The DOI matches its Crossref record; 101 of the 104 references it cites were found in a registry or an index.
Miniaturised Wireless Power Transfer Systems for Neurostimulation: A Review
Open accessAbstract
In neurostimulation, wireless power transfer is an efficient technology to overcome several limitations affecting medical devices currently used in clinical practice. Several methods were developed over the years for wireless power transfer. In this review article, we report and discuss the three most relevant methodologies for extremely miniaturised implantable neurostimulators: ultrasound coupling, inductive coupling and capacitive coupling. For each powering method, the discussion starts describing the physical working principle. In particular, we focus on the challenges given by the miniaturisation of the implanted integrated circuits and the related ad-hoc solutions for wireless power transfer. Then, we present recent developments and progresses in wireless power transfer for biomedical applications. Last, we compare each technique based on key performance indicators to highlight the most relevant and innovative solutions suitable for neurostimulation, with the gaze turned towards miniaturisation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Moreover, cables and connectors apply mechanical forces on the implant and the tissue, causing long-term scarring [201].”
From Advances in visual prostheses: engineering and biological challenges (2022) · cites this paper as [201]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Simple accurate expressions for planar spiral inductances
Mohan, S. S., Hershenson, M. D. M., Boyd, S., & Lee, T. H. (1999) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.792620 · Cited by 1,627
Deep brain stimulation of the subthalamic nucleus for the treatment of Parkinson's disease
Benabid, A. L., Chabardes, S., Mitrofanis, J., & Pollak, P. (2009) · The Lancet Neurology · doi:10.1016/s1474-4422(08)70291-6 · Cited by 1,285
Double-negative acoustic metamaterial
Li, J., & Chan, C. T. (2004) · Physical Review E · doi:10.1103/physreve.70.055602 · Cited by 1,153
Targeted neurotechnology restores walking in humans with spinal cord injury
Wagner, F. B., Mignardot, J.-B., Le Goff-Mignardot, C. G., Demesmaeker, R., Komi, S., Capogrosso, M., Rowald, A., Seáñez, I., Caban, M., Pirondini, E., et al. (2018) · Nature · doi:10.1038/s41586-018-0649-2 · Cited by 1,087
Restoring natural sensory feedback in real-time bidirectional hand prostheses
Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006820 · Cited by 1,001
Electromechanical transducers and wave filters
Mason, W. P. (1942) · Virtual Defense Library (Ministerio de Defensa) · Cited by 957
New equivalent circuits for elementary piezoelectric transducers
Krimholtz, R. S., Leedom, D. A., & Matthaei, G. L. (1970) · Electronics Letters · doi:10.1049/el:19700280 · Cited by 816
Energy Scavenging for Wireless Sensor Networks
Roundy, S., Wright, P. K., & Rabaey, J. M. (2004) · Springer eBooks · doi:10.1007/978-1-4615-0485-6 · Cited by 795
Wheeler, H. A. (1942) · Proceedings of the IRE · doi:10.1109/jrproc.1942.232015 · Cited by 759
Jow, U.-M., & Ghovanloo, M. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.913130 · Cited by 628
Research works printed but not linked: 4
- ritchey, 1999, A survey and tutorial of dielectric materials used in the manufacture of printed circuit boards, CircuiTree Mag
- 10.1109/TBCAS.2017.2663358 · DOI
- marefat, 0, Proc IEEE Int Solid-State Circuits Conf, 412
- zou, 2019, Modelling single-wire capacitive power transfer system with strong coupling to ground, IEEE J Emerg Sel Topics Power Electron
Cited by
Sorted by citations
Recent Advancements in Emerging Technologies for Healthcare Management Systems: A Survey
Junaid, S. B., Imam, A. A., Balogun, A. O., Silva, L. C. D., Surakat, Y. A., Kumar, G., Abdulkarim, M., Shuaibu, A. N., Garba, A., Sahalu, Y., et al. (2022) · Healthcare · doi:10.3390/healthcare10101940 · Cited by 398
Wireless power delivery techniques for miniature implantable bioelectronics
Singer, A., & Robinson, J. T. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100664 · Cited by 159
Wireless Power Transfer—A Review
Detka, K., & Górecki, K. (2022) · Energies · doi:10.3390/en15197236 · Cited by 140
Erel, M. Z., Bayındır, K. Ç., Aydemir, M. T., Chaudhary, S. K., & Guerrero, J. M. (2021) · IEEE Access · doi:10.1109/access.2021.3139761 · Cited by 138
Miniature battery-free bioelectronics
Nair, V., Dalrymple, A. N., Yu, Z., Balakrishnan, G., Bettinger, C. J., Weber, D. J., Yang, K., & Robinson, J. T. (2023) · Science · doi:10.1126/science.abn4732 · Cited by 128
Metadata
- Authors
- Barbruni, G. L., Ros, P. M., Demarchi, D., Carrara, S., & Ghezzi, D.
- Affiliations
- Politecnico di Torino (IT)
- École Polytechnique Fédérale de Lausanne (CH)
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2020-12
- Volume
- 14
- Issue
- 6
- Pages
- 1160-1178
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- OpenAlex
- W3102254533
- Cited by
- 161
- References
- 104
- Citations by year
- 2026: 19 · 2025: 30 · 2024: 21 · 2023: 39 · 2022: 32 · 2021: 20
- FWCI
- 1.13
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- IEEE Transactions on Biomedical Circuits and Systems (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
- PORTO@Iris (submittedVersion, cc-by)
- Funders
- École Polytechnique Fédérale de Lausanne
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Keywords
- wireless power transfer, neurostimulation, implantable neurostimulator, miniaturization, inductive coupling, capacitive coupling, biomedical devices
- MeSH terms
- Biomedical Engineering, Brain, Humans, Miniaturization, Electric Power Supplies, Prosthesis Design, Implantable Neurostimulators, Wireless Technology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review