The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Development of an Ion-Sensitive Solid-State Device for Neurophysiological Measurements
Abstract
The development of an ion-sensitive solid-state device is described. The device combines the principles of an MOS transistor and a glass electrode and can be used for measurements of ion activities in electrochemical and biological environments. Some preliminary results are given.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The early ion-sensitive FET biosensor only exhibits good sensitivity to charged biomolecules but cannot detect neutral biomolecules, which limited their applications [4], [5].”
From A Vertically Stacked Nanosheet Gate-All-Around FET for Biosensing Application (2021) · cites this paper as [4]
Citations
Cites
Cation selective glass electrodes and their mode of operation
Eisenman, G. (1962) · Biophysical Journal · doi:10.1016/s0006-3495(62)86959-8 · Cited by 852
Characteristics of the Surface-State Charge (Qss) of Thermally Oxidized Silicon
Deal, B. E., Sklar, M., Grove, A. S., & Snow, E. H. (1967) · Journal of The Electrochemical Society · doi:10.1149/1.2426565 · Cited by 717
Design theory of a surface field-effect transistor
IHANTOLA, H. K. J., & Moll, J. L. (1964) · Solid-State Electronics · doi:10.1016/0038-1101(64)90039-5 · Cited by 190
New Amplification Method for Depth Recording
Bergveld, P. (1968) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1968.4502544 · Cited by 15
Self-citationThe influence of substrate bias upon the AC characteristics of MOS transistors
Bergveld, P. (1969) · Proceedings of the IEEE · doi:10.1109/proc.1969.6871 · Cited by 5
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
An integrated semiconductor device enabling non-optical genome sequencing
Rothberg, J. M., Hinz, W., Rearick, T. M., Schultz, J., Mileski, W., Davey, M. S., Leamon, J. H., Johnson, K., Milgrew, M. J., Edwards, M. M., et al. (2011) · Nature · doi:10.1038/nature10242 · Cited by 2,187
A Review on Biosensors and Recent Development of Nanostructured Materials-Enabled Biosensors
Naresh, V., & Lee, N. (2021) · Sensors · doi:10.3390/s21041109 · Cited by 2,213
Bergveld, P. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(02)00301-5 · Cited by 1,582
Self-citationCarbon Nanomaterials in Biosensors: Should You Use Nanotubes or Graphene?
Yang, W. R., Ratinac, K. R., Ringer, S. P., Thordarson, P., Gooding, J. J., & Braet, F. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200903463 · Cited by 1,446
Bhalla, N., Jolly, P., Formisano, N., & Estrela, P. (2016) · Essays in Biochemistry · doi:10.1042/ebc20150001 · Cited by 1,484
Oxide Materials for Development of Integrated Gas Sensors—A Comprehensive Review
Eranna, G., Joshi, B. C., Runthala, D. P., & Gupta, R. P. (2004) · Critical reviews in solid state and materials sciences/CRC critical reviews in solid state and materials sciences · doi:10.1080/10408430490888977 · Cited by 1,072
MoS2 Field-Effect Transistor for Next-Generation Label-Free Biosensors
Sarkar, D., Liu, W., Xie, X., Anselmo, A. C., Mitragotri, S., & Banerjee, K. (2014) · ACS Nano · doi:10.1021/nn5009148 · Cited by 1,060
Revealing neuronal function through microelectrode array recordings
Obien, M. E. J., Deligkaris, K., Bullmann, T., Bakkum, D. J., & Frey, U. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00423 · Cited by 705
Light-Addressable Potentiometric Sensor for Biochemical Systems
Hafeman, D. G., Parce, J. W., & McConnell, H. M. (1988) · Science · doi:10.1126/science.3375810 · Cited by 703
Bergveld, P. (1972) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1972.324137 · Cited by 654
Self-citationDetection principles of biological and chemical FET sensors
Kaisti, M. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.07.010 · Cited by 596
Bousse, L. J., de Rooij, N. F., & Bergveld, P. (1983) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1983.21284 · Cited by 570
Self-citationRecent advances in biologically sensitive field-effect transistors (BioFETs)
Schöning, M. J., & Poghossian, A. (2002) · The Analyst · doi:10.1039/b204444g · Cited by 566
Endeavor of Iontronics: From Fundamentals to Applications of Ion‐Controlled Electronics
Bisri, S. Z., Shimizu, S., Nakano, M., & Iwasa, Y. (2017) · Advanced Materials · doi:10.1002/adma.201607054 · Cited by 559
Protein-modified nanocrystalline diamond thin films for biosensor applications
Härtl, A., Schmich, E., Garrido, J. A., Hernando, J., Catharino, S., Walter, S., Feulner, P., Kromka, A., Steinmüller, D., & Stutzmann, M. (2004) · Nature Materials · doi:10.1038/nmat1204 · Cited by 518
New materials for micro-scale sensors and actuators
Wilson, S. A., Jourdain, R., Zhang, Q., Dorey, R., Bowen, C., Willander, M., Wahab, Q. U., Willander, M., Al-Hilli, S., Nur, O., et al. (2007) · Materials Science and Engineering R Reports · doi:10.1016/j.mser.2007.03.001 · Cited by 512
Metal oxides based electrochemical pH sensors: Current progress and future perspectives
Manjakkal, L., Szwagierczak, D., & Dahiya, R. (2019) · Progress in Materials Science · doi:10.1016/j.pmatsci.2019.100635 · Cited by 485
A critical review on the use of potentiometric based biosensors for biomarkers detection
Karimi‐Maleh, H., Orooji, Y., Karimi, F., Alizadeh, M., Baghayeri, M., Rouhi, J., Tajik, S., Beitollahi, H., Agarwal, S., Gupta, V. K., et al. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113252 · Cited by 480
Conducting Polyaniline Nanowire and Its Applications in Chemiresistive Sensing
Song, E., & Choi, J. (2013) · Nanomaterials · doi:10.3390/nano3030498 · Cited by 473
Electrolyte-gated transistors for enhanced performance bioelectronics
Torricelli, F., Adrahtas, D. Z., Bao, Z., Magnus Berggren, A., Biscarini, F., Bonfiglio, A., Bortolotti, C. A., Frisbie, C. D., Macchia, E., Malliaras, G. G., et al. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00065-8 · Cited by 450
Ion-Sensitive Field-Effect Transistor for Biological Sensing
Lee, C., Kim, S. K., & Kim, M. (2009) · Sensors · doi:10.3390/s90907111 · Cited by 437
Knopfmacher, O., Hammock, M. L., Appleton, A. L., Schwartz, G., Mei, J., Lei, T., Pei, J., & Bao, Z. (2014) · Nature Communications · doi:10.1038/ncomms3954 · Cited by 415
A general model to describe the electrostatic potential at electrolyte oxide interfaces
van Hal, R. E. G., Eijkel, J. C. T., & Bergveld, P. (1996) · Advances in Colloid and Interface Science · doi:10.1016/s0001-8686(96)00307-7 · Cited by 399
Self-citationSensing at the Surface of Graphene Field‐Effect Transistors
Fu, W., Jiang, L., van Geest, E. P., Lima, L. M. C., & Schneider, G. F. (2016) · Advanced Materials · doi:10.1002/adma.201603610 · Cited by 374
Progress in Ion Torrent semiconductor chip based sequencing
Merriman, B., Ion Torrent R D Team, & Rothberg, J. M. (2012) · Electrophoresis · doi:10.1002/elps.201200424 · Cited by 359
Nernst Limit in Dual-Gated Si-Nanowire FET Sensors
Knopfmacher, O., Tarasov, A., Fu, W., Wipf, M., Niesen, B., Calame, M., & Schönenberger, C. (2010) · Nano Letters · doi:10.1021/nl100892y · Cited by 353
Cell-Based Biosensors and Their Application in Biomedicine
Liu, Q., Wu, C., Cai, H., Hu, N., Zhou, J., & Wang, P. (2014) · Chemical Reviews · doi:10.1021/cr2003129 · Cited by 351
Implications of Nanobiosensors in Agriculture
Rai, V., Acharya, S., & Dey, N. (2012) · Journal of Biomaterials and Nanobiotechnology · doi:10.4236/jbnb.2012.322039 · Cited by 336
Ion-sensitive field-effect transistors fabricated in a commercial CMOS technology
Bausells, J., Carrabina, J., Errachid, A., & Merlos, Á. (1999) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(99)00135-5 · Cited by 326
A generalized theory of an electrolyte-insulator-semiconductor field-effect transistor
Fung, C. D., Cheung, W., & Ko, W. H. (1986) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1986.22429 · Cited by 321
van Hal, R. E. G., Eijkel, J. C. T., & Bergveld, P. (1995) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(95)85043-0 · Cited by 311
Self-citationBiosensing based on field-effect transistors (FET): Recent progress and challenges
Sadighbayan, D., Hasanzadeh, M., & Ghafar‐Zadeh, E. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2020.116067 · Cited by 318
Two-Dimensional Field-Effect Transistor Sensors: The Road toward Commercialization
Dai, C., Liu, Y., & Wei, D. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00924 · Cited by 311
Diagnostic biosensors in medicine – A review
Metkar, S. K., & Girigoswami, K. (2018) · Biocatalysis and Agricultural Biotechnology · doi:10.1016/j.bcab.2018.11.029 · Cited by 311
Kergoat, L., Piro, B., Magnus Berggren, A., Horowitz, G., & Pham, M. (2011) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-011-5363-y · Cited by 315
Biosensors and Microfluidic Biosensors: From Fabrication to Application
Kulkarni, M. B., Ayachit, N. H., & Aminabhavi, T. M. (2022) · Biosensors · doi:10.3390/bios12070543 · Cited by 306
pH response of GaN surfaces and its application for pH-sensitive field-effect transistors
Steinhoff, G., Hermann, M., Schaff, W. J., EASTMAN, L. F., Stutzmann, M., & Eickhoff, M. (2003) · Applied Physics Letters · doi:10.1063/1.1589188 · Cited by 285
Review—Field-Effect Transistor Biosensing: Devices and Clinical Applications
Syu, Y.-C., Hsu, W.-E., & Lin, C. (2018) · ECS Journal of Solid State Science and Technology · doi:10.1149/2.0291807jss · Cited by 287
History and New Developments of Assays for Cholinesterase Activity and Inhibition
Miao, Y., He, N., & Zhu, J. (2010) · Chemical Reviews · doi:10.1021/cr900214c · Cited by 268
Basic properties of the electrolyte—SiO2—Si system: Physical and theoretical aspects
Siu, W. M., & Cobbold, R. S. C. (1979) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1979.19690 · Cited by 268
Lindner, E., & Umezawa, Y. (2008) · Pure and Applied Chemistry · doi:10.1351/pac200880010085 · Cited by 263
Electric double-layer transistors: a review of recent progress
Du, H., Lin, X., Xu, Z., & Chu, D. (2015) · Journal of Materials Science · doi:10.1007/s10853-015-9121-y · Cited by 262
Labelfree fully electronic nucleic acid detection system based on a field-effect transistor device
Uslu, F., Ingebrandt, S., Mayer, D., Böcker-Meffert, S., Odenthal, M., & Offenhäusser, A. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.01.019 · Cited by 255
Outlook and Emerging Semiconducting Materials for Ambipolar Transistors
Bisri, S. Z., Piliego, C., Gao, J., & Loi, M. A. (2013) · Advanced Materials · doi:10.1002/adma.201304280 · Cited by 250
Metal oxide hydrogen, oxygen, and carbon monoxide sensors for hydrogen setups and cells
Aroutiounian, V. M. (2007) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2007.01.004 · Cited by 240
Electric-double-layer transistors for synaptic devices and neuromorphic systems
He, Y., Yang, Y., Nie, S., Liu, R., & Wan, Q. C. (2018) · Journal of Materials Chemistry C · doi:10.1039/c8tc00530c · Cited by 243
Field-Effect Transistor Biosensors for Biomedical Applications: Recent Advances and Future Prospects
Vu, C.-A., & Chen, W.-Y. (2019) · Sensors · doi:10.3390/s19194214 · Cited by 243
Inorganic semiconductor biointerfaces
Jiang, Y., & Tian, B. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0062-3 · Cited by 244
An Integrated Field-Effect Electrode for Biopotential Recording
Matsuo, T., & Wise, K. D. (1974) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1974.324338 · Cited by 235
Bio FEDs (Field‐Effect Devices): State‐of‐the‐Art and New Directions
Schöning, M. J., & Poghossian, A. (2006) · Electroanalysis · doi:10.1002/elan.200603609 · Cited by 231
MEMS sensors: past, present and future
Bogue, R. W. (2007) · Sensor Review · doi:10.1108/02602280710729068 · Cited by 219
Metal Oxides and Ion-Exchanging Surfaces as pH Sensors in Liquids: State-of-the-Art and Outlook
Kurzweil, P. R. (2009) · Sensors · doi:10.3390/s90604955 · Cited by 213
Microfabrication techniques for chemical/biosensors
Hierlemann, A. R., Brand, O., Hagleitner, C., & Baltes, H. (2003) · Proceedings of the IEEE · doi:10.1109/jproc.2003.813583 · Cited by 213
Nanoscale Ion Regulation in Wood‐Based Structures and Their Device Applications
Chen, C., & Hu, L. (2020) · Advanced Materials · doi:10.1002/adma.202002890 · Cited by 220
A novel glucose ENFET based on the special reactivity of MnO2 nanoparticles
Luo, X., Xu, J., Zhao, W., & Chen, H. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2003.11.019 · Cited by 214
The role of buried OH sites in the response mechanism of inorganic-gate pH-sensitive ISFETs
Bousse, L., & Bergveld, P. (1984) · Sensors and Actuators · doi:10.1016/0250-6874(84)80028-1 · Cited by 198
Self-citationComprehensive study of noise processes in electrode electrolyte interfaces
Hassibi, A., Navid, R., Dutton, R. W., & Lee, T. H. (2004) · Journal of Applied Physics · doi:10.1063/1.1755429 · Cited by 198
Integrated Micro Multi Ion Sensor Using Field Effect of Semiconductor
Esashi, M., & Matsuo, T. (1978) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1978.326245 · Cited by 198
EGFET-Based Sensors for Bioanalytical Applications: A Review
Pullano, S. A., Critello, C. D., Mahbub, I., Tasneem, N. T., Shamsir, S., Islam, S. K., Greco, M., & Fiorillo, A. S. (2018) · Sensors · doi:10.3390/s18114042 · Cited by 197
A charge-modulated FET for detection of biomolecular processes: conception, modeling, and simulation
Barbaro, M., Bonfiglio, A., & Raffo, L. (2005) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2005.860659 · Cited by 197
Study on extended gate field effect transistor with tin oxide sensing membrane
Chi, L.-L., Chou, J.-C., Chung, W., Sun, T., & Hsiung, S.-K. (2000) · Materials Chemistry and Physics · doi:10.1016/s0254-0584(99)00184-4 · Cited by 196
Transducer aspects of biosensors
Sethi, R. S. (1994) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(94)80127-4 · Cited by 194
Advances in electrochemical immunosensors
Skládal, P. (1997) · Electroanalysis · doi:10.1002/elan.1140091002 · Cited by 191
ISFET Based Microsensors for Environmental Monitoring
Jiménez‐Jorquera, C., Orozco, J., & Baldi, A. (2009) · Sensors · doi:10.3390/s100100061 · Cited by 187
Exploiting Ionic Coupling in Electronic Devices: Electrolyte‐Gated Organic Field‐Effect Transistors
Panzer, M. J., & Frisbie, C. D. (2008) · Advanced Materials · doi:10.1002/adma.200800617 · Cited by 186
Remote- and Ground-Based Sensor Techniques to Map Soil Properties
Barnes, E. M., Sudduth, K. A., Hummel, J. W., Lesch, S. M., Corwin, D. L., Yang, C., Daughtry, C. S. T., & Bausch, W. C. (2003) · Photogrammetric Engineering & Remote Sensing · doi:10.14358/pers.69.6.619 · Cited by 183
Evaluation of sensing technologies for on-the-go detection of macro-nutrients in cultivated soils
Sinfield, J. V., Fagerman, D., & Colic, O. (2009) · Computers and Electronics in Agriculture · doi:10.1016/j.compag.2009.09.017 · Cited by 182
Glucose monitoring: state of the art and future possibilities
Wilkins, E. S., & Atanasov, P. (1996) · Medical Engineering & Physics · doi:10.1016/1350-4533(95)00046-1 · Cited by 180
Hysteresis in Al2O3-gate ISFETs
Bousse, L. J., van den Vlekkert, H. H., & de Rooij, N. F. (1990) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(90)80018-u · Cited by 180
Cytosensor® Microphysiometer: technology and recent applications
Hafner, F. (2000) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(00)00069-5 · Cited by 179
Dual‐Gate Thin‐Film Transistors, Integrated Circuits and Sensors
Spijkman, M.-J., Myny, K., Smits, E. C. P., Heremans, P. L., Blom, P. W. M., & de Leeuw, D. M. (2011) · Advanced Materials · doi:10.1002/adma.201101493 · Cited by 180
Work function changes in gas sensitive materials: Fundamentals and applications
Oprea, A., Bârsan, N., & Weimar, U. (2009) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2009.06.043 · Cited by 176
Integrated circuit amplifiers for multi-electrode intracortical recording
Jochum, T., Denison, T., & Wolf, P. D. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/1/012001 · Cited by 169
Recent advances in nanowires-based field-effect transistors for biological sensor applications
Ahmad, R., Mahmoudi, T., Ahn, M., & Hahn, Y. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.09.024 · Cited by 163
Field-Induced Superconductivity in Electric Double Layer Transistors
Ueno, K., Shimotani, H., Yuan, H., Ye, J. T., Kawasaki, M., & Iwasa, Y. (2014) · Journal of the Physical Society of Japan · doi:10.7566/jpsj.83.032001 · Cited by 155
Microelectronic sensor system for microphysiological application on living cells
Baumann, W. (1999) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(99)00116-1 · Cited by 155
Dual‐Gate Organic Field‐Effect Transistors as Potentiometric Sensors in Aqueous Solution
Spijkman, M., Brondijk, J. J., Geuns, T. C. T., Smits, E. C. P., Cramer, T., Zerbetto, F., Stoliar, P., Biscarini, F., Blom, P. W. M., & de Leeuw, D. M. (2010) · Advanced Functional Materials · doi:10.1002/adfm.200901830 · Cited by 154
The light-addressable potentiometric sensor for multi-ion sensing and imaging
Yoshinobu, T., Iwasaki, H., Ui, Y., Furuichi, K., Ermolenko, Y. Е., Mourzina, Y. G., Wagner, T., Näther, N., & Schöning, M. J. (2005) · Methods · doi:10.1016/j.ymeth.2005.05.020 · Cited by 153
Lowe, B. M., Sun, K., Zeimpekis, I., Skylaris, C., & Green, N. G. (2017) · The Analyst · doi:10.1039/c7an00455a · Cited by 160
Hierlemann, A. R., Frey, U., Hafizovic, S., & Heer, F. (2010) · Proceedings of the IEEE · doi:10.1109/jproc.2010.2066532 · Cited by 153
Novel semiconductor materials for the development of chemical sensors and biosensors: A review
Chaniotakis, N. A., & Sofikiti, N. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.03.046 · Cited by 143
Highly sensitive palladium oxide thin film extended gate FETs as pH sensor
Das, A., Ko, D. H., Chen, C.-H., Chang, L., Lai, C., Chu, F.-C., Chow, L., & Lin, R. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.08.057 · Cited by 142
Krishnan, S. K., Nataraj, N., Meyyappan, M., & Pal, U. (2023) · Analytical Chemistry · doi:10.1021/acs.analchem.2c03399 · Cited by 142
Potentiometric Anion Selective Sensors
Antonisse, M. M. G., & Reinhoudt, D. N. (1999) · Electroanalysis · doi:10.1002/(sici)1521-4109(199910)11:14 · Cited by 141
Modeling of Semiconductor Nanostructures with nextnano3
Birner, S., Hackenbuchner, S., Sabathil, M., Zandler, G., Majewski, J. A., Andlauer, T. F. M., Zibold, T., Morschl, R., Trellakis, A., & Vogl, P. (2006) · Acta Physica Polonica A · doi:10.12693/aphyspola.110.111 · Cited by 140
Chou, J.-C., & Liao, L. P. (2004) · Thin Solid Films · doi:10.1016/j.tsf.2004.09.061 · Cited by 137
Label‐Free Sensing of Biomolecules with Field‐Effect Devices for Clinical Applications
Poghossian, A., & Schöning, M. J. (2014) · Electroanalysis · doi:10.1002/elan.201400073 · Cited by 142
Hébert, C., Masvidal‐Codina, E., Suarez‐Perez, A., Calia, A. B., Piret, G., Garcia‐Cortadella, R., Illa, X., del Corro, E., de la Cruz, J. M., Viana, D., et al. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201703976 · Cited by 136
Enzyme biosensors based on ion-selective field-effect transistors
Dzyadevych, S. V., Soldatkin, A. P., El'skaya, A. V., Martelet, C., & Jaffrezic-Renault, N. J. (2005) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.11.057 · Cited by 135
Beyond the Nernst-limit with dual-gate ZnO ion-sensitive field-effect transistors
Spijkman, M., Smits, E. C. P., Cillessen, J. F. M., Biscarini, F., Blom, P. W. M., & de Leeuw, D. M. (2011) · Applied Physics Letters · doi:10.1063/1.3546169 · Cited by 135
Porous silicon as a substrate material for potentiometric biosensors
Thust, M., Schöning, M. J., Frohnhoff, S., Arens-Fischer, R., Kordos, P., & Luth, H. (1996) · Measurement Science and Technology · doi:10.1088/0957-0233/7/1/003 · Cited by 134
Eickhoff, M., Schalwig, J., Steinhoff, G., Weidemann, O., Görgens, L., Neuberger, R., Hermann, M., Baur, B., Müller, G., Ambacher, O., et al. (2003) · Physica status solidi. C, Conferences and critical reviews/Physica status solidi. C, Current topics in solid state physics · doi:10.1002/pssc.200303139 · Cited by 132
Jamasb, S., Collins, S. D., & Smith, R. L. (1998) · IEEE Transactions on Electron Devices · doi:10.1109/16.678525 · Cited by 132
In situ sensor techniques in modern bioprocess monitoring
Beutel, S., & Henkel, S. (2011) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-011-3470-5 · Cited by 136
Design, Simulation and Performance Analysis of JLTFET Biosensor for High Sensitivity
Wadhwa, G., & Raj, B. (2019) · IEEE Transactions on Nanotechnology · doi:10.1109/tnano.2019.2918192 · Cited by 130
Microfabricated Ion‐Selective Transistors with Fast and Super‐Nernstian Response
Han, S., Yamamoto, S., Polyravas, A. G., & Malliaras, G. G. (2020) · Advanced Materials · doi:10.1002/adma.202004790 · Cited by 130
Design of a Single-Chip pH Sensor Using a Conventional 0.6- $muhbox m$ CMOS Process
Hammond, P. A., Ali, D., & Cumming, D. R. S. (2004) · IEEE Sensors Journal · doi:10.1109/jsen.2004.836849 · Cited by 130
A TCAD-Based Methodology to Model the Site-Binding Charge at ISFET/Electrolyte Interfaces
Bandiziol, A., Palestri, P., Pittino, F., Esseni, D., & Selmi, L. (2015) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2015.2464251 · Cited by 129
Current trends in nanomaterial embedded field effect transistor-based biosensor
Nehra, A., & Singh, K. P. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.07.030 · Cited by 129
Separate structure extended gate H+-ion sensitive field effect transistor on a glass substrate
Yin, L., Chou, J.-C., Chung, W., Sun, T., & Hsiung, S.-K. (2000) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(00)00613-4 · Cited by 129
Metadata
- Authors
- Bergveld, P.
- Corresponding author
- Bergveld, P.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1970-01
- Volume
- BME-17
- Issue
- 1
- Pages
- 70-71
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2032168109
- Cited by
- 2,134
- References
- 5
- Citations by year
- 2026: 63 · 2025: 77 · 2024: 91 · 2023: 88 · 2022: 97 · 2021: 115 · 2020: 99 · 2019: 78 · 2018: 91 · 2017: 104 · 2016: 67 · 2015: 87 · 2014: 109 · 2013: 95 · 2012: 74
- FWCI
- 1.05
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Keywords
- MOS transistors, glass electrode, ion activity measurement, electrochemical sensor, biological environment, neurophysiological measures
- MeSH terms
- Electrodes, Electronics, Medical, Ions, Neurophysiology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review