A Real-Time QRS Detection System With PR/RT Interval and ST Segment Measurements for Wearable ECG Sensors Using Parallel Delta Modulators
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
This paper presents a real-time electrocardiogram (ECG) monitoring system for wearable devices. The system is based on the proposed parallel delta modulator architecture with local maximum point and local minimum point algorithms to detect QRS and PT waves. Therefore, using the proposed system and algorithm, real-time PR and RT intervals, and ST segment measurements can be achieved in long-term wearable ECG recording. The algorithm is tested with the MIT-BIH Arrhythmia Database for QRS complex detection and with the QT Database for the P and T wave detections. The simulation result shows that the algorithm achieves above 99%, 91%, and 98% accuracy in the QRS complex, P wave, and T wave detections, respectively. Experimental results are presented from the system prototype, in which the parallel delta modulator circuits are fabricated in IBM 0.13 $\mu \text{m}$ standard CMOS technology and the algorithms are implemented in a Xilinx Spartan-6 field programmable gate array (FPGA). The parallel delta modulators consume 720 nW at 1 kHz sampling rate with $\pm$0.6 V power supply. The proposed system has the potential to be applied in future long-term wearable ECG recording devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Heart Disease and Stroke Statistics—2017 Update: A Report From the American Heart Association
Benjamin, E. J., Blaha, M. J., Chiuve, S. E., Cushman, M., Das, S. R., Deo, R., de Ferranti, S. D., Floyd, J., Fornage, M., Gillespie, C., et al. (2017) · Circulation · doi:10.1161/cir.0000000000000485 · Cited by 12,591
Long-term Outcomes in Individuals With Prolonged PR Interval or First-Degree Atrioventricular Block
Cheng, S. (2009) · JAMA · doi:10.1001/jama.2009.888 · Cited by 614
Chuo, Y., Marzencki, M., Hung, B., Jaggernauth, C., Tavakolian, K., Lin, P., & Kaminska, B. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2052616 · Cited by 102
A 0.7-V 17.4-/spl mu/W 3-Lead Wireless ECG SoC
Khayatzadeh, M., Zhang, X., Tan, J., Liew, W.-S., & Lian, Y. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2279398 · Cited by 73 · cited 1×
“asynchronous Delta modulators [11], [46], [47] have very low power consumption, our proposed system achieves similar accuracy in QRS detection.”
Method
Cited by
Hu, Q., Tang, X., & Tang, W. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2980207 · Cited by 94
Self-citationA Review of Embedded Machine Learning Based on Hardware, Application, and Sensing Scheme
Biglari, A., & Tang, W. (2023) · Sensors · doi:10.3390/s23042131 · Cited by 86
Self-citationA Smart Sensing System of Water Quality and Intake Monitoring for Livestock and Wild Animals
Tang, W., Biglari, A., Ebarb, R., Pickett, T., Smallidge, S., & Ward, M. (2021) · Sensors · doi:10.3390/s21082885 · Cited by 26
Self-citation
Metadata
- Authors
- Tang, X., Hu, Q., & Tang, W.
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2018-08
- Volume
- 12
- Issue
- 4
- Pages
- 751-761
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- OpenAlex
- W2886357685
- Cited by
- 94
- References
- 5
- FWCI
- 6.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Real-Time QRS Detection System With PR/RT Interval and ST Segment Measurements for Wearable ECG Sensors Using Parallel Delta Modulators. https://app.cochat.ai/papers/10.1109/tbcas.2018.2823275
- The paper
- Tang, X., Hu, Q., & Tang, W. (2018). A Real-Time QRS Detection System With PR/RT Interval and ST Segment Measurements for Wearable ECG Sensors Using Parallel Delta Modulators. IEEE Transactions on Biomedical Circuits and Systems. https://doi.org/10.1109/tbcas.2018.2823275
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.