Design and Optimization of Ultrasonic Wireless Power Transmission Links for Millimeter-Sized Biomedical Implants
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Ultrasound has been recently proposed as an alternative modality for efficient wireless power transmission (WPT) to biomedical implants with millimeter (mm) dimensions. This paper presents the theory and design methodology of ultrasonic WPT links that involve mm-sized receivers (Rx). For given load (RL) and powering distance (d), the optimal geometries of transmitter (Tx) and Rx ultrasonic transducers, including their diameter and thickness, as well as the optimal operation frequency (fc) are found through a recursive design procedure to maximize the power transmission efficiency (PTE). First, a range of realistic fcs is found based on the Rx thickness constrain. For a chosen fcwithin the range, the diameter and thickness of the Rx transducer are then swept together to maximize PTE. Then, the diameter and thickness of the Tx transducer are optimized to maximize PTE. Finally, this procedure is repeated for different fcs to find the optimal fc and its corresponding transducer geometries that maximize PTE. A design example of ultrasonic link has been presented and optimized for WPT to a 1 mm3implant, including a disk-shaped piezoelectric transducer on a silicon die. In simulations, a PTE of 2.11% at fc of 1.8 MHz was achieved for RL of 2.5 kΩ at d = 3 cm. In order to validate our simulations, an ultrasonic link was optimized for a 1 mm3 piezoelectric transducer mounted on a printed circuit board (PCB), which led to simulated and measured PTEs of 0.65% and 0.66% at fcof 1.1 MHz for RL of 2.5 kΩ at d = 3 cm, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wirelessly powered, fully internal optogenetics for brain, spinal and peripheral circuits in mice
Montgomery, K. L., Yeh, A. J., Ho, J. S., Tsao, V., Mohan Iyer, S., Grosenick, L., Ferenczi, E. A., Tanabe, Y., Deisseroth, K., Delp, S. L., et al. (2015) · Nature Methods · doi:10.1038/nmeth.3536 · Cited by 565 · cited 1×
“and even optogenetics can be achieved with power requirements from hundreds of μW to several mWs [7], [8].”
BackgroundWireless power transfer to deep-tissue microimplants
Ho, J. S., Yeh, A. J., Neofytou, E., Kim, S., Tanabe, Y., Patlolla, B., Beygui, R. E., & Poon, A. S. Y. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1403002111 · Cited by 541 · cited 1×
“5% for a 1 mm3 receiver (Rx) coil/antenna at the powering distance (d) of ∼10 mm [10]–[12].”
BackgroundMcConnell, G. C., Rees, H. D., Levey, A. I., Gutekunst, C.-A., Gross, R. E., & Bellamkonda, R. V. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/5/056003 · Cited by 480
Charthad, J., Weber, M. J., Chang, T. C., & Arbabian, A. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2015.2427336 · Cited by 245 · cited 3×
“However, as Do2 is increased, Rx transducer resistance at resonance is also changed, affecting PTE for a given RL [18].”
BackgroundMethodNeural Dust: An Ultrasonic, Low Power Solution for Chronic Brain-Machine Interfaces
Seo, D., Carmena, J. M., Rabaey, J. M., Alon, E., & Maharbiz, M. M. (2013) · arXiv · doi:10.48550/arxiv.1307.2196 · Cited by 172
Model validation of untethered, ultrasonic neural dust motes for cortical recording
Seo, D., Carmena, J. M., Rabaey, J. M., Maharbiz, M. M., & Alon, E. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.07.025 · Cited by 158 · cited 4×
“Finally, it has been shown in [20] that 0.”
BackgroundMethodResultInfluential
Cited by
Advances in High-Power Wireless Charging Systems: Overview and Design Considerations
Feng, H., Tavakoli, R., Onar, O. C., & Pantic, Z. (2020) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2020.3012543 · Cited by 368
Micro triboelectric ultrasonic device for acoustic energy transfer and signal communication
Chen, C., Wen, Z., Shi, J., Jian, X., Li, P., Yeow, J. T. W., & Sun, X. (2020) · Nature Communications · doi:10.1038/s41467-020-17842-w · Cited by 284
A mm-Sized Wireless Implantable Device for Electrical Stimulation of Peripheral Nerves
Charthad, J., Chang, T. C., Liu, Z., Sawaby, A., Weber, M. J., Baker, S., Gore, F., Felt, S. A., & Arbabian, A. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2799623 · Cited by 230
“advantages, including: (i) energy focusing at large depths (>10 cm) to a mm spot size which enables high power transfer efficiency compared to RF far-field powering [28], [30]–[32], (ii) superior transduction efficiency due to ∼mm wavelength [27], [33], and (iii) low tissue attenuation (∼0.”
BackgroundSagar, A., Kashyap, A., Nasab, M. A., Padmanaban, S., Bertoluzzo, M., Kumar, A., & Blaabjerg, F. (2023) · IEEE Access · doi:10.1109/access.2023.3300475 · Cited by 230
“or any other medium [308], [309], [310].”
Wireless power transfer approaches for medical implants: a review
Haerinia, M., & Shadid, R. (2020) · Signals · doi:10.3390/signals1020012 · Cited by 174
Metadata
- Authors
- Meng, M., & Kiani, M.
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2017-02
- Volume
- 11
- Issue
- 1
- Pages
- 98-107
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- OpenAlex
- W2522532459
- Cited by
- 118
- References
- 6
- FWCI
- 5.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.