Flexible Charge Balanced Stimulator With 5.6 fC Accuracy for 140 nC Injections
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Electrical stimulations of neuronal structures must ensure net injected charges to be zero for biological safety and voltage compliance reasons. We present a novel architecture of general purpose biphasic constant current stimulator that exhibits less than 5.6 fC error while injecting 140 nC charges using 1.4 mA currents. The floating current sources and conveyor switch based system can operate in monopolar or bipolar modes. Anodic-first or cathodic-first pulses with optional inter-phase delays have been demonstrated with zero quiescent current requirements at the analog front-end. The architecture eliminates blocking capacitors, electrode shorting and complex feedbacks. Bench-top and in-vivo measurement results have been presented with emulated electrode impedances (resistor-capacitor network), Ag-AgCl electrodes in saline and in-vivo (acute) peripheral nerve stimulations in anesthetized rats.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Translational principles of deep brain stimulation
Kringelbach, M. L., Jenkinson, N., Owen, S. L. F., & Aziz, T. Z. (2007) · Nature Reviews Neuroscience · doi:10.1038/nrn2196 · Cited by 853
Sit, J.-J., & Sarpeshkar, R. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.911631 · Cited by 155
An Integrated Implantable Stimulator That is Fail-Safe Without Off-Chip Blocking-Capacitors
Liu, X., Demosthenous, A., & Donaldson, N. (2008) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2008.2003199 · Cited by 118
Cited by
Pursuing prosthetic electronic skin
Chortos, A., Liu, J., & Bao, Z. (2016) · Nature Materials · doi:10.1038/nmat4671 · Cited by 2,396
A Complete 256-Electrode Retinal Prosthesis Chip
Tran, N., Bai, S., Yang, J., Chun, H., Kavehei, O., Yang, Y., Muktamath, V., Ng, D., Meffin, H., Halpern, M., et al. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2298037 · Cited by 90
A Multichannel High-Frequency Power-Isolated Neural Stimulator With Crosstalk Reduction
Jiang, D., & Demosthenous, A. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2832541 · Cited by 36
“The normalized charge error per phase was calculated following the procedure in [32], where the measured dc voltage was averaged into each”
MethodDoes a coupling capacitor enhance the charge balance during neural stimulation? An empirical study
van Dongen, M. N., & Serdijn, W. A. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1312-9 · Cited by 23
“Many studies have focused on designing stimulator output stages with accurate charge-balancing circuits [8, 13] in order to eliminate the need of coupling capacitors.”
BackgroundSensing of stimulus artifact suppressed signals from electrode interfaces.
Nag, S., Sikdar, S. K., Thakor, N. V., Rao, V. R., & Sharma, D. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2015.2399248 · Cited by 20
Self-citation
Metadata
- Authors
- Nag, S., Jia, X., Thakor, N., & Sharma, D.
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2013-06
- Volume
- 7
- Issue
- 3
- Pages
- 266-275
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- OpenAlex
- W2038563595
- Cited by
- 38
- References
- 3
- FWCI
- 1.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Flexible Charge Balanced Stimulator With 5.6 fC Accuracy for 140 nC Injections. https://app.cochat.ai/papers/10.1109/tbcas.2012.2205574
- The paper
- Nag, S., Jia, X., Thakor, N., & Sharma, D. (2013). Flexible Charge Balanced Stimulator With 5.6 fC Accuracy for 140 nC Injections. IEEE Transactions on Biomedical Circuits and Systems. https://doi.org/10.1109/tbcas.2012.2205574
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.