The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Scattering of Ultrasound by Blood
Abstract
The ultrasonic volumetric scattering cross section of the erythrocyte has been measured over a range of frequencies by comparing the rms value of the gated backscattered signal from the blood with that of a wave reflected from a flat reflector with known reflection coefficient. It is found to be proportional to the fourth power of the frequency predicted by the wave scattering theory for small particles in the frequency range from 5 MHz to 15 MHz. The relation between the scattering coefficient and the hematocrit is also examined up to a hematocrit of 45 percent. This coefficient is found to increase along with the hematocrit until it reaches a maximum around hematocrit = 26 percent and then decreases as the hematocrit increases. Twersky's wave scattering theory is applied to describe this result.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Morse, P. M., Ingard, K. U., & Beyer, R. T. (1969) · Journal of Applied Mechanics · doi:10.1115/1.3564682 · Cited by 3,188
Utsunomiya, T. (1970) · The Journal of the Institute of Television Engineers of Japan · doi:10.3169/itej1954.24.687 · Cited by 493
A Sound Velocity Method for Determining the Compressibility of Finely Divided Substances
Urick, R. J. (1947) · Journal of Applied Physics · doi:10.1063/1.1697584 · Cited by 362
Sigelmann, R. A., & Reid, J. M. (1973) · The Journal of the Acoustical Society of America · doi:10.1121/1.1913479 · Cited by 191
Self-citationTabular Data of the Velocity and Absorption of High-Frequency Sound in Mammalian Tissues
Goldman, D. E., & Hueter, T. F. (1956) · The Journal of the Acoustical Society of America · doi:10.1121/1.1908216 · Cited by 178
Cited by
Ultrasound contrast agents: A review
Goldberg, B. B., Liu, J.-B., & Forsberg, F. (1994) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(94)90001-9 · Cited by 486
Oelze, M. L., & Mamou, J. (2016) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2015.2513958 · Cited by 383
Functional ultrasound imaging of the brain: theory and basic principles
Mace, E., Montaldo, G., Osmanski, B.-F., Cohen, I., Fink, M., & Tanter, M. (2013) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2013.2592 · Cited by 327
Contrast agents in diagnostic ultrasound
Ophir, J., & Parker, K. J. (1989) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(89)90044-6 · Cited by 322
Tissue-mimicking phantoms for photoacoustic and ultrasonic imaging
Cook, J. R., Bouchard, R. R., & Emelianov, S. Y. (2011) · Biomedical Optics Express · doi:10.1364/boe.2.003193 · Cited by 285
Ultrasound techniques for characterizing colloidal dispersions
Challis, R. E., Povey, M. J. W., Mather, M. L., & Holmes, A. K. (2005) · Reports on Progress in Physics · doi:10.1088/0034-4885/68/7/r01 · Cited by 282
Continuous monitoring of deep-tissue haemodynamics with stretchable ultrasonic phased arrays
Wang, C., Qi, B., Lin, M., Zhang, Z., Makihata, M., Liu, B., Zhou, S., Huang, Y.-H., Hu, H., Gu, Y., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00763-4 · Cited by 274
YU, F. T. H., ARMSTRONG, J. K., TRIPETTE, J., MEISELMAN, H. J., & CLOUTIER, G. (2011) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2010.04164.x · Cited by 108
Colour Doppler energy (power) mode ultrasound
Macsweeney, J. E., Cosgrove, D. O., & Arenson, J. (1996) · Clinical Radiology · doi:10.1016/s0009-9260(96)80155-3 · Cited by 63
Metadata
- Authors
- Shung, K. K., Sigelmann, R. A., & Reid, J. M.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1976-11
- Volume
- BME-23
- Issue
- 6
- Pages
- 460-467
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2083237704
- Cited by
- 306
- References
- 5
- FWCI
- 10.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.