulations have been used for biomedical applications, such as cardiac pacemaker, cochlear implant, muscle exercising, vision restoration, and seizure suppression. Comparing with the traditional treatments by using medicine or surgery, the electrical stimulation was more harmless, flexible, recoverable, and less-destructive. Moreover, with the potential for mass production, CMOS integrated circuits have been designed to implement the electrical stimulators. A comprehensive overview in the field of integrated circuit design for implantable stimulator was presented in this paper. Some basic topologies of output driver designs for implantable stimulators were reviewed. Some advanced techniques based on the reviewed designs to improve the performances were also presented. Since the safety and reliability are the primary concerns when realized the biomedical electronic devices, the on-chip stimulator designs for biomedical applications will continuously be an important design task in advanced CMOS technologies.

Integrity signals

Registry

Crossref · 10.1166/jnsne.2012.1023

Cites

44 of 44 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • In current-controlled driver circuits, the amplitude control bits can be either translated directly to a stimulus current via a current-mode converter using binary-weighted and current-steering architectures or by means of a voltage-mode converter operating a transistor in triode mode as a voltage-controlled resistor (VCR).

    “In current-controlled driver circuits, the amplitude control bits can be either translated directly to a stimulus current via a current-mode converter using binaryweighted and current-steering architectures or by means of a voltage-mode converter operating a transistor in triode mode as a voltage-controlled resistor (VCR) [138].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Lin, C.-Y., & Ker, M.-D.
Venue
Journal of Neuroscience and Neuroengineering
Published
2012-12-01
Volume
1
Issue
2
Pages
204-212
ISSN
  • 2168-2011 (ISSN-L)
  • 2168-202X
OpenAlex
W2162255668
Cited by
9
References
44
Citations by year
2024: 1 · 2023: 1 · 2021: 1 · 2020: 1 · 2018: 1 · 2017: 1 · 2016: 1 · 2014: 2
FWCI
0.36
Type
journal article
Language
en
Open access
closed
Locations
Journal of Neuroscience and Neuroengineering (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
Keywords
implantable stimulator, CMOS integrated circuit, electrical stimulation, cardiac pacemaker, cochlear implants, muscle stimulation, vision restoration, seizure suppression, medical electronics, device reliability

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review