The DOI matches its Crossref record; 101 of the 104 references it cites were found in a registry or an index.
Miniaturised Wireless Power Transfer Systems for Neurostimulation: A Review
Open accessAbstract
In neurostimulation, wireless power transfer is an efficient technology to overcome several limitations affecting medical devices currently used in clinical practice. Several methods were developed over the years for wireless power transfer. In this review article, we report and discuss the three most relevant methodologies for extremely miniaturised implantable neurostimulators: ultrasound coupling, inductive coupling and capacitive coupling. For each powering method, the discussion starts describing the physical working principle. In particular, we focus on the challenges given by the miniaturisation of the implanted integrated circuits and the related ad-hoc solutions for wireless power transfer. Then, we present recent developments and progresses in wireless power transfer for biomedical applications. Last, we compare each technique based on key performance indicators to highlight the most relevant and innovative solutions suitable for neurostimulation, with the gaze turned towards miniaturisation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Moreover, cables and connectors apply mechanical forces on the implant and the tissue, causing long-term scarring [201].”
From Advances in visual prostheses: engineering and biological challenges (2022) · cites this paper as [201]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Simple accurate expressions for planar spiral inductances
Mohan, S. S., Hershenson, M. D. M., Boyd, S., & Lee, T. H. (1999) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.792620 · Cited by 1,627
Deep brain stimulation of the subthalamic nucleus for the treatment of Parkinson's disease
Benabid, A. L., Chabardes, S., Mitrofanis, J., & Pollak, P. (2009) · The Lancet Neurology · doi:10.1016/s1474-4422(08)70291-6 · Cited by 1,285
Double-negative acoustic metamaterial
Li, J., & Chan, C. T. (2004) · Physical Review E · doi:10.1103/physreve.70.055602 · Cited by 1,153
Targeted neurotechnology restores walking in humans with spinal cord injury
Wagner, F. B., Mignardot, J.-B., Le Goff-Mignardot, C. G., Demesmaeker, R., Komi, S., Capogrosso, M., Rowald, A., Seáñez, I., Caban, M., Pirondini, E., et al. (2018) · Nature · doi:10.1038/s41586-018-0649-2 · Cited by 1,087
Restoring natural sensory feedback in real-time bidirectional hand prostheses
Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006820 · Cited by 1,001
Electromechanical transducers and wave filters
Mason, W. P. (1942) · Virtual Defense Library (Ministerio de Defensa) · Cited by 957
New equivalent circuits for elementary piezoelectric transducers
Krimholtz, R. S., Leedom, D. A., & Matthaei, G. L. (1970) · Electronics Letters · doi:10.1049/el:19700280 · Cited by 816
Energy Scavenging for Wireless Sensor Networks
Roundy, S., Wright, P. K., & Rabaey, J. M. (2004) · Springer eBooks · doi:10.1007/978-1-4615-0485-6 · Cited by 795
Wheeler, H. A. (1942) · Proceedings of the IRE · doi:10.1109/jrproc.1942.232015 · Cited by 759
Jow, U.-M., & Ghovanloo, M. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.913130 · Cited by 628
Design and Optimization of a 3-Coil Inductive Link for Efficient Wireless Power Transmission
Kiani, M., Jow, U.-M., & Ghovanloo, M. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2158431 · Cited by 560
Optimal Frequency for Wireless Power Transmission Into Dispersive Tissue
Poon, A. S. Y., O'Driscoll, S., & Meng, T. H. (2010) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2010.2044310 · Cited by 469
Piech, D. K., Johnson, B. C., Shen, K., Ghanbari, M. M., Li, K. Y., Neely, R. M., Kay, J. E., Carmena, J. M., Maharbiz, M. M., & Muller, R. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0518-9 · Cited by 442
Wireless power transfer techniques for implantable medical devices: a review
Khan, S. R., Pavuluri, S. K., Cummins, G., & Desmulliez, M. P. Y. (2020) · Sensors · doi:10.3390/s20123487 · Cited by 355 · cited 1×
“Differently from other works [8], [9], [10] this review compares the advantages as well as the critical limitations of each powering method in designing a wireless link”
Analysis of current crowding effects in multiturn spiral inductors
Kuhn, W. B., & Ibrahim, N. M. (2001) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/22.899959 · Cited by 340
Tzou, H. S. (1993) · Solid mechanics and its applications · doi:10.1007/978-94-011-1783-8 · Cited by 340
A Review on the Recent Development of Capacitive Wireless Power Transfer Technology
Lu, F., Zhang, H., & Mi, C. C. (2017) · Energies · doi:10.3390/en10111752 · Cited by 282
Designing Efficient Inductive Power Links for Implantable Devices
Harrison, R. (2007) · 2007 IEEE International Symposium on Circuits and Systems · doi:10.1109/iscas.2007.378508 · Cited by 263
Charthad, J., Weber, M. J., Chang, T. C., & Arbabian, A. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2015.2427336 · Cited by 245 · cited 1×
“72 mW/mm(2) (10% of the maximum FDA diagnostic limit) [90].”
BackgroundOptimal Design of Wireless Power Transmission Links for Millimeter-Sized Biomedical Implants
Ahn, D., & Ghovanloo, M. (2015) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2370794 · Cited by 245
Ultrasonic transcutaneous energy transfer for powering implanted devices.
Ozeri, S., & Shmilovitz, D. (2010) · Ultrasonics · doi:10.1016/j.ultras.2009.11.004 · Cited by 241
Modeling and optimization of printed spiral coils in air, saline, and muscle tissue environments
Jow, U.-M., & Ghovanloo, M. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2009.2025366 · Cited by 241
A review of acoustic power transfer for bio-medical implants
Basaeri, H., Christensen, D. B., & Roundy, S. (2016) · Smart Materials and Structures · doi:10.1088/0964-1726/25/12/123001 · Cited by 202
A New Analytical Calculation of the Mutual Inductance of the Coaxial Spiral Rectangular Coils
Cheng, Y., & Shu, Y. (2013) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2013.2290972 · Cited by 192
Wireless Power Delivery to Flexible Subcutaneous Implants Using Capacitive Coupling
Jegadeesan, R., Agarwal, K., Guo, Y., Yen, S.-C., & Thakor, N. V. (2016) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2016.2615623 · Cited by 189
Ultrasonic vs. Inductive Power Delivery for Miniature Biomedical Implants
Denisov, A., & Yeatman, E. (2010) · 2010 International Conference on Body Sensor Networks · doi:10.1109/bsn.2010.27 · Cited by 185
Biointegrated and Wirelessly Powered Implantable Brain Devices: A Review
Das, R., Moradi, F., & Heidari, H. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.2966920 · Cited by 174
Assessing Human Exposure to Electromagnetic Fields From Wireless Power Transmission Systems
Christ, A., Douglas, M. G., Nadakuduti, J., & Kuster, N. (2013) · Proceedings of the IEEE · doi:10.1109/jproc.2013.2245851 · Cited by 173
Practical Inductive Link Design for Biomedical Wireless Power Transfer: A Tutorial
Schormans, M., Valente, V., & Demosthenous, A. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2846020 · Cited by 170
A Fully-Integrated, Miniaturized (0.125 mm²) 10.5 µW Wireless Neural Sensor
Biederman, W., Yeager, D. J., Narevsky, N., Koralek, A. C., Carmena, J. M., Alon, E., & Rabaey, J. M. (2013) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2238994 · Cited by 167
Capacitive coupling for power and data telemetry to implantable biomedical microsystems
Sodagar, A. M., & Amiri, P. (2009) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2009.5109320 · Cited by 164
A brief history of cardiac pacing.
Nelson, G. (1993) · PubMed · Cited by 163
The Effect of Insulating Layers on the Performance of Implanted Antennas
Merli, F., Fuchs, B., Mosig, J. R., & Skrivervik, A. K. (2010) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2010.2090465 · Cited by 161
Model validation of untethered, ultrasonic neural dust motes for cortical recording
Seo, D., Carmena, J. M., Rabaey, J. M., Maharbiz, M. M., & Alon, E. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.07.025 · Cited by 158
A Sub-mm 3 Ultrasonic Free-Floating Implant for Multi-Mote Neural Recording
Ghanbari, M. M., Piech, D. K., Shen, K., Alamouti, S. F., Yalcin, C., Johnson, B. C., Carmena, J. M., Maharbiz, M. M., & Muller, R. (2019) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2019.2936303 · Cited by 137
Wireless Power Transfer for Implanted Medical Application: A Review
Zhou, Y., Liu, C., & Huang, Y. (2020) · Energies · doi:10.3390/en13112837 · Cited by 135
Robust Wireless Power Transmission to mm-Sized Free-Floating Distributed Implants
Mirbozorgi, S. A., Yeon, P., & Ghovanloo, M. (2017) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2017.2663358 · Cited by 131
Ensminger, D., & Bond, L. J. (2011) · CRC Press eBooks · doi:10.1201/b11173 · Cited by 127
A brief history of cardiac pacing.
Aquilina, O. (2006) · PubMed · Cited by 123
The Microbead: A 0.009 mm 3 Implantable Wireless Neural Stimulator
Khalifa, A., Liu, Y., Karimi, Y., Wang, Q., Eisape, A. A., Stanaćević, M., Thakor, N. V., Bao, Z., & Etienne‐Cummings, R. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2939014 · Cited by 121
Meng, M., & Kiani, M. (2016) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2016.2583783 · Cited by 120
Ibrahim, A., & Kiani, M. (2016) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2016.2515541 · Cited by 110
Simple and accurate formulas for a microstrip with finite strip thickness
Bahl, I. J., & Garg, R. (1977) · Proceedings of the IEEE · doi:10.1109/proc.1977.10783 · Cited by 109
Sedehi, R., Budgett, D., Jiang, J., Ziyi, X., Dai, X., Hu, A. P., & McCormick, D. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3009048 · Cited by 109
Evaluation of Cardiovascular Stents as Antennas for Implantable Wireless Applications
Chow, E. Y., Ouyang, Y., Beier, B. L., Chappell, W. J., & Irazoqui, P. P. (2009) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2009.2029954 · Cited by 101
Omnidirectional Ultrasonic Powering for Millimeter-Scale Implantable Devices
Song, S.-H., Kim, A., & Ziaie, B. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2444854 · Cited by 95
Erfani, R., Marefat, F., Sodagar, A. M., & Mohseni, P. (2017) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2017.2737140 · Cited by 88
Retinal prostheses: progress toward the next generation implants
Ghezzi, D. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2015.00290 · Cited by 83
Self-citationIbrahim, A., Meng, M., & Kiani, M. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2812420 · Cited by 83
Pieters, P., Vaesen, K., Brebels, S., Mahmoud, S. F., Raedt, W. D., Beyne, E., & Mertens, R. (2001) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/22.915431 · Cited by 79
Ultrasonics: Fundamentals, Technologies, and Applications, Third Edition
Ensminger, D., & Bond, L. J. (2011) · Medical Entomology and Zoology · Cited by 75
Gevorgian, S., Berg, H., Jacobsson, H., & Lewin, T. (2003) · IEEE Microwave Magazine · doi:10.1109/mmw.2003.1201599 · Cited by 66
Paediatric cochlear implantation: prosthetic hearing and language development
Rubinstein, J. T. (2002) · The Lancet · doi:10.1016/s0140-6736(02)09679-4 · Cited by 64
Atluri, S., & Ghovanloo, M. (2005) · Conference Proceedings. 2nd International IEEE EMBS Conference on Neural Engineering, 2005. · doi:10.1109/cne.2005.1419677 · Cited by 64
Midfield Wireless Power Transfer for Bioelectronics
Ma, A., & Poon, A. S. Y. (2015) · IEEE Circuits and Systems Magazine · doi:10.1109/mcas.2015.2418999 · Cited by 63
Matching ultrasonic transducer using two matching layers where one of them is glue
Callens, D., Bruneel, C., & Assaad, J. (2004) · NDT & E International · doi:10.1016/j.ndteint.2004.03.005 · Cited by 62
Modeling of capacitive resonant wireless power and data transfer to deep biomedical implants
Narayanamoorthi, R. (2019) · IEEE Transactions on Components, Packaging and Manufacturing Technology · doi:10.1109/tcpmt.2019.2922046 · Cited by 62
Towards a Distributed, Chronically-Implantable Neural Interface
Ahmadi, N., Cavuto, M. L., Feng, P., Leene, L. B., Maslik, M., Mazza, F., Savolainen, O. W., Szostak, K. M., Bouganis, C.-S., Ekanayake, J., et al. (2019) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2019.8716998 · Cited by 56
An Implantable Wireless Network of Distributed Microscale Sensors for Neural Applications
Lee, J., Lee, F., Huang, J., Cui, L., Lee, A.-H., Leung, V., Mercier, P., Shellhammer, S., Larson, L., Asbeck, P., et al. (2019) · 2019 9th International IEEE/EMBS Conference on Neural Engineering (NER) · doi:10.1109/ner.2019.8717023 · Cited by 54
Chang, T. C., Weber, M. J., Charthad, J., Baltsavias, S., & Arbabian, A. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2871470 · Cited by 53
Accurate Expressions of Mutual Inductance and Their Calculation of Archimedean Spiral Coils
Liu, S., Su, J., & Lai, J. (2019) · Energies · doi:10.3390/en12102017 · Cited by 44
Transcutaneous capacitive wireless power transfer (C-WPT) for biomedical implants
Erfani, R., Marefat, F., Sodagar, A. M., & Mohseni, P. (2017) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2017.8050940 · Cited by 43
Erfani, R., Marefat, F., Nag, S., & Mohseni, P. (2019) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2019.2956883 · Cited by 43
Meng, M., & Kiani, M. (2016) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2016.2626151 · Cited by 42
Erfani, R., Marefat, F., Sodagar, A. M., & Mohseni, P. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2824281 · Cited by 42
Towards a Smart Experimental Arena for Long-Term Electrophysiology Experiments
Jow, U.-M., Kiani, M., Huo, X., & Ghovanloo, M. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2211872 · Cited by 41
A single-wire capacitive power transfer system with large coupling alignment tolerance
Zou, L. J., Hu, A. P., & Su, Y. (2017) · IEEE PELS Workshop on Emerging Technologies: Wireless Power Transfer · doi:10.1109/wow.2017.7959372 · Cited by 38
RFID Tag Helix Antenna Sensors for Wireless Drug Dosage Monitoring
Huang, H., Zhao, P., Chen, P., Ren, Y., Liu, X., Mauro Ferrari, B., Hu, Y., & Akinwande, D. (2014) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2014.2309335 · Cited by 37
Wireless Power and Data Link for Ensembles of Sub-mm scale Implantable Sensors near 1GHz
Lee, J.-H., Laiwalla, F., Jeong, J., Kilfoyle, C., Larson, L. E., Nurmikko, A. V., Li, S., Yu, S., & Leung, V. (2018) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2018.8584725 · Cited by 35
Ultrasonic beamforming system for interrogating multiple implantable sensors
Seo, D., Tang, H.-Y., Carmena, J. M., Rabaey, J. M., Alon, E., Boser, B. E., & Maharbiz, M. M. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7318942 · Cited by 34
Design and optimization of inductive power transmission for implantable sensor system
Kilinc, E. G., Dehollain, C., & Maloberti, F. (2010) · doi:10.1109/sm2acd.2010.5672335 · Cited by 33
Phosphene perceptions and safety of chronic visual cortex stimulation in a blind subject
Niketeghad, S., Muralidharan, A., Patel, U., Dorn, J. D., Bonelli, L., Greenberg, R. J., & Pouratian, N. (2020) · Journal of Neurosurgery · doi:10.3171/2019.3.jns182774 · Cited by 33
Basaeri, H., Yu, Y., Young, D. J., & Roundy, S. (2019) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/ab257f · Cited by 33
Laiwalla, F., Lee, J.-H., Lee, A., Lee, F., Leung, V., Shellhammer, S., Song, Y., Larson, L. E., & Nurmikko, A. V. (2019) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8857217 · Cited by 32
Modeling of a capacitive link for data telemetry to biomedical implants
Takhti, M., Asgarian, F., & Sodagar, A. M. (2011) · Biomedical Circuits and Systems Conference · doi:10.1109/biocas.2011.6107757 · Cited by 30
Biosafety Considerations of a Capacitive Link for Wireless Power Transfer to Biomedical Implants
Erfani, R., Marefat, F., & Mohseni, P. (2018) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2018.8584827 · Cited by 29
Auto-Resonant Tuning for Capacitive Power and Data Telemetry Using Flexible Patches
Nag, S., Koruprolu, A., Saikh, S. M., Erfani, R., & Mohseni, P. (2019) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2019.2955568 · Cited by 27
Example of Data Telemetry for Biomedical Applications: An In Vivo Experiment
Merli, F., Bolomey, L., Gorostidi, F., Fuchs, B., Zürcher, J., Barrandon, Y., Meurville, E., Mosig, J. R., & Skrivervik, A. K. (2012) · IEEE Antennas and Wireless Propagation Letters · doi:10.1109/lawp.2013.2238500 · Cited by 24
EM-Lens Enhanced Power Transfer and Multi-Node Data Transmission for Implantable Medical Devices
Feng, P., Maslik, M., & Constandinou, T. G. (2019) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2019.8919152 · Cited by 24
Design of a Small Modified Minkowski Fractal Antenna for Passive Deep Brain Stimulation Implants
Manafi, S., & Deng, H. (2014) · International Journal of Antennas and Propagation · doi:10.1155/2014/749043 · Cited by 23
Bertrand, A., Seo, D., Maksimovic, F., Carmena, J. M., Maharbiz, M. M., Alon, E., & Rabaey, J. M. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944161 · Cited by 21
Optimal design of a 3-coil inductive link for millimeter-sized biomedical implants
Yeon, P., Mirbozorgi, S. A., & Ghovanloo, M. (2016) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2016.7833815 · Cited by 21
Equation-Based Optimization for Inductive Power Transfer to a Miniature CMOS Rectenna
Kuo, N., Zhao, B., & Niknejad, A. M. (2018) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2018.2793910 · Cited by 20
The vibration characteristics of piezoelectric discs
Guo, N. (1990) · Spiral (Imperial College London) · Cited by 19
Zhao, B., Kuo, N., Liu, B., Li, Y.-A., Iotti, L., & Niknejad, A. M. (2019) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2019.2954772 · Cited by 19
Self-Image-Guided Ultrasonic Wireless Power Transmission to Millimeter-Sized Biomedical Implants
Meng, M., & Kiani, M. (2019) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8857559 · Cited by 18
Spatial carrier position modulation based multichannel capacitive link for bioelectronic implants
Hassan, A., Sawma, C., Hasanuzzaman, M., Gosselin, B., & Sawan, M. (2015) · Biomedical Circuits and Systems Conference · doi:10.1109/biocas.2015.7348292 · Cited by 17
Robust Wireless Power Transfer to Multiple mm-Scale Freely-Positioned Neural Implants
Feng, P., & Constandinou, T. G. (2018) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2018.8584730 · Cited by 16
Safe inductive power transmission to millimeter-sized implantable microelectronics devices
Ibrahim, A., & Kiani, M. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7318487 · Cited by 13
Millimeter-scale integrated and wirewound coils for powering implantable neural microsystems
Feng, P., Constandinou, T. G., Yeon, P., & Ghovanloo, M. (2017) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2017.8325184 · Cited by 13
Antenna design for implanted tags in wireless brain machine interface system
Moradi, E., Björninen, T., Sydanheimo, L. T., Ukkonen, L., & Rabaey, J. M. (2013) · Digest - IEEE Antennas and Propagation Society. International Symposium · doi:10.1109/aps.2013.6711700 · Cited by 12
Folded loop antenna as a promissing solution for a cochlear implant
Vorobyov, A. V., Hennemann, C., Vasylchenko, A., Decotignie, J.-D., & Baumgartner, J. (2014) · European Conference on Antennas and Propagation · doi:10.1109/eucap.2014.6902127 · Cited by 11
Meng, M., Ibrahim, A., & Kiani, M. (2015) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2015.7348295 · Cited by 11
Lee, J.-H., Leung, V., Lee, A., Huang, J., Asbeck, P. M., Mercier, P. P., Shellhammer, S. J., Larson, L. E., Laiwalla, F., & Nurmikko, A. V. (2020) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2020.09.11.293829 · Cited by 11
A mm-Sized Free-Floating Wireless Implantable Opto-Electro Stimulation Device
Jia, Y., Gong, Y. P., Weber, A. J., Li, W., & Ghovanloo, M. (2020) · Micromachines · doi:10.3390/mi11060621 · Cited by 9
Christensen, D. B., Basaeri, H., & Roundy, S. (2017) · Smart Materials and Structures · doi:10.1088/1361-665x/aa95af · Cited by 8
Ye, W., Chen, L., Liu, F., Chen, X., & Wang, X. (2017) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2017.8096490 · Cited by 8
Inductive power transmission to millimeter-sized biomedical implants using printed spiral coils
Ibrahim, A., & Kiani, M. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591801 · Cited by 7
Analysis of a three-coil contactless power transfer system for high-power applications
Ghosh, P. C., Sadhu, P. K., & Ghosh, A. (2019) · Journal of the Chinese Institute of Engineers · doi:10.1080/02533839.2018.1559767 · Cited by 5
Neural Dust: Ultrasonic Biological Interface
Seo, D. (2016) · eScholarship (California Digital Library) · Cited by 2
Research works printed but not linked: 4
- ritchey, 1999, A survey and tutorial of dielectric materials used in the manufacture of printed circuit boards, CircuiTree Mag
- 10.1109/TBCAS.2017.2663358 · DOI
- marefat, 0, Proc IEEE Int Solid-State Circuits Conf, 412
- zou, 2019, Modelling single-wire capacitive power transfer system with strong coupling to ground, IEEE J Emerg Sel Topics Power Electron
Cited by
Sorted by citations
Recent Advancements in Emerging Technologies for Healthcare Management Systems: A Survey
Junaid, S. B., Imam, A. A., Balogun, A. O., Silva, L. C. D., Surakat, Y. A., Kumar, G., Abdulkarim, M., Shuaibu, A. N., Garba, A., Sahalu, Y., et al. (2022) · Healthcare · doi:10.3390/healthcare10101940 · Cited by 398
Wireless power delivery techniques for miniature implantable bioelectronics
Singer, A., & Robinson, J. T. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100664 · Cited by 159
Wireless Power Transfer—A Review
Detka, K., & Górecki, K. (2022) · Energies · doi:10.3390/en15197236 · Cited by 140
Erel, M. Z., Bayındır, K. Ç., Aydemir, M. T., Chaudhary, S. K., & Guerrero, J. M. (2021) · IEEE Access · doi:10.1109/access.2021.3139761 · Cited by 138
Miniature battery-free bioelectronics
Nair, V., Dalrymple, A. N., Yu, Z., Balakrishnan, G., Bettinger, C. J., Weber, D. J., Yang, K., & Robinson, J. T. (2023) · Science · doi:10.1126/science.abn4732 · Cited by 128
Metadata
- Authors
- Barbruni, G. L., Ros, P. M., Demarchi, D., Carrara, S., & Ghezzi, D.
- Affiliations
- Politecnico di Torino (IT)
- École Polytechnique Fédérale de Lausanne (CH)
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2020-12
- Volume
- 14
- Issue
- 6
- Pages
- 1160-1178
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- OpenAlex
- W3102254533
- Cited by
- 161
- References
- 104
- Citations by year
- 2026: 19 · 2025: 30 · 2024: 21 · 2023: 39 · 2022: 32 · 2021: 20
- FWCI
- 1.13
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- IEEE Transactions on Biomedical Circuits and Systems (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
- PORTO@Iris (submittedVersion, cc-by)
- Funders
- École Polytechnique Fédérale de Lausanne
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Keywords
- wireless power transfer, neurostimulation, implantable neurostimulator, miniaturization, inductive coupling, capacitive coupling, biomedical devices
- MeSH terms
- Biomedical Engineering, Brain, Humans, Miniaturization, Electric Power Supplies, Prosthesis Design, Implantable Neurostimulators, Wireless Technology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review